Product Image Not Available24HX8 2T 8KW HORIZ FAN COIL
Locke Part #: L7299MFG Part #: 412408 LO1117 Compare
L7300.jpgHorizontal Fan Coil
Locke Part #: L7300MFG Part #: 412405 LO1117 Compare
W: 37-1/4, D: 21, H: 10, Nominal Clg.: 2.0 Tons, KW (Heat): 5, Shipping lbs.: 63 lbs. Expansion Valve Required For 13 Seer Match-ups. Will Not Work Without Expansion Valve, Primary and secondary drains, Insulated "sandwich-type" condensate pan, Factory installed electric heat (except 0 KW), Easy service access, 24/240V relay/ transformer, Copper tube coils, Piston type metering device
Product Image Not Available942-1 HP CONTROL
Locke Part #: L7301MFG Part #: 942-1 LO1117 Compare
L7300.jpgHorizontal Fan Coil
Locke Part #: L7302MFG Part #: 412410 LO1117 Compare
W: 37-1/4, D: 21, H: 10, Nominal Clg.: 2.0 Tons, KW (Heat): 10, Shipping lbs.: 63 lbs. Expansion Valve Required For 13 Seer Match-ups. Will Not Work Without Expansion Valve, Primary and secondary drains, Insulated "sandwich-type" condensate pan, Factory installed electric heat (except 0 KW), Easy service access, 24/240V relay/ transformer, Copper tube coils, Piston type metering device
413.jpg90 Side Outlet Elbow, Slip x Slip x Slip, 1 Inch
Locke Part #: L7303MFG Part #: 413010 LO1117 Compare
Warranty: Fitting modification voids the warranty., Color: WHITE, Type: Poly Vinyl Chloride (PVC), W: 43-1/4, D: 21, H: 10, Nominal Clg.: 2.5 Tons, KW (Heat): 10, Shipping lbs.: 60 lbs. Expansion Valve Required For 13 Seer Match-ups. Will Not Work Without Expansion Valve, Primary and secondary drains, Insulated "sandwich-type" condensate pan, Factory installed electric heat (except 0 KW), Easy service access, 24/240V relay/ transformer, Copper tube coils, Piston type metering device 25528718213
L7304.jpg27-1/2" x 43" Louvered Access Panel
Locke Part #: L7304MFG Part #: 965 Compare
For FIRST Co. Fan Coil Models: 18HX, 19HX, 24HX, 18HXPO, Frame Dimension: 27-1/2" x 43" Panels are surface mount... They don t have to perfectly match the opening, Attractive backed on white epoxy coating, Filter clips are provided on louvered models to accept 20x20 filter, Hinged panel can be reversed for better clearance, Insulated "sandwich-type" condensate pan, Panels can be painted in the field, Captive screws now on all panels. Screws stay in panel when door is opened
L7304.jpg27-1/2" x 49" Louvered Access Panel
Locke Part #: L7305MFG Part #: 966 Compare
For FIRST Co. Fan Coil Models: 25HX, 30HX, 24HXHPO, 30HXHPO, Frame Dimension: 27-1/2" x 49" Panels are surface mount... They don t have to perfectly match the opening, Attractive backed on white epoxy coating, Filter clips are provided on louvered models to accept 20x20 filter, Hinged panel can be reversed for better clearance, Insulated "sandwich-type" condensate pan, Panels can be painted in the field, Captive screws now on all panels. Screws stay in panel when door is opened
Expansion Valve Required For 13 Seer Match-ups. Will Not Work Without Expansion Valve, Primary and secondary drains, Insulated "sandwich-type" condensate pan, Factory installed electric heat (except 0 KW), Easy service access, 24/240V relay/ transformer, Copper tube coils, Piston type metering device
L7300.jpgBlow Wheel Fits:18HX & 24HX
Locke Part #: L7311MFG Part #: W31S LO1117 Compare
Expansion Valve Required For 13 Seer Match-ups. Will Not Work Without Expansion Valve, Primary and secondary drains, Insulated "sandwich-type" condensate pan, Factory installed electric heat (except 0 KW), Easy service access, 24/240V relay/ transformer, Copper tube coils, Piston type metering device
L7300.jpgR22 Expansion Valve 2-3 ton for HX Air Handlers
Locke Part #: L7312MFG Part #: 9EVR22-2 LO1117 Compare
Expansion Valve Required For 13 Seer Match-ups. Will Not Work Without Expansion Valve, Primary and secondary drains, Insulated "sandwich-type" condensate pan, Factory installed electric heat (except 0 KW), Easy service access, 24/240V relay/ transformer, Copper tube coils, Piston type metering device
L7300.jpg410A Expansion Valve for First Company Air Handlers
Locke Part #: L7313MFG Part #: 9EVR410-1 LO1117 Compare
Expansion Valve Required For 13 Seer Match-ups. Will Not Work Without Expansion Valve, Primary and secondary drains, Insulated "sandwich-type" condensate pan, Factory installed electric heat (except 0 KW), Easy service access, 24/240V relay/ transformer, Copper tube coils, Piston type metering device
L7300.jpgHorizontal Fan Coil
Locke Part #: L7314MFG Part #: 412406 LO1117 Compare
W: 37-1/4, D: 21, H: 10, Nominal Clg.: 2.0 Tons, KW (Heat): 6 Expansion Valve Required For 13 Seer Match-ups. Will Not Work Without Expansion Valve, Primary and secondary drains, Insulated "sandwich-type" condensate pan, Factory installed electric heat (except 0 KW), Easy service access, 24/240V relay/ transformer, Copper tube coils, Piston type metering device
L7300.jpgHorizontal Fan Coil
Locke Part #: L7315MFG Part #: 413008 LO1117 Compare
W: 43-1/4, D: 21, H: 10, Nominal Clg.: 2.5 Tons, KW (Heat): 8v Expansion Valve Required For 13 Seer Match-ups. Will Not Work Without Expansion Valve, Primary and secondary drains, Insulated "sandwich-type" condensate pan, Factory installed electric heat (except 0 KW), Easy service access, 24/240V relay/ transformer, Copper tube coils, Piston type metering device
L7304.jpgSolid Panel
Locke Part #: L7316MFG Part #: 965-1 Compare
Panels are surface mount... They don t have to perfectly match the opening, Attractive backed on white epoxy coating, Filter clips are provided on louvered models to accept 20x20 filter, Hinged panel can be reversed for better clearance, Insulated "sandwich-type" condensate pan, Panels can be painted in the field, Captive screws now on all panels. Screws stay in panel when door is opened