10 Ton 3PH 208/230V Electric Packaged Units

Details

For pricing information and availability please contact your local branch.

  • Approvals
  • ETL and CSA listed, Efficiency rating verified by GAMA
  • Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National Electrical Codes.
  • All models are certified in accordance with the ULE certification program, which is based on AHRI Standard 340/360- 2007.
  • All models are ASHRAE 90.1-2007 compliant.
  • ISO 9001 Registered Manufacturing Quality System.
  • Heating System
  • Optional Factory or Field Installed, Helix wound nichrome elements
  • Individual element limit controls, Wiring harness
  • Unit fuse block is furnished as standard
  • Cooling System
  • Designed to maximize sensible and latent cooling performance at design conditions.
  • System can operate from 30 F to 125 F without any additional controls.
  • R-410A Refrigerant is Non-chlorine based, ozone friendly.
  • Scroll compressors on all models for high performance, reliability and quiet operation.
  • Resiliently mounted on rubber grommets for quiet operation.
  • Thermal Expansion Valves Assures optimal performance throughout the application range.
  • High Pressure Switch Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation.
  • Freezestats Protect the evaporator coil from damaging ice build-up due to conditions such as low/no airflow, or low refrigerant charge.
  • Copper tube Coil construction, enhanced rippled edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer. Factory leak tested.
  • Evaporator Coil Cross row circuiting with rifled copper tubing optimizes both sensible and latent cooling capacity.
  • Single formed Condenser coil.
  • Plastic Condensate Drain Pan, sloped to meet drainage requirements of ASHRAE 62.1.
  • Side or bottom drain connections.
  • Reversible to allow connection at back of unit.
  • Outdoor Coil Fan Motors Thermal overload protected, totally enclosed, permanently lubricated ball bearings, shaft up, wire basket mount.
  • Outdoor Coil Fans PVC coated fan guard furnished.
  • Cabinet
  • Heavy-gauge steel panels and full perimeter heavy-gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation.
  • Base rails have rigging holes.
  • Three sides of the base rail have forklift slots.
  • Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building.
  • Units are shipped in downflow (vertical) configuration, can be field converted to horizontal airflow with optional Horizontal Discharge Kit.
  • All panels adjacent to conditioned air are fully insulated with nonhygroscopic fiberglass insulation.
  • Unit base is fully insulated. The insulation also serves as an air seal to the roof curb, eliminating the need to add a seal during installation.
  • Outdoor Coil Fins per inch: 20
  • Outdoor Coil Net Face Area Sq. Ft.: 28
  • Outdoor Coil Number of Rows: 2
  • Outdoor Coil Tube Diameter in.: 3/8
  • Outdoor Fans Diameter in.- No. of Blades: (2) 24
  • Outdoor Fans Motor Horsepower: (2) 1/3hp
  • Outdoor Fans Motor rpm: 1075
  • Outdoor Fans Total Air Volume - CFM: 7800
  • Outdoor Fans Total Motor watts: 670
  • Phase: 3
  • Tonnage: 10
  • Volt: 208/230
  • Allied Air
  • K Series Package Units