Loading ...

Loading ...

Search in: ICOR INTERNATIONAL INC

nub.jpg NU-22B (25lb cylinder)
Locke Part #: L1243MFG Part #: R422B
Warranty: 18 months from date code if seal is not broken, Color: Colorless, Type: 55% R-125, 42% R-134a, 3% R-600a, Odor: Slightly Ethereal, pH: Neutral, Physical State: Gas at Ambient Temperature, Solubility In Water: Not Determined, Boiling Point (DEW @ 1 ATM): -32.15° F, Boiling Point (Bubble @ 1 ATM): -40.86° F, MolecularWeight: 108.53 G/MOL, Density (Liquid @ 1 ATM): 87.25 LB/FT3, Density (VAPOR @ 1 ATM): 0.3633 LB/FT3, Vapor Pressure @ 68 Deg F: 116.0 PSIA, Vapor Pressure @ 140 Deg F: 328.0 PSIA, Volatiles (% ): 100, Package Size: 25 lb cylinder, Global Warming Potential: 2500, Oil Compatibility: All, Molar Mass (Ibm/Ibmol): 108.52, Critical Pressure (Psia): 574.07, Critical Temperature (°F): 181.79, Critical Density (Ibm/ft3): 32.86, Liquid Density (70°F, Ibm/ft3): 73.053, Temperature Glide (NBP): 10, Pounds Per Gallon (70 °F): 9.76, Maximum High Boiling Impurities (% vol): 0.01, Recommended Maximum Exposure Limits in Air (ppm): 1000, Evaporator Temperature Range: 0° F to 50° F, R-125 (% Weight): 55 EPA SNAP listed R-22 replacement., ASHRAE designated R-422B., Has the ASHRAE safety classification, A1 (nontoxic/nonflammable)., Can be used in MO, AB and POE designed systems. No unnecessary oil change is required., Greater capacity than its predecessor, R-417A., Its operating pressures are closer to R-22 than any other R-22 replacement on the market today., Successfully used in system applications ranging from residential to industrial., Available through wholesale distributors from coast to coast., 15-20% less expensive than its predecessor., Available in 25 lb. disposable cylinders and bulk refillable cylinders., Produced in the USA and packaged in American made cylinders., Non-ozone depleting, Non-toxic., No line set changes., Can be tapped off after leak has been repaired., Enable continued use of existing equipment., Can use R-22 TEV and power element., Widespread availability., Replaces R-22, R-407C, R-417A, R-421A, R-422D, R-424A, R-427A, R-434A, R-438A. 834674000000
hs2.jpg HOT SHOT-2 25 lb cylinder
Locke Part #: L1244MFG Part #: HS2-25
Warranty: 18 months from date code if seal is not broken, Color: Colorless, Type: 19.5% R-125, 78.8% R-134a, 1.7% R-600, Odor: Slightly Ethereal, pH: Neutral, Physical State: Gas at Ambient Temperature, Solubility In Water: Not Determined, Boiling Point (DEW @ 1 ATM): -20.5° F, Boiling Point (Bubble @ 1 ATM): -26.7° F, MolecularWeight: 103.7 G/MOL, Density (Liquid @ 1 ATM): 85.91 LB/FT3, Density (VAPOR @ 1 ATM): 0.3374 LB/FT3, Vapor Pressure @ 68 Deg F: 96.7 PSIA, Vapor Pressure @ 140 Deg F: 238.1 PSIA, Volatiles (% ): 100, Package Size: 25 lb cylinder, Global Warming Potential: 1820, Oil Compatibility: All, Molar Mass (Ibm/Ibmol): 103.73, Critical Pressure (Psia): 590.85, Critical Temperature (°F): 203.7, Critical Density (Ibm/ft3): 32.12, Liquid Density (70°F, Ibm/ft3): 74.6, Temperature Glide (NBP): 6, Pounds Per Gallon (70 °F): 9.97, Maximum High Boiling Impurities (% vol): 0.01, Recommended Maximum Exposure Limits in Air (ppm): 1000, Evaporator Temperature Range: -15° F to 50° F, R-125 (% Weight): 19.5 Zero Ozone Depletion Potential, Non Toxic and Non Flammable, HFC - Ozone Safe, Compatible with all compressor oils, Can be topped off after leak has been repaired, Widespread availability, No oil change to AB or POE, ASHRAE Designated R-417C, No TEV or cap tube replacement, Replaces R-12, R-134a, R-500, R-401A/B, R-409A, R-414B, R-416A, R-420A, R-426A, R-437 & R-414A in most applications., EPA SNAP Listed - Stationary Equipment Only, R-12 and 134a low, medium and high temp refrigeration, R-12 and 500 air conditioning 834674000000
os.jpg ONE SHOT-C 24 # cylinder
Locke Part #: L1302MFG Part #: OS-24
Warranty: 18 months from date code if seal is not broken, Color: Colorless, Type: 82% R-125, 15% R-134a, 3% R-600a, Odor: Slightly Ethereal, pH: Neutral, Physical State: Gas at Ambient Temperature, Solubility In Water: Not Determined, Boiling Point (DEW @ 1 ATM): -45.1° F, Boiling Point (Bubble @ 1 ATM): -50.7° F, MolecularWeight: 113.49 G/MOL, Density (Liquid @ 1 ATM): 89.20 LB/FT3, Density (VAPOR @ 1 ATM): 0.3912 LB/FT3, Vapor Pressure @ 68 Deg F: 155.6 PSIA, Vapor Pressure @ 140 Deg F: 360.1 PSIA, Volatiles (% ): 100, Package Size: 24 lb cylinder, Global Warming Potential: 3100, Oil Compatibility: All, Molar Mass (Ibm/Ibmol): 113.4, Critical Pressure (Psia): 547.70, Critical Temperature (°F): 163.53, Critical Density (Ibm/ft3): 33.739, Liquid Density (70°F, Ibm/ft3): 72.663, Temperature Glide (NBP): 5, Pounds Per Gallon (70 °F): 9.71, Maximum High Boiling Impurities (% vol): 0.01, Recommended Maximum Exposure Limits in Air (ppm): 1000, Evaporator Temperature Range: -40° F to 30° F, R-125 (% Weight): 82 ASHRAE R-422C, Higher Capacity & COP than R-404A & R507A, 20% Lower Global Warming Potential Compatible with MO, AB, and Poe Based Oils, Zero Ozone Depletion Potential, Non Toxic and Nonflammable, Suitable For New and Existing Equipment Can Be Topped Off Repeatedly, HFC Leak Detectors Suitable For Use with One Shot (C), Replaces R-402A, R-402B, R-404A, R-408A, R-502, and R-507A. Also replaces R-22 for low-temperature and medium-temperature applications., Can use R-502/404A TEV and power element., Can be tapped off after leak has been repaired., 20% lower GWP vs. 404A and 507A, Significantly lower energy usage vs. 22 in med and low temp refrigeration. 834674000000
Color: Clear, Odor: Slightly Ethereal, Vapor Pressure: 12 psi @ 66° F/19° C, Physical State: Liquid, Solubility In Water: Slightly soluble, Package Size: 5 lb cylinder, Volatility Description: Volatile, Flammability: Not flammable Ozone safe, Non-Toxic, Non-Flammable, User friendly, Pre-conversion preparation and system burnouts, Cleans any ACR System Lines, Convenient 5 and 10 lb cylinders, Includes Free Handy Shot Flushing Tool 834674000048
HSCTA.jpg Tank Adapter for R-134a Refrigerant
Locke Part #: T0539MFG Part #: HSCTA