P0634.jpg 2-2-4 AWG, Type SE, Style U Wire, 500’ Reel
Locke Part #: P0634MFG Part #: 103151611240
Allowable Ampacity (Amps): (1)130, (2)125, Approximate Net Weight (lbs/1000 ft): 668, Ground/Neutral Conductor Stranding (No of Wires): 12, Insulated Conductor Size (AWG): 2-2-4, Insulated Conductor Stranding (No of Wires): 7, Nominal Dimensions (in): 0.600 x 1.000, Package NR Reels (ft): 500’, Size Ground/Neutral Conductor (AWG): 4, Standard Coils (ft): 100’ Construction:, Conductors:, Solid: Bare, soft copper per ASTM-B3, 7-strand: Class B concentrically stranded per ASTM-B8, 19-strand: Combination unilay conductors per ASTM-B787, Insulation:, High dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC) rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN or THWN wire., Conductor Jacket, :, Clear Nylon sheath meeting the requirements of UL-83 for THHN or THWN., Ground/Neutral Conductor, :, Soft drawn annealed copper conductors., Sizes smaller than 3 AWG have a round, stranded bare ground/neutral conductor laid parallel between the insulated conductors., Sizes 3 AWG and larger have bare concentric ground/neutral wires wrapped helically over the insulated conductors., Applications:, This cable is manufactured in accordance with Article 338 of the NEC and also the requirements of Underwriters Laboratories Standard 854., Type SE Style U is approved for installation in accordance with Article 230 of the NEC and has a rating of 600 volts., Assembly, :, Overall Jacket, :, Extruded, protective sunlight-resistant gray PVC jacket over the taped assembly in accordance with UL Standard 854., Standards:, Underwriters Laboratories Standards UL-83, UL-854, Federal Specification AA59544, National Electrical Code Articles 338 & 230, NEMA RV4 2009, ARRA 2009; Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 15, Approximate Net Weight (lbs/1000 ft): 53, Ground Wire Size (AWG): 14, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Jacket Thickness (in): 0.030, Number of Strands: Solid, Outside Diameter (in): 0.185 x 0.385, Size (AWG) and Number of Conductors: 14/2G, Standard Packaging (ft): 1000’ Reel Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant
P0634.jpg 4-4-4 AWG, Type SE Style U Wire, 500’ Reel
Locke Part #: P0682MFG Part #: 103141411240
Allowable Ampacity (Amps): (1)95, (2)100, Approximate Net Weight (lbs/1000 ft): 494, Ground/Neutral Conductor Stranding (No of Wires): 7, Insulated Conductor Size (AWG): 4-4-4, Insulated Conductor Stranding (No of Wires): 7, Nominal Dimensions (in): 0.540 x 0.870, Package NR Reels (ft): 500’, Size Ground/Neutral Conductor (AWG): 4, Standard Coils (ft): 150’ Construction:, Conductors:, Solid: Bare, soft copper per ASTM-B3, 7-strand: Class B concentrically stranded per ASTM-B8, 19-strand: Combination unilay conductors per ASTM-B787, Insulation:, High dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC) rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN or THWN wire., Conductor Jacket, :, Clear Nylon sheath meeting the requirements of UL-83 for THHN or THWN., Ground/Neutral Conductor, :, Soft drawn annealed copper conductors., Sizes smaller than 3 AWG have a round, stranded bare ground/neutral conductor laid parallel between the insulated conductors., Sizes 3 AWG and larger have bare concentric ground/neutral wires wrapped helically over the insulated conductors., Applications:, This cable is manufactured in accordance with Article 338 of the NEC and also the requirements of Underwriters Laboratories Standard 854., Type SE Style U is approved for installation in accordance with Article 230 of the NEC and has a rating of 600 volts., Assembly, :, Overall Jacket, :, Extruded, protective sunlight-resistant gray PVC jacket over the taped assembly in accordance with UL Standard 854., Standards:, Underwriters Laboratories Standards UL-83, UL-854, Federal Specification AA59544, National Electrical Code Articles 338 & 230, NEMA RV4 2009, ARRA 2009; Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 15, Approximate Net Weight (lbs/1000 ft): 74, Ground Wire Size (AWG): 14, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.170 x 0.450, Size (AWG) and Number of Conductors: 14/3G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Color: Yellow, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers
Color: Orange, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers
P0686.jpg 8 AWG, Solid, Bare Copper Wire, 500’ Reel
Locke Part #: P0686MFG Part #: 170101000040
Outside Diameter: 0.1285" (3.26 mm), Approximate Net Weight (lbs/1000 ft): 50.0, Number of Strands: Solid, Standard Packaging (ft): 500’, Area (cmils): 16,510, Size (AWG): 8, Soft-Drawn (Annealed) - DC Resistance (Ohms/1000 ft @ 20°C): 0.6407, Soft-Drawn (Annealed) - Rated Strength (lbs): 479 Highest conductivity per unit area of all common commercial metals., Excellent corrosion resistance., Flexible; easily worked and formed into place., Packaged on non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installations., Good fatigue-resistance; not subject to breaks due to nicks or cuts when terminating., Totally recyclable with high scrap value., Contact your local representative for information on the Encore Wire Scrap Purchase Program., Construction:, Soft-Drawn Solid or Stranded, Annealed Bare Copper., Applications:, Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding., Standards:, ASTM-B3 for soft-drawn solid copper wire., ASTM-B8 for soft-drawn concentric lay stranded copper wire., ASTM-B787 for 19-wire combination unilay stranded wire., ARRA 2009; Section 1605 "Buy American" Compliant.
Color: Red-White, Approximate Net Weight (lbs/1000 ft): 106, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/2, Green Ground: 12 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.487 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Blue-White, Approximate Net Weight (lbs/1000 ft): 106, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/2, Green Ground: 12 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.487 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Black-White, Approximate Net Weight (lbs/1000 ft): 106, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/2, Green Ground: 12 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.487 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Black-White-Red, Approximate Net Weight (lbs/1000 ft): 132, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/3, Green Ground: 12 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.495 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Black-White, Approximate Net Weight (lbs/1000 ft): 110, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/2, Green Ground: 12 AWG, Conductors - Type: Stranded, Overall Diameter (in): 0.487 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., Larger sizes are supplied with a bare ground conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5)., Standards:
Allowable Ampacity (Amps): 70, Approximate Net Weight (lbs/1000 ft): 565, Ground Wire Size (AWG): 8, Insulation Thickness (in): PVC: 0.040, Nylon: 0.006, Number of Strands: 7, Outside Diameter (in): 0.820, Size (AWG) and Number of Conductors: 4/3G, Standard Packaging (ft): 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 70, Approximate Net Weight (lbs/1000 ft): 565, Ground Wire Size (AWG): 8, Insulation Thickness (in): PVC: 0.040, Nylon: 0.006, Number of Strands: 7, Outside Diameter (in): 0.820, Size (AWG) and Number of Conductors: 4/3G, Standard Packaging (ft): 125’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Color: Pink, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Yellow, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Orange, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Purple, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Brown, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Allowable Ampacity (Amps): 15, Approximate Net Weight (lbs/1000 ft): 56, Ground Wire Size (AWG): 14, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.170 x 0.390, Size (AWG) and Number of Conductors: 14/2G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 82, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (OD): 0.16 x 0.45, Size (AWG) and Number of Conductors: 12/2G, Standard Packaging: 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 107, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.345, Size (AWG) and Number of Conductors: 12/3G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 123, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.210 x 0.493, Size (AWG) and Number of Conductors: 10/2G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 40, Approximate Net Weight (lbs/1000 ft): 185, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.290 x 0.580, Size (AWG) and Number of Conductors: 8/2G, Standard Packaging (ft): 125’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 40, Approximate Net Weight (lbs/1000 ft): 251, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.555, Size (AWG) and Number of Conductors: 8/3G, Standard Packaging (ft): 125’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 55, Approximate Net Weight (lbs/1000 ft): 256, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.330 x 0.695, Size (AWG) and Number of Conductors: 6/2G, Standard Packaging (ft): 125’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 55, Approximate Net Weight (lbs/1000 ft): 352, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.612, Size (AWG) and Number of Conductors: 6/3G, Standard Packaging (ft): 125’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Color: Blue, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Gray, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Allowable Ampacity (Amps): 15, Approximate Net Weight (lbs/1000 ft): 53, Ground Wire Size (AWG): 14, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Jacket Thickness (in): 0.030, Number of Strands: Solid, Outside Diameter (in): 0.185 x 0.385, Size (AWG) and Number of Conductors: 14/2G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 75, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Jacket Thickness (in): 0.030, Number of Strands: Solid, Outside Diameter (in): 0.195 x 0.415, Size (AWG) and Number of Conductors: 12/2G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 140, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Jacket Thickness (in): 0.030, Number of Strands: Solid, Outside Diameter (in): 0.230 x 0.460, Size (AWG) and Number of Conductors: 10/2G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant
Allowable Ampacity (Amps): 40, Approximate Net Weight (lbs/1000 ft): 213, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Jacket Thickness (in): 0.045, Number of Strands: 7, Outside Diameter (in): 0.320 x 0.620, Size (AWG) and Number of Conductors: 8/2G, Standard Packaging (ft): 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant
Color: Brown, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers
Allowable Ampacity (Amps): 16, Approximate Net Weight (lbs/1000 ft): 132, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.385, Size (AWG) and Number of Conductors: 12/2-2G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Color: Gray, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers
Color: Blue, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Green, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Outside Diameter: 0.248" (6.30 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 55, Allowable Ampacities (amps) @ 75°C: 65, Allowable Ampacities (amps) @ 90°C: 75, Size (AWG): 6, Approximate Net Weight: 94 lbs/1000 Ft (141 kg/km), Cross Sect Area (mm²): 13.30, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 165, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.430, Size (AWG) and Number of Conductors: 10/3G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Color: Black-White-Red-Blue, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/4, Conductors - Type: Solid, Ground: 10 Solid AL, Outside Diameter Over Armor (in): 0.506, Total Weight of Type MC - Copper Conductor (lbs/1000 ft): 148 Construction:, Conductors:, Available in sizes 14 AWG through 10 AWG. Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry., All conductors are individually wrapped with flame retardant colored protective paper with print legend and cabled together to form the cable core., The bare aluminum grounding/bonding conductor is located outside the paper wrap and is cabled with the insulated conductors and in constant contact with sheathing,, Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Permitted in Class I Div. 2, Class II Div. 2, and Class III Div. 1 Hazardous Locations., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Allowable installations in approved raceways and cable trays (NEC 392)., Suitable for installation under raised floors for IT equipment (NEC 645.5)., Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems., Standards:
Color: Black-White, Approximate Net Weight (lbs/1000 ft): 80, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, AWG/No: 14/2, Green Ground: 14 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.409 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Black-White, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, AWG/No: 10/2, Conductors - Type: Solid, Ground: 8 Solid AL, Outside Diameter Over Armor (in): 0.502, Total Weight of Type MC - Copper Conductor (lbs/1000 ft): 133 Construction:, Conductors:, Available in sizes 14 AWG through 10 AWG. Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry., All conductors are individually wrapped with flame retardant colored protective paper with print legend and cabled together to form the cable core., The bare aluminum grounding/bonding conductor is located outside the paper wrap and is cabled with the insulated conductors and in constant contact with sheathing,, Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Permitted in Class I Div. 2, Class II Div. 2, and Class III Div. 1 Hazardous Locations., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Allowable installations in approved raceways and cable trays (NEC 392)., Suitable for installation under raised floors for IT equipment (NEC 645.5)., Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems., Standards:
Color: Black, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: White, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Red, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Green, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: White, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Red, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Blue, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Gray, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black-White, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, AWG/No: 10/2, Conductors - Type: Solid, Ground: 8 Solid AL, Outside Diameter Over Armor (in): 0.502, Total Weight of Type MC - Copper Conductor (lbs/1000 ft): 133 Construction:, Conductors:, Available in sizes 14 AWG through 10 AWG. Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry., All conductors are individually wrapped with flame retardant colored protective paper with print legend and cabled together to form the cable core., The bare aluminum grounding/bonding conductor is located outside the paper wrap and is cabled with the insulated conductors and in constant contact with sheathing,, Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Permitted in Class I Div. 2, Class II Div. 2, and Class III Div. 1 Hazardous Locations., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Allowable installations in approved raceways and cable trays (NEC 392)., Suitable for installation under raised floors for IT equipment (NEC 645.5)., Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems., Standards:
Color: Green, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
P0723 THHN 600V.jpg 4 AWG, Stranded, Black THHN Wire, 500’ Reel
Locke Part #: P0749MFG Part #: 118101401440
Color: Black, Outside Diameter: 0.317" (8.06 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 70, Allowable Ampacities (amps) @ 75°C: 85, Allowable Ampacities (amps) @ 90°C: 95, Size (AWG): 4, Approximate Net Weight: 153 lbs/1000ft (228 kg/km), Cross Sect Area (mm²): 21.20, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Pink, Standard Packaging: 2000’ carton (4 x 500’), 2500’ reels, Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: 19, Outside Diameter (in): 0.127, Cross Sect Area (mm²): 3.31, Allowable Ampacity (Amps) 60°C / 75°C / 90°C: 20 / 25 / 30, Diameter of Bare Copper (in): 0.0880, Nylon Jacket Thickness (in): 0.004, PVC Insulation Thickness (Conductor) (in): 0.015, Size (AWG or KCMIL): 12 Applications:, C or not to exceed 75 C in oil or coolants. For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3 Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83, Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: White, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Red, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Green, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Yellow, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black-White, Approximate Net Weight (lbs/1000 ft): 153, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, AWG/No: 10/2, Green Ground: 10 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.510 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Black-White, Approximate Net Weight (lbs/1000 ft): 153, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, AWG/No: 10/2, Green Ground: 10 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.510 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Outside Diameter: 0.2920" (7.42 mm), Approximate Net Weight (lbs/1000 ft): 205, Number of Strands: 7, Standard Packaging (ft): 125’, Area (cmils): 66,360, Size (AWG): 2, Soft-Drawn (Annealed) - DC Resistance (Ohms/1000 ft @ 20°C): 0.1590, Soft-Drawn (Annealed) - Rated Strength (lbs): 2,110 Highest conductivity per unit area of all common commercial metals., Excellent corrosion resistance., Flexible; easily worked and formed into place., Packaged on non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installations., Good fatigue-resistance; not subject to breaks due to nicks or cuts when terminating., Totally recyclable with high scrap value., Contact your local representative for information on the Encore Wire Scrap Purchase Program., Construction:, Soft-Drawn Solid or Stranded, Annealed Bare Copper., Applications:, Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding., Standards:, ASTM-B3 for soft-drawn solid copper wire., ASTM-B8 for soft-drawn concentric lay stranded copper wire., ASTM-B787 for 19-wire combination unilay stranded wire., ARRA 2009; Section 1605 "Buy American" Compliant.
Allowable Ampacity (Amps): 55, Approximate Net Weight (lbs/1000 ft): 256, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.330 x 0.695, Size (AWG) and Number of Conductors: 6/2G, Standard Packaging (ft): 1000’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 40, Approximate Net Weight (lbs/1000 ft): 185, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.290 x 0.580, Size (AWG) and Number of Conductors: 8/2G, Standard Packaging (ft): 1000’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 82, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.160 x 0.450, Size (AWG) and Number of Conductors: 12/2G, Standard Packaging (ft): 1000’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 123, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.210 x 0.493, Size (AWG) and Number of Conductors: 10/2G, Standard Packaging (ft): 1000’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 165, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.430, Size (AWG) and Number of Conductors: 10/3G, Standard Packaging (ft): 1000’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 40, Approximate Net Weight (lbs/1000 ft): 251, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.555, Size (AWG) and Number of Conductors: 8/3G, Standard Packaging (ft): 1000’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
P0686.jpg 6 AWG, Solid, Bare Copper Wire, 315’ Reel
Locke Part #: P0770MFG Part #: 170101200035
Outside Diameter: 0.1620" (4.12 mm), Approximate Net Weight (lbs/1000 ft): 79.5, Number of Strands: Solid, Standard Packaging (ft): 315’, Area (cmils): 26,240, Size (AWG): 6, Soft-Drawn (Annealed) - DC Resistance (Ohms/1000 ft @ 20°C): 0.4031, Soft-Drawn (Annealed) - Rated Strength (lbs): 762 Highest conductivity per unit area of all common commercial metals., Excellent corrosion resistance., Flexible; easily worked and formed into place., Packaged on non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installations., Good fatigue-resistance; not subject to breaks due to nicks or cuts when terminating., Totally recyclable with high scrap value., Contact your local representative for information on the Encore Wire Scrap Purchase Program., Construction:, Soft-Drawn Solid or Stranded, Annealed Bare Copper., Applications:, Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding., Standards:, ASTM-B3 for soft-drawn solid copper wire., ASTM-B8 for soft-drawn concentric lay stranded copper wire., ASTM-B787 for 19-wire combination unilay stranded wire., ARRA 2009; Section 1605 "Buy American" Compliant.
P0686.jpg 4 AWG, Solid, Bare Copper Wire, 200’ Reel
Locke Part #: P0771MFG Part #: 170101400125
Outside Diameter: 0.2043" (5.19 mm), Approximate Net Weight (lbs/1000 ft): 126.4, Number of Strands: Solid, Standard Packaging (ft): 200’, Area (cmils): 41,740, Size (AWG): 4, Soft-Drawn (Annealed) - DC Resistance (Ohms/1000 ft @ 20°C): 0.2535, Soft-Drawn (Annealed) - Rated Strength (lbs): 1,214 Highest conductivity per unit area of all common commercial metals., Excellent corrosion resistance., Flexible; easily worked and formed into place., Packaged on non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installations., Good fatigue-resistance; not subject to breaks due to nicks or cuts when terminating., Totally recyclable with high scrap value., Contact your local representative for information on the Encore Wire Scrap Purchase Program., Construction:, Soft-Drawn Solid or Stranded, Annealed Bare Copper., Applications:, Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding., Standards:, ASTM-B3 for soft-drawn solid copper wire., ASTM-B8 for soft-drawn concentric lay stranded copper wire., ASTM-B787 for 19-wire combination unilay stranded wire., ARRA 2009; Section 1605 "Buy American" Compliant.
P0723 THHN 600V.jpg 3 AWG, Stranded, Black THHN Wire, 500’ Reel
Locke Part #: P0772MFG Part #: 118101501440
Color: Black, Outside Diameter: 0.344" (8.74 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 85, Allowable Ampacities (amps) @ 75°C: 100, Allowable Ampacities (amps) @ 90°C: 110, Size (AWG): 3, Approximate Net Weight: 189 lbs/1000ft (281 kg/km), Cross Sect Area (mm²): 26.70, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723 THHN 600V.jpg 2 AWG, Stranded, Black THHN Wire, 500’ Reel
Locke Part #: P0773MFG Part #: 118101601440
Color: Black, Outside Diameter: 0.375" (9.53 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 95, Allowable Ampacities (amps) @ 75°C: 115, Allowable Ampacities (amps) @ 90°C: 130, Size (AWG): 2, Approximate Net Weight: 233 lbs/1000ft (348 kg/km), Cross Sect Area (mm²): 33.60, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Purple, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers
Color: Blue, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers
Color: Green, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers
Color: Black, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers
Color: White, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers
Color: Red, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers
Color: Black, Outside Diameter: 0.474" (12.04 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 125, Allowable Ampacities (amps) @ 75°C: 150, Allowable Ampacities (amps) @ 90°C: 170, Size (AWG): 1/0, Approximate Net Weight: 372 lbs/1000ft (554 kg/km), Cross Sect Area (mm²): 53.50, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Outside Diameter: 0.518" (13.16 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 145, Allowable Ampacities (amps) @ 75°C: 175, Allowable Ampacities (amps) @ 90°C: 195, Size (AWG): 2/0, Approximate Net Weight: 462 lbs/1000ft (687 kg/km), Cross Sect Area (mm²): 67.40, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Outside Diameter: 0.568" (14.43 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 165, Allowable Ampacities (amps) @ 75°C: 200, Allowable Ampacities (amps) @ 90°C: 225, Size (AWG): 3/0, Approximate Net Weight: 572 lbs/1000ft (851 kg/km), Cross Sect Area (mm²): 85.00, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Outside Diameter: 0.624" (15.85 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 195, Allowable Ampacities (amps) @ 75°C: 230, Allowable Ampacities (amps) @ 90°C: 260, Size (AWG): 4/0, Approximate Net Weight: 702 lbs/1000ft (1059 kg/km), Cross Sect Area (mm²): 107.00, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Outside Diameter: 0.212" (5.39 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 40, Allowable Ampacities (amps) @ 75°C: 50, Allowable Ampacities (amps) @ 90°C: 55, Size (AWG): 8, Approximate Net Weight: 62 lbs/1000 Ft (94 kg/km), Cross Sect Area (mm²): 8.37, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: White, Outside Diameter: 0.212" (5.39 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 40, Allowable Ampacities (amps) @ 75°C: 50, Allowable Ampacities (amps) @ 90°C: 55, Size (AWG): 8, Approximate Net Weight: 62 lbs/1000 Ft (94 kg/km), Cross Sect Area (mm²): 8.37, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723 THHN 600V.jpg 1 AWG, Stranded, Black THHN Wire, 500’ Reel
Locke Part #: P0789MFG Part #: 118101701440
Color: Black, Outside Diameter: 0.435" (11.05 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 110, Allowable Ampacities (amps) @ 75°C: 130, Allowable Ampacities (amps) @ 90°C: 150, Size (AWG): 1, Approximate Net Weight: 298 lbs/1000ft (445 kg/km), Cross Sect Area (mm²): 42.40, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 107, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.345, Size (AWG) and Number of Conductors: 12/3G, Standard Packaging (ft): 1000’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Color: Black-White-Red, Approximate Net Weight (lbs/1000 ft): 193, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, AWG/No: 10/3, Green Ground: 10 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.549 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Black-White-Red, Approximate Net Weight (lbs/1000 ft): 193, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, AWG/No: 10/3, Green Ground: 10 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.549 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: White, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
P0723 THHN 600V.jpg 4 AWG, Stranded, Green THHN Wire, 1000’ Reel
Locke Part #: P0806MFG Part #: 118101405450
Color: Green, Outside Diameter: 0.317" (8.06 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 70, Allowable Ampacities (amps) @ 75°C: 85, Allowable Ampacities (amps) @ 90°C: 95, Size (AWG): 4, Approximate Net Weight: 153 lbs/1000ft (228 kg/km), Cross Sect Area (mm²): 21.20, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Red, Outside Diameter: 0.212" (5.39 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 40, Allowable Ampacities (amps) @ 75°C: 50, Allowable Ampacities (amps) @ 90°C: 55, Size (AWG): 8, Approximate Net Weight: 62 lbs/1000 Ft (94 kg/km), Cross Sect Area (mm²): 8.37, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Green, Outside Diameter: 0.212" (5.39 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 40, Allowable Ampacities (amps) @ 75°C: 50, Allowable Ampacities (amps) @ 90°C: 55, Size (AWG): 8, Approximate Net Weight: 62 lbs/1000 Ft (94 kg/km), Cross Sect Area (mm²): 8.37, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723 THHN 600V.jpg 3 AWG, Stranded, White THHN Wire, 500’ Reel
Locke Part #: P0834MFG Part #: 118101502440
Color: White, Outside Diameter: 0.344" (8.74 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 85, Allowable Ampacities (amps) @ 75°C: 100, Allowable Ampacities (amps) @ 90°C: 110, Size (AWG): 3, Approximate Net Weight: 189 lbs/1000ft (281 kg/km), Cross Sect Area (mm²): 26.70, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: White, Outside Diameter: 0.474" (12.04 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 125, Allowable Ampacities (amps) @ 75°C: 150, Allowable Ampacities (amps) @ 90°C: 170, Size (AWG): 1/0, Approximate Net Weight: 372 lbs/1000ft (554 kg/km), Cross Sect Area (mm²): 53.50, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: White, Outside Diameter: 0.568" (14.43 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 165, Allowable Ampacities (amps) @ 75°C: 200, Allowable Ampacities (amps) @ 90°C: 225, Size (AWG): 3/0, Approximate Net Weight: 572 lbs/1000ft (851 kg/km), Cross Sect Area (mm²): 85.00, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Yellow, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Brown, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Orange, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Allowable Ampacity (Amps): 40, Approximate Net Weight (lbs/1000 ft): 185, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.290 x 0.580, Size (AWG) and Number of Conductors: 8/2G, Standard Packaging (ft): 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 40, Approximate Net Weight (lbs/1000 ft): 213, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Jacket Thickness (in): 0.045, Number of Strands: 7, Outside Diameter (in): 0.320 x 0.620, Size (AWG) and Number of Conductors: 8/2G, Standard Packaging (ft): 1000’ Reel Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant
Allowable Ampacity (Amps): 40, Approximate Net Weight (lbs/1000 ft): 330, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Jacket Thickness (in): 0.045, Number of Strands: 7, Outside Diameter (in): 0.320 x 0.990, Size (AWG) and Number of Conductors: 8/3G, Standard Packaging (ft): 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 140, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Jacket Thickness (in): 0.030, Number of Strands: Solid, Outside Diameter (in): 0.230 x 0.460, Size (AWG) and Number of Conductors: 10/2G, Standard Packaging (ft): 1000’ Reel Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 194, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Jacket Thickness (in): 0.030, Number of Strands: Solid, Outside Diameter (in): 0.230 x 0.690, Size (AWG) and Number of Conductors: 10/3G, Standard Packaging (ft): 1000’ Reel Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 75, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Jacket Thickness (in): 0.030, Number of Strands: Solid, Outside Diameter (in): 0.195 x 0.415, Size (AWG) and Number of Conductors: 12/2G, Standard Packaging (ft): 1000’ Reel Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 134, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Jacket Thickness (in): 0.030, Number of Strands: Solid, Outside Diameter (in): 0.195 x 0.620, Size (AWG) and Number of Conductors: 12/3G, Standard Packaging (ft): 1000’ Reel Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant
P0723.jpg 1 AWG, Stranded, Black THWN Wire 1000’ Reel
Locke Part #: P0941MFG Part #: 118101701450
Color: Black, Outside Diameter: 0.435" (11.05 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 110, Allowable Ampacities (amps) @ 75°C: 130, Allowable Ampacities (amps) @ 90°C: 150, Size (AWG): 1, Approximate Net Weight: 298 lbs/1000ft (445 kg/km), Cross Sect Area (mm²): 42.40, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Outside Diameter: 0.474" (12.04 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 125, Allowable Ampacities (amps) @ 75°C: 150, Allowable Ampacities (amps) @ 90°C: 170, Size (AWG): 1/0, Approximate Net Weight: 372 lbs/1000ft (554 kg/km), Cross Sect Area (mm²): 53.50, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Outside Diameter: 0.518" (13.16 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 145, Allowable Ampacities (amps) @ 75°C: 175, Allowable Ampacities (amps) @ 90°C: 195, Size (AWG): 2/0, Approximate Net Weight: 462 lbs/1000ft (687 kg/km), Cross Sect Area (mm²): 67.40, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Outside Diameter: 0.568" (14.43 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 165, Allowable Ampacities (amps) @ 75°C: 200, Allowable Ampacities (amps) @ 90°C: 225, Size (AWG): 3/0, Approximate Net Weight: 572 lbs/1000ft (851 kg/km), Cross Sect Area (mm²): 85.00, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Orange, Outside Diameter: 0.210" x 0.493", Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 123, Ground Wire Size (AWG): 10, Conductor - AWG No: 10/2 G, Conductor - Green Ground: 10 AWG, Conductor - Type: Solid, Insulation Thickness (in) - Nylon: 0.004, Insulation Thickness (in) - PVC: 0.020, Packaging (ft): 500’ reels
Approximate Net Weight (lbs/1000 ft): 427, Outside Diameter Over Armor (in): 0.677, Conductor - AWG No: 8/2, Conductor - Green Ground: 10 AWG, Conductor - Type: Stranded, Packaging (ft): 500’ reels, Allowable Ampacity (Amps) - 75°C: 50, Jacket Thickness: 0.050, Outside Diameter Over Jacket (in): 0.892
Approximate Net Weight (lbs/1000 ft): 524, Outside Diameter Over Armor (in): 0.757, Conductor - AWG No: 8/3, Conductor - Green Ground: 10 AWG, Conductor - Type: Stranded, Packaging (ft): 500’ reels, Allowable Ampacity (Amps) - 75°C: 50, Jacket Thickness: 0.050, Outside Diameter Over Jacket (in): 0.957
Approximate Net Weight (lbs/1000 ft): 566, Outside Diameter Over Armor (in): 0.791, Conductor - AWG No: 6/2, Conductor - Green Ground: 8 AWG, Conductor - Type: Stranded, Packaging (ft): 500’ reels, Allowable Ampacity (Amps) - 75°C: 65, Jacket Thickness: 0.050, Outside Diameter Over Jacket (in): 0.974
Approximate Net Weight (lbs/1000 ft): 0, Outside Diameter Over Armor (in): 0.884, Conductor - AWG No: 6/3, Conductor - Green Ground: 8 AWG, Conductor - Type: Stranded, Packaging (ft): 500’ reels, Allowable Ampacity (Amps) - 75°C: 65, Jacket Thickness: 0.050, Outside Diameter Over Jacket (in): 1.045
Color: Orange, Outside Diameter: 0.212" (5.39 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 40, Allowable Ampacities (amps) @ 75°C: 50, Allowable Ampacities (amps) @ 90°C: 55, Size (AWG): 8, Approximate Net Weight: 62 lbs/1000 Ft (94 kg/km), Cross Sect Area (mm²): 8.37, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Yellow, Outside Diameter: 0.212" (5.39 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 40, Allowable Ampacities (amps) @ 75°C: 50, Allowable Ampacities (amps) @ 90°C: 55, Size (AWG): 8, Approximate Net Weight: 62 lbs/1000 Ft (94 kg/km), Cross Sect Area (mm²): 8.37, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Brown, Outside Diameter: 0.212" (5.39 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 40, Allowable Ampacities (amps) @ 75°C: 50, Allowable Ampacities (amps) @ 90°C: 55, Size (AWG): 8, Approximate Net Weight: 62 lbs/1000 Ft (94 kg/km), Cross Sect Area (mm²): 8.37, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Approximate Net Weight (lbs/1000 ft): 241, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 2-2-4, Allowable Ampacities for Direct Burial: 168, Code Name: Stephens, Finished Cable - Outside Diameter (in): 0.869, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.333, Neutral Conductor - Size (AWG): 4, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.388, Phase Conductors - Size (AWG): 2, Phase Conductors - XLPE Thickness (in): 0.060 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 185, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 4-4-4, Allowable Ampacities for Direct Burial: 130, Code Name: Vassar, Finished Cable - Outside Diameter (in): 0.744, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.333, Neutral Conductor - Size (AWG): 4, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.333, Phase Conductors - Size (AWG): 4, Phase Conductors - XLPE Thickness (in): 0.060 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 380, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 1/0-1/0-2, Allowable Ampacities for Direct Burial: 219, Code Name: Brenau, Finished Cable - Outside Diameter (in): 1.111, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.388, Neutral Conductor - Size (AWG): 2, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 10, Phase Conductors - Outside Diameter (in): 0.496, Phase Conductors - Size (AWG): 1/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 471, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 2/0-2/0-1, Allowable Ampacities for Direct Burial: 249, Code Name: Converse, Finished Cable - Outside Diameter (in): 1.200, Neutral Conductor - No of Strands: 8, Neutral Conductor - Outside Diameter (in): 0.459, Neutral Conductor - Size (AWG): 1, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 12, Phase Conductors - Outside Diameter (in): 0.536, Phase Conductors - Size (AWG): 2/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 695, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 4/0-4/0-2/0, Allowable Ampacities for Direct Burial: 322, Code Name: Sweetbriar, Finished Cable - Outside Diameter (in): 1.420, Neutral Conductor - No of Strands: 12, Neutral Conductor - Outside Diameter (in): 0.536, Neutral Conductor - Size (AWG): 2/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 19, Phase Conductors - Outside Diameter (in): 0.635, Phase Conductors - Size (AWG): 4/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 75, Standard Packaging (ft): 500’, Conductor Sizes (AWG): 6-6, Code Name: Shepard, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.259, Phase Conductors - Size (AWG): 6, Bare Neutral Conductor - Finished OD (in): 0.198, Bare Neutral Conductor - No of Strands: 6+1, Bare Neutral Conductor - Rated Strength (lbs): 1190, Bare Neutral Conductor - Size (AWG): 6, Bare Neutral Conductor-Type: ACSR, Ampacity (XLPE): 110, Diameter of Final Construction (in): 0.457, Phase Conductors - Insulation Thickness (in): 0.045 Duplex overhead service drop cable has one black XLPE insulated aluminum conductor cabled around a bare-stranded ACSR 1350 Series alloy supporting neutral with steel support center wire., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation rated 90 C operation wet or dry., Manufactured and tested according to ANSI/ICEA S-76-474., Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts., Insulated conductor is surface printed for identification., Construction:, Conductors:, Insulated Conductor, : Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836., Neutral Conductor, : Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232., Insulation:, Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 C wet or dry., Applications:, Duplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90 C wet or dry., Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure., Suitable for 120-volt aerial service for outdoor lighting or for temporary service at construction sites., Standards:, ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232, ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 436, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 1/0-1/0-1/0, Allowable Ampacities for Direct Burial: 219, Code Name: Bergen, Finished Cable - Outside Diameter (in): 1.111, Neutral Conductor - No of Strands: 10, Neutral Conductor - Outside Diameter (in): 0.496, Neutral Conductor - Size (AWG): 1/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 10, Phase Conductors - Outside Diameter (in): 0.496, Phase Conductors - Size (AWG): 1/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 526, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 2/0-2/0-2/0, Allowable Ampacities for Direct Burial: 249, Code Name: Hunter, Finished Cable - Outside Diameter (in): 1.200, Neutral Conductor - No of Strands: 12, Neutral Conductor - Outside Diameter (in): 0.536, Neutral Conductor - Size (AWG): 2/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 12, Phase Conductors - Outside Diameter (in): 0.536, Phase Conductors - Size (AWG): 2/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 780, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 4/0-4/0-4/0, Allowable Ampacities for Direct Burial: 322, Code Name: Monmouth, Finished Cable - Outside Diameter (in): 1.420, Neutral Conductor - No of Strands: 19, Neutral Conductor - Outside Diameter (in): 0.635, Neutral Conductor - Size (AWG): 4/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 19, Phase Conductors - Outside Diameter (in): 0.635, Phase Conductors - Size (AWG): 4/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 241, Standard Packaging (ft): 500’, Conductor Sizes (AWG): 2-2-4, Allowable Ampacities for Direct Burial: 168, Code Name: Stephens, Finished Cable - Outside Diameter (in): 0.869, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.333, Neutral Conductor - Size (AWG): 4, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.388, Phase Conductors - Size (AWG): 2, Phase Conductors - XLPE Thickness (in): 0.060 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 105, Standard Packaging (ft): 2200’, Conductor Sizes (AWG): 6-6-6, Code Name: Voluta, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.259, Phase Conductors - Size (AWG): 6, Phase Conductors - XLPE Thickness (in): 0.045, Bare Neutral Conductor - Finished OD (in): 0.198, Bare Neutral Conductor - No of Strands: 6+1, Bare Neutral Conductor - Rated Strength (lbs): 1190, Bare Neutral Conductor - Size (AWG): 6, Bare Neutral Conductor-Type: ACSR, Ampacity (XLPE): 110, Diameter of Final Construction (in): 0.558 Triplex overhead service drop cable has two black XLPE insulated aluminum conductors cabled around a bare-stranded ACSR 1350 Series alloy supporting neutral with steel support center wire., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation rated 90 C operation wet or dry., Manufactured and tested according to ANSI/ICEA S-76-474., Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts., Insulated conductors are surface printed for identification., Construction:, Conductors:, Insulated Conductor, : Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836., Neutral Conductor, : Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232., Insulation:, Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 C wet or dry., Applications:, Triplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90 C wet or dry., Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure., Suitable for 120-volt aerial service for outdoor lighting or for temporary service at construction sites., Standards:, ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232; ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 430, Standard Packaging (ft): 1200’, Conductor Sizes (AWG): 1/0-1/0-1/0, Code Name: Neritina, Phase Conductors - No of Strands: 10, Phase Conductors - Outside Diameter (in): 0.456, Phase Conductors - Size (AWG): 1/0, Phase Conductors - XLPE Thickness (in): 0.060, Bare Neutral Conductor - Finished OD (in): 0.398, Bare Neutral Conductor - No of Strands: 6+1, Bare Neutral Conductor - Rated Strength (lbs): 4380, Bare Neutral Conductor - Size (AWG): 1/0, Bare Neutral Conductor-Type: ACSR, Ampacity (XLPE): 200, Diameter of Final Construction (in): 0.980 Triplex overhead service drop cable has two black XLPE insulated aluminum conductors cabled around a bare-stranded ACSR 1350 Series alloy supporting neutral with steel support center wire., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation rated 90 C operation wet or dry., Manufactured and tested according to ANSI/ICEA S-76-474., Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts., Insulated conductors are surface printed for identification., Construction:, Conductors:, Insulated Conductor, : Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836., Neutral Conductor, : Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232., Insulation:, Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 C wet or dry., Applications:, Triplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90 C wet or dry., Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure., Suitable for 120-volt aerial service for outdoor lighting or for temporary service at construction sites., Standards:, ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232; ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 520, Standard Packaging (ft): 1500’, Conductor Sizes (AWG): 2/0-2/0-2/0, Code Name: Runcina, Phase Conductors - No of Strands: 12, Phase Conductors - Outside Diameter (in): 0.496, Phase Conductors - Size (AWG): 2/0, Phase Conductors - XLPE Thickness (in): 0.060, Bare Neutral Conductor - Finished OD (in): 0.447, Bare Neutral Conductor - No of Strands: 6+1, Bare Neutral Conductor - Rated Strength (lbs): 5300, Bare Neutral Conductor - Size (AWG): 2/0, Bare Neutral Conductor-Type: ACSR, Ampacity (XLPE): 230, Diameter of Final Construction (in): 1.066 Triplex overhead service drop cable has two black XLPE insulated aluminum conductors cabled around a bare-stranded ACSR 1350 Series alloy supporting neutral with steel support center wire., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation rated 90 C operation wet or dry., Manufactured and tested according to ANSI/ICEA S-76-474., Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts., Insulated conductors are surface printed for identification., Construction:, Conductors:, Insulated Conductor, : Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836., Neutral Conductor, : Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232., Insulation:, Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 C wet or dry., Applications:, Triplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90 C wet or dry., Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure., Suitable for 120-volt aerial service for outdoor lighting or for temporary service at construction sites., Standards:, ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232; ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 270, Standard Packaging (ft): 1800’, Conductor Sizes (AWG): 2-2-2, Code Name: Conch, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.358, Phase Conductors - Size (AWG): 2, Phase Conductors - XLPE Thickness (in): 0.045, Bare Neutral Conductor - Finished OD (in): 0.316, Bare Neutral Conductor - No of Strands: 6+1, Bare Neutral Conductor - Rated Strength (lbs): 2850, Bare Neutral Conductor - Size (AWG): 2, Bare Neutral Conductor-Type: ACSR, Ampacity (XLPE): 150, Diameter of Final Construction (in): 0.771 Triplex overhead service drop cable has two black XLPE insulated aluminum conductors cabled around a bare-stranded ACSR 1350 Series alloy supporting neutral with steel support center wire., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation rated 90 C operation wet or dry., Manufactured and tested according to ANSI/ICEA S-76-474., Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts., Insulated conductors are surface printed for identification., Construction:, Conductors:, Insulated Conductor, : Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836., Neutral Conductor, : Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232., Insulation:, Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 C wet or dry., Applications:, Triplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90 C wet or dry., Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure., Suitable for 120-volt aerial service for outdoor lighting or for temporary service at construction sites., Standards:, ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232; ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 175, Standard Packaging (ft): 1500’, Conductor Sizes (AWG): 4-4-4, Code Name: Periwinkle, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.303, Phase Conductors - Size (AWG): 4, Phase Conductors - XLPE Thickness (in): 0.045, Bare Neutral Conductor - Finished OD (in): 0.250, Bare Neutral Conductor - No of Strands: 6+1, Bare Neutral Conductor - Rated Strength (lbs): 1860, Bare Neutral Conductor - Size (AWG): 4, Bare Neutral Conductor-Type: ACSR, Ampacity (XLPE): 115, Diameter of Final Construction (in): 0.653 Triplex overhead service drop cable has two black XLPE insulated aluminum conductors cabled around a bare-stranded ACSR 1350 Series alloy supporting neutral with steel support center wire., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation rated 90 C operation wet or dry., Manufactured and tested according to ANSI/ICEA S-76-474., Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts., Insulated conductors are surface printed for identification., Construction:, Conductors:, Insulated Conductor, : Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836., Neutral Conductor, : Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232., Insulation:, Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 C wet or dry., Applications:, Triplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90 C wet or dry., Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure., Suitable for 120-volt aerial service for outdoor lighting or for temporary service at construction sites., Standards:, ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232; ARRA 2009 Section 1605 Buy American Compliant.
Color: Black, Approximate Net Weight (lbs/1000 ft): 90, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 75°C: 90, Allowable Ampacities (amps) @ 90°C: 100, Size (AWG or KCMIL): 2, Approximate Overall Dimensions (in): 0.388, Compact Diameter of Aluminum Conductor (in): 0.268, No of Strands: 7, XLPE Insulation Thickness (in): 0.060 Insulation compound carries VW-1 (vertical wire flame) rating and FT2 (horizontal flame) rating and is sunlight-resistant (6 AWG and larger) in all colors., 1/0 AWG and larger are rated for CT use and comply with IEEE 1202/FT4 Flame Test., When used as RHH or RHW-2, cable complies with ICEA T-29-520 (210,000 Btu/hr) Flame Test., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, Insulation:, Cross-linked polyethylene (XLPE) per UL-854. Sunlight-resistant in all colors 6 AWG and larger, Applications:, Type USE-2, RHH or RHW-2 cables with Aluminum Alloy 8000 Series conductors are suitable for use in conduit and raceways installed underground in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90 C., Permitted for Type USE-2 per UL-854 for applications requiring direct burial., For applications requiring Type RHH or RHW-2, conductor temperatures shall not exceed 90 C in wet or dry locations., Type USE-2, RHH, or RHW-2 is permitted for 600 volt applications., Standards:, Underwriters Laboratories Standards UL-44; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836;, Federal Specification AA-59544; NEMA WC70 / ICEA S-95-658; NEMA RV4 2012; NFPA 70., National Electrical Code (NEC ). ARRA 2009 Section 1605 Buy American Compliant., IEEE 1202/FT4 Flame Test; ICEA T-29-520 (210,000 Btu/hr) Flame Test.
Color: Black, Approximate Net Weight (lbs/1000 ft): 62, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 75°C: 65, Allowable Ampacities (amps) @ 90°C: 75, Size (AWG or KCMIL): 4, Approximate Overall Dimensions (in): 0.333, Compact Diameter of Aluminum Conductor (in): 0.213, No of Strands: 7, XLPE Insulation Thickness (in): 0.060 Insulation compound carries VW-1 (vertical wire flame) rating and FT2 (horizontal flame) rating and is sunlight-resistant (6 AWG and larger) in all colors., 1/0 AWG and larger are rated for CT use and comply with IEEE 1202/FT4 Flame Test., When used as RHH or RHW-2, cable complies with ICEA T-29-520 (210,000 Btu/hr) Flame Test., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, Insulation:, Cross-linked polyethylene (XLPE) per UL-854. Sunlight-resistant in all colors 6 AWG and larger, Applications:, Type USE-2, RHH or RHW-2 cables with Aluminum Alloy 8000 Series conductors are suitable for use in conduit and raceways installed underground in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90 C., Permitted for Type USE-2 per UL-854 for applications requiring direct burial., For applications requiring Type RHH or RHW-2, conductor temperatures shall not exceed 90 C in wet or dry locations., Type USE-2, RHH, or RHW-2 is permitted for 600 volt applications., Standards:, Underwriters Laboratories Standards UL-44; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836;, Federal Specification AA-59544; NEMA WC70 / ICEA S-95-658; NEMA RV4 2012; NFPA 70., National Electrical Code (NEC ). ARRA 2009 Section 1605 Buy American Compliant., IEEE 1202/FT4 Flame Test; ICEA T-29-520 (210,000 Btu/hr) Flame Test.
Approximate Net Weight (lbs/1000 ft): 4-4-4, Standard Packaging (ft): 500’, Conductor Sizes (AWG): 4/0-4/0-2/0, Allowable Ampacities for Direct Burial: 322, Code Name: Sweetbriar, Finished Cable - Outside Diameter (in): 1.420, Neutral Conductor - No of Strands: 12, Neutral Conductor - Outside Diameter (in): 0.536, Neutral Conductor - Size (AWG): 2/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 19, Phase Conductors - Outside Diameter (in): 0.635, Phase Conductors - Size (AWG): 4/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 1/0-1/0-2, Standard Packaging (ft): 500’, Conductor Sizes (AWG): 1/0-1/0-2, Allowable Ampacities for Direct Burial: 219, Code Name: Brenau, Finished Cable - Outside Diameter (in): 1.111, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.388, Neutral Conductor - Size (AWG): 2, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 10, Phase Conductors - Outside Diameter (in): 0.496, Phase Conductors - Size (AWG): 1/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant.
Standard Packaging: 5000' Reel, Approximate Net Weight (lbs/1000 ft): 90, Number of Strands: 7, Allowable Ampacity (Amps) 60°C / 75°C / 90°C: - / 90 / 100, Size (AWG or KCMIL): 2, Approximate Overall Dimensions (in): 0.388, Compact Diameter of Aluminum Conductor (in): 0.268, XLPE Insulation Thickness (in): 0.060 Application:, Construction:, Conductors Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation Cross-linked polyethylene (XLPE) per UL-854. Sunlight-resistant in all colors 6 AWG and larger, Standards:
Color: Black, Outside Diameter: 0.671" (17.05 mm), Number of Strands: 37, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 215, Allowable Ampacities (amps) @ 75°C: 255, Allowable Ampacities (amps) @ 90°C: 290, Approximate Net Weight: 826 lbs/1000 ft (1229 kg/km), Insulation Thickness XLPE: 0.065" (1.64 mm), (KCMIL): 250 A great alternative to eliminate the need for lube. Slick outer surface for easy pulling., SuperSlick Elite XHHW-2/RW90 is available in sizes 8 AWG through 1000 KCMIL. On 250 KCMIL and larger, sequential foot markings located every foot for easy measuring. Rated VW-1., For 1 AWG through 4/0 AWG, sequential foot markings on master reels only unless otherwise specified., 6 AWG and larger rated Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr) flame test and ICEA T-29-520 (210,000 Btu/hr) flame test., Construction:, Conductors:, Stranded, uncoated bare copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8., Insulation:, Cross-linked polyethylene (XLPE) insulation per UL-44., Applications:, Type XHHW-2/RW90 is permitted for 600 volt applications and can be used in wet or dry locations at temperatures not to exceed 90, C., Suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less., Standards:, Underwriters Laboratories Standard UL-44., ASTM Stranding Class B3, B8, B787., Federal Specification A-A-59544. Canadian Standards Association C22.2 No. 38., NEMA WC-70/ICEA S-95-658. NFPA 70: National Electrical Code (NEC)., UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger)., ICEA T-29-520 (210,000 Btu/hr) Flame Test. ARRA 2009; Section 1605 "Buy American" Compliant.
Color: Black, Outside Diameter: 0.564" (15.59 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 165, Allowable Ampacities (amps) @ 75°C: 200, Allowable Ampacities (amps) @ 90°C: 225, Approximate Net Weight: 577 lbs/1000 ft (859 kg/km), Insulation Thickness XLPE: 0.055" (2.03 mm), (AWG): 3/0 A great alternative to eliminate the need for lube. Slick outer surface for easy pulling., SuperSlick Elite XHHW-2/RW90 is available in sizes 8 AWG through 1000 KCMIL. On 250 KCMIL and larger, sequential foot markings located every foot for easy measuring. Rated VW-1., For 1 AWG through 4/0 AWG, sequential foot markings on master reels only unless otherwise specified., 6 AWG and larger rated Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr) flame test and ICEA T-29-520 (210,000 Btu/hr) flame test., Construction:, Conductors:, Stranded, uncoated bare copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8., Insulation:, Cross-linked polyethylene (XLPE) insulation per UL-44., Applications:, Type XHHW-2/RW90 is permitted for 600 volt applications and can be used in wet or dry locations at temperatures not to exceed 90, C., Suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less., Standards:, Underwriters Laboratories Standard UL-44., ASTM Stranding Class B3, B8, B787., Federal Specification A-A-59544. Canadian Standards Association C22.2 No. 38., NEMA WC-70/ICEA S-95-658. NFPA 70: National Electrical Code (NEC)., UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger)., ICEA T-29-520 (210,000 Btu/hr) Flame Test. ARRA 2009; Section 1605 "Buy American" Compliant.
Color: Black, Outside Diameter: 0.438" (12.39 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 110, Allowable Ampacities (amps) @ 75°C: 130, Allowable Ampacities (amps) @ 90°C: 150, Approximate Net Weight: 303 lbs/1000 ft (451 kg/km), Insulation Thickness XLPE: 0.055" (2.03 mm), (AWG): 1 A great alternative to eliminate the need for lube. Slick outer surface for easy pulling., SuperSlick Elite XHHW-2/RW90 is available in sizes 8 AWG through 1000 KCMIL. On 250 KCMIL and larger, sequential foot markings located every foot for easy measuring. Rated VW-1., For 1 AWG through 4/0 AWG, sequential foot markings on master reels only unless otherwise specified., 6 AWG and larger rated Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr) flame test and ICEA T-29-520 (210,000 Btu/hr) flame test., Construction:, Conductors:, Stranded, uncoated bare copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8., Insulation:, Cross-linked polyethylene (XLPE) insulation per UL-44., Applications:, Type XHHW-2/RW90 is permitted for 600 volt applications and can be used in wet or dry locations at temperatures not to exceed 90, C., Suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less., Standards:, Underwriters Laboratories Standard UL-44., ASTM Stranding Class B3, B8, B787., Federal Specification A-A-59544. Canadian Standards Association C22.2 No. 38., NEMA WC-70/ICEA S-95-658. NFPA 70: National Electrical Code (NEC)., UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger)., ICEA T-29-520 (210,000 Btu/hr) Flame Test. ARRA 2009; Section 1605 "Buy American" Compliant.
Approximate Net Weight (lbs/1000 ft): 844, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 250-250-3/0, Allowable Ampacities for Direct Burial: 356, Code Name: Pratt, Finished Cable - Outside Diameter (in): 1.550, Neutral Conductor - No of Strands: 15, Neutral Conductor - Outside Diameter (in): 0.583, Neutral Conductor - Size (AWG): 3/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 22, Phase Conductors - Outside Diameter (in): 0.710, Phase Conductors - Size (AWG): 250, Phase Conductors - XLPE Thickness (in): 0.095 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant.
Approximate Net Weight (lbs/1000 ft): 546, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 100, Allowable Ampacities (amps) @ 75°C: 120, Allowable Ampacities (amps) @ 90°C: 135, Nominal Diameter (in): 1.150, Allowable Ampacities (amps) @ **Dwelling: 125, Ground/Neutral - Sizes (AWG): 2, Ground/Neutral - Style/Ground Neutral: 7, Insulated Phase Conductors - No of Strands: 10, Insulated Phase Conductors - Sizes (AWG): 1/0-1/0-1/0, Product Name (includes Ground): 1/0-1/0-1/0-2 Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 0 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836., Assembly:, Applications:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544., National Electric Code (NEC ) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant.
Color: Black, Outside Diameter: 0.248" (6.30 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 55, Allowable Ampacities (amps) @ 75°C: 65, Allowable Ampacities (amps) @ 90°C: 75, Size (AWG): 6, Approximate Net Weight: 94 lbs/1000 Ft (141 kg/km), Cross Sect Area (mm²): 13.30, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723 THHN 600V.jpg 4 AWG, Stranded, Black THHN Wire, 1000’ Reel
Locke Part #: P1642MFG Part #: 118101401450
Color: Black, Outside Diameter: 0.317" (8.06 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 70, Allowable Ampacities (amps) @ 75°C: 85, Allowable Ampacities (amps) @ 90°C: 95, Size (AWG): 4, Approximate Net Weight: 153 lbs/1000ft (228 kg/km), Cross Sect Area (mm²): 21.20, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Outside Diameter: 0.212" (5.39 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 40, Allowable Ampacities (amps) @ 75°C: 50, Allowable Ampacities (amps) @ 90°C: 55, Size (AWG): 8, Approximate Net Weight: 62 lbs/1000 Ft (94 kg/km), Cross Sect Area (mm²): 8.37, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Blue, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Gray, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Brown, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 2500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
P0723 THHN 600V.jpg 2 AWG, Stranded, Black THHN Wire, 1000’ Reel
Locke Part #: P1746MFG Part #: 118101601450
Color: Black, Outside Diameter: 0.375" (9.53 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 95, Allowable Ampacities (amps) @ 75°C: 115, Allowable Ampacities (amps) @ 90°C: 130, Size (AWG): 2, Approximate Net Weight: 233 lbs/1000ft (348 kg/km), Cross Sect Area (mm²): 33.60, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Outside Diameter: 1.051" (26.70 mm), Number of Strands: 61, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 355, Allowable Ampacities (amps) @ 75°C: 420, Allowable Ampacities (amps) @ 90°C: 475, Approximate Net Weight: 2019 lbs/1000ft (3004 kg/km), Cross Sect Area (mm²): 304.00, Nylon Jacket Thickness: 0.009" (0.229 mm), PVC Insulation Thickness (Conductor): 0.070" (1.778 mm), Size (KCMIL): 600 A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Outside Diameter: 0.777" (19.74 mm), Number of Strands: 37, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 260, Allowable Ampacities (amps) @ 75°C: 310, Allowable Ampacities (amps) @ 90°C: 350, Approximate Net Weight: 1170 lbs/1000ft (1741 kg/km), Cross Sect Area (mm²): 177.00, Nylon Jacket Thickness: 0.008" (0.200 mm), PVC Insulation Thickness (Conductor): 0.060" (1.520 mm), Size (KCMIL): 350 A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Outside Diameter: 0.902" (22.91 mm), Number of Strands: 37, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 320, Allowable Ampacities (amps) @ 75°C: 380, Allowable Ampacities (amps) @ 90°C: 430, Approximate Net Weight: 1650 lbs/1000ft (2455 kg/km), Cross Sect Area (mm²): 253.00, Nylon Jacket Thickness: 0.008" (0.200 mm), PVC Insulation Thickness (Conductor): 0.060" (1.520 mm), Size (KCMIL): 500 A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Red, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: White, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Red, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Blue, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Green, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Orange, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Yellow, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Brown, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Purple, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Gray, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Black, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 2000’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: White, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Red, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Blue, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Green, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Orange, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Yellow, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Brown, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Purple, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
Color: Gray, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 4 AWG, Stranded, Red THWN Wire 1000’ Reel
Locke Part #: P1793MFG Part #: 118101403450
Color: Red, Outside Diameter: 0.317" (8.06 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 70, Allowable Ampacities (amps) @ 75°C: 85, Allowable Ampacities (amps) @ 90°C: 95, Size (AWG): 4, Approximate Net Weight: 153 lbs/1000ft (228 kg/km), Cross Sect Area (mm²): 21.20, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 4 AWG, Stranded, Blue THWN Wire 1000’ Reel
Locke Part #: P1794MFG Part #: 118101404450
Color: Blue, Outside Diameter: 0.317" (8.06 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 70, Allowable Ampacities (amps) @ 75°C: 85, Allowable Ampacities (amps) @ 90°C: 95, Size (AWG): 4, Approximate Net Weight: 153 lbs/1000ft (228 kg/km), Cross Sect Area (mm²): 21.20, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 4 AWG, Stranded, White THWN Wire 1000’ Reel
Locke Part #: P1795MFG Part #: 118101402450
Color: White, Outside Diameter: 0.317" (8.06 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 70, Allowable Ampacities (amps) @ 75°C: 85, Allowable Ampacities (amps) @ 90°C: 95, Size (AWG): 4, Approximate Net Weight: 153 lbs/1000ft (228 kg/km), Cross Sect Area (mm²): 21.20, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 2/0 AWG, Stranded, Red THWN Wire 1000’ Reel
Locke Part #: P1802MFG Part #: 118101903450
Color: Red, Outside Diameter: 0.518" (13.16 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 145, Allowable Ampacities (amps) @ 75°C: 175, Allowable Ampacities (amps) @ 90°C: 195, Size (AWG): 2/0, Approximate Net Weight: 462 lbs/1000ft (687 kg/km), Cross Sect Area (mm²): 67.40, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 2/0 AWG, Stranded, Blue THWN Wire 1000’ Reel
Locke Part #: P1803MFG Part #: 118101904450
Color: Blue, Outside Diameter: 0.518" (13.16 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 145, Allowable Ampacities (amps) @ 75°C: 175, Allowable Ampacities (amps) @ 90°C: 195, Size (AWG): 2/0, Approximate Net Weight: 462 lbs/1000ft (687 kg/km), Cross Sect Area (mm²): 67.40, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: White, Outside Diameter: 0.518" (13.16 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 145, Allowable Ampacities (amps) @ 75°C: 175, Allowable Ampacities (amps) @ 90°C: 195, Size (AWG): 2/0, Approximate Net Weight: 462 lbs/1000ft (687 kg/km), Cross Sect Area (mm²): 67.40, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 3/0 AWG, Stranded, Red THWN Wire 1000’ Reel
Locke Part #: P1807MFG Part #: 118102003450
Color: Red, Outside Diameter: 0.568" (14.43 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 165, Allowable Ampacities (amps) @ 75°C: 200, Allowable Ampacities (amps) @ 90°C: 225, Size (AWG): 3/0, Approximate Net Weight: 572 lbs/1000ft (851 kg/km), Cross Sect Area (mm²): 85.00, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 3/0 AWG, Stranded, Blue THWN Wire 1000’ Reel
Locke Part #: P1808MFG Part #: 118102004450
Color: Blue, Outside Diameter: 0.568" (14.43 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 165, Allowable Ampacities (amps) @ 75°C: 200, Allowable Ampacities (amps) @ 90°C: 225, Size (AWG): 3/0, Approximate Net Weight: 572 lbs/1000ft (851 kg/km), Cross Sect Area (mm²): 85.00, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: White, Outside Diameter: 0.568" (14.43 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 165, Allowable Ampacities (amps) @ 75°C: 200, Allowable Ampacities (amps) @ 90°C: 225, Size (AWG): 3/0, Approximate Net Weight: 572 lbs/1000ft (851 kg/km), Cross Sect Area (mm²): 85.00, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 1/0 AWG, Stranded, Red THWN Wire 1000’ Reel
Locke Part #: P1837MFG Part #: 118101803450
Color: Red, Outside Diameter: 0.474" (12.04 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 125, Allowable Ampacities (amps) @ 75°C: 150, Allowable Ampacities (amps) @ 90°C: 170, Size (AWG): 1/0, Approximate Net Weight: 372 lbs/1000ft (554 kg/km), Cross Sect Area (mm²): 53.50, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 1/0 AWG, Stranded, Blue THWN Wire 1000’ Reel
Locke Part #: P1838MFG Part #: 118101804450
Color: Blue, Outside Diameter: 0.474" (12.04 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 125, Allowable Ampacities (amps) @ 75°C: 150, Allowable Ampacities (amps) @ 90°C: 170, Size (AWG): 1/0, Approximate Net Weight: 372 lbs/1000ft (554 kg/km), Cross Sect Area (mm²): 53.50, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Color: White, Outside Diameter: 0.474" (12.04 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 125, Allowable Ampacities (amps) @ 75°C: 150, Allowable Ampacities (amps) @ 90°C: 170, Size (AWG): 1/0, Approximate Net Weight: 372 lbs/1000ft (554 kg/km), Cross Sect Area (mm²): 53.50, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 3 AWG, Stranded, Red THWN Wire 1000’ Reel
Locke Part #: P2249MFG Part #: 118101503450
Color: Red, Outside Diameter: 0.344" (8.74 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 85, Allowable Ampacities (amps) @ 75°C: 100, Allowable Ampacities (amps) @ 90°C: 110, Size (AWG): 3, Approximate Net Weight: 189 lbs/1000ft (281 kg/km), Cross Sect Area (mm²): 26.70, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 3 AWG, Stranded, Blue THWN Wire 1000’ Reel
Locke Part #: P2250MFG Part #: 118101504450
Color: Blue, Outside Diameter: 0.344" (8.74 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 85, Allowable Ampacities (amps) @ 75°C: 100, Allowable Ampacities (amps) @ 90°C: 110, Size (AWG): 3, Approximate Net Weight: 189 lbs/1000ft (281 kg/km), Cross Sect Area (mm²): 26.70, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 3 AWG, Stranded, White THWN Wire 1000’ Reel
Locke Part #: P2251MFG Part #: 118101502450
Color: White, Outside Diameter: 0.344" (8.74 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 85, Allowable Ampacities (amps) @ 75°C: 100, Allowable Ampacities (amps) @ 90°C: 110, Size (AWG): 3, Approximate Net Weight: 189 lbs/1000ft (281 kg/km), Cross Sect Area (mm²): 26.70, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 2 AWG, Stranded, Red THWN Wire 1000’ Reel
Locke Part #: P2512MFG Part #: 118101603450
Color: Red, Outside Diameter: 0.375" (9.53 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 95, Allowable Ampacities (amps) @ 75°C: 115, Allowable Ampacities (amps) @ 90°C: 130, Size (AWG): 2, Approximate Net Weight: 233 lbs/1000ft (348 kg/km), Cross Sect Area (mm²): 33.60, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 2 AWG, Stranded, Blue THWN Wire 1000’ Reel
Locke Part #: P2513MFG Part #: 118101604450
Color: Blue, Outside Diameter: 0.375" (9.53 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 95, Allowable Ampacities (amps) @ 75°C: 115, Allowable Ampacities (amps) @ 90°C: 130, Size (AWG): 2, Approximate Net Weight: 233 lbs/1000ft (348 kg/km), Cross Sect Area (mm²): 33.60, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 2 AWG, Stranded, White THWN Wire 1000’ Reel
Locke Part #: P2514MFG Part #: 118101602450
Color: White, Outside Diameter: 0.375" (9.53 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 95, Allowable Ampacities (amps) @ 75°C: 115, Allowable Ampacities (amps) @ 90°C: 130, Size (AWG): 2, Approximate Net Weight: 233 lbs/1000ft (348 kg/km), Cross Sect Area (mm²): 33.60, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 1 AWG, Stranded, Red THWN Wire 1000’ Reel
Locke Part #: P2516MFG Part #: 118101703450
Color: Red, Outside Diameter: 0.435" (11.05 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 110, Allowable Ampacities (amps) @ 75°C: 130, Allowable Ampacities (amps) @ 90°C: 150, Size (AWG): 1, Approximate Net Weight: 298 lbs/1000ft (445 kg/km), Cross Sect Area (mm²): 42.40, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 1 AWG, Stranded, Blue THWN Wire 1000’ Reel
Locke Part #: P2517MFG Part #: 118101704450
Color: Blue, Outside Diameter: 0.435" (11.05 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 110, Allowable Ampacities (amps) @ 75°C: 130, Allowable Ampacities (amps) @ 90°C: 150, Size (AWG): 1, Approximate Net Weight: 298 lbs/1000ft (445 kg/km), Cross Sect Area (mm²): 42.40, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
P0723.jpg 1 AWG, Stranded, White THWN Wire 1000’ Reel
Locke Part #: P2518MFG Part #: 118101702450
Color: White, Outside Diameter: 0.435" (11.05 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 110, Allowable Ampacities (amps) @ 75°C: 130, Allowable Ampacities (amps) @ 90°C: 150, Size (AWG): 1, Approximate Net Weight: 298 lbs/1000ft (445 kg/km), Cross Sect Area (mm²): 42.40, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant
Size: 8 AWG, Packaging (ft): 1000’ reels, Approximate Net Weight (lbs/1000 ft) - 3: 282, Approximate Net Weight (lbs/1000 ft) - 4: 351, Number Of Conductors: 4/3, Outer Jacket Thickness PVC (in) - 3: .060, Outer Jacket Thickness PVC (in) - 4: .060, Outside Diameter (in) - 3: .610, Outside Diameter (in) - 4: .655
Size: 8 AWG, Packaging (ft): 1000’ reels, Approximate Net Weight (lbs/1000 ft) - 3: 315, Approximate Net Weight (lbs/1000 ft) - 4: 385, Number Of Conductors: 4/3, Outer Jacket Thickness PVC (in) - 3: 0.060, Outer Jacket Thickness PVC (in) - 4: 0.060, Outside Diameter (in) - 3: 0.610, Outside Diameter (in) - 4: 0.660, Size of Ground Wire (AWG): 10 Green Insulated
Size: 6 AWG, Packaging (ft): 1000’ reels, Approximate Net Weight (lbs/1000 ft) - 3: 452, Approximate Net Weight (lbs/1000 ft) - 4: 558, Number Of Conductors: 4/3, Outer Jacket Thickness PVC (in) - 3: 0.060, Outer Jacket Thickness PVC (in) - 4: 0.060, Outside Diameter (in) - 3: 0.690, Outside Diameter (in) - 4: 0.760, Size of Ground Wire (AWG): 8 Green Insulated
Approximate Net Weight (lbs/1000 ft): 332, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 2-2-2-4, Allowable Ampacities for Direct Burial: 153, Code Name: Dyke, Finished Cable - Outside Diameter (in): 0.937, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.330, Neutral Conductor - Size (AWG): 4, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.388, Phase Conductors - Size (AWG): 2, Phase Conductors - XLPE Thickness (in): 0.060 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant.
Allowable Ampacity (Amps): 16, Approximate Net Weight (lbs/1000 ft): 132, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.385, Size (AWG) and Number of Conductors: 12/4G, Standard Packaging (ft): 1000’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant.