Loading ...

Loading ...

Search in: CONCORD

L8181.jpg4HP14L18P - 1.5 TON HEAT PUMP
Locke Part #: L8181MFG Part #: 11J40 Compare
Voltage Range: 197-253, A: 24.25, B: 24.25, C: 28.5, Tonnage: 1.5, Volts / Hz / Phase: 208-230/60/1, Minimum: 11.9, Maximum: 20, Liquid Connection O.D. (inch): 3/8, Vapor Connection O.D. (inch): 3/4, SEER: 14 Features and Benefits, R410A Refrigerant, High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity, Top discharge directs hot air and sound away from living area and shrubbery, All units run tested, Available with louvered panel coil production, Easy access to electrical panels, pre-wired for easy hook-up, Bidirectional liquid line filter drier factory installed, Discharge muffler for quiet operation, Reliable, solid state defrost control, Defrost control is Quiet Shift capable, Low pressure switch factory installed for loss of charge protection, Integrated control with LED diagnostics, Short cycle protection factory installed, All units UL and ULC approved and AHRI listed, Charged for 15 feet of interconnecting tubing
L8181.jpg4HP14L24P 2 TON HT PMP 14 SEER
Locke Part #: L8182MFG Part #: 11J41 Compare
Voltage Range: 197-253, A: 24.25, B: 24.25, C: 28.5, Tonnage: 2, Volts / Hz / Phase: 208-230/60/1, Minimum: 17.5, Maximum: 30, Liquid Connection O.D. (inch): 3/8, Vapor Connection O.D. (inch): 3/4 Features and Benefits, R410A Refrigerant, High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity, Top discharge directs hot air and sound away from living area and shrubbery, All units run tested, Available with louvered panel coil production, Easy access to electrical panels, pre-wired for easy hook-up, Bidirectional liquid line filter drier factory installed, Discharge muffler for quiet operation, Reliable, solid state defrost control, Defrost control is Quiet Shift capable, Low pressure switch factory installed for loss of charge protection, Integrated control with LED diagnostics, Short cycle protection factory installed, All units UL and ULC approved and AHRI listed, Charged for 15 feet of interconnecting tubing
L8181.jpg4HP14L30P 2.5 TON HT PMP 14 SEER
Locke Part #: L8183MFG Part #: 11J42 Compare
Voltage Range: 197-253, A: 24.25, B: 24.25, C: 32.5, Tonnage: 2.5, Volts / Hz / Phase: 208-230/60/1, Minimum: 17, Maximum: 30, Liquid Connection O.D. (inch): 3/8, Vapor Connection O.D. (inch): 3/4 Features and Benefits, R410A Refrigerant, High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity, Top discharge directs hot air and sound away from living area and shrubbery, All units run tested, Available with louvered panel coil production, Easy access to electrical panels, pre-wired for easy hook-up, Bidirectional liquid line filter drier factory installed, Discharge muffler for quiet operation, Reliable, solid state defrost control, Defrost control is Quiet Shift capable, Low pressure switch factory installed for loss of charge protection, Integrated control with LED diagnostics, Short cycle protection factory installed, All units UL and ULC approved and AHRI listed, Charged for 15 feet of interconnecting tubing
L8181.jpg4HP14L36P 3 TON HT PMP 14 SEER
Locke Part #: L8184MFG Part #: 11J43 Compare
Voltage Range: 197-253, A: 32.25, B: 32.25, C: 28.5, Tonnage: 3, Volts / Hz / Phase: 208-230/60/1, Minimum: 19.4, Maximum: 30, Liquid Connection O.D. (inch): 3/8, Vapor Connection O.D. (inch): 3/4 Features and Benefits, R410A Refrigerant, High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity, Top discharge directs hot air and sound away from living area and shrubbery, All units run tested, Available with louvered panel coil production, Easy access to electrical panels, pre-wired for easy hook-up, Bidirectional liquid line filter drier factory installed, Discharge muffler for quiet operation, Reliable, solid state defrost control, Defrost control is Quiet Shift capable, Low pressure switch factory installed for loss of charge protection, Integrated control with LED diagnostics, Short cycle protection factory installed, All units UL and ULC approved and AHRI listed, Charged for 15 feet of interconnecting tubing
L8181.jpg4HP14L42P 3.5 TON HT PMP 14 SEER
Locke Part #: L8185MFG Part #: 11J44 Compare
Voltage Range: 197-253, A: 32.25, B: 32.25, C: 36.5, Tonnage: 3.5, Volts / Hz / Phase: 208-230/60/1, Minimum: 24.2, Maximum: 40, Liquid Connection O.D. (inch): 3/8, Vapor Connection O.D. (inch): 7/8 Features and Benefits, R410A Refrigerant, High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity, Top discharge directs hot air and sound away from living area and shrubbery, All units run tested, Available with louvered panel coil production, Easy access to electrical panels, pre-wired for easy hook-up, Bidirectional liquid line filter drier factory installed, Discharge muffler for quiet operation, Reliable, solid state defrost control, Defrost control is Quiet Shift capable, Low pressure switch factory installed for loss of charge protection, Integrated control with LED diagnostics, Short cycle protection factory installed, All units UL and ULC approved and AHRI listed, Charged for 15 feet of interconnecting tubing
L8181.jpg4HP14L48P 4 TON HT PMP 14 SEER
Locke Part #: L8186MFG Part #: 11J45 Compare
Voltage Range: 197-253, A: 32.25, B: 32.25, C: 36.5, Tonnage: 4, Volts / Hz / Phase: 208-230/60/1, Minimum: 29, Maximum: 50, Liquid Connection O.D. (inch): 3/8, Vapor Connection O.D. (inch): 7/8 Features and Benefits, R410A Refrigerant, High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity, Top discharge directs hot air and sound away from living area and shrubbery, All units run tested, Available with louvered panel coil production, Easy access to electrical panels, pre-wired for easy hook-up, Bidirectional liquid line filter drier factory installed, Discharge muffler for quiet operation, Reliable, solid state defrost control, Defrost control is Quiet Shift capable, Low pressure switch factory installed for loss of charge protection, Integrated control with LED diagnostics, Short cycle protection factory installed, All units UL and ULC approved and AHRI listed, Charged for 15 feet of interconnecting tubing
L8181.jpg4HP14L60P 5 TON HT PMP 14 SEER
Locke Part #: L8187MFG Part #: 11J46 Compare
Voltage Range: 197-253, A: 32.25, B: 32.25, C: 42.5, Tonnage: 5, Volts / Hz / Phase: 208-230/60/1, Minimum: 34.8, Maximum: 60, Liquid Connection O.D. (inch): 3/8, Vapor Connection O.D. (inch): 1-1/8 Features and Benefits, R410A Refrigerant, High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity, Top discharge directs hot air and sound away from living area and shrubbery, All units run tested, Available with louvered panel coil production, Easy access to electrical panels, pre-wired for easy hook-up, Bidirectional liquid line filter drier factory installed, Discharge muffler for quiet operation, Reliable, solid state defrost control, Defrost control is Quiet Shift capable, Low pressure switch factory installed for loss of charge protection, Integrated control with LED diagnostics, Short cycle protection factory installed, All units UL and ULC approved and AHRI listed, Charged for 15 feet of interconnecting tubing
L8195.jpg4AC14LR18P-6A 1.5 TON 14 SEER CONDENSER
Locke Part #: L8195MFG Part #: 13L42 Compare
Voltage Range: 197-253, A: 24.25, B: 24.25, C: 28.5, Tonnage: 1.5, Minimum: 12, Maximum: 20, Volts/Hz/Phase: 208-230/60/1, Liquid O.D. (inch): 3/8, Suction O.D. (inch): 3/4, Rated Load (Amps): 9, Locked Rotor (Amps): 48 Features and Benefits, R410A Refrigerant, Durable compressors with internal pressure relief valves and inherent thermal protection, High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity, Top discharge directs hot air and sound away from living area and shrubbery, All units are factory run tested, Available with louvered panel coil protection, Easy access to electrical panels, prewired for easy hook-up to internal components, 45-degree service valves for easy hook-up and service, Liquid line filter drier shipped loose, All units UL and ULC approved and AHRI listed, Charged for 15 feet of interconnecting tubing
L8195.jpg4AC14LR24P-6A 2 TON 14 SEER CONDENSER
Locke Part #: L8196MFG Part #: 13L43 Compare
Voltage Range: 197-253, A: 28.25, B: 28.25, C: 32.5, Tonnage: 2, Minimum: 17.9, Maximum: 30, Volts/Hz/Phase: 208-230/60/1, Liquid O.D. (inch): 3/8, Suction O.D. (inch): 3/4, Rated Load (Amps): 13.4, Locked Rotor (Amps): 58 Features and Benefits, R410A Refrigerant, Durable compressors with internal pressure relief valves and inherent thermal protection, High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity, Top discharge directs hot air and sound away from living area and shrubbery, All units are factory run tested, Available with louvered panel coil protection, Easy access to electrical panels, prewired for easy hook-up to internal components, 45-degree service valves for easy hook-up and service, Liquid line filter drier shipped loose, All units UL and ULC approved and AHRI listed, Charged for 15 feet of interconnecting tubing
L8195.jpg4AC14LR30P-6A 2.5 TON 14 SEER CONDENSER
Locke Part #: L8197MFG Part #: 13L64 Compare
Voltage Range: 197-253, A: 28.25, B: 28.25, C: 36.5, Tonnage: 2.5, Minimum: 17.2, Maximum: 30, Volts/Hz/Phase: 208-230/60/1, Liquid O.D. (inch): 3/8, Suction O.D. (inch): 3/4, Rated Load (Amps): 12.9, Locked Rotor (Amps): 64 Features and Benefits, R410A Refrigerant, Durable compressors with internal pressure relief valves and inherent thermal protection, High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity, Top discharge directs hot air and sound away from living area and shrubbery, All units are factory run tested, Available with louvered panel coil protection, Easy access to electrical panels, prewired for easy hook-up to internal components, 45-degree service valves for easy hook-up and service, Liquid line filter drier shipped loose, All units UL and ULC approved and AHRI listed, Charged for 15 feet of interconnecting tubing
L8195.jpg4AC14LR36P-6A 3 TON 14 SEER CONDENSER
Locke Part #: L8198MFG Part #: 13L77 Compare
Voltage Range: 197-253, A: 28.25, B: 28.25, C: 36.5, Tonnage: 3, Minimum: 18.7, Maximum: 30, Volts/Hz/Phase: 208-230/60/1, Liquid O.D. (inch): 3/8, Suction O.D. (inch): 7/8, Rated Load (Amps): 14.1, Locked Rotor (Amps): 77 Features and Benefits, R410A Refrigerant, Durable compressors with internal pressure relief valves and inherent thermal protection, High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity, Top discharge directs hot air and sound away from living area and shrubbery, All units are factory run tested, Available with louvered panel coil protection, Easy access to electrical panels, prewired for easy hook-up to internal components, 45-degree service valves for easy hook-up and service, Liquid line filter drier shipped loose, All units UL and ULC approved and AHRI listed, Charged for 15 feet of interconnecting tubing
L8195.jpg4AC14LR42P-6A 3.5 TON 14 SEER CONDENSER
Locke Part #: L8199MFG Part #: 13L78 Compare
Voltage Range: 197-253, A: 28.25, B: 28.25, C: 28.5, Tonnage: 3.5, Minimum: 24.1, Maximum: 40, Volts/Hz/Phase: 208-230/60/1, Liquid O.D. (inch): 3/8, Suction O.D. (inch): 7/8, Rated Load (Amps): 17.9, Locked Rotor (Amps): 112 Features and Benefits, R410A Refrigerant, Durable compressors with internal pressure relief valves and inherent thermal protection, High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity, Top discharge directs hot air and sound away from living area and shrubbery, All units are factory run tested, Available with louvered panel coil protection, Easy access to electrical panels, prewired for easy hook-up to internal components, 45-degree service valves for easy hook-up and service, Liquid line filter drier shipped loose, All units UL and ULC approved and AHRI listed, Charged for 15 feet of interconnecting tubing
L8195.jpg4AC14L48P 4 TON CONDENS 14 SEER
Locke Part #: L8200MFG Part #: 11J27 Compare
Voltage Range: 197-253, A: 28.25, B: 28.25, C: 36.5, Tonnage: 4, Minimum: 29, Maximum: 50, Volts/Hz/Phase: 208-230/60/1, Liquid O.D. (inch): 3/8, Suction O.D. (inch): 7/8, Rated Load (Amps): 21.8, Locked Rotor (Amps): 117 Features and Benefits, R410A Refrigerant, Durable compressors with internal pressure relief valves and inherent thermal protection, High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity, Top discharge directs hot air and sound away from living area and shrubbery, All units are factory run tested, Available with louvered panel coil protection, Easy access to electrical panels, prewired for easy hook-up to internal components, 45-degree service valves for easy hook-up and service, Liquid line filter drier shipped loose, All units UL and ULC approved and AHRI listed, Charged for 15 feet of interconnecting tubing
L8195.jpg4AC14L60P 5 TON CONDENS 14 SEER
Locke Part #: L8201MFG Part #: 11J29 Compare
Voltage Range: 197-253, A: 32.25, B: 32.25, C: 32.5, Tonnage: 5, Minimum: 34.8, Maximum: 60, Volts/Hz/Phase: 208-230/60/1, Liquid O.D. (inch): 3/8, Suction O.D. (inch): 1-1/8, Rated Load (Amps): 26.4, Locked Rotor (Amps): 134 Features and Benefits, R410A Refrigerant, Durable compressors with internal pressure relief valves and inherent thermal protection, High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity, Top discharge directs hot air and sound away from living area and shrubbery, All units are factory run tested, Available with louvered panel coil protection, Easy access to electrical panels, prewired for easy hook-up to internal components, 45-degree service valves for easy hook-up and service, Liquid line filter drier shipped loose, All units UL and ULC approved and AHRI listed, Charged for 15 feet of interconnecting tubing
Voltage: 208-230/60/1, Refrigerant: 410A, Shipping Weight (Lbs): 210, Voltage Range: 197-253, SEER: 14, Compressor - RLA: 16.7, Compressor - LRA: 79, Refrigerant Charge (Oz): 161, Sound dBA: 76, Configuration: Louvered, Minimum Circuit Amp: 22.6, Max Over Current Device (amps): 35, Dimensions (Width x Depth x Height) In: 28.25 x 28.25 x 37, Nominal Capacity (Btuh): 41,000, Outdoor Fan Motor - Rated Load (amps): 1.7, Outdoor Fan Motor - Rated HP: 1/4, Outdoor Fan Motor - Nominal RPM: 825
Voltage: 208-230/60/1, Refrigerant: 410A, Shipping Weight (Lbs): 251, Voltage Range: 197-253, SEER: 14, Compressor - RLA: 19.9, Compressor - LRA: 109, Refrigerant Charge (Oz): 179, Sound dBA: 80, Configuration: Louvered, Minimum Circuit Amp: 26.7, Max Over Current Device (amps): 45, Dimensions (Width x Depth x Height) In: 28.25 x 28.25 x 37, Nominal Capacity (Btuh): 47,000, Outdoor Fan Motor - Rated Load (amps): 1.8, Outdoor Fan Motor - Rated HP: 1/3, Outdoor Fan Motor - Nominal RPM: 825
Voltage: 208-230/60/1, Refrigerant: 410A, Shipping Weight (Lbs): 235, Voltage Range: 197-253, SEER: 14, Compressor - RLA: 25.0, Compressor - LRA: 134, Refrigerant Charge (Oz): 178, Sound dBA: 78, Configuration: Louvered, Minimum Circuit Amp: 34.1, Max Over Current Device (amps): 50, Dimensions (Width x Depth x Height) In: 32.25 x 32.25 x 37, Nominal Capacity (Btuh): 59,000, Outdoor Fan Motor - Rated Load (amps): 2.8, Outdoor Fan Motor - Rated HP: 1/3, Outdoor Fan Motor - Nominal RPM: 825
L8210.jpg80G1UH045AP12 UP/HORZ FURN 45M BTU 1200 CFM
Locke Part #: L8210MFG Part #: 67W19 Compare
Gas Inlet: 1/2", Motor HP: 1/3, Nominal Cooling Capacity: 2-3, Weight (lbs.): 110, Input (BTUH): 44,000, Output (BTUH): 35,200, AFUE: 80%, Min. Time Delay Breaker or Fuse: 15, Nominal F.L.A.: 6.1, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel tapered crimped no-weld clam shell heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, Multi-speed PSC blower motor, Easily removable slide out blower design, Controls, Single stage gas valve, Self diagnostics saving last 5 fault codes regardless of power interruption, Installation Features, Left or right utility connections, Removable floor base for bottom return air, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
L8210.jpg80G1UH070AP12 UP/HORZ FURN 70M 1200 CFM
Locke Part #: L8211MFG Part #: 67W21 Compare
Gas Inlet: 1/2", Motor HP: 1/3, Nominal Cooling Capacity: 2-3, Weight (lbs.): 119, Input (BTUH): 66,000, Output (BTUH): 52,800, AFUE: 80%, Min. Time Delay Breaker or Fuse: 15, Nominal F.L.A.: 6.1, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel tapered crimped no-weld clam shell heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, Multi-speed PSC blower motor, Easily removable slide out blower design, Controls, Single stage gas valve, Self diagnostics saving last 5 fault codes regardless of power interruption, Installation Features, Left or right utility connections, Removable floor base for bottom return air, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
L8210.jpg80G1UH090BP12 UP/HORZ FURN 90M BTU 1200 CFM
Locke Part #: L8212MFG Part #: 67W22 Compare
Gas Inlet: 1/2", Motor HP: 1/3, Nominal Cooling Capacity: 2-3, Weight (lbs.): 131, Input (BTUH): 88,000, Output (BTUH): 70,400, AFUE: 80%, Min. Time Delay Breaker or Fuse: 15, Nominal F.L.A.: 6.1, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel tapered crimped no-weld clam shell heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, Multi-speed PSC blower motor, Easily removable slide out blower design, Controls, Single stage gas valve, Self diagnostics saving last 5 fault codes regardless of power interruption, Installation Features, Left or right utility connections, Removable floor base for bottom return air, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
L8210.jpg80G1UH090BP16 UP/HORZ FURN 90M BTU 1600 CFM
Locke Part #: L8213MFG Part #: 67W23 Compare
Gas Inlet: 1/2", Motor HP: 1/2, Nominal Cooling Capacity: 3-4, Weight (lbs.): 183, Input (BTUH): 88,000, Output (BTUH): 70,400, AFUE: 80%, Min. Time Delay Breaker or Fuse: 15, Nominal F.L.A.: 8.2, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel tapered crimped no-weld clam shell heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, Multi-speed PSC blower motor, Easily removable slide out blower design, Controls, Single stage gas valve, Self diagnostics saving last 5 fault codes regardless of power interruption, Installation Features, Left or right utility connections, Removable floor base for bottom return air, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
L8210.jpg80G1UH110CP16 UP/HORZ FURN 100M BTU 1600 CFM
Locke Part #: L8214MFG Part #: 67W25 Compare
Gas Inlet: 1/2", Motor HP: 1/2, Nominal Cooling Capacity: 3-4, Weight (lbs.): 151, Input (BTUH): 110,000, Output (BTUH): 88,000, AFUE: 80%, Min. Time Delay Breaker or Fuse: 15, Nominal F.L.A.: 8.2, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel tapered crimped no-weld clam shell heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, Multi-speed PSC blower motor, Easily removable slide out blower design, Controls, Single stage gas valve, Self diagnostics saving last 5 fault codes regardless of power interruption, Installation Features, Left or right utility connections, Removable floor base for bottom return air, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
L8210.jpg80G1UH110CP20 UP/HORZ FURN 110M BTU 2000 CFM
Locke Part #: L8215MFG Part #: 67W26 Compare
Gas Inlet: 1/2", Motor HP: 3/4, Nominal Cooling Capacity: 4-5, Weight (lbs.): 161, Input (BTUH): 110,000, Output (BTUH): 88,000, AFUE: 80%, Min. Time Delay Breaker or Fuse: 15, Nominal F.L.A.: 10, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel tapered crimped no-weld clam shell heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, Multi-speed PSC blower motor, Easily removable slide out blower design, Controls, Single stage gas valve, Self diagnostics saving last 5 fault codes regardless of power interruption, Installation Features, Left or right utility connections, Removable floor base for bottom return air, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
L8210.jpg80G1UH135DP20 UP/HORZ FURN 135M BTU 2000CFM
Locke Part #: L8216MFG Part #: 67W27 Compare
Gas Inlet: 1/2", Motor HP: 3/4, Nominal Cooling Capacity: 4-5, Weight (lbs.): 174, Input (BTUH): 132,000, Output (BTUH): 105,600, AFUE: 80%, Min. Time Delay Breaker or Fuse: 15, Nominal F.L.A.: 10, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel tapered crimped no-weld clam shell heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, Multi-speed PSC blower motor, Easily removable slide out blower design, Controls, Single stage gas valve, Self diagnostics saving last 5 fault codes regardless of power interruption, Installation Features, Left or right utility connections, Removable floor base for bottom return air, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
L8217.jpg80G1DF045AP12 DWNFLW FURN 45M BTU 1200 CFM
Locke Part #: L8217MFG Part #: 67W32 Compare
Gas Inlet: 1/2", Motor HP: 1/3, Nominal Cooling Capacity: 2-3, Weight (lbs.): 112, Input (BTUH): 44,000, Output (BTUH): 35,200, AFUE: 80%, Min. Time Delay Breaker or Fuse: 15, Nominal F.L.A.: 6.1, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel tapered crimped no-weld clam shell heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, Multi-speed PSC blower motor, Easily removable slide out blower design, Controls, Single stage gas valve, Self diagnostics saving last 5 fault codes regardless of power interruption, Installation Features, Left or right utility connections, "L" designated models comply with California's South Coast Air Quality Management district Low NOx requirements, Removable floor base for bottom return air, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
L8217.jpg80G1DF070AP12 DWNFLW FURN 70M BTU 1200 CFM
Locke Part #: L8218MFG Part #: 67W33 Compare
Gas Inlet: 1/2", Motor HP: 1/3, Nominal Cooling Capacity: 2-3, Weight (lbs.): 121, Input (BTUH): 66,000, Output (BTUH): 52,800, AFUE: 80%, Min. Time Delay Breaker or Fuse: 15, Nominal F.L.A.: 6.1, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel tapered crimped no-weld clam shell heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, Multi-speed PSC blower motor, Easily removable slide out blower design, Controls, Single stage gas valve, Self diagnostics saving last 5 fault codes regardless of power interruption, Installation Features, Left or right utility connections, "L" designated models comply with California's South Coast Air Quality Management district Low NOx requirements, Removable floor base for bottom return air, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
L8217.jpg80G1DF090BP16 DWNFLW FURN 90M 1600 CFM 67W34
Locke Part #: L8219MFG Part #: 67W34 Compare
Gas Inlet: 1/2", Motor HP: 1/2, Nominal Cooling Capacity: 3-4, Weight (lbs.): 140, Input (BTUH): 88,000, Output (BTUH): 70,400, AFUE: 80%, Min. Time Delay Breaker or Fuse: 15, Nominal F.L.A.: 8.2, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel tapered crimped no-weld clam shell heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, Multi-speed PSC blower motor, Easily removable slide out blower design, Controls, Single stage gas valve, Self diagnostics saving last 5 fault codes regardless of power interruption, Installation Features, Left or right utility connections, "L" designated models comply with California's South Coast Air Quality Management district Low NOx requirements, Removable floor base for bottom return air, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
L8217.jpg80G1DF110CP20 DNF FURN 110M BTU 2000 CFM
Locke Part #: L8220MFG Part #: 67W35 Compare
Gas Inlet: 1/2", Motor HP: 3/4, Nominal Cooling Capacity: 4-5, Weight (lbs.): 163, Input (BTUH): 110,000, Output (BTUH): 88,000, AFUE: 80%, Min. Time Delay Breaker or Fuse: 15, Nominal F.L.A.: 10, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel tapered crimped no-weld clam shell heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, Multi-speed PSC blower motor, Easily removable slide out blower design, Controls, Single stage gas valve, Self diagnostics saving last 5 fault codes regardless of power interruption, Installation Features, Left or right utility connections, "L" designated models comply with California's South Coast Air Quality Management district Low NOx requirements, Removable floor base for bottom return air, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
L8231.jpg95G1DF045BP12 DOWFLOW 45K BTU 1200 CFM FURN
Locke Part #: L8231MFG Part #: 67W64 PD00144170 Compare
Gas Inlet: 1/2", Motor HP: 1/3, Nominal Cooling Capacity: 2-3, Weight (lbs.): 125, Input (BTUH): 44,000, Output (BTUH): 42,000, AFUE: 95%, Min. Time Delay Breaker or Fuse: 15, Nominal F.L.A.: 6.1, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel design primary heat exchanger with crimped no weld construction, AL 29-4C stainless steel secondary heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, ECM variable speed blower motor, Easily removable slide out blower design, Controls, Modulating gas valve, Self diagnostics saves last 10 fault codes regardless of power interruption, Venting, Category 4 direct vent appliance, Installation Features, Left or right utility connections, Zero step horizontal conversion, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
L8231.jpg95G1DF070BP12 DOWNFLOW 70K BTU 1200 CFM FURN
Locke Part #: L8232MFG Part #: 67W65 PD00144170 Compare
Gas Inlet: 1/2", Motor HP: 1/3, Nominal Cooling Capacity: 2-3, Weight (lbs.): 131, Input (BTUH): 66,000, Output (BTUH): 64,000, AFUE: 95%, Min. Time Delay Breaker or Fuse: 15, Nominal F.L.A.: 6.1, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel design primary heat exchanger with crimped no weld construction, AL 29-4C stainless steel secondary heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, ECM variable speed blower motor, Easily removable slide out blower design, Controls, Modulating gas valve, Self diagnostics saves last 10 fault codes regardless of power interruption, Venting, Category 4 direct vent appliance, Installation Features, Left or right utility connections, Zero step horizontal conversion, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
L8231.jpg95G1DF090CP20 DOWNFLOW 90K BTU 2000 CFM FURN
Locke Part #: L8233MFG Part #: 67W66 PD00144170 Compare
Gas Inlet: 1/2", Motor HP: 1, Nominal Cooling Capacity: 4-5, Weight (lbs.): 150, Input (BTUH): 88,000, Output (BTUH): 85,000, AFUE: 95%, Min. Time Delay Breaker or Fuse: 20, Nominal F.L.A.: 11.5, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel design primary heat exchanger with crimped no weld construction, AL 29-4C stainless steel secondary heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, ECM variable speed blower motor, Easily removable slide out blower design, Controls, Modulating gas valve, Self diagnostics saves last 10 fault codes regardless of power interruption, Venting, Category 4 direct vent appliance, Installation Features, Left or right utility connections, Zero step horizontal conversion, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
L8231.jpg95G1DF110CP20 DOWNFLOW 110K BTU 2000 CFM FURN
Locke Part #: L8234MFG Part #: 67W67 PD00144170 Compare
Gas Inlet: 1/2", Motor HP: 1, Nominal Cooling Capacity: 4-5, Weight (lbs.): 165, Input (BTUH): 110,000, Output (BTUH): 106,000, AFUE: 95%, Min. Time Delay Breaker or Fuse: 20, Nominal F.L.A.: 11.5, Trans. (V.A.): 40, Volts/Hz/Phase: 120/60/1 Heat Exchanger Design, Aluminized steel design primary heat exchanger with crimped no weld construction, AL 29-4C stainless steel secondary heat exchanger, Cabinet Design, Compact 33 height, Standardized widths for easy coil fit, Air Delivery System, ECM variable speed blower motor, Easily removable slide out blower design, Controls, Modulating gas valve, Self diagnostics saves last 10 fault codes regardless of power interruption, Venting, Category 4 direct vent appliance, Installation Features, Left or right utility connections, Zero step horizontal conversion, Warranty, 10 year limited parts warranty / lifetime heat exchanger warranty available.
Voltage: 120/60/1, CFM: 3 Ton add on cooling, Stages: Single, Nominal Cooling Capacity: 1-1/2 - 3, Configuration: Upflow/Horizontal, Input (Btuh): 44,000, Output (Btuh): 42,000, AFUE (ICS): 95.0%, Gas Inlet (In): 1/2, Max Time Delay Breaker or Fuse: 15, Nominal FLA: 6.8, Trans (VA): 40, Approx Shipping Weight (Lbs): 129, Cabinet Width (In): 17.5, Blower Drive: High Efficiency
Voltage: 120/60/1, CFM: 3 Ton add on cooling, Stages: Single, Nominal Cooling Capacity: 1-1/2 - 3, Configuration: Upflow/Horizontal, Input (Btuh): 66,000, Output (Btuh): 64,000, AFUE (ICS): 95.0%, Gas Inlet (In): 1/2, Max Time Delay Breaker or Fuse: 15, Nominal FLA: 6.8, Trans (VA): 40, Approx Shipping Weight (Lbs): 136, Cabinet Width (In): 17.5, Blower Drive: High Efficiency
Voltage: 120/60/1, CFM: 4 Ton add on cooling, Stages: Single, Nominal Cooling Capacity: 2-1/2 - 4, Configuration: Upflow/Horizontal, Input (Btuh): 88,000, Output (Btuh): 85,000, AFUE (ICS): 95.0%, Gas Inlet (In): 1/2, Max Time Delay Breaker or Fuse: 15, Nominal FLA: 8.4, Trans (VA): 40, Approx Shipping Weight (Lbs): 160, Cabinet Width (In): 21.0, Blower Drive: High Efficiency
Voltage: 120/60/1, CFM: 5 Ton add on cooling, Stages: Single, Nominal Cooling Capacity: 3 - 5, Configuration: Upflow/Horizontal, Input (Btuh): 110,000, Output (Btuh): 106,000, AFUE (ICS): 95.0%, Gas Inlet (In): 1/2, Max Time Delay Breaker or Fuse: 15, Nominal FLA: 10.9, Trans (VA): 40, Approx Shipping Weight (Lbs): 170, Cabinet Width (In): 21.0, Blower Drive: High Efficiency
Voltage: 120/60/1, CFM: 5 Ton add on cooling, Stages: Single, Nominal Cooling Capacity: 3-1/2 - 5, Configuration: Upflow/Horizontal, Input (Btuh): 132,000, Output (Btuh): 126,000, AFUE (ICS): 95.0%, Gas Inlet (In): 1/2, Max Time Delay Breaker or Fuse: 15, Nominal FLA: 10.9, Trans (VA): 40, Approx Shipping Weight (Lbs): 187, Cabinet Width (In): 24.5, Blower Drive: High Efficiency
Voltage: 120/60/1, CFM: 3 Ton add on cooling, Stages: Single, Nominal Cooling Capacity: 1-1/2 - 3, Configuration: Downflow, Input (Btuh): 44,000, Output (Btuh): 42,000, AFUE (ICS): 95.0%, Gas Inlet (In): 1/2, Max Time Delay Breaker or Fuse: 15, Nominal FLA: 6.8, Trans (VA): 40, Approx Shipping Weight (Lbs): 131, Cabinet Width (In): 17.5, Blower Drive: High Efficiency
Voltage: 120/60/1, CFM: 4 Ton add on cooling, Stages: Single, Nominal Cooling Capacity: 2-1/2 - 4, Configuration: Downflow, Input (Btuh): 66,000, Output (Btuh): 64,000, AFUE (ICS): 95.0%, Gas Inlet (In): 1/2, Max Time Delay Breaker or Fuse: 15, Nominal FLA: 8.4, Trans (VA): 40, Approx Shipping Weight (Lbs): 146, Cabinet Width (In): 17.5, Blower Drive: High Efficiency
Voltage: 120/60/1, CFM: 4 Ton add on cooling, Stages: Single, Nominal Cooling Capacity: 2-1/2 - 4, Configuration: Downflow, Input (Btuh): 88,000, Output (Btuh): 85,000, AFUE (ICS): 95.0%, Gas Inlet (In): 1/2, Max Time Delay Breaker or Fuse: 15, Nominal FLA: 8.4, Trans (VA): 40, Approx Shipping Weight (Lbs): 162, Cabinet Width (In): 21.0, Blower Drive: High Efficiency
Voltage: 120/60/1, CFM: 5 Ton add on cooling, Stages: Single, Nominal Cooling Capacity: 3 - 5, Configuration: Downflow, Input (Btuh): 110,000, Output (Btuh): 106,000, AFUE (ICS): 95.0%, Gas Inlet (In): 1/2, Max Time Delay Breaker or Fuse: 15, Nominal FLA: 10.9, Trans (VA): 40, Approx Shipping Weight (Lbs): 174, Cabinet Width (In): 21.0, Blower Drive: High Efficiency
Product Image Not Available95G1UH045BP12 UP/HORZ 45K BTU 1200 CFM FURN
Locke Part #: L8250MFG Part #: 67W56 PD00144170 Compare
Product Image Not Available95G1UH070BP12 UP/HORZ 70K BTU 1200 CFM FURN
Locke Part #: L8251MFG Part #: 67W58 PD00144170 Compare
Product Image Not Available95G1UH090CP16 UP/HORZ 90K BTU 1600 CFM FURN
Locke Part #: L8253MFG Part #: 67W60 PD00144170 Compare
Product Image Not Available95G1UH110CP20 UP/HORZ 110K BTU 2000 CFM FURN
Locke Part #: L8255MFG Part #: 67W62 PD00144170 Compare
Voltage: 208-230/60/1, Blower Motor: Constant Torque, Weight (Lbs): 122, Metering Device: Piston Orifice, Nominal Capacity: 24,000 Btuh, Configuration: Multi-position (Upflow, Horizontal Right or Left), Max Elec Heat Available (kW): 10kW, Transformer Size & Type: 40 VA Class 2, Refrigerant Connection IDS - Suction (In): 3/4, Refrigerant Connection IDS - Liquid (In): 3/8, Filter Size (In): 15 x 20, Circuit Protection: None Application, 1-1/2 - 5 ton sizes, Upflow and horizontal, Sequenced for demand management, External access to heater circuit breakers, Installation, 1 Piece design for easier installation, Multiposition - Upflow/Horizontal Left/Right, Unit approved for installation in manufactured housing and mobile homes, Cabinet, Foil faced insulation, Painted, heavy-gauge galvanized cabinet, High-strength, UV- and heat-resistant plastic drain pan for corrosion resistance, 2% or less air leakage, Components, Efficient PSC blower motors, Standard transformer and blower relay, Field-installed 2.5-20 kW electric heat kits with easy plug connections, Built-in indoor time delay for increased efficiency, Accessories, Counter flow Kit, Single point power kit, Warranty, 10-year limited parts warranty available when applied with a system
Voltage: 208-230/60/1, Blower Motor: Constant Torque, Weight (Lbs): 125, Metering Device: Piston Orifice, Nominal Capacity: 30,000 Btuh, Configuration: Multi-position (Upflow, Horizontal Right or Left), Max Elec Heat Available (kW): 12.5kW, Transformer Size & Type: 40 VA Class 2, Refrigerant Connection IDS - Suction (In): 3/4, Refrigerant Connection IDS - Liquid (In): 3/8, Filter Size (In): 15 x 20, Circuit Protection: None Application, 1-1/2 - 5 ton sizes, Upflow and horizontal, Sequenced for demand management, External access to heater circuit breakers, Installation, 1 Piece design for easier installation, Multiposition - Upflow/Horizontal Left/Right, Unit approved for installation in manufactured housing and mobile homes, Cabinet, Foil faced insulation, Painted, heavy-gauge galvanized cabinet, High-strength, UV- and heat-resistant plastic drain pan for corrosion resistance, 2% or less air leakage, Components, Efficient PSC blower motors, Standard transformer and blower relay, Field-installed 2.5-20 kW electric heat kits with easy plug connections, Built-in indoor time delay for increased efficiency, Accessories, Counter flow Kit, Single point power kit, Warranty, 10-year limited parts warranty available when applied with a system
Voltage: 208-230/60/1, Blower Motor: Constant Torque, Weight (Lbs): 160, Metering Device: Piston Orifice, Nominal Capacity: 36,000 Btuh, Configuration: Multi-position (Upflow, Horizontal Right or Left), Max Elec Heat Available (kW): 15kW, Transformer Size & Type: 40 VA Class 2, Refrigerant Connection IDS - Suction (In): 7/8, Refrigerant Connection IDS - Liquid (In): 3/8, Filter Size (In): 18 x 20, Circuit Protection: None Application, 1-1/2 - 5 ton sizes, Upflow and horizontal, Sequenced for demand management, External access to heater circuit breakers, Installation, 1 Piece design for easier installation, Multiposition - Upflow/Horizontal Left/Right, Unit approved for installation in manufactured housing and mobile homes, Cabinet, Foil faced insulation, Painted, heavy-gauge galvanized cabinet, High-strength, UV- and heat-resistant plastic drain pan for corrosion resistance, 2% or less air leakage, Components, Efficient PSC blower motors, Standard transformer and blower relay, Field-installed 2.5-20 kW electric heat kits with easy plug connections, Built-in indoor time delay for increased efficiency, Accessories, Counter flow Kit, Single point power kit, Warranty, 10-year limited parts warranty available when applied with a system
Voltage: 208-230/60/1, Blower Motor: Constant Torque, Weight (Lbs): 162, Metering Device: Piston Orifice, Nominal Capacity: 42,000 Btuh, Configuration: Multi-position (Upflow, Horizontal Right or Left), Max Elec Heat Available (kW): 15kW, Transformer Size & Type: 40 VA Class 2, Refrigerant Connection IDS - Suction (In): 7/8, Refrigerant Connection IDS - Liquid (In): 3/8, Filter Size (In): 18 x 24, Circuit Protection: None Application, 1-1/2 - 5 ton sizes, Upflow and horizontal, Sequenced for demand management, External access to heater circuit breakers, Installation, 1 Piece design for easier installation, Multiposition - Upflow/Horizontal Left/Right, Unit approved for installation in manufactured housing and mobile homes, Cabinet, Foil faced insulation, Painted, heavy-gauge galvanized cabinet, High-strength, UV- and heat-resistant plastic drain pan for corrosion resistance, 2% or less air leakage, Components, Efficient PSC blower motors, Standard transformer and blower relay, Field-installed 2.5-20 kW electric heat kits with easy plug connections, Built-in indoor time delay for increased efficiency, Accessories, Counter flow Kit, Single point power kit, Warranty, 10-year limited parts warranty available when applied with a system
Voltage: 208-230/60/1, Blower Motor: Constant Torque, Weight (Lbs): 185, Metering Device: Piston Orifice, Nominal Capacity: 48,000 Btuh, Configuration: Multi-position (Upflow, Horizontal Right or Left), Max Elec Heat Available (kW): 20kW, Transformer Size & Type: 40 VA Class 2, Refrigerant Connection IDS - Suction (In): 7/8, Refrigerant Connection IDS - Liquid (In): 3/8, Filter Size (In): 18 x 24, Circuit Protection: None Application, 1-1/2 - 5 ton sizes, Upflow and horizontal, Sequenced for demand management, External access to heater circuit breakers, Installation, 1 Piece design for easier installation, Multiposition - Upflow/Horizontal Left/Right, Unit approved for installation in manufactured housing and mobile homes, Cabinet, Foil faced insulation, Painted, heavy-gauge galvanized cabinet, High-strength, UV- and heat-resistant plastic drain pan for corrosion resistance, 2% or less air leakage, Components, Efficient PSC blower motors, Standard transformer and blower relay, Field-installed 2.5-20 kW electric heat kits with easy plug connections, Built-in indoor time delay for increased efficiency, Accessories, Counter flow Kit, Single point power kit, Warranty, 10-year limited parts warranty available when applied with a system
Product Image Not Available80G1UH045AE12 UP/HORZ 80% 45K BTU C.T. FURNACE
Locke Part #: L8276MFG Part #: 85W38 Compare
Product Image Not Available80G1UH070BE12 UP/HORZ 80% 70K BTU C.T. FURNACE
Locke Part #: L8277MFG Part #: 85W39 Compare
Product Image Not Available80G1UH090BE16 UP/HORZ 80% 90K BTU C.T. FURNACE
Locke Part #: L8278MFG Part #: 85W40 Compare
Product Image Not Available80G1UH110CE20 UP/HORZ 80% 110K BTU C.T FURNACE
Locke Part #: L8280MFG Part #: 85W42 Compare
Product Image Not Available80G1DF110CE20 DOWNFLOW 80% 110K BTU FURNACE
Locke Part #: L8285MFG Part #: 85W47 Compare