Loading ...

Loading ...

Search in: ICM CONTROLS

Warranty: 3 years from MFR date; 1 year from install date. 800442029511
Warranty: 3 years from MFR date; 1 year from install date. 800442000046
Warranty: 3 years from MFR date; 1 year from install date. 800442000084
Warranty: 3 years from MFR date; 1 year from install date. 800442014333
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 18-240 VAC, Weight: 0.1, Dimensions: 2” x 2”, Width: 2, Height: 1.25, Length: 2, Frequency: 50-60 Hz, Holding Current Minimum: 40 mA, Adjustable Time Delay: .03-10 minutes Universal voltage operation, Higher 1.5 amp power rating, Knob-adjustable time delays, Works with anticipator-type thermostats, One model replaces many in field, Ideal for compressor staging, 1.5 amps, 15 amp inrush 800442000343
ICM200_zm.jpg Delay on Break Timer, 3 minutes fixed
Locke Part #: L4751MFG Part #: ICM200B
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 18-30 VAC, Weight: 0.1, Dimensions: 2” x 2”, Width: 2, Height: 1.25, Length: 2, Frequency: 50-60 Hz, Holding Current Minimum: 40 mA, Fixed Time Delay: 3 minute fixed Compressor lockout/anti-short cycle timer, Helps to protect compressors from damage caused by rapid short cycling, Simple, 2-wire hookup, Fixed timing, 18-30 VAC, 1.5 amps, 15 amp inrush, Voltage drop:, 3.5 V typical, 4.5 V maximum @ 1.5 amps 800442000473
ICM201_zm.jpg Delay on Break Timer, 5 minutes fixed
Locke Part #: L4752MFG Part #: ICM201B
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 18-30 VAC, Weight: 0.1, Dimensions: 2” x 2”, Width: 2, Height: 1.25, Length: 2, Frequency: 50-60 Hz, Holding Current Minimum: 40 mA, Fixed Time Delay: 5 minute fixed Compressor lockout/anti-short cycle timer, Helps to protect compressors from damage caused by rapid short cycling, Simple, 2-wire hookup, Fixed timing, 18-30 VAC,, 1.5 amps, 15 amp inrush, Voltage drop:, 3.5 V typical, 4.5 V maximum @ 1.5 amps 800442000503
ICM203-n_zm.jpg Delay on Break Timer, 10 minutes adj.
Locke Part #: L4753MFG Part #: ICM203B
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 18-240 VAC, Weight: 0.1, Dimensions: 2” x 2”, Width: 2, Height: 1.25, Length: 2, Frequency: 50-60 Hz, Holding Current Minimum: 40 mA, Adjustable Time Delay: 03-10 minutes Compressor lockout/anti-short cycle timer, Helps to protect compressors from damage, caused by rapid short cycling, Simple, Universal voltage, 2-wire hookup, Adjustable timing,, 1.5 amps, 15 amp inrush, 40 mA holding current, Voltage drop:, 3.5 V typical, 4.5 V maximum @ 1.5 amps 800442000169
ICM253_zm.jpg Fan Delay Timer, adj. off delay
Locke Part #: L4754MFG Part #: ICM253B
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 18-30 VAC, Weight: 0.15, Dimensions: 2” x 3”, Width: 3, Height: 1.25, Length: 2, Adjustable Time Delay: OFF-12-390 seconds UL 873 recognition for compressor applications, Post-purge fan delay timer, OFF delay purges ducts of residual air at the end of the heating/cooling cycle, Interrogation delay eliminates nuisance trips due to thermostat bounce/tampering, Specifications:, Output:, 1 amp, maximum, 40 ma minimum, 10 amp inrush 800442000688
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 18-30 VAC, Weight: 0.15, Dimensions: 2” x 3”, Width: 3, Height: 1.25, Length: 2, Adjustable Time Delay: ON-1-180 seconds, OFF-12-390 seconds Dual function fan delay timer, Controls the circulating fan in heat pump, A/C and forced air systems, OFF delay controls fan relay to purge ducts of residual air at the end of the heating/cooling cycle, ON delay allows air to reach the proper comfort level prior to energizing the fan, Specifications:, Output:, 1 amp maximum, 40mA minimum, 10 amp inrush 800442000695
Weight: 0.5, Dimensions: 4.5” x 3” x 1.75”, Width: 3.25, Height: 1.75, Length: 4.75, Modulation: 70°-100°F Integral heat pump bypass circuitry allows electonic bypass of speed control, Eliminates overshoots common to on/off and pressure switch controls, Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions, Features: hard start, low temperature bypass, isolated 24 VAC supply, RoHS compliant / lead free design, Controls up to 3 refrigeration circuits, Typical application: A/C and heat pumps, Specifications:, Input:, 50/60 Hz 1.8 VA max., Line input: 120-480 VAC, Output:, Maximum: 10 amps, Minimum: 100 mA
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 190-630 VAC, Weight: 0.8, Dimensions: 6.5” x 4.25” x 1.5”, Width: 4.25, Height: 1.5, Length: 6.5, Frequency: 50/60 Hz, Control Voltage: 18-240 VAC, Delay on Break Timer: 0.1-5 minutes, Voltage Unbalance: Adjustable: 2-25% Lower cost, full performance version featuring bright LED indicators to display system faults, Monitors front and back sides of system, Universal voltage operation: 190-630 VAC, Knob-adjustable features and system set points, Reset mode: choice of auto or manual (lockout), Protects against voltage unbalance, high/low voltage, phase loss, reversal, faulty power, incorrect sequencing and rapid short cycling, Built-in anti-short cycle protection, Specifications:, Output:, Relay, SPDT, N.O.: 10 amps, N.C.: 6 amps 800442000138
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 190-630 VAC, Weight: 0.8, Dimensions: 6.5” x 4.25” x 1.4”, Width: 4.25, Height: 1.5, Length: 6.5, Operating Temperature: -40ºC to +75ºC (-40ºF to +167ºF), Frequency: 50/60 Hz, Control Voltage: 18-240 VAC (optional), Delay on Break Timer: 0-10 minutes, Voltage Unbalance: Adjustable: 2-25% Fully programmable with LCD diagnostic display, Easy to configure - simple push button setup, Identifies front and back side faults, Reset mode: choice of auto or manual, Protects against: voltage unbalance, high/low voltage, phase loss, reversal, faulty power, incorrect sequencing and rapid short cycling, Reliable, high temperature LCD to 167, Simultaneous voltage display, no scrolling, Line voltage programmable, Universal voltage operation: 190-630 VAC, Specifications:, Output:, Relay, SPDT, N.O.: 10 amps,, N.C.: 6 amps 800442000206
Warranty: Limited Lifetime Protection Guarantee 800442029542
Warranty: 3 years from MFR date; 1 year from install date., Weight: 0.55, Width: 5.75, Height: 1.5, Length: 7.5, Voltage Range: Line (98-132 VAC) @ 60Hz, Gas Valve: 1A, 24 VAC, Heat: 5A, 1/2 HP, 250 VAC, Ignitor: 5A, 120 VAC, Inducer Blower: 4A, 120 VAC, Cool Blower: 10A, 2HP, 240 VAC, Humidifier Motor: 0.5A, 24 VAC, Electronic Air Cleaner: 1A, 120 VAC Microprocessor-based precision, Monitors pressure, roll-out and limit switches, Controls gas valve, inducer draft motor, circulating blower and hot surface ignitor., Reverse polarity detection, Twinning compatible with another ICM288 board, Diagnostic LEDs to aid in testing/troubleshooting 800442028095
Voltage: 18 to 30 VAC, Weight: 0.1, Width: 3.5, Height: 1, Length: 2.875, Power Consumption: 1 watt maximum, Frequency: 50/60 Hz, Defrost Time: Fixed 10 minutes, Interval Time Between Defrosts: Pin-selectable 30/60/90 min ICM300 is a replacement for OEM type 621 controls, Low cost, time and temperature defrost, HOLD input tracks compressor run times, Time and temperature terminate, Test pins reduce test time by 256X, Stable pin post construction, Time and temperature terminate ,10-minute fixed defrost time,, Pin-selectable intervals: 30/60/90 minutes, Specifications:, Output:, Relay, SPST, N.O.: 1 amp, Defrost Time:, Fixed 10 minutes, Interval Time Between Defrosts:, Pin-selectable 30/60/90 min
ICM2801_zm.jpg York Replacement Furnace Control Board
Locke Part #: L4917MFG Part #: ICM2801
Warranty: 3 years from MFR date; 1 year from install date., Weight: 0.4, Width: 5.75, Height: 1.75, Length: 4.25, Voltage Range: Line (98-132 VAC) @ 60Hz, Gas Valve: 1A, 24 VAC, Heat: 5A, 1/2 HP, 250 VAC, Ignitor: 5A, 120 VAC, Inducer Blower: 4A, 120 VAC, Cool Blower: 10A, 2 HP, 240 VAC Controls vent motor, blower control, hot surface ignitor and gas valve, Monitors timing, trial for ignition, flame sensing and lockout, Microprocessor-based, Reverse polarity protection, 100% lockout safety feature, Compatible with LP or Natural Gas, Twinning compatible with another ICM2801 control, Status LED for fault codes to aid in troubleshooting 800442013879
Warranty: 3 years from MFR date; 1 year from install date., Vibration: 13.8Hz @ 0.2 Gs for one hour in each orthogonal axis, Voltage Range: Line (98-132 VAC) @ 60Hz, Humidity: 5% to 95% R.H. (non-condensing) @ +55ºF, Storage: -40ºF to 185ºF, Heat: 10A, 240 VAC, Cool Blower: 20A, 2 HP, 240 VAC, Operating: -40ºF to 176ºF, Inducer Motor: 4A FLA, 8A LRA @ 120 VAC Hot Surface Ignition (HSI) control board, Microprocessor-based, 100% lockout safety feature, Controls vent motor and blower control, Monitors limit switch, pressure switch and gas valve, Compatible with LP or Natural Gas, Status LED for fault codes to aid in troubleshooting, Timing, Inducer Pre-Purge Time:, 1 second, Heat Blower On Delay:, 45 seconds, Heat Blower Off Delays:, 120 or 180, Cool Blower On Delay:, 1 seconds, Cool Blower Off Delay:, 1 seconds 800442013985
Warranty: 3 years from MFR date; 1 year from install date., Weight: 0.4, Width: 6, Height: 1.5, Length: 4.5, Voltage Range: Line (98- 132 VAC) @ 60Hz, Gas Valve: 1A, 24 VAC, Heat: 5A, 1/2 HP, 250 VAC, Ignitor: 5A, 120 VAC, Inducer Blower: 4A, 120 VAC, Cool Blower: 10A, 2HP, 240 VAC, Humidifier Motor: 0.5A, 24 VAC, Electronic Air Cleaner: 1A, 120 VA Low cost form, fit and functional OEM replacement control board for Nordyne: 903106-Kit, Controls gas valve, inducer draft motor, circulating blower and hot surface ignitor, Monitors timing, trial for ignition, flame sensing, lockout, plus pressure, rollout and limit switches, Twinning compatible with another ICM2805A furnace control, Microprocessor-based precision, Diagnostic LEDs aid in testing and troubleshooting 800442013992
Warranty: 3 years from MFR date; 1 year from install date., Voltage Range: Line (98-132 VAC) @ 60 Hz, Heat: 20A @ 120 VAC, Inducer Motor: 5A @ 120 VAC, Cool: 20A @ 120 VAC Controls inducer fan motor, blower fan and monitors limit switches, Microprocessor based design, Functions with all 24 VAC thermostats, Timing, Cool blower On Delay:, 1 second,, Cool blower Off Delay:, 1 second, Heat blower On Delay:, 45 seconds, Heat blower Off Delay: 90, 150, 210, 270 sec. 800442013312
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 180V, Weight: 0.4, Width: 2.5, Height: 5.75, Length: 2, HP: 1/3 - 1/2, Operating Voltage: 120V, Current: 12A, Retry Time: Within 90 seconds For single-phase commercial and domestic capillary refrigeration systems and freezers, For 1/3 to 1/2 HP motors, Pre-wired for fast installation, Overload: 30A,243-292 mfd 800442014401
