Product Image Not Available FAN RELAY
Locke Part #: L0326MFG Part #: 90-370
687152066841
Gas Valve 1/2" x 3/4", 24 VAC, Proven Pilot Valve, Fast Open, Electric On/Off Switch, 1/4" O.D Pilot Fitting replaces 36E36-304, Convertible - natural or LP gas, Adjustable regulator(s), Inlet/outlet screens, Electric on-off switch, Pressure taps, CSA approved, Included LP Conversion Kit, 1/2" x 3/4" and 1/2" x 3/8 Bushings, Fast Open, flow - straight thru
Gas Valve, 1/2" x 3/4", straight thru, 24 VAC, Pilot (No plug in), Delay opening 5 sec. (.006 orifice), Slow opening, 3/16 terminal adapter on terminal #4 Balance of terminals (4) is 1/4 spade, Pressure switch on cap, Nat gas Regulator set at 3.5 +/- .3 in WC at 110 KBTU/hr, Leak limiting hose barb (fitting) on regulator tower
Easy-to-Read 4-Square-Inch Blue Display, Active Comfort Alert Compressor Protection, Keypad Lockout, Adjustable Set point Temperature Limits, Battery Power Monitor, Millivolt and Hydronic Zone Valve Compatible, Exclusive Cool Savings
Emerson Blue 2" Display, Single Stage (1H/1C) 5+1+1 Day Programmable Digital Thermostat, Backlit Display, 24 Volts Or Millivolt, System Switch-Heat, Off, Cool, Fan Switch-Auto, On, Profile-Horizontal, Dual Power (System And/or Battery), Replaces 1F80-361, Range 45-90 F
Gas Valve, 1/2" x 3/4", 24 VAC, Thermocouple Actuated Line Interrupter, Reducer Bushings (3/4" To 1/2" And 1/2" To 3/8"), Includes LP Conversion Kit, ECO Terminals, Convertible natural or LP gas, Adjustable regulator, Inlet/outlet screens, Line interrupter, Pressure taps, CSA approved, Optional side outlets
Universal Gas Valve, 1/2" x 3/4", 24 VAC, Side Outlets Tapped And Plugged, Thermocouple Actuated Line Interrupter, Reducer Bushings (3/4" To 1/2" And1/2" To 3/8"), Includes LP Conversion Kit, ECO Terminals, Convertible natural or LP gas, Adjustable regulator, Inlet/outlet screens, Line interrupter, Pressure taps, CSA approved, Optional side outlets
Emerson Big Blue 12" Display, Touchscreen Universal (1H/1C) Conventional single stage, (2H/1C) Heat pump single stage with Aux or Emergency heat, 7 Day, 5+1+1 Day Or Non-Programmable Digital Thermostat, Backlit Display, 24 Volts or Mv, Digital Remote Sense Opt, Auto Changeover, System Switch-Heat, Off, Cool, Auto, Fan Switch-Auto, On, Program Fan, EMR, Keypad Lockout, Profile-Horizontal, Dual Power, Optional "C" Connection And/Or Batteries, Range 45-99 F
Gas Valve 3/4" x 3/4", 24 VAC, Proven Pilot Valve, Fast Open, Electric On/Off Switch, 1/4" O.D Pilot Fitting replaces 36E36-304, Convertible - natural or LP gas, Adjustable regulator(s), Inlet/outlet screens, Electric on-off switch, Pressure taps, CSA approved, Included LP Conversion Kit, 1/2" x 3/4" and 1/2" x 3/8 Bushings, Fast Open, flow - straight thru
Single Stage (1H/1C) 5 +1 +1 Day Programmable Digital Thermostat, Large, 4-square-inch blue Lighted display with easy-to-see characters, 24 Volt Or Millivolt, Profile-Horizontal, Configures as manual heat/cool, auto changeover, heat only or cool only, Exclusive Cool Savings feature saves energy during peak A/C demand periods, Hydronic 2 or 3 wire applications, Battery power monitor, Easy-access battery compartment, Dual Power with Optional "C" Connection And/or Batteries, 5-year warranty
Single Stage (1H/1C) Non-Programmable Digital Thermostat, Large, 4-square-inch blue Lighted display with easy-to-see characters, 24 Volt Or Millivolt, Profile-Horizontal, Configures as manual heat/cool, auto changeover, heat only or cool only, Exclusive Cool Savings feature saves energy during peak A/C demand periods, Hydronic 2 or 3 wire applications, Battery power monitor, Easy-access battery compartment, Dual Power with Optional "C" Connection And/or Batteries, 5-year warranty
Universal 120V Silicon Nitride Upgrade Kit for Conversion of silicon carbide (flat or spiral), Replaces over 150 OEM, White-Rodgers and competitive HSI ignitors, Features latest Nitride construction - used in most OEM applications, Universal breakaway bracket makes installation easy, eliminating the need for multiple brackets, Nitride Ignitor with 15.5" Leads, One Universal Mounting Bracket and Screw Mounting Adaptor Bracket, 2 Ceramic Wire Nuts, Updated Manufacturer Cross-Reference, Nitride Upgrade Furnace Label, Instruction Booklet, Includes:, 2 brackets, Furnace label, instruction booklet,, and 2 ceramic wire nuts
Universal Gas Valve, 3/4" x 3/4", Reducer Bushings (Two 3/4" To 1/2"), 24V, 1/4" Male Spade Quick Connect Terminals, Nat. Gas, For use on non-piloted or intermittent pilot applications (not standing pilot), Convertible - natural or LP gas, Adjustable regulator(s), Inlet/outlet screens, Electric on-off switch, Pressure taps, CSA approved, Includes LP Conversion Kit
3 Fan Speeds - Cool, Low Heat & High Heat Speeds (Terminal Connections), Color-Coded (Labeled) Thermostat Connection - For Quick Helpful Selection, System Diagnostics, with Fault Recall (Stored), Cover Label - Displays Diagnostic Table, Red LED Light - Used for Diagnostic Flash Codes, Low Voltage - Fuse Protection - 3A Replaceable Automotive Type, Humidifier & Electronic Air Cleaner Connections (Optional), Kit Includes:, 50M56-843 Ignition Control Module, 21D64-2 Ignitor Kit, Set of Interconnect Harnesses
Includes diagnostic indicator flash codes, 3 fan speeds, Remote flame sense, Humidifier and electronic air cleaner connections (optional), Kit includes:, 1 50A66-843 Ignition Control Board, 1 Wiring harness (9-pin to 12-pin), 1 Wiring harness (4-pin to 6-pin), 1 Mounting panel, 4 Stand-off fasteners, 1 Circuit breaker, 1 4" blue wire, 2 Wiring diagrams
Combination Gas Valve, Single Stage, Fast Opening, Inlet / Outlet pressure taps, Plastic hose barb (for connection to 1/4 hose/flexible tubing). LP gas conversion kit,, Inlet/Outlet reducer bushings (1/2 NPT x 3/8 NPT), Regulator calibrated to 3.5 0.3" W.C. @ 100KBTU/Hr (Nat Gas), 24 VAC, 60 Hz, 1/2 x 1/2 NPT, Adjustable regulator(s), CSA approved
Patented coaxial solenoid design., Inlet and optional outlet screens help protect from debris., Controlled gasket compression., Tamper resistant screws., Built-in hose connections for simplified field service or Std. 1/8" NPT (optional)., Conveniently located electric on-off switch., Versatile mounting., Inlet/Outlet screen, Mounting (Any position), Quiet redundant, Electrical shut-off, Top mounted components, Outlet pressure tap (5/16" I.D. hose connection), Vent connection (5/16" I.D. hose connection), Quick-connect terminals (1/4"), Mounting holes for 8-32 screws, Adjustable regulator(s), Maximum pressure (1/2 PSI), CSA approved
Easy To Install, No C wire required for most applications Heat Only & Cool Only Systems Require a C Wire, Traditional wire and configure installation, Simple to Connect, Connect to home Wi-Fi at installation or let your customer connect later with the Sensi app, Use Android or iOS devices to connect Wi-Fi, Connect with Your Customers, Put your company name and contact info in your customer s smartphone or tablet so you are one tap away when service is needed; sign up for free at SensiRegistration.com, Over-The-Air (OTA) Product Updates, The first Sensi thermostat sold is better than ever, Connected customers automatically receive the latest features like newly added alert emails and dual fuel capability, Universal Application, Up to 4 heat / 2 cool, Works without Wi-Fi as a standard thermostat, Rated Differential, Conventional, Fast, Medium, Slow, Heat, 0.5 F, 0.75 F, 1.9 F, Cool, 0.9 F, 1.2 F, 1.7 F, Heat Pump, Heat & Cool, 0.9 F, 1.2 F, 1.7 F
Emerson Blue Easy Set 2" Display, Single Stage (1H/1C) Non-Programmable Digital Thermostat with Home - Sleep - Away Presets, Backlit Display, 24 Volts or Millivolt, System Switch-Heat, Off, Cool,, Fan Switch-Auto, On, Profile-Horizontal, Dual Power (System And Or Battery, Range 45-90 F
Single Stage (1H/1C), Multi-Stage (2H/2C) Or Heat Pump up to (4H/2C) Applications., Hard wired or Battery Powered with Power Stealing Assist, 6-Square Inch Display, Easy-to-Use and Easy-to-Read, Simple One-Button One-Function Operation, Ships in Non-Programmable Mode, Program Choices: Non-Programmable or 7-Day program, Temperature Setpoint Limits, Dual Fuel Capable with Smart Fuel Logic Program, Backlit Display, 24 Volts or Millivolt, System Switch-Heat, Off, Cool, Aux Heat, Fan Switch-Auto, On, Profile-Horizontal,, Tri-Power (R-C) And/or Batteries w/optional power stealing assist
Emerson Big Blue 12" Touchscreen Multi-Stage Or Heat-Pump Thermostat (4H/2C) With Two Mode Dehumidification, Dual Fuel Option 7-Day Programmable, Backlit Display, 24 Volts, Automatic Changeover, System Switch-Heat, Off, Cool, Emergency, Auto, Fan Switch- Auto, On,, Programmable Fan, Energy Management Recovery, Remote Sense Option, Keypad Lockout, Profile-Horizontal, Tripower (Hardwire, Power Stealing, Battery), Range 45-99 F
Emerson Big Blue 12" Display, Touchscreen Premium Universal (1H/1C), Multi-Stage (2H/2C) Heat-Pump or Duel Fuel Option (4H/2C), Program Choices: 7 Day, 5+1+1 Day Or Non-Programmable Digital Thermostat, Backlit Display, Digital Remote Sense Opt., BacklitDisplay, 24 Volt Or MV, Auto Changeover,, System Switch-Heat, Off, Cool, Auto, Fan Switch-Auto, On, Program Fan, EMR, Keypad Lockout, Profile-Horizontal, Dual Power, Range 45-99 F, Optional "C" and/or Batteries
Emerson Blue Wireless Easy Install 6" Display, Universal Single Stage (1H/1C), Multi-Stage (2H/2C), Heat-Pump up to (4H/2C), With Humidification / Dehum, 7-Day Program, Backlit, Auto Changeover, Dual Fuel (Requires Sensor Below), System Switch-Heat, Off, Cool, Emergency, Auto, Fan Switch- Auto, On, EMR. Keypad Lockout, Profile-Horizontal, Range 45-99 F. , Module Terminals - RC,RH,C,G,Y,Y2,W/E,W2,O/B,L,DHM,DHM2,HM,HM2, Includes:, Wireless Comfort Interface, Equipment Control and Return-Air Sensor
Wireless Remote Indoor or Outdoor Temperature Sensor for the 1F98EZ-1621 Wireless Easy Install, 1F98EZ-1621 Accepts Up To 3 Indoor and 1 Outdoor Sensors, Outdoors the Sensor can be used for Dual Fuel Heat Pump Systems., Indoors, Sensor(s) can help reduce hot and cold spots in the home
Snap Action Contact, Fan Switch-Auto, On, System Switch-Heat, Off, Cool, Profile-Horizontal, can be used on 3 wire zone valve and 750mV applications, Includes Heat/Cool only Terminal Wallplate, Replacement for Hundreds of White-Rodgers and Competitive Models Installed During the Past 50 Years, Enclosed Contacts for Increased Reliability and Accuracy, 3-Wire Zone Single Stage and Millivolt Applications, 5-Year Warranty
Snap Action Contact, Fan Switch-Auto, On, System Switch-Heat, Off, Cool, Profile-Horizontal, can be used on 3 wire zone valve and 750mV applications, Includes Heat/Cool only Terminal Wallplate, Replacement for Hundreds of White-Rodgers and Competitive Models Installed During the Past 50 Years, Enclosed Contacts for Increased Reliability and Accuracy, 3-Wire Zone Single Stage and Millivolt Applications, 5-Year Warranty
120 VAC Two-Speed Inducer Output, 120 VAC Humidifier Output, Fuse Protection 3 Amp, 120 VAC Electronic Air Cleaner Output, 16-Pin Variable Speed Circulator Output, OEM Application Dipswitch Selectable, 120 VAC Ignitor Output, 2-Stage Gas Valve Output, Furnace Status LED Tri-Color (Green, Red and Amber), CFM LED (Green), Fan ON Delay for Cooling, Heat Fan OFF Delay (Dipswitch Selectable), Historical Fault Retrieval by Pushbutton, Pressure Switch Inputs and Monitoring, YLO, Y, W, W2, R, G, C, O, BK/DS/Dehum Terminals, Flash Microprocessor with Non-Volatile Memory, Auto Second Stage Delay (Dipswitch Selectable Mode), Flame Current Measurement Points
120 VAC Two-Speed Inducer Output, 120 VAC Humidifier Output, Fuse Protection 3 Amp, 120 VAC Electronic Air Cleaner Output, 16-Pin Variable Speed Circulator Output, OEM Application Dipswitch Selectable, 120 VAC Ignitor Output, 2-Stage Gas Valve Output, Furnace Status LED Tri-Color (Green, Red and Amber), CFM LED (Green), Fan ON Delay for Cooling, Heat Fan OFF Delay (Dipswitch Selectable), Historical Fault Retrieval by Pushbutton, Pressure Switch Inputs and Monitoring, YLO, Y, W, W2, R, G, C, O, BK/DS/Dehum Terminals, Flash Microprocessor with Non-Volatile Memory, Auto Second Stage Delay (Dipswitch Selectable Mode), Flame Current Measurement Points
SureSwitch Relay - Universal Electronic Upgrade for Mechanical Compressor Contactors: 240 VAC, 50/60 Hz, 30 FLA, 150 LRA, 24 VAC Coil - UP TO 40A 1-1.5P APPLIC, Microprocessor controlled sealed compressor switching, Line voltage brownout protection, Short cycle protection, Tricolor LED displays, Heavy-duty lug connectors, Zero chatter latching relay, Four-hole mounting matches mechanical contactors, Random start delay on power up and brownout recovery, Compressor test and cycle count by pushbutton, 5x contactor life, Sealed relay to keep out ants and debris, Microprocessor control nearly eliminates contact welding and pitting, Ideal install with new Preventative Maintenance contracts, Compressor is protected from brownouts and short cycling, Save on pest control treatments