3/4" x 3/4". Includes (2) 3/4" to 1/2" reducerbushings. Pressure regulator is factory-set3.5" W.C. natural gas. Field adjustable 3" to7" W.C, ** Has slow opening feature for soft ignition. Can be field removed., Lo-Fire, Hi-Fire, Capacity*, 1.3" W.C., 3.5" W.C., 300,000, * 1000 BTU/Cu. Ft. .064sp. gr. natural gas or 2500 BTU/Cu. Ft. 1.53 sp. gr. L.P. gas @ 1" W.C. pd., 2 Reducer Bushings Included (NPT): 3/4" x 1/2", Inlet Size (FPT): 3/4", Outlet Size FPT): 3/4", Type of Gas: Natural |
|
|
|
|
|
|
|
Can be used as a replacement for most standing pilot furnaces. |
|
|
|
Flame Pattern - 3 way |
|
|
Valve Type: 24 Volt, Pressure Regulator Setting: LP Gas |
Automatic pilot safety valve and Manual valve (gas cock), Pilot outlet, pilot gas filter, pilot adjusting key., Control can be mounted in any position, except upside down, All models have 3 position outlets., Specifications:, Temperature range (hydraulic models): 58 to 90 F, Pilot outlet: 1/4" tubing, Inlet Size (FPT): 1/2", 3-Position Outlet (FPT) with 1/2" Pipe Plugs Reducer Bushings Included (FPT) 1/2" x 3/8" Gas cock dial marketing: Off-Pilot-On, Ambient temperature: -40 to 175 F, Electrical Rating: 24 volt model 12 VDC -.18 amps, 24 VAC -.2 amps, Millivolt model: 250 MV to 750 MV operating range, Capacity: 70,000 maximum / 1000 BTU/cu. ft. 0.64 sp. gr. natural gas at 1" W.C. Pd., Pressure Regulator (optional by model): Factory set @ 5.5" W.C. |
|
|
Valve Type: Millivolt, Pressure Regulator Setting: 3.5 W.C. Natural Gas |
Automatic pilot safety valve and Manual valve (gas cock), Pilot outlet, pilot gas filter, pilot adjusting key., Control can be mounted in any position, except upside down, All models have 3 position outlets., Specifications:, Temperature range (hydraulic models): 58 to 90 F, Pilot outlet: 1/4" tubing, Inlet Size (FPT): 1/2", 3-Position Outlet (FPT) with 1/2" Pipe Plugs Reducer Bushings Included (FPT) 1/2" x 3/8" Gas cock dial marketing: Off-Pilot-On, Ambient temperature: -40 to 175 F, Electrical Rating: 24 volt model 12 VDC -.18 amps, 24 VAC -.2 amps, Millivolt model: 250 MV to 750 MV operating range, Capacity: 70,000 maximum / 1000 BTU/cu. ft. 0.64 sp. gr. natural gas at 1" W.C. Pd., Pressure Regulator (optional by model): Factory set @ 5.5" W.C. |
|
|
Valve Type: Millivolt, Pressure Regulator Setting: 3.5 W.C. Natural Gas |
Automatic pilot safety valve and Manual valve (gas cock), Pilot outlet, pilot gas filter, pilot adjusting key., Control can be mounted in any position, except upside down, All models have 3 position outlets., Specifications:, Temperature range (hydraulic models): 58 to 90 F, Pilot outlet: 1/4" tubing, Inlet Size (FPT): 1/2", 3-Position Outlet (FPT) with 1/2" Pipe Plugs Reducer Bushings Included (FPT) 1/2" x 3/8" Gas cock dial marketing: Off-Pilot-On, Ambient temperature: -40 to 175 F, Electrical Rating: 24 volt model 12 VDC -.18 amps, 24 VAC -.2 amps, Millivolt model: 250 MV to 750 MV operating range, Capacity: 70,000 maximum / 1000 BTU/cu. ft. 0.64 sp. gr. natural gas at 1" W.C. Pd., Pressure Regulator (optional by model): Factory set @ 5.5" W.C. |
|
|
Capacity: 150,000, Factory Model: 7200ERC, Inset (FPT): 1/2", Outlet (FPT): 1/2", Reducer Bushings Included (NPT) 3/4” x 1/2" 1/2" x 3/8” 3/4" x 3/8” Replaces: 120-402 And 120-407 |
Specifications:, Electrical Rating: 24 VAC, 5 amps, Pressure Regulator: Factory set @3.5" W.C. (Natural Gas),@11.0" W.C.(LP Gas), Pilot outlet: 1/4" tubing, Ambient temperature: -40 to 175 F, Maximum inlet pressure: 7" W.C. - natural gas / 14" W.C. - LP Gas, ** Convertible regulator for mobile home use. Select 3.5" W.C. natural gas or 11.0" W.C. L.P. Gas. |
|
|
Capacity: 150,000, Factory Model: 7200ERCS, Inset (FPT): 1/2", Outlet (FPT): 1/2", Reducer Bushings Included (NPT) 3/4” x 1/2" 1/2" x 3/8” 3/4" x 3/8” Replaces: 120-473 And 120-474 |
Specifications:, Electrical Rating: 24 VAC, 5 amps, Pressure Regulator: Factory set @3.5" W.C. (Natural Gas),@11.0" W.C.(LP Gas), Pilot outlet: 1/4" tubing, Ambient temperature: -40 to 175 F, Maximum inlet pressure: 7" W.C. - natural gas / 14" W.C. - LP Gas, ** Convertible regulator for mobile home use. Select 3.5" W.C. natural gas or 11.0" W.C. L.P. Gas. |
|
|
Capacity: 150,000, Outlet: 3/4", Pressure Regulator Setting: UNI-KIT, Factory Model: 7200-DER, Inset: 1/2", 3/4" x 1/2": 1 |
Specifications:, Electrical Rating: 24 VAC, 5 amps, Pressure Regulator:, Natural Gas: Factory set @ 3.5" W.C., LP Gas: Factory set @ 11.0" W.C., Pilot outlet: 1/4" tubing, Ambient temperature: -40 to 175 F, Maximum inlet pressure: 7" W.C. - natural gas / 14" W.C. - LP Gas |
|
|
|
Wall-mount, wash-down urinal, Rim-flushing action, Exposed trap, Easy to clean, Concealed hanger and bolts, Includes 3/4" top spud and hanger. Less flushometer, Compatible Carriers Zurn Z1221 & Z1222 Series, Meets or exceeds ASME A112.19.-2008/CSA B45.1-08 |
|
|
|
L0402 |
|
|
|
L0404, - Flame, resuscitation system. Use with gas valves 7000BDER and 7100DER. Has 60 second lockout timing. |
|
|
|
L0405, - Universal lockout model. Replaces SP735 and SP735A. Has three 60 second valve trials interrupted by a five minute purge cycle before 100% lockout. |
|
|
Series: 700 SERIES (MODEL 7000), 710 SERIES (MODEL 7000 LC), Fuel Type: Propane, Adj WC Pressure Low/High: 8" / 12", Comments: Except hydraulic models which cannot be field converted, Product Type: LP Gas Regulator, Regulator Type: 11.0" W.C. L.P. GAS, Suitable For: L.P. GAS |
|
|
|
Gas Valve: 71000 (720-070) 1/2" x 3/4", Ignition Unit: SP715 (780-715) Non-lockout |
L0532, :, Ignition Unit: SP715 (780-715) Non-lockout, Description: Natural Gas only Non-lockout. Valve is designed for natural gas. Pressure regulator is factory set at 3.5" W.C. 200,000 Btu Max. W.C., Caution: Do Not Use On L.P. Gas Applications., L0533, :, Ignition Unit: SP735 (780-735) Lockout, Description: L. P. Gas only-Lockout. Gas valve has natural gas regulator set at 3.5" W.C. A separate L.P. gas pressure regulator set at 11.0" W.C. is also included. 200,000 Btu Max. Nat. Gas / 320,000 Btu Max. LP Gas. |
|
|
Gas Valve: (700-070) 1/2" x 3/4", Ignition Unit: SP735 (780-735) Lockout |
L0532, :, Ignition Unit: SP715 (780-715) Non-lockout, Description: Natural Gas only Non-lockout. Valve is designed for natural gas. Pressure regulator is factory set at 3.5" W.C. 200,000 Btu Max. W.C., Caution: Do Not Use On L.P. Gas Applications., L0533, :, Ignition Unit: SP735 (780-735) Lockout, Description: L. P. Gas only-Lockout. Gas valve has natural gas regulator set at 3.5" W.C. A separate L.P. gas pressure regulator set at 11.0" W.C. is also included. 200,000 Btu Max. Nat. Gas / 320,000 Btu Max. LP Gas. |
|
|
|
The 10-681 flame sensor replaces Carrier/ BDP part# LH33WZ511 & is used in a system with the 41-409 hot surface ignitor. |
|
|
|
1/4" OD x 5' Aluminum Tubing. |
|
|
Pressure Range P.S.I.G.: (10") to 100, Differential P.S.I.: 10 to 40, 36" Capillary with Flare Nut: 010-1483 |
These controls offer a variety of pressure ranges and switch actions to provide maximum application flexibility., NEMA 1 enclosure with non-conductive cover, Front located captive cover screw, Large, easy-to-read scale plate, SUPER CAP capillary protection system, Universal mounting and compact design, Screw terminals are raised and fully accessible for easy wiring, Laser-welded bellows for extended life, Heavy-duty plates steel frame, Suitable for R12, R22, and R502 applications |
|
|
Pressure Range P.S.I.G.: 100 to 400, Differential P.S.I.: 40 to 150, 36" Capillary with Flare Nut: 016-108 |
These controls offer a variety of pressure ranges and switch actions to provide maximum application flexibility., NEMA 1 enclosure with non-conductive cover, Front located captive cover screw, Large, easy-to-read scale plate, SUPER CAP capillary protection system, Universal mounting and compact design, Screw terminals are raised and fully accessible for easy wiring, Laser-welded bellows for extended life, Heavy-duty plates steel frame, Suitable for R12, R22, and R502 applications |
|
|
|
Cover Shape: Rectangle, Cover Dimensions (Inside): Solid 6-3/8" L x 3-1/2" W x 3" D, Cover Material: Transparent, Base Type: Solid or Ring |
|
|
Factory Model: 72001PERS7C |
Specifications:, Electrical Rating: 24 VAC, 50/60 Hz .45 amps, Power Consumption: 5 watts, NEC: Class 2, Terminal Connections: 1/4" quick-connect, Pilot outlet: 1/4" tubing, Ambient temperature: -40 to 175 F Max., Maximum inlet pressure: 14" W.C. (1/2 PSI), Pressure regulator setting: UNI-KIT |
|
|
|
System Switch Functions: Heat-Off-Cool, Fan Switch Function: Auto-On, Application: Universal, Field adaptable wiring allows conversion to most applications. |
|
|
|
Specifications:, Electrical Rating: 12 VDC -.18 amps, 24 VAC -.2 amps, Pressure Regulator: Factory set @ 3.5" W.C., Pilot outlet: 1/4" tubing, Gas cock dial marketing: Off-Pilot-On, Terminal type: combination screw/spade, Ambient temperature: -40 to 175 F |
|
|
|
Specifications:, Electrical Rating: 12 VDC -.18 amps, 24 VAC -.2 amps, Pressure Regulator: Factory set @ 3.5" W.C., Pilot outlet: 1/4" tubing, Gas cock dial marketing: Off-Pilot-On, Terminal type: combination screw/spade, Ambient temperature: -40 to 175 F |
|
|
|
Specifications:, Electrical Rating: 240MV to 750MV operating range, Pressure Regulator (optional by model): Factory set @ 3.5 W.C., Pilot outlet: 1/4" tubing, Gas cock dial marketing: Off-Pilot-On, Terminal Type: Combination screw/spade, Ambient temperature: -40 to 175 F, Inlet Size (FPT): 1/2", Pressure Regulator Setting: 3.5 W.C. Nat. Gas, Capacity: 100,000, 2 Reducer Bushings Included (FPT): 1/2" x 3/4" |
|
|
Length: 18" |
|
|
|
Length: 24" |
|
|
|
Length: 30" |
|
|
|
Length: 36" |
|
|
|
Length: 48" |
|
|
|
|
Specifications:, Electrical Rating: 12 VDC -.18 amps, 24 VAC -.2 amps, Pressure Regulator: Factory set @ 3.5" W.C., Pilot outlet: 1/4" tubing, Gas cock dial marketing: Off-Pilot-On, Terminal type: combination screw/spade, Ambient temperature: -40 to 175 F |
|
|
|
Introducing Robertshaw 720 Series dual valve gas controls. Used in 24 volt standing pilot applications, the 720 has a 150,000 BTU capacity at 3.5" WC, and a swing radius of 3-9/16"., Inlet Size FPT), 1/2", Outlet Size (FPT), 3/4", Pressure Regulator Setting, Uni-Kit, Capacity, 150,000, Reducer Bushings Included (NPT), 3/4" x 1/2", 1/2" x 3/8", 3/4" x 3/8" |
|
|
|
This control provides accurate temperature adjustment to turn on heat in response to outdoor temperature. |
|
|
|
|
|
|
|
|
|
|
|
Specifications:, Electrical Rating: 12 VDC -.18 amps, 24 VAC -.2 amps, Pressure Regulator: Factory set @ 3.5" W.C., Pilot outlet: 1/4" tubing, Gas cock dial marketing: Off-Pilot-On, Terminal type: combination screw/spade, Ambient temperature: -40 to 175 F |
|
|
Capacity: 150000, Amps: 0.45 amp., Electrical Rating: 24VAC, Inlet Size: 1/2", Outlet Size: 3/4", Power Consumption: 5 watts, Ambient Temperature: -40 to 175°F max., Hertz: 50/60 Hz, Pressure Regulator Setting: Uni-Kit, Maximum Inlet Pressure: 14" W.C. (1/2 PSI), NEC: class 2, Pilot Outlet: 1/4" tubing, Terminal Connections: 1/4" and 3/16" quick-connect |
The 720 Series Valves (7200 IPER) are designed for intermittent pilot ignition applications., The 720 IPER Series Valve incorporates a manual valve, pilot valve, dual automatic valves (2), and a main gas pressure regulator., Uni-Kits are factory-set at the 3.5" W.C. for natural gas, but can be converted to L.P. by installing the regulator conversion kit included., The 720 Series Valves are designed for many residential applications such as central heating units, space heaters, wall heaters, boilers, and mobile home furnaces. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Description Ext.: 41-408 HOT SURFACE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Sensor has a high temperature Kanthol sensor rod that will withstand 1800 F. it has 30 of Teflon insulated lead wire with a 482 F rating and a 1/4" quick connect terminal., Sensor rod is 4" long, can be cut and bent to match original unit. |
|