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 180V, Weight: 0.35, Width: 2.5, Height: 5.75, Length: 2, HP: 1/4 - 1/3, Operating Voltage: 120V, Current: 12A, Retry Time: Within 90 seconds For single-phase commercial and domestic capillary refrigeration systems and freezers, For 1/4 to 1/3 HP motors, Pre-wired for fast installation, Overload: 22A, 243-292 mfd 800442014395
Warranty: 3 years from MFR date; 1 year from install date., Weight: 0.35, Width: 2.5, Height: 5.25, Length: 2, HP: 1/12 - 1/5, Operating Voltage: 120V, Retry Time: Within 90 seconds, Maximum Voltage: 180V, Maximum Current: 12A For single-phase commercial and domestic capillary refrigeration systems and freezers, For 1/12 to 1/5 HP motors, Pre-wired for fast installation, Overload: 12A, 145-175 mfd 800442014388
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 18 to 30 VAC, Weight: 0.1, Width: 3.5, Height: 1, Length: 2.875, Frequency: 50/60 Hz, Defrost Time: Fixed 10 minutes, Interval Time Between Defrosts: Pin-selectable 30/60/90 min Low cost, time and temperature defrost, Sensor input for defrost terminate, Time and temperature terminate, 10-minute fixed defrost time, Pin-selectable intervals: 30/60/90 minutes, Test pins reduce test time by 256x, HOLD input accumulates actual compressor run times, Specifications:, Output:, Type:, Relay, SPST, N.O.:, 1 amp, Defrost time:, 10-minute fixed, Interval times:, Pin-Sel. 30/60/90 min., Replaces:, Goettl:, 305007, ICM:, DFOSP24A2, Rheem:, 47-21776-06 800442000039
ICM303_zm.jpg York Replacement Defrost Control Board
Locke Part #: L4941MFG Part #: ICM303C
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 18 to 30 VAC, Weight: 0.1, Width: 3.5, Height: 1, Length: 2.875, Frequency: 50/60 Hz, Defrost Time: Fixed 10 minutes, Interval Time Between Defrosts: Pin-selectable 30/60/90 min, Strip Heat / Reversing Valve Outputs: 24 VAC, 2 amps, Relay Output: 1 HP fan @ 240 VAC Time and temperature terminate, Integral short cycle protection, Pin-selectable intervals: 30/60/90 minutes, High/low pressure switch monitoring, High power, condenser relay output, Strip heat, reversing valve outputs 800442000053
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 18-30 VAC, Weight: 0.2, Width: 3.5, Height: 1.32, Length: 5.5, Frequency: 50/60 Hz, Defrost Time: Fixed 10 minutes, Interval Time Between Defrosts: Pin-selectable 30/50/90 min Low cost, time and temperature defrost, Time and temperature terminate, 10-minute fixed defrost time, Pin-selectable intervals: 30/50/90 minutes, Test pins reduce test time by 256x, High power output, outdoor fan (1/2 HP fan @ 240 VAC), Strip heat, reversing valve outputs (24 VAC, 1 amp), Integral short cycle protection, Specifications:, Form: SPDT, Anti-short cycle time: 5 minutes, Outdoor fan relay output:, N.O.: 20 amps, N.C.: 10 amps 800442000107
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 18-30 VAC, Weight: 0.2, Width: 3.5, Height: 1.32, Length: 5.5, Frequency: 50/60 Hz, Defrost Time: Fixed 10 minutes, Interval Time Between Defrosts: Pin-selectable 30/50/90 min Low cost, time and temperature defrost, Time and temperature terminate, 10-minute fixed defrost time, Pin-selectable intervals: 30/50/90 minutes, Test pins reduce test time by 256x, High power output, outdoor fan (1/2 HP fan @ 240 VAC), Strip heat, reversing valve outputs (24 VAC, 1 amp), Specifications:, Outdoor fan relay output:, N.O.: 20 amps, N.C.: 10 amps 800442000114
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 18-30 VAC, Weight: 0.3, Width: 5.25, Height: 1.25, Length: 4.5 Dual function fan delay timer, Controls the circulating fan in heat pump, A/C and forced air systems, OFF delay purges ducts of residual air, ON delay allows air to reach the proper comfort level prior to energizing the fa, Specifications:, Output:, Heat/Cool Speed, N.O.: 20 amps @ 240 VAC, N.C.: 10 amps @ 240 VAC, Time delays:, Blower ON delay:, 30 seconds, Blower OFF Delay:, 90, 120, 150, 180 seconds (adjustable) 800442000015
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 18-30 VAC, Weight: 0.45, Width: 5, Height: 1, Length: 5.25 Reliable solid state fan blower control, Specifically designed to replace popular gas furnace centers, Pin selectable blower delays, High power, relay output, Dual function fan delay timer, Controls the circulating fan in HP, A/C and forced air systems, OFF delay purges ducts of residual air, ON delay allows air to reach the proper comfort level prior to energizing the fan, Specifications:, Contact ratings:, N.O.:, 20 amps, N.C.: 10 amps, Time delays:, Heat ON delay:, 75 seconds, Heat OFF delay:, 105 seconds, Cool OFF delay:, 90 seconds 800442000022
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 18-30 VAC, Weight: 0.3, Width: 8, Height: 1.625, Length: 3.75 Cooling control module with fan delay, Integral low voltage terminal board with field thermostat wiring, Electronic air cleaner output, DC output for fan relays and 1st stage of electric heater control, High power, relay output, Interlock circuitry prevents 2nd & 3rd stage electric heat energization without proper fan operation, Specifications:, Contact Ratings:, N.O: 20 amps, N.C.: 10 amps, Blower OFF delay: 60 seconds 800442000725
Warranty: 3 years from MFR date; 1 year from install date., Voltage: 18-30 VAC, Weight: 0.45, Width: 5.5, Height: 0.875, Length: 5.5 Heavy duty heat relay, Purges ducts of residual air, Integral short cycle protection, Specifications:, Contact Ratings:, 20 amps @ 240 VAC on high, 10 amps @ 240 VAC on low, Time Delays:, Heat ON: 60 seconds fixed, Heat OFF: 60-240 seconds adjustable, Cool OFF: 90 seconds fixed, Replaces:, Carrier:, CES0110019,, HH84AA001, HH84AA003, HH84AA005, HH84AA009, HH84AA014, HH84AA015, HH84AA021, Robertshaw:, 695-101 800442000756
Warranty: 3 years from MFR date; 1 year from install date., Weight: 0.6, Width: 8.5, Height: 0.75, Length: 7.625, Voltage Range: Line (98-132 VAC) @ 60 Hz, Gas Valve: 1.5A @ 30 VAC, Heat: 5A, 1/2 HP, 240 VAC, Ignitor: 5A @ 120 VAC, Inducer Blower: 4A, FLA-8.0 LRA @ 120 VAC, Cool Blower: 30A, 2 HP, 240 VAC Control gas valve, ignitor, blower motor, inducer, humidifier and air cleaner, Microprocessor-based, Designed for 100% gas shutoff in case of ignition failure, Model selection of 80+ and 90+ furnace operation, Secondary brownout voltage protection, Heating and cooling fan functions in response to standard thermostat, Reverse polarity protection, Provides diagnostic LEDs to aid in troubleshooting, Twinning compatible with another ICM281 board 800442002811
Weight: 0.6, Width: 6.625, Height: 2.5, Length: 5.75, Operating Temperature: -40°C (-40°F) to 75°C (176°F), Power Consumption: 0.3A plus gas valve current at 24 VAC, Line Voltage: 115 VAC, 60Hz, Control Voltage: 24 VAC (18-30 VAC), 60Hz Direct Spark Ignition (DSI) control board, Microprocessor-based, 100% lockout safety feature, Controls Induced Draft and indoor blower motors, Humidifier output, spark ignitor and gas valve, Monitors timing, trial for ignition, Flame sensing and lockout,, Compatible with LP or Natural Gas, Status LEDs for fault codes to aid in troubleshooting, Specifications:, Timing, Pre-purge:, 30 seconds, Trial for ignition:, 7 seconds, Retries:, 2 groups of 2, 30 seconds delay within the, group and 3 minutes delay between groups, Lockout:, 1 hour, Post-purge:, 90, 120, 160 and 180 seconds, Inputs:, Power: 24 VAC and COM, Thermostat Interface: R,W, Y, and G, System Switches: Vent pressure and limit switches (main and over-temperature switches in series), Flame Sensing, Heat Blower OFF Delay (miniature slide switch set), Outputs:, Spark, Gas Valve: GV, Inducer Draft Motor: IDM, Blower Motor: FAN ,, COOL and HEAT speeds, Electric air Cleaner: EAC, Humidifier Relay: HUM, Heat/Cool Relay: H/C, LED Indicators:, Power, Green LED: PWR, Status, Green LED: OK, Flame Status, Yellow LED: FLAME
Warranty: 3 years from MFR date; 1 year from install date., Weight: 0.55, Width: 5.75, Height: 1, Length: 4.75, Voltage Range: Line (98-132 VAC) @ 60 Hz, Fan: 2 HP @ 240 VAC, Gas Valve: 1A @ 24 VAC, Ignitor: 5A @ 120 VAC, Inducer Motor: 7A @ 250 VAC Microprocessor-based fan blower, Inducer fan outputs, Hot surface ignitor output, Flame sensor input, Gas valve output, Status LED for fault codes, Twinning compatible with another ICM280 board 800442009223
Warranty: 3 years from MFR date; 1 year from install date., Weight: 0.55, Width: 8, Height: 1.5, Length: 5, Operating Temperature: -40°C to 75°C (-40°F to 176°F), Voltage Range: Line (98-132 VAC) @ 60 Hz, Gas Valve: 1.5A @ 30 VAC, Heat: 5A, 1/2 HP, 240 VAC, Ignitor: 5A @ 120 VAC, Inducer Blower: 4A, FLA-8.0 LRA @ 120 VAC, Cool Blower: 30A, 2HP, 240 VAC Low cost replacement for Carrier HK42FZ004/007/008/009/011/013/016/034, Controls gas valve, ignitor, blower motor, inducer, humidifier and air cleaner, Microprocessor-based precision, Software for enhanced controls operation in counterflow and downflow furnace applications, Designed for 100% gas shutoff in case of ignition failure, Twinning compatible with another ICM282A board, Reverse polarity protection, Secondary brownout voltage protection, Compatible with 24 VAC standard thermostat, Diagnostic fault codes/LED to aid in troubleshooting 800442002828
Warranty: 3 years from MFR date; 1 year from install date., Weight: 0.5, Length: 5, Width (in): 7, Height (in): 1.875, Line Voltage: 208/230 VAC, 60Hz, Lockout Timing: Manual reset, Control Voltage: 24 VAC (18-30 VAC), 60Hz , Post-Purge Timing: 45 seconds, Pre-Purge Timing: 45 seconds, Retry Period Timing: Every 20 seconds for 15 minutes, Trial for Ignition Timing: 5+2 seconds Low cost form, fit and functional replacement for Carrier: LH33WP003A, Direct Spark Ignition (DSI) control board, Microprocessor-based, Controls combustion, blower and indoor fan motors; spark ignitor; and the gas valve, Monitors timing, trial for ignition, flame sensing and lockout, 100% lockout safety feature, Compatible with LP or Natural Gas, Status LED for fault, LED Indicators, - Red LED: Steady ON-normal operation, Flashing-fault codes Inputs:, Power - RT and C, Thermostat Interface - R,W, and G, Safety Switches - RS, LS, and CS, Combustion Motor Hall Effect Sensor, Flame Sensing Outputs:, Spark - Gas Valve - GV, Combustion Motor - CM, Blower Motor - BM, Indoor Fan Motor - IFO 800442011844