black.jpg

Loading ...

1/0 AWG, Stranded, Black THHN Wire, 500' Reel

Details

  • Locke Part #: P0780
  • Mfg. Part #: 118101801440
  • Manufacturer: Encore Wire

For pricing information and availability, login to your account with your customer number and home branch. Or contact your local branch.

  • A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling.
  • SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL.
  • All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring.
  • For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified.
  • 6 AWG and larger Sunlight Resistant in all colors.
  • 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test.
  • Construction:
  • Conductors:
  • Solid, uncoated copper conductors per ASTM-B3
  • Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8
  • Insulation:
  • Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83
  • Applications:
  • Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC).
  • Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications.
  • For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants.
  • For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants.
  • Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations.
  • Jacket:
  • A tough, polyamide, Nylon outer covering per UL-1063 and UL-83.
  • Standards:
  • Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321
  • ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544
  • Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658
  • UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger)
  • ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant