1/0 AWG, Stranded, Black THHN Wire, 500' Reel

by: Encore Wire

Locke# P0780 | Mfg# 118101801440
P0780

1/0 AWG, Stranded, Black THHN Wire, 500' Reel

by: Encore Wire

Locke# P0780 | Mfg# 118101801440

For pricing and availability please Sign In

*Item only available: AR, KS, MO, OK, TX, VA

  • Product Featuresarrow_drop_down
    • A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling.
    • SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL.
    • All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring.
    • For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified.
    • 6 AWG and larger Sunlight Resistant in all colors.
    • 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test.
    • Construction:
    • Conductors:
    • Solid, uncoated copper conductors per ASTM-B3
    • Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8
    • Insulation:
    • Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83
    • Applications:
    • Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC).
    • Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications.
    • For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants.
    • For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants.
    • Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations.
    • Jacket:
    • A tough, polyamide, Nylon outer covering per UL-1063 and UL-83.
    • Standards:
    • Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321
    • ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544
    • Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658
    • UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger)
    • ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant