Products | L4977, ICM Controls

ICM ICM292A Gas Ignition Control Board, 5-3/4 in Length, 6-5/8 in Width, 115 VAC Input, 24 VAC

by: ICM Controls

Locke# L4977 | Mfg# ICM292A | UPC# 800442013329
L4977

ICM ICM292A Gas Ignition Control Board, 5-3/4 in Length, 6-5/8 in Width, 115 VAC Input, 24 VAC

by: ICM Controls

Locke# L4977 | Mfg# ICM292A | UPC# 800442013329

For pricing and availability please Sign In

*Item only available: AR, KS, MO, OK, TX, VA

  • Product Featuresarrow_drop_down
    • Replacement for Rheem 62-24140-04 control boards
    • Direct Spark Ignition (DSI) control board
    • Microprocessor based
    • Controls inducer motors, air cleaner (if equipped), humidifier (if equipped), spark ignitor and the gas valve
    • Monitors timing, trial for ignition, system switches, flame sensing and lockout
    • 100% lockout safety feature
    • Compatible with LP or natural gas
    • LED indication for status and fault codes to aid in troubleshooting
    • 2-1/2 in H
    • Timing: Pre-purge - 30 sec, trial for ignition - 7 sec, retries - two groups of two, 30 sec delay within the group and 3 min delay between groups, lockout - 1 hr, post-purge - 90, 120, 160 and 180 sec
    • Inputs: Power - 24 VAC and COM, thermostat interface - R,W, Y, and G, system switches - vent pressure and limit switches (main and over-temperature switches in series), flame sensing, heat blower OFF delay (miniature slide switch set)
    • Output: Heat/cool speed, NO - 20 A at 240 VAC, NC - 10 A at 240 VAC
    • LED Indicators: Power, Green LED: PWR/ Status, Green LED: OK/ Flame status, Yellow LED: FLAME
    • Patents - No 6222719: Ignition boost, No 5917691: fail safe relay driver
  • Specificationsarrow_drop_down
    • Control Voltage: 24 VAC
    • Country of Origin: US
    • Domestic/Import: Domestic
    • Input Voltage: 115 VAC
    • Length: 5-3/4 in
    • Package Weight: 0.6 lb
    • Width: 6-5/8 in
  • Resourcesarrow_drop_down