Loading ...

Loading ...

Search in: HONEYWELL INC

DS05C1055.jpg DialSet NPT Pressure Reducing Valve, 3/4" Pipe Size
Locke Part #: E0267MFG Part #: DS06-101-SUT-LF/U
Dimensions: 5-1/4" H x 4-5/16" Long, Valve Type: Pressure Regulating Valve, Ambient Temperature Range: 33° F to 140° F, Calibrated Adjustment Dial: Yes, Dial Calibration: ±4 psi, Differential: 14 psi min (inlet to outlet), Max Inlet Pressure Rating: 400 psi, Operating Temperature Range: 180°F (Max.), Outlet Pressure Adjustment Range: 15-90 psi, Pipe Size: 3/4", Reduced Pressure Range: 5 to 75 psi, Reducing Ratio: 10:1 max., Strainer Screen Size: 0.032", Union Fittings: Single-Union Threaded Dial is calibrated in 10 psi increments to allow quick and accurate adjustment of outlet pressure., Flow capacity and accuracy make the DS05 suitable for potable water service and most irrigation applications., High pressure (400 psi) inlet rating., Non-corroding unitized cartridge contains all working parts and is easily replaceable., Bronze body with stainless steel and engineered thermoplastic internal parts., Balanced single seat for accurate pressure output under varying inlet pressures., Inlet and outlet are internally threaded female NPT, and externally threaded for use with union assemblies., Built-in strainer and thermal bypass., One model can be used in low, standard or high pressure applications., Connection Type:, Female NPT threaded inlet and outlet. Externally threaded for unions, Materials:, Bronze (body), Fabric reinforced diaphragm, Stainless steel and engineered thermoplastics, Approvals:, Canadian Standards Association (B356), ASSE (1003), IAPMO
Color: Arctic White, Dimensions: 4-5/8” x 4-15/16” x 1-1/8”, Application: Up to 3H/2C heat pump or up to 2H/2C conventional, Operating Temperature Range: 32°F to 120°F, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Frequency: 50 Hz; 60 Hz, Display Size: 10 sq in., Electrical Ratings: 18 to 30 VAC or 750 mV, Changeover: Auto or Manual, Dehumidification Setting Range: 40 to 80% RH, Electrical Connections: Screw Terminals, Humidification Setting Range: Cooling: 40 to 80% RH, Heating: 10 to 60% RH, Power Method: Battery or Hardwired, Programmability: 7-Day Multiple Day Programming or Non-Programmable, Setting Temperature Range: Heat: 40°F to 90°F; Cool 50°F to 99°F, Switch Positions (Fan): AUTO-ON-CIRC-FOLLOW SCHEDULE, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT Thermostat works standalone or with the THM5421R1021 Equipment Interface Module or with the TrueZONE Wireless Adapter., Smart Schedule - programs in seconds for any lifestyle., Patented interview based programming and installer setup., RedLINK wireless communication., Selectable for residential and light commercial applications. Meets commercial code and is title 24 compliant., Plain language setup, no manual needed., Alerts and User Interactions Log, Customizable Service Reminders, MicroSD port for copying the Installer Setup, Customizable Reminders, Custom Events and Holidays to multiple thermostats., MicroSD port for adding the dealer's contact information on the screen., 1 assignable output on the TH8321 model to control humidification, dehumidification, ventilation or a stage of heating/cooling., 1 assignable input can be used with a wired outdoor, indoor or discharge sensor., Extend wireless range of the Equipment Interface Module by connecting a THM4000R1000 Wireless Adapter, Dual powered - battery or hardwired (C wire)., Precise temperature control (+/- 1 F) for reliable and consistent temperature., Multiple staging options to provide comfort or energy savings., Stages:, Up to 3 Heat / 2 Cool Heat Pump or Up to 2 Heat / 2 Cool Conventional when used standalone; Up to 4 Heat / 2 Cool Heat Pump or Up to 3 Heat / 2 Cool Conventional when used with the Equipment Interface Module., Terminal Designations:, R, RC, C, W-O/B, W2-AUX/E, Y, Y2, G, A-L/A, K, U1 U1, S1 S1, Used With:, Works standalone or with optional THM5421R1021 Equipment Interface Module and RedLINK accessories, UN 3091 Lithium metal batteries packed in/with equipment
Color: Arctic White, Dimensions: 4-5/8” x 4-15/16” x 1-1/8”, Application: Up to 1H/1C heat pump or up to 1H/1C conventional, Operating Temperature Range: 32°F to 120°F, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Frequency: 50 Hz; 60 Hz, Display Size: 10 sq in., Electrical Ratings: 18 to 30 VAC or 750 mV, Changeover: Auto or Manual, Dehumidification Setting Range: 40 to 80% RH, Electrical Connections: Screw Terminals, Humidification Setting Range: Cooling: 40 to 80% RH, Heating: 10 to 60% RH, Power Method: Battery or Hardwired, Programmability: 7-Day Multiple Day Programming or Non-Programmable, Setting Temperature Range: Heat: 40°F to 90°F; Cool 50°F to 99°F, Switch Positions (Fan): AUTO-ON-CIRC-FOLLOW SCHEDULE, Switch Positions (System): HEAT-OFF-COOL-AUTO Thermostat works standalone or with the THM5421R1021 Equipment Interface Module or with the TrueZONE Wireless Adapter., Smart Schedule - programs in seconds for any lifestyle., Patented interview based programming and installer setup., RedLINK wireless communication., Selectable for residential and light commercial applications. Meets commercial code and is title 24 compliant., Plain language setup, no manual needed., Alerts and User Interactions Log, Customizable Service Reminders, MicroSD port for copying the Installer Setup, Customizable Reminders, Custom Events and Holidays to multiple thermostats., MicroSD port for adding the dealer's contact information on the screen., 1 assignable output on the TH8321 model to control humidification, dehumidification, ventilation or a stage of heating/cooling., 1 assignable input can be used with a wired outdoor, indoor or discharge sensor., Extend wireless range of the Equipment Interface Module by connecting a THM4000R1000 Wireless Adapter, Dual powered - battery or hardwired (C wire)., Precise temperature control (+/- 1 F) for reliable and consistent temperature., Multiple staging options to provide comfort or energy savings., Stages:, Up to 1 Heat / 1 Cool Heat Pump or Up to 1 Heat / 1 Cool Conventional when used standalone; Up to 4 Heat / 2 Cool Heat Pump or Up to 3 Heat / 2 Cool Conventional when used with the Equipment Interface Module., Terminal Designations:, R, RC, C, W-O/B, Y, G, K, S1 S1, Used With:, Works standalone or with optional THM5421R1021 Equipment Interface Module and RedLINK accessories, UN 3091 Lithium metal batteries packed in/with equipment
Color: Front: Black, Side: Black, Dimensions: 3-1/2" x 4-1/2" x 7/8", Application: Up to 4 Heat/2 Cool Heat Pumps; Up to 3 Heat/2 Cool Conventional Systems, Operating Temperature Range: 32°F to 120°F, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Frequency: 50 Hz; 60 Hz, Display Size: 8.06 sq in., Electrical Ratings: 18 to 30 VAC, Changeover: Auto or Manual, Dehumidification Setting Range: 40 to 80% RH, Electrical Connections: Screw Terminals, Humidification Setting Range: Cooling: 40 to 80% RH, Heating: 10 to 60% RH, Power Method: Hardwired, Programmability: 7-Day Multiple Day Programming or Non-Programmable, Setting Temperature Range: Heat: 40°F to 90°F; Cool 50°F to 99°F, Switch Positions (Fan): AUTO-ON-CIRC-FOLLOW SCHEDULE, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT, Humidity Sensor Accuracy: ± 5% RH From 30% to 50% RH at 75°F, Temperature Sensor Accuracy: ± 1.5°F at 70°F Control heating, cooling and IAQ equipment with only 2 wires at the thermostat. Heating, cooling and IAQ equipment wires to the Equipment Interface Module., Smart Schedule - programs in seconds for any lifestyle, Patented interview based programming and installer setup., RedLINK wireless communication., Selectable for residential and light commercial applications. Meets commercial code and is title 24 compliant., Light commercial - commercial language (occupied and unoccupied), schedule holidays and custom events, remote setback, economizer and time of day., Delta T Alerts and Diagnostics informs customers when their system is not performing as expected with instructions to contact the dealer. Provides a sense of security and greater comfort while generating repeat business., All Prestige IAQ kits come standard with a return and discharge air temperature sensor to measure Delta T., Alerts and User Interactions Log, Performance Logs - Keeps a history of heating and cooling performance, Customizable Service Reminders, USB port for transferring Installer Setup, Customizable Reminders, Custom Events and Holidays to multiple thermostats., USB port for adding the dealer's full color business logo on the screen., 3 assignable outputs to control humidification, dehumidification, ventilation and a stage of heating or cooling., Extend wireless range of the Equipment Interface Module by connecting a THM4000R1000 Wireless Adapter., Tri-lingual - English, French and Spanish display options., Precise temperature control (+/- 1 F) for reliable and consistent temperature., Multiple staging options to provide comfort or energy savings., Stages:, Up to 4 Heat/2 Cool Heat Pumps; Up to 3 Heat/2 Cool Conventional Systems, Kit Includes:, THX9421R5021BB Prestige 2-Wire IAQ Thermostat, THM5421R1021 Equipment Interface Module and 2 Duct Sensors, Terminal Designations:, R, RC, RH, C, W-O/B, W2-AUX1, W3-AUX2, Y, Y2, G, A-L/A, U1, U1, U2, U2, U3, U3, S1, S1, S2, S2, S3, S3, S4, S4, A, B, C, D, Used With:, RedLINK accessories, UN 3091 Lithium metal batteries packed in/with equipment
Color: Front: White, Side: White, Dimensions: 3-1/2" x 4-1/2" x 7/8", Application: Up to 4 Heat/2 Cool Heat Pumps; Up to 3 Heat/2 Cool Conventional Systems, Operating Temperature Range: 32°F to 120°F, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Frequency: 50 Hz; 60 Hz, Display Size: 8.06 sq in., Electrical Ratings: 18 to 30 VAC, Changeover: Auto or Manual, Dehumidification Setting Range: 40 to 80% RH, Electrical Connections: Screw Terminals, Humidification Setting Range: Cooling: 40 to 80% RH, Heating: 10 to 60% RH, Power Method: Hardwired, Programmability: 7-Day Multiple Day Programming or Non-Programmable, Setting Temperature Range: Heat: 40°F to 90°F; Cool 50°F to 99°F, Switch Positions (Fan): AUTO-ON-CIRC-FOLLOW SCHEDULE, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT, Humidity Sensor Accuracy: ± 5% RH From 30% to 50% RH at 75°F, Temperature Sensor Accuracy: ± 1.5°F at 70°F Control heating, cooling and IAQ equipment with only 2 wires at the thermostat. Heating, cooling and IAQ equipment wires to the Equipment Interface Module., Smart Schedule - programs in seconds for any lifestyle, Patented interview based programming and installer setup., RedLINK wireless communication., Selectable for residential and light commercial applications. Meets commercial code and is title 24 compliant., Light commercial - commercial language (occupied and unoccupied), schedule holidays and custom events, remote setback, economizer and time of day., Delta T Alerts and Diagnostics informs customers when their system is not performing as expected with instructions to contact the dealer. Provides a sense of security and greater comfort while generating repeat business., All Prestige IAQ kits come standard with a return and discharge air temperature sensor to measure Delta T., Alerts and User Interactions Log, Performance Logs - Keeps a history of heating and cooling performance, Customizable Service Reminders, USB port for transferring Installer Setup, Customizable Reminders, Custom Events and Holidays to multiple thermostats., USB port for adding the dealer's full color business logo on the screen., 3 assignable outputs to control humidification, dehumidification, ventilation and a stage of heating or cooling., Extend wireless range of the Equipment Interface Module by connecting a THM4000R1000 Wireless Adapter., Tri-lingual - English, French and Spanish display options., Precise temperature control (+/- 1 F) for reliable and consistent temperature., Multiple staging options to provide comfort or energy savings., Stages:, Up to 4 Heat/2 Cool Heat Pumps; Up to 3 Heat/2 Cool Conventional Systems, Kit Includes:, THX9421R5021WW Prestige 2-Wire IAQ Thermostat, THM5421R1021 Equipment Interface Module, C7089R1013 Wireless Outdoor Sensor and 2 Duct Sensors, Terminal Designations:, R, RC, RH, C, W-O/B, W2-AUX1, W3-AUX2, Y, Y2, G, A-L/A, U1, U1, U2, U2, U3, U3, S1, S1, S2, S2, S3, S3, S4, S4, A, B, C, D, Used With:, RedLINK accessories, UN 3091 Lithium metal batteries packed in/with equipment
Finish: Zinc plated steel, Anodized aluminum, Ambient Temperature Rating: 5 to 60° C (+40 to 140° F), Electrical Ratings: 24 Vac 60 Hz 0.32 Amp., 8 VA, Electrical Connection: 1/2" conduit, Size (In): 4-1/2 in. high x 2-3/8 in. wide x 3-3/8 in. deep, Motor or Actuator Mounting: Direct connection to damper shaft, Motor: Spring return, Motor Timing: 30 seconds powered/10 seconds spring return, Wires to Motor: 2, Nominal Angular Rotation: 90° (max. 105°), Torque: Min. 423 milli newton meter (60 in. oz), Direction of Shaft Rotation: clockwise, when energized and viewed from the base or shaft end, Mounting Means: direct connection to damper shaft., Mounting Position: Multi-poise. Low voltage, spring-return damper actuator. Adjustable range stops., Equipped with anti-rotation and drive shaft extensions for direct mounting to 7/16 inch diameter coupling style dampers., Direct replacement for M847D1004, The M847D is a two position, 24 Vac spring return actuator designed to operate ARD, EARD and ZD zone dampers.
Color: Premier White, Dimensions: 3-9/16" x 5-13/16" x 1-1/2", Application: Up to 3 Heat/2 Cool Heat Pumps; Up to 2 Heat/2 Cool Conventional Systems, Mounting: Horizontal, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Frequency: 50 Hz; 60 Hz, Differential Temperature: ± 1° F, Display Size: 5.09 sq. in., Electrical Ratings: 20 to 30 VAC, Changeover: Auto/Manual Selectable, Power Method: Hardwired, Programmability: 7-Day Program, Setting Temperature Range: Heat: 40°F to 90°F; Cool 50°F to 99°F, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT, Cool Current: Y = 0.02 A to 1.0 A Running, Y2 = 0.02 A to 1.0 A Running, Heat Current: W2 (AUX/E) = 0.02 A to 0.5 A Running; W = 0.02 A to 1.0 A Running, Sensor Element: Thermistor Monitor and control thermostat settings from anywhere at any time. Simplified programming and operation., Connect using a regular computer, tablet or smartphone., Automatic software updates through Wi-Fi., Selectable to 7-Day or Non-programmable thermostat., Large, clear, backlit display - easy to read in various lighting conditions. Built in instructions, Precise comfort control ( 1 F) - maintains consistent comfort to the highest level of accuracy., Adaptive Intelligent Recovery- ensures programmed temperature is reached by programmed time., Temperature range stops - prevents user from setting the temperature too high or too low., Stages:, Up to 3 Heat / 2 Cool Heat Pump or Up to 2 Heat / 2 Cool Conventional, Terminal Designations:, Rc, R, W (O/B), W2 (AUX/E), Y, Y2, G, C, K, UN 3091 Lithium metal batteries packed in/with equipment
Application: Ventilation System, Temperature Range: -20°F to 160°F (-29°C to 71°C), Electrical Ratings: 24 VAC, Airflow Capacity (cfm): 50 to 160, Current Draw: 0.6 A, Humidity: 5 to 90% RH, Noncondensing, Tradeline Value: Tradeline Designed to help meet local ventilation codes and standards, including ASHRAE 62.2-2010 standard, Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings., Smart Control optimizes air delivery by syncing ventilation calls with heating/cooling, Easy-to-use input dials allow customized ventilation for each installation, Test mode that includes immediate feedback to installer to confirm that air delivery requirements of selected ventilation standard are being met., Economical supply-only ventilation; works with forced air system, Can be used with other equipment, such as an HRV/ ERV, for balanced ventilation., Y8150 Includes:, W8150A Fresh Air Ventilation Control, EARD6 Fresh Air Damper, AT120B Transformer, Mounting hardware for control, Homeowner information label
Dimensions: 20-1/4" x 24-1/4" x 5-7/8", Application: Replacement Filter, Used With: SpaceGard 2200, 2120, 2250, Lennox PMAC20, GeneralAire AC-1, Tradeline Value: Tradeline, Min Efficiency Reporting Value (Media Filters Only): MERV 11, Type of Air Cleaner: Media Air Cleaner PopUP filters store flat and pop into shape for installation, Save space on the truck., Less damage during storage, Save time on assembly., So easy you can sell over-the-counter to homeowners without worry of mistakes., Compact shape makes PopUP easy to ship., No combs, pleat spacers or end caps, Replaces: Space-Gard* model 2120,2200 & 2250 Lennox*model PMAC20 GeneralAire* model AC-1
Dimensions: 16" x 27-1/8" x 5-7/8", Application: Replacement Filter, Used With: SpaceGard 2400, 2140, Lennox PMAC12, Tradeline Value: Tradeline, Min Efficiency Reporting Value (Media Filters Only): MERV 11, Type of Air Cleaner: Media Air Cleaner PopUP filters store flat and pop into shape for installation, Save space on the truck., Less damage during storage, Save time on assembly., So easy you can sell over-the-counter to homeowners without worry of mistakes., Compact shape makes PopUP easy to ship., No combs, pleat spacers or end caps, Replaces: Space-Gard* model 2140,2400 Lennox* model PMAC12
Color: Premier White, Dimensions: 3-13/16" H X 5-3/8" W X 1-1/4" D, Application: 1 Heat/1 Cool Conventional Systems and Heat Pumps with No Auxiliary Heat, Mounting: Horizontal, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Stages: 1 Heat/1 Cool, Frequency: 50/60 Hz, Switch Type: Relay, Display Size: 1.32 sq in., Electrical Ratings: 20 to 30 Vac, Changeover: Manual, Power Method: Dual Powered: Battery or Hardwire, Setting Temperature Range: Heat: 40°F to 90°F; Cool: 50°F to 99°F, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL, Terminal Designation: R, Rc, W, Y, G, O, B, C, Cool Current: 0.02 A to 1.0 A Running, Heat Current: 0.02 A to 1.0 A Running, Sensor Element: Thermistor, Accuracy (°F): ±1°F, Cycles Per Hour (Cooling): 1-6 CPH, Cycles Per Hour (Heating): 1-12 CPH, Supply Voltage: 20 to 30 Vac; 750 mV
Color: Premier White, Dimensions: 3-13/16" H x 5-3/8" W x 1-1/4" D, Application: 2 Heat/1 Cool Heat Pump Systems, Mounting: Horizontal, Operating Humidity Range: 5% to 90% RH, Non-Condensing, Stages: 2 Heat/1 Cool Heat Pump, Frequency: 50 Hz/60 Hz, Switch Type: Relay, Display Size: 1.32 Sq. In., Electrical Ratings: 20 to 30 Vac, Changeover: Manual, Power Method: Dual Powered Battery or Hardwire, Setting Temperature Range: Heat: 40°F to 90°F ; Cool: 50°F to 99°F, Switch Positions (Fan): AUTO-ON, Switch Position (System): HEAT-OFF-COOL-EM.HEAT, Terminal Designation: R, Y, AUX, E, G, O, B, L, C, Sensor Element: Thermistor, Accuracy (°F): ±1°F, Cycles Per Hour (Cooling): 1-6 CPH, Cycles Per Hour (Heating): 1-12 CPH, Accuracy (°C): ±0.5°C, Electrical Rating Cooling Current: 0.02 A to 1.0 A Running, Electrical Rating Heating Current: 0.02 A to 1.0 A Running Backlit digital display - both current and set temperatures are easy to read in various lighting conditions., Shows both current and set temperatures at the same time, Non-programmable digital thermostat., Precise comfort control [ 1 F ( 0.5 C)] - maintains consistent comfort to the highest level of accuracy., Basic operation - easy-to-use slide switches allow you to select the heat or cool mode, and operate the fan.
Voltage: 24V, Application: Zoning, Includes: HZ322 Zone Control Panel, AT140 Transformer, C7735A Discharge Air Temperature Sensor, Stages: 2 Heat/2 Cool, Compatible with Sensor: Discharge Air Temperature Sensor, Number of Zones: 3 Intuitive Installer setup. Easy-to-follow, digital display uses real language to guide installer through four easy steps. Standard Checkout Procedure, Smaller Footprint, Variable-Speed Fan Control, Discharge Air Temperature Staging, Specifications:, LEDs, Auto Changeover, Heat Pump Compatible, Resettable Fuse, Individual Zone Fan Control, Emergency Heat Switch
Voltage: 24V, Application: Zoning, Includes: HZ432 Zone Control Panel, AT140 Transformer, C7735A Discharge Air Temperature Sensor, Stages: 3 Heat/2 Cool, Compatible with Sensor: Discharge Air Temperature Sensor, Number of Zones: 4 Expandable TrueZONE HZ432 Panel for conventional, heat pump or dual fuel applications expandable up to 32 zones (3H/2C), Advanced Dual-Fuel Operation, Intuitive Installer setup. Easy-to-follow, digital display uses real language to guide installer through four easy steps, Standard Checkout Procedure, Robust Push Terminals, Common-Sense LEDs, Variable-Speed Fan Control, Discharge Air Temperature Staging, Clean, Professional Installation, RedLINK enabled for up to 4 wireless zones when used with THM4000R1000 Wireless Adapter., Specifications:, LEDs, Auto Changeover, Heat Pump Compatible, Resettable Fuse, Individual Zone Fan Control, Emergency Heat Switch
Size: 20" x 12", Voltage: 24 Vac, Application: Parallel Blade Damper, Shape: Rectangular, Used With: Zoning Systems, Frequency: 60 Hz, Electrical Connections: 4" Leadwire, Motor: Power Closed, Spring Open, Motor Timing: 30 Seconds Power Open/10 Seconds Spring Return, Wires to Motor: 2, Motor Electrical Rating Current: 0.32 A, Motor Finish: Zinc-Plated Steel, Anodized Aluminum, Motor Mount: Side, Motor Mounting Means: Direct Connection to Damper Shaft, Motor Mounting Position: Multi-Poise, Motor Nominal Angular Rotation: 90°, Other Motor Information: Range Stops Kevlar gearing reduces wear, more than doubling damper life, Simple, easy-to-wire, two-wire installation., Reliable spring-return motor, Adjustable range stops., Mechanical visual position indicator for damper status., Solid construction using extruded aluminum frame and blades, Fail-safe, normally open operation., Parallel blade design for low leakage performance., Reliable, strong, 24-volt spring-return motor., Compatible with conventional and networked zoning., Damper can be installed in any orientation (mounting side can be on either the bottom or the side of the duct).
Size: 6" diameter, Voltage: 24V, Application: Zone Damper, Shape: Round, Motor or Actuator Mounting: Side or Top, Motor: Power Closed, Spring Open, Reversible, Motor Timing: 30 seconds power open/10 seconds spring return, Wires to Motor: 2
Size: 8" diameter, Voltage: 24V, Application: Zone Damper, Shape: Round, Motor or Actuator Mounting: Side or Top, Motor: Power Closed, Spring Open, Reversible, Motor Timing: 30 seconds power open/10 seconds spring return, Wires to Motor: 2, Other Motor Information: Range stops, Damper Type: Single-blade, round
Size: 10" diameter, Voltage: 24V, Application: Zone Damper, Shape: Round, Motor or Actuator Mounting: Side or Top, Motor: Power Closed, Spring Open, Reversible, Motor Timing: 30 seconds power open/10 seconds spring return, Wires to Motor: 2, Other Motor Information: Range stops, Damper Type: Single-blade, round
Size: 12" diameter, Voltage: 24V, Application: Zone Damper, Shape: Round, Motor or Actuator Mounting: Side or Top, Motor: Power Closed, Spring Open, Reversible, Motor Timing: 30 seconds power open/10 seconds spring return, Wires to Motor: 2, Other Motor Information: Range stops, Damper Type: Single-blade, round
Size: 14" diameter, Voltage: 24V, Application: Zone Damper, Shape: Round, Motor or Actuator Mounting: Side or Top, Motor: Power Closed, Spring Open, Reversible, Motor Timing: 30 seconds power open/10 seconds spring return, Wires to Motor: 2, Other Motor Information: Range stops, Damper Type: Single-blade, round
Size: 16" diameter, Voltage: 24V, Application: Zone Damper, Shape: Round, Motor or Actuator Mounting: Side or Top, Motor: Power Closed, Spring Open, Reversible, Motor Timing: 30 seconds power open/10 seconds spring return, Wires to Motor: 2, Other Motor Information: Range stops, Damper Type: Single-blade, round
ZD16x10.jpg 16" x 10" Parallel Blade Damper, 24V
Locke Part #: L3649MFG Part #: ZD16x10/U
Size: 16" x 10", Voltage: 24 V, Application: Parallel Blade Damper, Shape: Rectangular, Motor or Actuator Mounting: Side, Motor: Power Closed, Spring Open, Motor Timing: 30 Seconds Power Open/10 Seconds Spring Return, Wires to Motor: 2, Motor Electrical Rating Current: 0.32 A, Motor Finish: Zinc-Plated Steel, Anodized Aluminum, Motor Mount: bottom or the side of the duct, Motor Mounting Means: Direct Connection To Damper Shaft, Motor Mounting Position: Multi-poise, Motor Nominal Angular Rotation: 90°, Blade Action: Parallel, Motor Ambient Temperature Rating: 40° to 140°F, Motor Electrical Connection: 4" Leadwire, Motor Shaft Rotation Direction: Clockwise, Motor Torque: Min. 71 in.-oz. Mechanical visual position indicator for damper status., Solid construction using extruded aluminum frame and blades., Parallel blade design for low leakage performance., Simple, easy-to-wire, two-wire installation., Reliable, strong, 24-volt spring-return motor., Fail-safe, normally open operation., Damper can be installed in any orientation (mounting side can be on either the bottom or the side of the duct)., Easy slip-in design, Used With:, Honeywell zoning systems
Size: 20" x 10", Voltage: 24 Vac, Application: Parallel Blade Damper, Shape: Rectangular, Used With: Zoning Systems, Frequency: 60 Hz, Electrical Connections: 4" Leadwire, Motor: Power Closed, Spring Open, Motor Timing: 30 Seconds Power Open/10 Seconds Spring Return, Wires to Motor: 2, Motor Electrical Rating Current: 0.32 A, Motor Finish: Zinc-Plated Steel, Anodized Aluminum, Motor Mount: Side, Motor Mounting Means: Direct Connection to Damper Shaft, Motor Mounting Position: Multi-Poise, Motor Nominal Angular Rotation: 90°, Other Motor Information: Range Stops Kevlar gearing reduces wear, more than doubling damper life, Simple, easy-to-wire, two-wire installation., Reliable spring-return motor, Adjustable range stops., Mechanical visual position indicator for damper status., Solid construction using extruded aluminum frame and blades, Fail-safe, normally open operation., Parallel blade design for low leakage performance., Reliable, strong, 24-volt spring-return motor., Compatible with conventional and networked zoning., Damper can be installed in any orientation (mounting side can be on either the bottom or the side of the duct).
