B210957.jpg

Loading ...

Robertshaw 780-845 Intermittent Ignition Control, For Use With Residential and Commercial Heating Equipment, 24 VAC, 50/60 Hz, 1.5 A

Details

For pricing information and availability, please login to your account, or contact a local branch.

  • The Robertshaw 780-845 lockout ignition control provides 90 sec of spark, followed by a six minute time delay (purge) between ignition attempts
  • If the pilot flame is not sensed after three tries, the control goes into a one-hour lockout period
  • At the end of the lockout period, if the demand for heat is still present, the unit will repeat the three tries for ignition
  • Reduces truck stock inventory, saving space and money
  • Easy-to-install with complete in-depth installation instructions
  • Pilot and main valves draw 1 A at 0.5 power factory
  • Combined load at 1.5 A at 0.4 power factory
  • 95 percentage relative humidity non-condensing at 104 deg F
  • -40 to 175 deg F temperature
  • 2 sec flame failures re-ignition time
  • 90 sec safety lockout
  • 0.7 a thermostat anticipator setting
  • 0.7 mA DC at 25 deg C flame sensor current
  • 24 VAC 20 VA transformer
  • Country of Origin: MX
  • Domestic/Import: Import
  • Mfg Standards/Approvals: cCSAus Certified
  • Series: 780
  • Specifications: 24 VAC, 50/60 Hz, 1.5 A
  • Suitable For Use With: Residential and Commercial Heating Equipment
  • Type: Intermittent


Feedback