MA23-N.jpg

Loading ...

40 Amp Surge Meter Generator Connector

Details

For pricing information and availability, login to your account with your customer number and home branch. Or contact your local branch.

  • GenerLink eliminates the use of extension cords and other connections that can be hazardous to customers and utility personnel.
  • GenerLink detects when a generator is operating and automatically disconnects from the utility grid, eliminating dangerous backfeed.
  • GenerLink is equipped with GenerLok, a unique interlocking power cord system that provides a quick and easy connection of a portable generator.
  • GenerLink is installed in 20 minutes or less by utility personnel and does not require the customer s presence.
  • GenerLink is easily installed behind a customer s electric meter and requires no rewiring of the customer s electrical system.
  • With GenerLink, customers have the flexibility to run virtually any appliance, up to the capacity of their generator by simply energizing appliances from their breaker panel.
  • Specifications:
  • Generator Input
  • Generator Input Voltage > 200 Volts
  • Protection
  • Supplemental Overcurrent < 40 A
  • Utility Input
  • Utility Input Voltage > 180 Volts
  • Protection
  • Over-Temperature Trip > 105 C
  • Load
  • Integrated Whole-House
  • Protection
  • Surge Protection Model MA23/24 - S Only
  • Electrical:
  • Withstand Current
  • 10,000 Amperes rms symmetrical at .7 - .8 pf, 240 Volts, 60 Hz
  • 6000 Amperes for 6 cycles at .7 - .8 pf, 240Volts, 60 Hz
  • Connection
  • Proprietary GenerLoc QuickConnect Cord