Size: 16", Application: Static Pressure Regulating Damper, Shape: Round, Used With: Honeywell zoning systems, Motor: Weighted damper arm Air pressure in duct system increases as zone dampers close, pushing the SPRD open automatically., Arm and weight both adjustable to control amount of air bypassed, Recommended for low pressure systems with less than 0.5 in. wc., For larger systems and tighter pressure control, use MARD damper and static pressure controller (SPC)., Counter-balanced weighted arm to control bypass air for zoned systems, Additional weights available
Wireless Adapter.jpg Wireless Adapter, Gray
Locke Part #: L3655MFG Part #: THM4000R1000/U
Color: Gray, Dimensions: 5-9/16" H x 4-3/8" W x 1-1/4" D, Mounting: Mount Wireless Adapter on Wall Near HVAC Equipment or on the Duct, Operating Humidity Range: 5% to 95% RH, Non-Condensing, Terminal Designation: A, B, C, D, Operating Ambient Temperature Range: -40°F to 165°F (-40°C to 73.9°C) Wireless Adapter easily add RedLINK enabled thermostats to a TrueZONE system without running new wires. Powered by RedLINK reliability., No interference with other wireless devices in the home., Communicates with Wireless Outdoor Sensor to automatically control humidity to proper levels., One adapter per zone control panel, HZ322 or HZ432 TrueZONE panel Requirements
Dimensions: 2-1/4" x 3/8" with 60" leadwires, Application: Outdoor Sensor for VisionPRO and VisionPRO IAQ Thermostats, Mounting: Mounting Clip Provided and Screws Provided, Ambient Temperature Range: -40°F to +120°F, Operating Humidity Range: 5 to 95% RH, Non-Condensing Remote outdoor temperature sensor, when installed, the current outdoor temperature is displayed. Also can be used to manage dual fuel and lock-out expensive auxiliary heat in heat pump applications., Mounting clip allows easy sensor positioning on siding or soffit., Includes 60 in. leadwires., Maximum wire run of 200 feet.
Color: Premier White, Dimensions: 1-1/2" W x 2-1/4" H x 3/4" D, Application: Remote Indoor Temperature Sensor for VisionPRO and VisionPRO IAQ Thermostat, Mounting: Mounts directly on the wall using mounting screws and anchors provided, Ambient Temperature Range: 45°F to 88°F, Used With: VisionPRO and VisionPRO IAQ Series Thermostats, Operating Humidity Range: 5 to 95% RH, Non-Condensing, Display Range: 0°C to 99°F, Tradeline Value: Tradeline, Sensor Accuracy: +/-1.5°F at 70°F (+/-.84 at 21°C)
Color: Front: White, Side: White, Dimensions: 3-1/2" x 4-1/2" x 7/8", Application: Up to 4 Heat/2 Cool Heat Pumps; Up to 3 Heat/2 Cool Conventional Systems, Operating Temperature Range: 32°F to 120°F, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Frequency: 50 Hz; 60 Hz, Display Size: 8.06 sq in., Electrical Ratings: 18 to 30 VAC, Changeover: Auto or Manual, Dehumidification Setting Range: 40 to 80% RH, Electrical Connections: Screw Terminals, Humidification Setting Range: Cooling: 40 to 80% RH, Heating: 10 to 60% RH, Power Method: Hardwired, Programmability: 7-Day Multiple Day Programming or Non-Programmable, Setting Temperature Range: Heat: 40°F to 90°F; Cool 50°F to 99°F, Switch Positions (Fan): AUTO-ON-CIRC-FOLLOW SCHEDULE, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT, Humidity Sensor Accuracy: ± 5% RH From 30% to 50% RH at 75°F, Temperature Sensor Accuracy: ± 1.5°F at 70°F Control heating, cooling and IAQ equipment with only 2 wires at the thermostat. Heating, cooling and IAQ equipment wires to the Equipment Interface Module., Smart Schedule - programs in seconds for any lifestyle, Patented interview based programming and installer setup., RedLINK wireless communication., Selectable for residential and light commercial applications. Meets commercial code and is title 24 compliant., Light commercial - commercial language (occupied and unoccupied), schedule holidays and custom events, remote setback, economizer and time of day., Delta T Alerts and Diagnostics informs customers when their system is not performing as expected with instructions to contact the dealer. Provides a sense of security and greater comfort while generating repeat business., All Prestige IAQ kits come standard with a return and discharge air temperature sensor to measure Delta T., Alerts and User Interactions Log, Performance Logs - Keeps a history of heating and cooling performance, Customizable Service Reminders, USB port for transferring Installer Setup, Customizable Reminders, Custom Events and Holidays to multiple thermostats., USB port for adding the dealer's full color business logo on the screen., 3 assignable outputs to control humidification, dehumidification, ventilation and a stage of heating or cooling., Extend wireless range of the Equipment Interface Module by connecting a THM4000R1000 Wireless Adapter., Tri-lingual - English, French and Spanish display options., Precise temperature control (+/- 1 F) for reliable and consistent temperature., Multiple staging options to provide comfort or energy savings., Application:, Up to 4 Heat/2 Cool Heat Pumps; Up to 3 Heat/2 Cool Conventional Systems, Stages:, Up to 4 Heat/2 Cool Heat Pumps; Up to 3 Heat/2 Cool Conventional Systems, Kit Includes:, THX9421R5021WW Prestige 2-Wire IAQ Thermostat, THM5421R1021 Equipment Interface Module and 2 Duct Sensors, Terminal Designations:, R, RC, RH, C, W-O/B, W2-AUX1, W3-AUX2, Y, Y2, G, A-L/A, U1, U1, U2, U2, U3, U3, S1, S1, S2, S2, S3, S3, S4, S4, A, B, C, D, Used With:, RedLINK accessories, UN 3091 Lithium metal batteries packed in/with equipment
Color: Premier White, Dimensions: 3-11/16" diameter x 1-3/4" D, Application: 1 Heat/1 Cool Conventional Systems and Heat Pumps with No Auxiliary Heat, Mounting: Round, Operating Humidity Range: 5 to 90% RH (Non-Condensing), Stages: 1 Heat/1 Cool, Frequency: 50/60 Hz, Switch Type: Relay, Electrical Ratings: 20 to 30 Vac, Changeover: Manual, Power Method: Battery assisted power stealing, Setting Temperature Range: 40°F to 90°F, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL, Terminal Designation: R, Rc, W, Y, G, O, B, Cool Current: 0.02A to 1.0A Running, Heat Current: 0.02A to 1.0A Running, Sensor Element: Thermistor, Accuracy (°F): ± 2°F, Supply Voltage: 20 to 30 Vac, Cycles per Hour: Adjustable 1, 3, 5, 9 The Round thermostats provide electronic control of 24Vac heating and cooling systems with the classic twist to set dial.
Color: Premier White, Dimensions: 4-11/16" x 2-7/8" x 1-1/8", Application: 1 Heat/1 Cool Conventional Systems and Heat Pumps with No Auxiliary Heat, Mounting: Vertical, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Frequency: 50 Hz; 60 Hz, Display Size: 1.32 sq in., Electrical Ratings: 20 to 30 VAC or 750 mV, Changeover: Manual, Power Method: Dual Powered: Battery or Hardwire, Setting Temperature Range: Heat: 40°F to 90°F; Cool 50°F to 99°F, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL, Cool Current: 0.02 A to 1.0 A Running, Heat Current: 0.02 A to 1.0 A Running, Cycles per Hour: Heating 2 - 6 CPH; Cooling 2 -6 CPH Backlit display is easy to read, Displays ambient (measured) temperature at all times, One-touch access to setpoint temperature, Built-in compressor protection
Color: Premier White, Dimensions: 4-11/16" x 2-7/8" x 1-1/8", Application: 2 Heat/1 Cool Heat Pump Systems, Mounting: Vertical, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Frequency: 50 Hz; 60 Hz, Display Size: 1.32 sq in., Electrical Ratings: 20 to 30 VAC, Changeover: Manual, Power Method: Dual Powered: Battery or Hardwire, Setting Temperature Range: Heat: 40°F to 90°F; Cool 50°F to 99°F, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL-EM. HT, Cool Current: 0.02 A to 1.0 A Running, Heat Current: 0.02 A to 1.0 A Running, Cycles per Hour: Heating 2 - 6 CPH; Cooling 2 -6 CPH Backlit display is easy to read, Displays ambient (measured) temperature at all times, One-touch access to setpoint temperature, Built-in compressor protection
Color: Premier White, Dimensions: 3-13/16" H X 5-3/8" W X 1-1/4" D, Application: 1 Heat/1 Cool or Heat Pump without Auxiliary Heat, Mounting: Horizontal, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Stages: 1 Heat/1 Cool, Frequency: 50/60 Hz, Differential Temperature: ± 1°F, Display Size: 1.73 sq in., Electrical Ratings: 20 to 30 Vac, Changeover: Manual, Power Method: Dual Powered: Battery or Hardwire, Programmability: 5-2 Day Program, Setting Temperature Range: Heat: 40°F to 90°F; Cool: 50°F to 99°F, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL, Terminal Designation: R, Rc, W, Y, G, O, B, C, Cool Current: 0.02 A to 1.0 A Running, Heat Current: 0.02 A to 1.0 A Running, Sensor Element: Thermistor
Color: Premier White, Dimensions: 3-13/16" H x 5-3/8" W x 1-1/4" D, Application: Heat Pump Systems, Mounting: Horizontal, Operating Humidity Range: 5 to 95% RH, Non-Condensing., Stages: 2 Heat/1 Cool Heat Pump, Frequency: 50 Hz/60 Hz, Differential Temperature: ±1°F, Display Size: 1.73 Sq. In., Electrical Ratings: 20 to 30 Vac or 750 mV, Changeover: Manual, Power Method: Dual Powered Battery or Hardwire, Programmability: 5-2 Day Program, Setting Temperature Range: Heat: 40°F to 90°F ; Cool: 50°F to 99°F, Switch Positions (Fan): Auto-On, Switch Position (System): Heat-off-cool-Em.HT, Terminal Designation: R,Y,AUX,E,G,O,B,L,C, Sensor Element: Thermistor, Electrical Rating Cooling Current: 0.02 A to 1.0 A Running, Electrical Rating Heating Current: 0.02 A to 1.0 A Running
Color: Premier White, Dimensions: 3-9/16" H X 5-13/16" W X 1-1/2" D, Application: Up to 3 Heat/2 Cool Heat Pumps; Up to 2 Heat/2 Cool Conventional Systems, Mounting: Horizontal, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Stages: Up to 3 Heat/ 2 Cool, Frequency: 50/60 Hz, Switch Type: Relay, Display Size: Large display size 5.09 sq. in., Electrical Ratings: 20 to 30 Vac, Changeover: Auto/Manual Selectable, Power Method: Dual Powered: Battery or Hardwire, Setting Temperature Range: Heat: 40°F to 90°F; Cool: 50°F to 99°F, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT, Terminal Designation: Rc, R, W (O/B), W2 (AUX/E), Y, Y2, G, L, C, Cool Current: Y = 0.02 A to 1.0 A Running; Y2 = 0.02 A to 1.0 A Running, Heat Current: W = 0.02 A to 1.0 A Running; W2 (AUX/E) = 0.02 A to 0.5 A Running, Sensor Element: Thermistor, Accuracy (°F): ±1°F, Cycles Per Hour (Cooling): 1-6 CPH, Cycles Per Hour (Heating): 1-12 CPH, Supply Voltage: 20 to 30 Vac, Fan Current: 0.02 A to 0.5 A Running Non-programmable digital thermostat., Large, clear, backlit display - easy to read in various lighting conditions., Display size options - available in large screen or standard., Precise comfort control (+/- 1 F) - maintains consistent comfort to the highest level of accuracy., Easy change battery door - flip out door allows for easy battery replacement without removing or disassembling the thermostat., Dual-powered (battery and/or hardwire).
Color: Premier White, Dimensions: 3-9/16" H X 5-13/16" W X 1-1/2" D, Application: Heat/Cool or Heat Pump with Auxiliary Heat, Mounting: Horizontal, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Stages: Up to 3 Heat / 2 Cool Heat Pump or Up to 2 Heat / 2 Cool Conventional, Frequency: 50/60 Hz, Display Size: Large display size 5.09 sq. in., Electrical Ratings: 20 to 30 Vac, Changeover: Auto/Manual Selectable, Power Method: Battery or Hardwired, Programmability: 5-1-1 Day Program or 5-2 Day Program, Setting Temperature Range: Heat: 40°F to 90°F; Cool: 50°F to 99°F, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT, Terminal Designation: Rc, R, W (O/B), W2 (AUX/E), Y, Y2, G, L, C, Cool Current: Y = 0.02 A to 1.0 A Running, Y2 = 0.02 A to 1.0 A Running, Heat Current: W2 (AUX/E) = 0.02 A to 0.5 A Running; W = 0.02 A to 1.0 A Running, Supply Voltage: 20 to 30 Vac, Fan Current: 0.02 A to 0.5 A Running
Color: Premier White, Dimensions: 3 7/16" x 4 1/2" x 1 5/16", Application: Up to 1 Heat/1 Cool Conventional Systems And Heat Pumps With No Auxiliary Heat, Mounting: Horizontal, Operating Humidity Range: 5 to 90% RH, Stages: Up to1 Heat/1 Cool, Frequency: 50 Hz/60 Hz, Switch Type: Relay, Electrical Ratings: 20 to 30 Vac, Changeover: Auto/Manual, Power Method: Battery or Hardwire, Setting Temperature Range: Heat: 40°F to 90°F; Cool: 50°F to 99°F, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL-AUTO, Cool Current: 1.0 A Running, Heat Current: 1.0 A Running, Sensor Element: Thermistor, Accuracy (°F): ±1° F, Cycles Per Hour (Cooling): 1-6 CPH, Cycles Per Hour (Heating): 1-12 CPH, Fan Current: 0.5 A Running Non-programmable digital thermostat., Large, clear, backlit display - easy to read in various lighting conditions., Display size options - available in large screen or standard., Precise comfort control (+/- 1 F) - maintains consistent comfort to the highest level of accuracy., Easy change battery door - flip out door allows for easy battery replacement without removing or disassembling the thermostat., Dual-powered (battery and/or hardwire).
Color: Premier White, Dimensions: 3-9/16" H X 5-13/16" W X 1-1/2" D, Application: Heat/Cool or Heat Pump without Auxiliary Heat, Mounting: Horizontal, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Stages: Up to 1 Heat/1 Cool, Frequency: 50/60 Hz, Differential Temperature: ± 1°F, Display Size: Standard display size 3.75 sq. in., Electrical Ratings: 20 to 30 Vac, Changeover: Auto/Manual Selectable, Power Method: Battery or Hardwired, Programmability: 5-1-1 Day Program or 5-2 Day Program, Setting Temperature Range: Heat: 40°F to 90°F; Cool: 50°F to 99°F, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL-AUTO, Terminal Designation: Rc, R, W (O/B), Y, G, C, Cool Current: 0.02 A to 1.0 A Running, Heat Current: 0.02 A to 1.0 A Running, Sensor Element: Thermistor, Supply Voltage: 20 to 30 Vac, Fan Current: 0.02 A to 0.5 A Running
Voltage: Equipment Interface Module--18 to 30 Vac, Application: Gas, Oil, Electric, Heat Pump, Forced Warm Air, Hot Water, Steam or Gravity, Stages: Up to 3 Heat / 2 Cool Heat Pump or Up to 2 Heat / 2 Cool Conventional, Frequency: 50/60 Hz, Changeover: Auto/Manual Selectable, Power Method: Battery (Thermostat), Programmability: 5-1-1 Day Program or 5-2 Day Program, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT, Terminal Designation: C, R, Rc, Rh, W-O/B, W2-Aux/E, Y, Y2, G, L, RAS, Electrical Rating Cooling Current: 1.0 A running, Electrical Rating Heating Current: 1.0 A running, Electrical Rating Fan Current: 0.6 A running Wireless Focuspro Thermostat: Same great features of the FocusPRO thermostat - now wireless. Installs in minutes. Displays outdoor temperature and humidity. 1 year battery life. 2 month low battery warning. Dual Fuel enabled., Equipment Interface Module (EIM): All HVAC equipment is wired to the module. Module receives communication from the wireless devices., Return Air Sensor: Works with the Equipment Interface Module to maintain safe indoor temperatures if power is lost at the wireless thermostat. Maintains 62 F for heating and 82 F for cooling., Redlink Wireless Technology: Powered by RedLINK reliability. No interference with other wireless devices in the home.
Voltage: Equipment Interface Module--18 to 30 Vac, Application: Gas, Oil, Electric, Heat Pump, Forced Warm Air, Hot Water, Steam or Gravity, Stages: Up to 3 Heat / 2 Cool Heat Pump or Up to 2 Heat / 2 Cool Conventional, Frequency: 50/60 Hz, Changeover: Auto/Manual Selectable, Power Method: Thermostat--Battery, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT, Terminal Designation: C, R, Rc, Rh, W-O/B, W2-Aux/E, Y, Y2, G, L, RAS, Electrical Rating Cooling Current: 1.0 A running, Electrical Rating Heating Current: 1.0 A running, Electrical Rating Fan Current: 0.6 A running Wireless Focuspro Thermostat: Same great features of the FocusPRO thermostat - now wireless. Installs in minutes. Displays outdoor temperature and humidity. 1 year battery life. 2 month low battery warning. Dual Fuel enabled., Equipment Interface Module (EIM): All HVAC equipment is wired to the module. Module receives communication from the wireless devices., Return Air Sensor: Works with the Equipment Interface Module to maintain safe indoor temperatures if power is lost at the wireless thermostat. Maintains 62 F for heating and 82 F for cooling., Redlink Wireless Technology: Powered by RedLINK reliability. No interference with other wireless devices in the home.
Application: Heat Pump Systems, Forced Warm Air, Changeover: Auto/Manual Selectable, Power Method: Battery (Thermostat), Programmability: 5-1-1 Day Program or 5-2 Day Program, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT WIRELESS ADAPTER: Allows for wireless zoning used with HZ432 or HZ322 TrueZONE panels (sold separately). Adapter receives communication from the wireless devices., WIRELESS FOCUSPRO THERMOSTAT: Installs in minutes. Displays outdoor temperature and humidity (outdoor sensor sold separately). 1 year battery life. 2 month low battery warning., REDLINK WIRELESS TECHNOLOGY: Powered by RedLINK reliability. No interference with other wireless devices in the home., Includes:, TH6320R1004 Wireless FocusPRO 5-1-1 Programmable Thermostat , THM4000R1000 Wireless Adapter
Application: Heat Pump Systems, Forced Warm Air, Changeover: Auto/Manual, Power Method: Thermostat-Battery, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT WIRELESS ADAPTER: Allows for wireless zoning when used with HZ432 or HZ322 TrueZONE panels (sold separately). Adapter receives communication from the wireless devices., WIRELESS FOCUSPRO THERMOSTAT: Same great features of the FocusPRO thermostat - now wireless. Installs in minutes. Displays outdoor temperature and humidity (outdoor sensor sold separately). 1 year battery life. 2 month low battery warning., REDLINK WIRELESS TECHNOLOGY: Powered by RedLINK reliability. No interference with other wireless devices in the home., Includes TH5320R1002 Wireless FocusPRO Non-Programmable Thermostat, THM4000R1000 Wireless Adapter.
Dimensions: 6-1/4" H x 3-1/8" W x 1-5/8" D, Application: Zoned and Non-Zoned, Operating Humidity Range: 5% to 95% RH, Non-Condensing, Differential Temperature: ± 1°F, Changeover: Auto or Manual, Power Method: Battery, Sensor Element: Thermistor, Operating Ambient Temperature Range: 32°F to 120°F (0°C to 48.9°C) Use the Personal Comfort Station anywhere in the home to experience a new level of comfort and convenience. Works in both zoned and non-zoned applications., Powered by RedLINK reliability, No interference with other wireless devices in the home, Works with compatible RedLINK enabled thermostats and accessories, Installs in minutes, Touchscreen interface with backlit display, Can display outdoor temperature and humidity, Built-in pager with an audible noise helps locate the device in the home, Screen-lock feature helps prevent accidental changes, 1 year battery life, 2 month low battery warning In Non-Zoned Applications:, Bring it with you anywhere in the home to sense and control temperature from the room that you are in. In Zoned Applications:, View and adjust all RedLINK enabled thermostats from a single control., Controls up to 16 thermostats
Dimensions: 2-1/4" x 3/8" with 60" Leadwires, Used With: TH8000 and TH7000 Thermostat, Operating Humidity Range: 5 to 95% RH, Non-Condensing, Display Range: -40 to 127°F (-40 to 53°C), Operating Ambient Temperature Range: -40°F to 120°F (-40°C to 49°C), Sensor Accuracy: +/-1.5°F at 70°F (+/-.84 at 21°C), Element Insertion Length: 4233
Color: Premier White, Dimensions: 3-9/16" H x 5-13/16" W x 1-1/2" D, Application: Gas, Oil, Electric, Heat Pump, Forced Warm Air, Hot Water, Steam or Gravity, Mounting: Horizontal, Operating Humidity Range: 5% to 90% RH, Non-Condensing, Stages: Up to 3 Heat / 2 Cool Heat Pump or Up to 2 Heat / 2 Cool Conventional, Differential Temperature: ±1°F (±0.5°C), Power Method: Battery, Programmability: 5-1-1 Day Program or 5-2 Day Program, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT, Operating Ambient Temperature Range: 32°F to 120°F (0°C to 48.9°C) Easily add a zone to a TrueZONE system without running new wires. Choose from programmable or non-programmable., Powered by RedLINK reliability, No interference with other wireless devices in the home, Works with compatible RedLINK enabled devices, Same great features of the FocusPRO thermostat now wireless, Installs in minutes, Can display outdoor temperature and humidity, 1 year battery life, 2 month low battery warning, Dual Fuel enabled - requires THM5320R1000 Equipment Interface Module and C7089R1013 Wireless Outdoor Sensor (sold separately)., Parts Needed for Operation (not included) TrueZONE, System:, HZ432 or HZ322 TrueZONE panel; THM4000R1000 Wireless Adapter
Color: Premier White, Dimensions: 4-11/16" x 2-7/8" x 1-1/8", Application: Heat Only, Mounting: Vertical, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Frequency: 50 Hz; 60 Hz, Display Size: 1.32 sq in., Electrical Ratings: 20 to 30 VAC or 750 mV, Changeover: Manual, Power Method: Dual Powered: Battery or Hardwire, Setting Temperature Range: Selectable Heat: 40°F to 90°F or 35°F to 90°F, Switch Positions (System): HEAT-OFF, Heat Current: 0.02 A to 1.0 A Running, Cycles per Hour: Heating 2 - 6 CPH Backlit display is easy to read, Displays ambient (measured) temperature at all times, One-touch access to setpoint temperature, Built-in compressor protection, Stages:, 1 Heat, Terminal Designations:, R, C, W
RedLINK Internet Gateway.jpg 20 to 30 Vac, RedLINK Internet Gateway
Locke Part #: L3679MFG Part #: THM6000R1002/U
Color: Black, Voltage: 18 to 30 Vac, Dimensions: 6" long X 5" tall X 2-1/2" W, 3-15/16" H, 6-7/8" W, 1-1/2" D, Application: Up to 4 Heat/2 Cool Heat Pumps, Internet control of RedLINK thermostats, Includes: 3 Foot Ethernet Cable and Plug in Power Adapter, Operating Temperature Range: 32°F to 120°F, Used With: RedLINK enabled thermostats and accessories, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Electrical Ratings: 20 to 30 Vac, Electrical Connections: Screw Terminals, 24 Volt plug in transformer, Power Method: 24 Volt Plug In Transformer, Hardwired, Switch Position (System): HEAT-OFF-COOL-AUTO-EM.HEAT, Terminal Designation: R, C then RedLINK to Equipment Interface Module, Outdoor Sensor: Yes, optional The RedLINK Internet Gateway provides remote access to any RedLINK enabled thermostat through the internet, smart phone or tablet., RedLINK enabled to communicate with compatible wireless devices, 3 foot ethernet cable included., Simple installation to home or business router., Easily change system modes and indoor temperature through the web portal or mobile app, Multiple HOLD options allows modification of schedule as needed., High/Low temperature and humidity messaging alerts the user when the indoor conditions are too high or too low.
Application: Gas, oil, electric, heat pump, forced warm air, hot water, steam or gravity, Electrical Ratings: EIM - 18 to 30 VAC, 50 Hz; 60 Hz, Changeover: Auto/Manual Selectable, Power Method: Battery (Thermostat), Programmability: 5-1-1 Day Program or 5-2 Day Program, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT, Cool Current: 1.0 A Running, Heat Current: 1.0 A Running, Fan Current: 0.6 A Running Wireless FocusPro Thermostat, : Installs in minutes. Displays outdoor temperature and humidity. 1 year battery life. 2 month low battery warning. Dual Fuel enabled., Equipment Interface Module (EIM), : All HVAC equipment is wired to the module. Module receives communication from the wireless devices., Return Air Sensor:, Works with the Equipment Interface Module to maintain safe indoor temperatures if power is lost at the wireless thermostat. Maintains 62 F for heating and 82 F for cooling., Redlink Wireless Technology:, Powered by RedLINK reliability. No interference with other wireless devices in the home., Kit Includes:, C7735A1000 Return Air Sensor, THM5320R1000 Equipment Interface Module, TH6320R1004 Wireless FocusPro 5-1-1 Programmable Thermostat, THM6000R1002 RedLINK Internet Gateway, Stages:, Up to 3 Heat / 2 Cool Heat Pump or Up to 2 Heat / 2 Cool Conventional, Terminal Designations:, C, R, Rc, Rh, W-O/B, W2-Aux/E, Y, Y2, G, L, RAS
Size: 16" x 8", Voltage: 24 Vac, Application: Parallel Blade Damper, Shape: Rectangular, Used With: Zoning Systems, Frequency: 60 Hz, Electrical Connections: 4" Leadwire, Motor: Power Closed, Spring Open, Motor Timing: 30 Seconds Power Open/10 Seconds Spring Return, Wires to Motor: 2, Motor Electrical Rating Current: 0.32 A, Motor Finish: Zinc-Plated Steel, Anodized Aluminum, Motor Mount: Side, Motor Mounting Means: Direct Connection to Damper Shaft, Motor Mounting Position: Multi-Poise, Motor Nominal Angular Rotation: 90°, Other Motor Information: Range Stops Kevlar gearing reduces wear, more than doubling damper life, Simple, easy-to-wire, two-wire installation., Reliable spring-return motor, Adjustable range stops., Mechanical visual position indicator for damper status., Solid construction using extruded aluminum frame and blades, Fail-safe, normally open operation., Parallel blade design for low leakage performance., Reliable, strong, 24-volt spring-return motor., Compatible with conventional and networked zoning., Damper can be installed in any orientation (mounting side can be on either the bottom or the side of the duct).
Application: Robust Field Service Replacement Igniter, Mounting Bracket: Multiple Brackets To Adapt As Field Replacement Of Norton / St. Gobain Silicon Carbide Igniters The Q3200U uses a 120 volt silicon nitride igniter design with long life and high resistance to damage or burn out in the appliance., Includes the specially designed silicon nitride igniter and six different bracket configurations to adapt the igniter to the specific appliance application along with accessory parts to allow mounting and wiring the igniter., Clear instructions and application templates are provided to simplify selection of the proper bracket and ease installation of the replacement.
Operating Humidity Range: 0% to 95% Non-Condensing, Frequency: 60 Hz, Flame Failure Response Time: 2 Seconds max @ 1µA, Operating Ambient Temperature Range: -40°F to +175°F (-40°C to +79°C), Circulator Load: 14.5FLA / 25LRA max @120Vac, Cool Fan Off Delay: 0 or 60 seconds, Cool Fan On Delay: 5 seconds, Cooling Contactor Used With: Any 24Vac Contactor Rated at 1.0A or Less, Heat Off Fan Delay: 60, 90, 120, or 180 Seconds, Heat On Fan Delay: 30 or 60 seconds, HSI Warmup Time: 17/27 or 30/30 seconds, Igniter Current: 1.0A resistive @ 95Vac output, Ignition Trial Time: Three, Two Tries if Flame is not Sensed, Induced Draft Blower Load: 2.2FLA / 25LRA max @120Vac, Interpurge: 60 seconds, Line Voltage: 120Vac (97-132 Vac), Low Voltage: 24V (18-30Vac), Number of LEDs: 3, PostPurge: 15 seconds, PrePurge: 30 seconds, Thermostat Anticipator Setting: (Stage 1 only) 100mA, Trial For Ignition: 4, 6, or 8 seconds, Type of Fan Used With: Standard Induction-Type Circulating Fan Main burner ignition using a 120V hot surface igniter., Flame rectification circuit to monitor flame presence., Monitoring of system pressure switch, high temperature limit, and rollout functions, Appliance operation/safety requirements controlled via microprocessor, LED system status, performance and diagnostic indication., Control of a standard induction-type circulating fan motor (based on appliance requirements), in response to a conventional low voltage or EnviraCOM thermostat., Application:, Used with conventional thermostats as well as the EnviraCOM enabled VisionPRO IAQ and FocusPRO., Universal Integrated Furnace Control is intended for residential natural or liquid propane fueled furnaces only.
Color: Arctic White, Application: Up to 4 Heat/2 Cool Heat Pumps, Up to 3 Heat/2 Cool Conventional Systems, Operating Temperature Range: 32°F to 120°F, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Frequency: 60 Hz,50 Hz, Display Size: 8.06 sq in., Electrical Ratings: 18 to 30 VAC, Changeover: Auto or Manual, Dehumidification Setting Range: 40 to 80% RH, Electrical Connections: Screw Terminals, Humidification Setting Range: Cooling: 40 to 80% RH, Heating: 10 to 60% RH, Power Method: Hardwired, Programmability: 7-Day Multiple Day Programming or Non-Programmable, Setting Temperature Range: Heat: 40°F to 90°F; Cool 50°F to 99°F, Switch Positions (Fan): AUTO-ON-CIRC, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT Control heating, cooling and IAQ equipment with only 2 wires at the thermostat. Heating, cooling and IAQ equipment wires to the Equipment Interface Module., Patented interview based programming and installer setup, RedLINK wireless communication., Light commercial - commercial language (occupied and unoccupied), schedule holidays and custom events, remote setback, economizer and time of day., All Prestige IAQ 2.0 systems come standard with a return and discharge air temperature sensor to measure Delta T, Delta T Alerts and Diagnostics, Alerts and User Interactions Log - Keeps a searchable history of alerts and setting changes to the thermostat, USB port for transferring Installer Setup, Customizable Reminders, Custom Events and Holidays to multiple thermostats, Customizable Service Reminders, USB port for adding the dealer's full color business logo on the screen, 3 assignable outputs to control humidification, dehumidification, ventilation and a stage of heating or cooling., Tri-lingual - English, French and Spanish display options., Precise temperature control ( 1 F) for reliable and consistent temperature, Multiple staging options to provide comfort or energy savings., Kit Includes:, THX9421R5013 Thermostat, THM5421R1013 Equipment Interface Module and two C7735A1000 Duct Sensor, Used With:, RedLINK enabled thermostats and accessories, Stages:, Up to 4 Heat / 2 Cool Heat Pump or Up to 3 Heat / 2 Cool Conventional, Terminal Designations:, R, C then RedLINK to Equipment Interface Module, UN 3091 Lithium metal batteries packed in/with equipment
Color: Front: White, Side: White, Dimensions: 3-1/2" x 4-1/2" x 7/8", Application: Up to 4 Heat/2 Cool Heat Pumps; Up to 3 Heat/2 Cool Conventional Systems, Operating Temperature Range: 32°F to 120°F, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Frequency: 50 Hz; 60 Hz, Display Size: 8.06 sq in., Electrical Ratings: 18 to 30 VAC, Changeover: Auto or Manual, Dehumidification Setting Range: 40 to 80% RH, Electrical Connections: Screw Terminals, Humidification Setting Range: Cooling: 40 to 80% RH, Heating: 10 to 60% RH, Power Method: Hardwired, Programmability: 7-Day Multiple Day Programming or Non-Programmable, Setting Temperature Range: Heat: 40°F to 90°F; Cool 50°F to 99°F, Switch Positions (Fan): AUTO-ON-CIRC-FOLLOW SCHEDULE, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT, Humidity Sensor Accuracy: ± 5% RH From 30% to 50% RH at 75°F, Temperature Sensor Accuracy: ± 1.5°F at 70°F Control heating, cooling and IAQ equipment with only 2 wires at the thermostat. Heating, cooling and IAQ equipment wires to the Equipment Interface Module., Smart Schedule - programs in seconds for any lifestyle, Patented interview based programming and installer setup., RedLINK wireless communication., Selectable for residential and light commercial applications. Meets commercial code and is title 24 compliant., Light commercial - commercial language (occupied and unoccupied), schedule holidays and custom events, remote setback, economizer and time of day., Delta T Alerts and Diagnostics informs customers when their system is not performing as expected with instructions to contact the dealer. Provides a sense of security and greater comfort while generating repeat business., All Prestige IAQ kits come standard with a return and discharge air temperature sensor to measure Delta T., Alerts and User Interactions Log, Performance Logs - Keeps a history of heating and cooling performance, Customizable Service Reminders, USB port for transferring Installer Setup, Customizable Reminders, Custom Events and Holidays to multiple thermostats., USB port for adding the dealer's full color business logo on the screen., 3 assignable outputs to control humidification, dehumidification, ventilation and a stage of heating or cooling., Extend wireless range of the Equipment Interface Module by connecting a THM4000R1000 Wireless Adapter., Tri-lingual - English, French and Spanish display options., Precise temperature control (+/- 1 F) for reliable and consistent temperature., Multiple staging options to provide comfort or energy savings., Stages:, Up to 4 Heat/2 Cool Heat Pumps; Up to 3 Heat/2 Cool Conventional Systems, Used With:, THM5421R1021 Equipment Interface Module and RedLINK accessories, Terminal Designations:, R, C then RedLINK to Equipment Interface Module, UN 3091 Lithium metal batteries packed in/with equipment
Color: Premier White, Dimensions: 4" diameter x 1-3/4" D, Application: 1 Heat/1 Cool Conventional Systems and Heat Pumps with No Auxiliary Heat, Includes: 6" Cover Ring and Switch Position Labels, Mounting: Round, Comments: EASY-TO-SEE model with Large raised markings and a click at each 2 degree setpoint change, Operating Humidity Range: 5 to 90% RH (Non-Condensing), Stages: 1 Heat/1 Cool, Frequency: 50/60 Hz, Switch Type: Relay, Electrical Ratings: 20 to 30 Vac, Changeover: Manual, Power Method: Battery assisted power stealing, Setting Temperature Range: 40°F to 90°F, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL, Terminal Designation: R, Rc, W, Y, G, O, B, Cool Current: 0.02A to 1.0A Running, Heat Current: 0.02A to 1.0A Running, Sensor Element: Thermistor, Accuracy (°F): ± 2°F, Supply Voltage: 20 to 30 Vac, Cycles per Hour: Adjustable 1, 3, 5, 9 The Round thermostats provide electronic control of 24Vac heating and cooling systems with the classic twist to set dial.
Color: Champagne gold face-plate with beige cover, Dimensions: 4-1/2" H x 2-15/16" W x 1-1/2" D (switches and wiring terminals protrude into outlet box 3/4"), Application: Heating and cooling, Frequency: 50/60 Hz, Differential Temperature: 2°F, Electrical Connections: Flylead, Setting Temperature Range: 44°F to 86°F, Sensor Element: Vapor filled dual diaphragm, Tradeline Value: Super Tradeline, Supply Voltage: 120 to 227 Vac, Approvals, Canadian Standards Association: CSA Certified, File No. LR1322, Approvals, Underwriters Laboratories Inc: Listed: File No. E4436, Guide No. XAPX, Guide No. XAPX., Commercial/Residential: Commercial, Switching Action: SPDT - breaks heating and makes cooling on temperature rise Automatic cooling and heating anticipation., Mount on standard vertical or horizontal outlet box., Light and Medium Duty Line Voltage Thermostats control line voltage valves, motors, contractors, electric heat, elements, duct furnaces, and fan coil units in heating/cooling systems., Includes: Vertical scaleplate with thermometer, horizontal scaleplate with no thermometer, range stops and locking screws, wall plate, and high accuracy Dual Diaphragm sensor, Electrical Ratings: 9.8 FLA / 58.8 LRA @ 120 Vac; 5.6 FLA / 33.6 LRA @ 208 Vac; 4.9 FLA / 29.4 LRA @240 Vac; 4.2 FLA / 25.2 LRA @277 Vac; 22 A @ 120 - 240 Vac Resistive; 19 A @ 277 Vac Resistive.
Voltage: 24 Vac, Dimensions: 5-3/16 in H x 4-1/8" W x 3-1/4" D, Capacity: At 1 in. wc p.d.-- 130,000 BTUh: 20,000 BTUh minimum, Application: Single Stage, Includes: Natural to LP Conversion Kit; One 1/2" x 3/8" reducer bushing; One 3/4" straight flange, Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically, Operating Temperature Range: 0°F to 175°F, Frequency: 60 Hz, Electrical Connections: Combination screw and 1/4 in. male quick connects., Approvals, Canadian Standards Association: 112395, Approvals, Underwriters Laboratories Inc: UL Component Recognized MCCZ2.MH5323, Anticipator Setting: 0.5 A, Approvals, Australian Gas Association: 4717, Body Pattern: Straight-through, Ignition Type: Standing Pilot, Inlet/Outlet Size: 1/2" x 1/2", Opening Characteristics: Standard, Pilot Gas Outlet: Compression fitting for 1/4 in. OD tubing, Pressure Ratings: 1/2 psi, Pressure Regulator Setpoint (in wc): 3.5 in. wc, Pressure Tapping: 1/8 in. NPT with plug, Type of Fuel: Natural
Voltage: 24VAC, Application: Single Stage, Operating Temperature Range: -40°F to +175°F, Frequency: 50 Hz; 60 Hz, Body Pattern: Straight-Through, Ignition Type: Intermittent Pilot, Inlet/Outlet Size: 1/2 in. x 1/2 in., Opening Characteristics: Standard, Pressure Ratings: 1/2 psi, Type of Fuel: Natural; LP, Pressure Regulator Setpoint: 3.5 in. wc Solenoid operated first automatic valve opens on thermostat call for heat and closes when call for heat ends., Diaphragm-operated second automatic valve opens under control of the regulator and closes if gas or power supply is interrupted., Two-position gas control knob has ON and OFF position, All adjustments and wiring connections accessible from top of the control., Compact size, Straight-through body pattern; right angle adapters available for inlet and outlet., 1/2 in. inlet and 1 /2 in. outlet, Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure., Inlet and outlet screens included., Wiring terminal block color-coded brown to indicate direct ignition control., May be installed at any angle between 0 and 90 degrees from the upright position, including vertically., 1/4 in. male quick-connect terminals for electrical connections., lnlet and outlet pressure taps included; both taps accessible from top of control., Approvals:, Canadian Standards Association 112395, Includes:, Natural to LP Conversion Kit; One 1/2" x 3/8" reducer bushing, Mounting, : 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Voltage: 120 VAC, Dimensions: 4-3/16" x 4-1/2" x 2-13/16", Application: For single-or two speed fan, Horsepower: 3/4 HP, Power Consumption: 11 W (max.), Contacts: Silver Cadmium Oxide, Frequency: 60 Hz, Tradeline Value: Tradeline, Supply Voltage: 40 VA; 26.5 V - Secondary, Switching Action: SPDT, Contact Rating (AFL): 12, Contact Rating (ALR): 60, Overload Protection: Inherent, Replacement Relay: R8222B, Switching: SPDT Transformer powers low voltage control systems and provides overload protection., Low voltage terminal board provides convenient connections for thermostat and heating and cooling equipment wiring., Mounts on standard 4 x 4 in. junction box., Relay is easily replaced without disturbing wiring., Certifications & Approvals:, UL Component Recognized; File No. E4436, Vol.15, Sec.1, Guide No.XAPX2, CSA certified File No. LR95329-17
Voltage: 120 VAC, Dimensions: 4-3/16" x 4-1/2" x 2-13/16", Application: For "Total Comfort" applications with electronic air cleaner, humidifier and blower motor, Horsepower: 3/4 HP, Power Consumption: 11 W (max.), Contacts: Silver Cadmium Oxide, Frequency: 60 Hz, Tradeline Value: Tradeline, Supply Voltage: 40 VA; 26.5 V - Secondary, Switching Action: DPDT, Contact Rating (AFL): 12, Contact Rating (ALR): 60, Overload Protection: Inherent, Replacement Relay: R8222D, Switching: DPDT Transformer powers low voltage control systems and provides overload protection., Low voltage terminal board provides convenient connections for thermostat and heating and cooling equipment wiring., Mounts on standard 4 x 4 in. junction box., Relay is easily replaced without disturbing wiring., Certifications & Approvals:, UL Component Recognized; File No. E4436, Vol.15, Sec.1, Guide No.XAPX2, CSA certified File No. LR95329-17
Dimensions: 3-15/16" H x 5-7/16" W x 2-5/8" D, Includes: Damper connection with automatic vent damper plug, Ambient Temperature Range: -40°F to +165°F, Frequency: 60 Hz, Electrical Ratings: 24 Vac, Flame Failure Response Time: 2 seconds maximum, Tradeline Value: Tradeline, Ignition Trial Time: 15 or 90 sec, PrePurge: Configurable to 30 seconds or no prepurge, Approvals, Canadian Standards Association: Design Certified, Between Trial Time: 5 minute delay after failed trial for ignition., Flame Sense: Single Rod or Two Rods, Ignition Sequence: Continuous Retry, Ignition Source: Internal high voltage spark generator, Ignition System Type: Intermittent Pilot, Ignition Trials To Lockout: continuous retry, Lockout Timing: continuous retry, Max Valve Load @ 24 Vac: 1A Pilot, 2A Main @ 165 F; 1A Pilot, 1A Main @ 175 F, Type of Gas: Natural or LP, Typical Gas Control: VR8204, VR8304, Typical Ignition Hardware: Q345, Q3451, Q3452 Provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances., Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed., For use with Natural or LP gas., Functional equivalent of S86, S8600, S8610 and S90 modules., Includes spark cable adapters to allow field replacement of both Honeywell and competitive controls without replacing existing spark cable.
T8775.jpg Digital Round Thermostat, 1H/1C, Premier White
Locke Part #: L4558MFG Part #: T8775C1005/U
Color: Premier White, Dimensions: 3-11/16" diameter x 1-7/16" D, Application: 1 Heat/1 Cool Conventional Systems and Heat Pumps with No Auxiliary Heat, Includes: Wallplate, resistor assembly, mounting screws and wall anchors, Mounting: Round, Comments: Large easy-to-see backlit display, Operating Humidity Range: 5 to 90% RH (Non-Condensing), Stages: 1 Heat/1 Cool, Frequency: 60 Hz, Switch Type: Electronic, Display Size: 0.75 sq in., Electrical Ratings: 18 to 30 Vac, Changeover: Manual, Power Method: Powered through heat-cool system controls, Setting Temperature Range: 40°F to 90°F Heat; 45°F to 99°F Cool, Switch Positions (Fan): AUTO-ON, Switch Positions (System): HEAT-OFF-COOL, Terminal Designation: R, Rc, W, Y, G, O, B, Sensor Element: Thermistor, Accuracy (°F): ±1°F, Supply Voltage: 20 to 30 Vac, Cycles per Hour: Adjustable 1, 3, 6, 9
Voltage: 30 mV; Open Circuit Output--26 mV to 32 mV, Application: Thermocouple, Connection Type: 11/32 32 Male Connector Nut, Lead Length: 18", Tradeline Value: Tradeline, Max DC Cold Resistance @ 80°F: 0.02 ohms, Temperature Ratings: Hot Junction-1400°F; Cold Junction-780° F Q390A thermocouples sense the pilot flame on gas-fired heating systems. The pilot flame heats the tip of the thermocouple, producing a temperature differential between it and the base to generate a small amount of DC power, measured in millivolts.
Voltage: 30 mV; Open circuit output--26 mV to 32 mV, Length: 24", Application: Thermocouple, Includes: Adapter and Push In Clip, Connection Type: 11/32 32 Male Connector Nut, Tradeline Value: Tradeline, Temperature Ratings: Hot Junction - 1400°F; Cold Junction - 780°F, Resistance: 0.02 ohms Q390A thermocouples sense the pilot flame on gas-fired heating systems. The pilot flame heats the tip of the thermocouple, producing a temperature differential between it and the base to generate a small amount of DC power, measured in millivolts.
Voltage: 30 mV; Open circuit output--26 mV to 32 mV, Length: 30", Application: Thermocouple, Includes: Adapter and Push In Clip, Connection Type: 11/32 32 Male Connector Nut, Tradeline Value: Tradeline, Temperature Ratings: Hot Junction - 1400°F; Cold Junction - 780°F, Resistance: 0.02 ohms Q390A thermocouples sense the pilot flame on gas-fired heating systems. The pilot flame heats the tip of the thermocouple, producing a temperature differential between it and the base to generate a small amount of DC power, measured in millivolts.
Voltage: 30 mV; Open circuit output--26 mV to 32 mV, Length: 36", Application: Thermocouple for Standing Pilot Applications, Includes: Adapter and Push In Clip, Connection Type: 11/32 32 Male Connector Nut, Tradeline Value: Tradeline, Temperature Ratings: Hot Junction - 1400°F; Cold Junction - 780°F, Resistance: 0.02 ohms Q390A thermocouples sense the pilot flame on gas-fired heating systems. The pilot flame heats the tip of the thermocouple, producing a temperature differential between it and the base to generate a small amount of DC power, measured in millivolts.
Voltage: 30 mV; Open Circuit Output--26 mV to 32 mV, Application: Thermocouple, Connection Type: 11/32 32 Male Connector Nut, Lead Length: 48", Tradeline Value: Tradeline, Max DC Cold Resistance @ 80°F: 0.03 ohms, Temperature Ratings: Hot Junction-1400°F; Cold Junction-780° F Q390A thermocouples sense the pilot flame on gas-fired heating systems. The pilot flame heats the tip of the thermocouple, producing a temperature differential between it and the base to generate a small amount of DC power, measured in millivolts.
Dimensions: 4-9/32" H x 3" W x 1-19/32" D excluding element, Application: Forced Warm Air Heating Systems, Mounting: Surface or universal mounting bracket available (50077438-001/U), Operating Temperature Range: -40°F to +190°F, Temperature Range: Maximum Ambient-- At switch: 190°F: At element: 350°F; High Limit-- 100°F to 250°F; Fan-on-- 65°F to 215°F; Fan-off-- 50°F to 200°F; High Limit Stop-- 200°F; Fan-on Stop-- 125°F; Fan-off , Differential Temperature: High Limit 25°F (14°C), Tradeline Value: Tradeline, Element Insertion Length: 11-1/2", Approvals, Canadian Standards Association: Certified: File No. LR1622, Approvals, Underwriters Laboratories Inc: Listed File MP466, Guide MBPR, Switching Action: Fan switch makes and high limit switch breaks on temperature rise., Pilot Duty Ratings: 0.25 A @ 0.25 to 12 Vdc; 2 A @ 24 Vac Three wiring terminal options available for easy installation., Push-in receptacles for stripped wire., Female receptacles for 1/4 inch male flag connectors., Auxiliary screw terminals., Field adjustable fan and high limit settings., L4064B,W, and R models have a manual fan switch that overrides the fan control to keep the fan running continuously., TRADELINE models with mounting adapters for easy installation and strain relief bushings to protect wiring from field abuse., Electrical Ratings, : Fan- (AFL)-- 14 A @ 120 Vac: 7 A @ 240 Vac; Fan- (ALR)-- 84 A @ 120 Vac: 42 A @ 240 Vac; Limit- (AFL)-- 8 A @ 120 Vac: 4 A @ 240 Vac; Limit- (ALR) 48 A @ 120 Vac: 24 A @ 240 Vac
Dimensions: 4-9/32" H x 3" W x 1-19/32" D excluding element, Application: Forced Warm Air Heating Systems, Mounting: Surface or universal mounting bracket available (50077438-001/U), Operating Temperature Range: -40°F to +190°F, Temperature Range: Maximum Ambient-- At switch: 190°F: At element: 350°F; High Limit-- 100°F to 250°F; Fan-on-- 65°F to 215°F; Fan-off-- 50°F to 200°F; High Limit Stop-- 200°F; Fan-on Stop-- 125°F; Fan-off , Differential Temperature: High Limit 25°F (14°C), Tradeline Value: Tradeline, Element Insertion Length: 8", Approvals, Canadian Standards Association: Certified: File No. LR1622, Approvals, Underwriters Laboratories Inc: Listed File MP466, Guide MBPR, Switching Action: Fan switch makes and high limit switch breaks on temperature rise., Pilot Duty Ratings: 0.25 A @ 0.25 to 12 Vdc; 2 A @ 24 Vac Three wiring terminal options available for easy installation., Push-in receptacles for stripped wire., Female receptacles for 1/4 inch male flag connectors., Auxiliary screw terminals., Field adjustable fan and high limit settings., L4064B,W, and R models have a manual fan switch that overrides the fan control to keep the fan running continuously., TRADELINE models with mounting adapters for easy installation and strain relief bushings to protect wiring from field abuse., Electrical Ratings, : Fan- (AFL)-- 14 A @ 120 Vac: 7 A @ 240 Vac; Fan- (ALR)-- 84 A @ 120 Vac: 42 A @ 240 Vac; Limit- (AFL)-- 8 A @ 120 Vac: 4 A @ 240 Vac; Limit- (ALR) 48 A @ 120 Vac: 24 A @ 240 Vac
Dimensions: 4-9/32" H x 3" W x 1-19/32" D excluding element, Application: Forced Warm Air Heating Systems, Mounting: Surface or universal mounting bracket available (50077438-001/U, Operating Temperature Range: -40°F to +190°F, Temperature Range: Maximum Ambient-- At switch: 190°F: At element: 350°F; High Limit-- 100°F to 250°F; Fan-on-- 65°F to 215°F; Fan-off-- 50°F to 200°F; High Limit Stop-- 200°F; Fan-on Stop-- 125°F; Fan-off , Differential Temperature: High Limit 25°F (14°C), Tradeline Value: Tradeline, Element Insertion Length: 5", Approvals, Canadian Standards Association: Certified: File No. LR1622, Approvals, Underwriters Laboratories Inc: Listed File MP466, Guide MBPR, Switching Action: Fan switch makes and high limit switch breaks on temperature rise., Pilot Duty Ratings: 0.25 A @ 0.25 to 12 Vdc; 2 A @ 24 Vac Three wiring terminal options available for easy installation., Push-in receptacles for stripped wire., Female receptacles for 1/4 inch male flag connectors., Auxiliary screw terminals., Field adjustable fan and high limit settings., L4064B,W, and R models have a manual fan switch that overrides the fan control to keep the fan running continuously., TRADELINE models with mounting adapters for easy installation and strain relief bushings to protect wiring from field abuse., Electrical Ratings, : Fan- (AFL)-- 14 A @ 120 Vac: 7 A @ 240 Vac; Fan- (ALR)-- 84 A @ 120 Vac: 42 A @ 240 Vac; Limit- (AFL)-- 8 A @ 120 Vac: 4 A @ 240 Vac; Limit- (ALR) 48 A @ 120 Vac: 24 A @ 240 Vac
Type: Single Stage, Dimensions: 5 3/8" x 4 1/16" x 2 11/16", Capacity: 200,000 BTU/hr, Application: Used In Gas Fired Appliances, Temperature Range: 0° F to 175° F, Frequency: 60 Hz, Electrical Ratings: 24 Vac, Electrical Connections: 1/4" Quick-Connect Male Terminals, Anticipator Setting: 0.7 A, Body Pattern: Straight Through With Integral Tapping; With Flange, Ignition Type: Standing Pilot, Inlet/Outlet Size: 3/4" x 3/4", Pilot Gas Outlet: Compression Fitting For 1/4" OD Tubing, Pressure Ratings: 1/2 psi, Pressure Tapping: 1/8 in. NPT with plug, Type of Gas: Natural, Pressure Regulator Setting (psi): 3.5" wc Controls include manual valve, two automatic operators, servo pressure regulator and pilot adjustment., Compact size, Provide two automatic valves., Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends., Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted., Meet codes requiring dual safety shutoff., Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves., LITE-RITE (OFF-PILOT-ON) lighting sequence., All adjustments, wiring connections and pilot outlet are accessible from top of control., Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure., 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically., Compatible with ECO connector., AGA Design Certificate., CGA Design Certificate.
Voltage: 24 Vac, Dimensions: 5-3/8" H x 4-1/16" W x 2-11/16" D, Capacity: At 1 in. wc p.d.-- 300,000 BTUh: 30,000 BTUh minimum, Application: Single Stage, Includes: Two 3/4 x 1/2 in. reducer bushings; Natural to LP Conversion Kit, Mounting: 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically, Operating Temperature Range: -40°F to +175°F, Frequency: 60 Hz, Electrical Connections: 1/4 in. quick-connect male terminals, Approvals, Canadian Standards Association: 112395, Approvals, Underwriters Laboratories Inc: UL Component Recognized., Body Pattern: Straight-through, Ignition Type: Direct Ignition; Intermittent Pilot, Inlet/Outlet Size: 3/4" x 3/4", Pressure Ratings: 1/2 psi, Pressure Regulator Setpoint (in wc): 3.5 in. wc, Pressure Tapping: 1/8" NPT with plug, Type of Fuel: Natural, Approvals, American Gas Association: AGA Design Certificate: L2025007, Approvals, Canadian Gas Association: CGA Design Certified: File No. L2025007.
Application: Provide Pilot Flame Ignition, Orifice: 0.018", Mounting Bracket: B, Type of Gas: Natural, Aeration: Non-primary, Compression Fitting Length: 0.78", Compression Fitting Size: 1/4", Direction of Front Tip: Front, Leadwire Temperature Ratings: 968° C, Tip Style: Single Includes pilot burner with bracket, ceramic-insulated Kanthal flame rod/spark igniter and ground strap., Single tip style., Special mounting bracket with screws to convert "B" bracket to "A" bracket.
Voltage: 750 mV, Dimensions: 4-3/4" x 4-1/16" x 3-3/16", Application: Self-powered automatic control. Use with 750 mV pilot generator, Operating Temperature Range: 32°F to 175°F, Inlet/Outlet Size: 3/4" x 3/4" NPT with 1/2" NPT Side Outlets, Opening Characteristics: Standard, Pilot Gas Outlet: Compression Fitting For 1/4" OD Tubing, Pressure Ratings: 1/2 psi, Pressure Tapping: 1/8" NPT With Plug, Type of Fuel: Natural, Pressure Regulator Setpoint: 3.5 in. wc Reg. Set/3-5" Adj. Range, Pressure Regulator: Standard Include pilot flow adjustment screw., Easy to install, adjust and service; all adjustments and connections are accessible from top of control., Add separate energy cutoff (ECO) where codes call for dual safety shutoff., Complete safety shutoff on pilot flame failure., LITE-RITE (OFF-PILOT-ON) lighting sequence., Can be mounted from 0 to 90 degrees from the vertical position of the gas control knob, If gas or power supply is interrupted, main gas valve is closed., In case of pilot flame failure, main valve is closed., Left and right side outlets in addition to the straight-through outlet., Reducer fittings included to fit variety of sizes.., Includes:, One 1/2" x 3/8" reducer bushing; Two 3/4" x 1/2" reducer bushings; One Natural to LP Conversion Kit; Remote Rod Adapter, Mounting:, 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically., Electrical Connections:, Terminal block has 3 combination screw and 1/4 in. quick connect terminals., Body Pattern:, Straight-through, multi-tapped with 1/2 in. right and left outlets plugged, Approvals:, UL Component Recognized MH5323, Canadian Standards Association 112395
R8222V1003.jpg 24 V General Purpose Relay with Dpdt Switching
Locke Part #: L4590MFG Part #: R8222N1011/U
Dimensions: 1 7/8" x 2 5/32" x 2 3/8", Application: General Purpose Switching, Frequency: 50 Hz/60 Hz, Electrical Connections: 1/4" Quick-Connect Terminals, Switching: DPDT - Pilot Duty, Temperature Ratings: -20° F to +155° F, Coil Ratings Voltage: 24 Vac Molded terminal numbers and circuit diagram on top of relay provide easy identification for wiring and checking system operation., Open coil assures cooler operation., Laminated magnet construction for higher efficiency., Base designed for easy replacement of competitive relays., Double quick-connect coil terminals., Plug compatible with Steveco 90-340 and Mars 90340., Contacts rated for voltages upto 600 VAC., Approvals:, UL Listed: File No. E59779, Guide No. NLDX2, Canadian Standards Association Certified: File No. LR35066, Guide No. 184-N-13.13
Dimensions: 1-7/8" x 2-5/32" x 2-3/8", Frequency: 50 Hz; 60 Hz, Electrical Connections: 1/4" Quick-Connect Terminals, Tradeline Value: Tradeline, Contact Rating (AFL): 3 A @ 480 Vac; 6 A @ 208 Vac, 240 Vac, 277 Vac; 12 A @ 120 Vac, Contact Rating (ALR): 18 A @ 480 Vac; 35 A @ 208 Vac, 240 Vac, 277 Vac, 60 A @ 120 Vac, Switching: DPDT (1 P&1 Pilot Duty), Temperature Ratings: -20° F to +155° F, Coil Ratings Voltage: 24 VAC, Contact Ratings (Resistive): 10 A @ 480 Vac; 20.8 A @ 120 Vac, 208 Vac, 240 Vac, 277 Vac, Pilot Duty Ratings (Max): 25 VA @ 24 Vac, 125 VA @ 120 Vac, 240 Vac, & 480 Vac, Pilot Duty Ratings (Min): 3 VA @ 24 Vac, 120 Vac, & 480 Vac, Pilot Duty Ratings (PowerPile): (Normally Open Contacts Only) 0.25 A @ 0.25 to 12 Vdc, Pilot Duty Ratings (Resistive): 3 A @ 277 Vac (0.75 Power Factor) Molded terminal numbers and circuit diagram on top of relay provide easy identification for wiring and checking system operation., Open coil assures cooler operation., Laminated magnet construction for higher efficiency., Base designed for easy replacement of competitive relays., Double quick-connect coil terminals., Plug compatible with Steveco 90-340 and Mars 90340., Contacts rated for voltages upto 600 VAC., Approvals:, UL Listed: File No. E59779, Guide No. NLDX2, Canadian Standards Association Certified: File No. LR35066, Guide No. 184-N-13.13
Dimensions: 5-1/4" H x 4-1/16" W x 1-15/16" Long, Ambient Temperature Range: -40°F to +175°F, Frequency: 60 Hz, Electrical Ratings: 24 Vac, Flame Failure Response Time: 1.5 sec., Tradeline Value: Tradeline, Ignition Trial Time: 4 sec. or 7 sec., PrePurge: 32 seconds, Approvals, Canadian Standards Association: Design Certified, Between Trial Time: (2) 96 sec.- 3 trial mode only, Flame Sense: Single Rod or Two Rods, Ignition Source: Line Voltage (120 VAC) Hot Surface Element (Norton Model 201 or 270), Ignition System Type: Direct Hot Surface Ignition, Ignition Trials To Lockout: 1 or 3, Lockout Timing: 4 sec. or 7 sec., Max Valve Load @ 24 Vac: 2A, Type of Gas: Natural or LP, Typical Gas Control: VR8205, VR8305, Typical Ignition Hardware: Norton 201, Norton 271, Q354 Replaces many White-Rodgers, Robertshaw and Honeywell hot surface ignition models., For 120 Vac (up to 5.0A) surface igniter (Norton 201/271 or equivalent)., For local (single rod) or remote (dual rod) rectification type flame sensing., Contains easy-to-use instructions plus the accessories required to adapt the existing hot surface ignition module., Provides one or three ignition trials (four-second or seven-second trials) per call for heat; prepurge of 32 seconds or less; up to 96 seconds between purge trial times., Specifications:, Ignition Sequence, The number of trials for ignition and trial time is determined by the selection tab. If a selection tab is not installed, the module will operate at four seconds trial time and one ignition trial.
Color: Gray, Type: Dehumidifier, Voltage: 120V, Weight: 55 lb, Dimensions: 31" x 15" x 16", Capacity: 65 pints Per Day, Drain Connection: 3/4" Threaded Female NPT, With Attached 3/4" Threaded Male NPT, Refrigerant: R-410A, Operating Temperature Range: 34° - 135° F (Outside Cabinet), Electrical Ratings: 5.2 A, Supply Voltage: 120 VAC; 60 Hz, Blower: 160 CFM @ 0.0 in. WG, 100 CFM @ 0.6 in. WG, Coverage: Up to 1800 sq. ft., Duct Connections: 8" Round Inlet, 8" Round Outlet (ABS Plastic), Energy Performance: 2.22 Liters (4.7 pints) per Kilowatt Hour (KWH) Energy, Filter Efficiency: Standard MERV-11, Plenum Opening: Diameter- 8" Collars, Power Transformer To R/C Terminals: 24 VAC, 0.85A Removes up to 65 pints (30.8 l) of water per day from the indoor air., Built-in humidity control requires no additional wiring to an external control., Energy Star 3.0 rated., Electrocoating reduces coil corrosion and helps prevent refrigerant leaks, Top or side ducted exhaust, Reduced noise during operation, MERV 11 air filtration, Simplified Wiring, ETL Listed, Conforms to UL Std. 474., Includes:, Four leveling feet with rubber isolation pads.
Color: White, Type: Steam Humidifier, Voltage: 24 VAC, Dimensions: 19" x 11-1/4" x 9", Mounting: Duct or Remote Mount (up to 20 feet/6 meters), Operating Temperature Range: 1.1°C-40°C Fully enclosed, SPST, snap-acting, dust-proof switch are designed for wall or surface duct mounting, Accurate control of humidifiers and dehumidifiers or ventilators
Size: 8", Application: Constant Pressure Regulating (Bypass) Damper, Gauge: 26, Shape: Round, Ambient Temperature Range: 0°F-165°F, Motor or Actuator Mounting: Quick Connect Regulator, Motor: Calibrated Spring Tension Regulator, Damper Type: Bypass, Max Airflow: 600 CFM, Storage Temperature Range: 30°F-150°F Quick installation and setup, No weight to adjust, Can be installed in any orientation, Engineered to provide constant system pressure regardless of changes in zones celling or blower speed
Size: 10", Application: Constant Pressure Regulating (Bypass) Damper, Gauge: 26, Shape: Round, Ambient Temperature Range: 0°F-165°F, Motor or Actuator Mounting: Quick Connect Regulator, Motor: Calibrated Spring Tension Regulator, Damper Type: Bypass, Max Airflow: 1000 CFM, Storage Temperature Range: 30°F-150°F Quick installation and setup, No weight to adjust, Can be installed in any orientation, Engineered to provide constant system pressure regardless of changes in zones celling or blower speed
Size: 12", Application: Constant Pressure Regulating (Bypass) Damper, Gauge: 24, Shape: Round, Ambient Temperature Range: 0°F-165°F, Motor or Actuator Mounting: Quick Connect Regulator, Motor: Calibrated Spring Tension Regulator, Damper Type: Bypass, Max Airflow: 1400 CFM, Storage Temperature Range: 30°F-150°F Quick installation and setup, No weight to adjust, Can be installed in any orientation, Engineered to provide constant system pressure regardless of changes in zones celling or blower speed
Size: 14", Application: Constant Pressure Regulating (Bypass) Damper, Gauge: 22, Shape: Round, Ambient Temperature Range: 0°F-165°F, Motor or Actuator Mounting: Quick Connect Regulator, Motor: Calibrated Spring Tension Regulator, Damper Type: Bypass, Max Airflow: 1700 CFM, Storage Temperature Range: 30°F-150°F Quick installation and setup, No weight to adjust, Can be installed in any orientation, Engineered to provide constant system pressure regardless of changes in zones celling or blower speed
Color: White, Frequency: 50 Hz; 60 Hz, Electrical Ratings: 18 to 30 Vac, Changeover: Auto/Manual, Dehumidification Setting Range: 40 to 80% RH, Electrical Connections: Push Terminals, Power Method: Hardwired, Battery Back-up, Power Transformation, Programmability: Programmable with Geofencing, Switch Positions (Fan): AUTO-ON-CIRC, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT, Supply Voltage: 18 to 30 Vac, Operating Humidity Range (% RH): 5 to 90% RH, non-condensing, Operating Temperature Range (F): 32 F to 120 F, Terminal Designations: R, Rc, W-O/B, W2-Aux/E. Y, Y2, G, C, K, L, U1, U2, Display: Round, Humidification Setting Range Cooling: 40 to 80% RH. Heating: 10 to 60% RH Control from anywhere by smart phone or tablet, Geofencing technology uses your smart phone's location to optimize savings and comfort, Fine Tune option keeps you comfortable by considering indoor and outdoor temperature and humidity to create "real feel" comfort., Create shortcuts for your more predictable life events, Smart Cues feature notifies you of important information to help extend the life of your system, Unlike competition, efficiency is based on thermostat adapting to your varied schedule,, Thermostat and app language set by your smart phone or tablet, Stages: Up to 3 Heat/2 Cool Heat Pumps; Up to 2 Heat/2 Cool Conventional Systems. Underwriters Laboratories Inc, Federal Communications Commission Approved, Application: Up to 3 Heat/2 Cool Heat Pumps; Up to 2 Heat/2 Cool Conventional Systems
Product Image Not Available TH8321WF1001 WIFI 3H2C W /HUMID CNTRL & VNTLATION
Locke Part #: L5276MFG Part #: TH8321WF1001/U
Product Image Not Available EQUIPMENT INTERFACE MODU LE
Locke Part #: L5277MFG Part #: THM5320R1000/U
Product Image Not Available FRESH AIR VNTLATION CNTR W8150A1001
Locke Part #: L5278MFG Part #: W8150A1001/U
Product Image Not Available TAZ-4 ADD-A-ZONE CONTROL PANEL
Locke Part #: L5279MFG Part #: TAZ-4/U
Product Image Not Available Smart Valve III f/SX-80 & SX90 -2 to -4
Locke Part #: L5884MFG Part #: SV9502H 2704
VNT5150E1000.jpg TrueFRESH 150 cfm Energy Recovery Ventilator
Locke Part #: L7129MFG Part #: VNT5150E1000/U
Application: Energy Recovery Ventilator, Operating Temperature Range: 34-135°F (1.1-57.2° C), CFM: 30-160, Operating Humidity Range: 0-99% RH, Frequency: 60 Hz, Electrical Ratings: 120 VAC, Airflow Capacity (cfm): 159 Cfm At External Static Pressure 0.4 in. wc, Current Draw: 1.5A, Tradeline Value: Tradeline, Cabinet: 20 Gauge Galvanized Steel Powder-Coat Painted, Defrost Control: Exhaust Only Defrost, Defrost Type: Evacuation, Drain Tubing Diameter: 1/2" (12.7 mm), Exchange Surface: 85 sq. ft., Flexible Duct (2): 6" Round For Inlet And Outlet, Materials: Enthalpy 10 inch ERV Core, Output Power To Terminals: 5 VDC, 1.0 A, Product Weight: 42 lbs (19 Kg), Sensible Effectiveness: 0.67, Type of Heat Exchanger: Cross-Flow (Enthalpic) Removable Duct Collars, Damperless Balancing, Adjustable Hanging Straps, Centralized Wiring and Speed Control, Customizable, Compact Size, 2 operating modes (Intermittent and Continuous Ventilation), Variable speed, Sloped drain pan, Backward inclined motor blades, Permanent lubrication of PSC motors, Door opens downward, No obstruction around the drain pan, Simple electronic control, Easy access to the control connection box, Detachable 6 inch (dia.) collar system, Proportional defrost, Speed control balancing system, Simplified mounting system, Washable ERV core, 10-year limited warranty on ventilation motors, 5-year warranty
Color: Gray, Type: Dehumidifier, Voltage: 120V, Weight: 82 lb, Dimensions: 40" x 18-1/2" x 21-1/2", Capacity: 90 pints Per Day, Drain Connection: 3/4" Threaded Female NPT, With Attached 3/4" Threaded Male NPT, Refrigerant: R-410A, Operating Temperature Range: 34° - 135° F (Outside Cabinet), Electrical Ratings: 6.3 A, Supply Voltage: 120 VAC; 60 Hz, Blower: 262 CFM @ 0.0 in. WG, 106 CFM @ 0.6 in. WG, Coverage: Up to 2800 sq. ft., Duct Connections: 6" Supply Inlet, 8" Round Inlet, 8" Round Outlet (ABS Plastic), Energy Performance: 2.9 liters (6.1 pints) per Kilowatt Hour (KWH) Energy, Filter Efficiency: Standard MERV-11, Plenum Opening: Diameter- 10" Collars; 6" Ventilation Collar, Power Transformer To R/C Terminals: 24 VAC, 0.85A Removes up to 90 pints of water per day from the indoor air., Built-in fresh air supply., Energy Star 3.0 rated., Electrocoating reduces coil corrosion and helps prevent refrigerant leaks, Top or side ducted exhaust, Reduced noise during operation, MERV 11 air filtration, Simplified Wiring, ETL Listed, Conforms to UL Std. 474., Includes:, Four leveling feet with rubber isolation pads.
Color: Premier White, Dimensions: 3-1/2" x 4-1/2" x 7/8", Application: Up to 3 Heat/2 Cool Heat Pumps; Up to 2 Heat/2 Cool Conventional Systems, Mounting: Horizontal, Operating Temperature Range: 32°F to 120°F, Operating Humidity Range: 5 to 90% RH, Non-Condensing, Frequency: 50 Hz; 60 Hz, Display Size: 8.06 sq in., Electrical Ratings: 18 to 30 VAC, Changeover: Auto or Manual, Power Method: Hardwired, Programmability: 7-Day Multiple Day Programming or Non-Programmable, Setting Temperature Range: Heat: 40°F to 90°F; Cool 50°F to 99°F, Switch Positions (Fan): AUTO-ON-CIRC-FOLLOW SCHEDULE, Switch Positions (System): HEAT-OFF-COOL-AUTO-EM.HEAT, Scheduling: On-line scheduling or Locally at thermostat Get Connected- Connect to home s existing Wi-Fi network, Remote Control- Convenience, comfort and control from anywhere through web, tablet or smartphone access, Apps available for tablet and smartphones, Automatic software updates through Wi-Fi, Selectable to 7 Day or Non-Programmable, Program thermostat locally or over the web or app, Customize the screen color, Used With:, THP9045 Wire Saver, Stages:, Up to 3 Heat/2 Cool Heat Pump; Up to 2 Heat/2 Cool Conventional, Terminal Designations:, R, RC, C, W (O/B), W2 (AUX/E), Y, Y2, G, L, K
Product Image Not Available GAS VALVE REPLCMNT DIREC T IGNTN SLOW OPENING
Locke Part #: L7181MFG Part #: VR8215T1502/U
CHC8080W1000-c1.jpg C1 Security Camera
Locke Part #: L7195MFG Part #: CHC8080W1000/U
Width: 2.375, Height: 6, Length: 5 085267503358
Weight: 2.75 lbs., Dimensions: 6-1/2" H x 3-3/32" W, Capacity: 22 Cv, Connection Size: 1" bottom inlet, Connection Type: Female NPT, Pipe Size: 1", Material (Body): Bronze, Max Diameter: 2-3/32", Max Operating Temperature: 240°F (115°C), Max Safe Operating Pressure: 125 psi No clog vent. Dirt and Debris resistant, 360 degree adjustable collar ring for installation flexibility, Threaded connections., Stainless steel concentrator which eliminates gurgling noise. Bronze body for rigid construction., Application:, Residential or Commercial closed loop hydronic heating or chilled water systems.
Weight: 3.5 lbs., Dimensions: 7-27/32" H x 3-11/16" W, Capacity: 38 Cv, Connection Size: 1-1/4" bottom inlet, Connection Type: Female NPT, Pipe Size: 1-1/4", Material (Body): Bronze, Max Diameter: 2-1/2", Max Operating Temperature: 240°F (115°C), Max Safe Operating Pressure: 125 psi No clog vent. Dirt and Debris resistant, 360 degree adjustable collar ring for installation flexibility, Threaded connections., Stainless steel concentrator which eliminates gurgling noise. Bronze body for rigid construction., Application:, Residential or Commercial closed loop hydronic heating or chilled water systems.
Weight: 2 lbs., Dimensions: 6-29/32" H x 2-11/16" W, Capacity: 13 Cv, Connection Size: 3/4" bottom inlet, Connection Type: Female NPT, Pipe Size: 3/4", Material (Body): Bronze, Max Diameter: 1-13/16", Max Operating Temperature: 240°F (115°C), Max Safe Operating Pressure: 125 psi No clog vent. Dirt and Debris resistant, 360 degree adjustable collar ring for installation flexibility, Threaded connections., Stainless steel concentrator which eliminates gurgling noise. Bronze body for rigid construction., Application:, Residential or Commercial closed loop hydronic heating or chilled water systems.