Search in: Aluminum Category

Standard Packaging: 5000' Reel, Approximate Net Weight (lbs/1000 ft): 90, Number of Strands: 7, Allowable Ampacity (Amps) 60°C / 75°C / 90°C: - / 90 / 100, Size (AWG or KCMIL): 2, Approximate Overall Dimensions (in): 0.388, Compact Diameter of Aluminum Conductor (in): 0.268, XLPE Insulation Thickness (in): 0.060 Application:, Construction:, Conductors Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation Cross-linked polyethylene (XLPE) per UL-854. Sunlight-resistant in all colors 6 AWG and larger, Standards: Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 436, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 1/0-1/0-1/0, Allowable Ampacities for Direct Burial: 219, Code Name: Bergen, Finished Cable - Outside Diameter (in): 1.111, Neutral Conductor - No of Strands: 10, Neutral Conductor - Outside Diameter (in): 0.496, Neutral Conductor - Size (AWG): 1/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 10, Phase Conductors - Outside Diameter (in): 0.496, Phase Conductors - Size (AWG): 1/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 430, Standard Packaging (ft): 1200’, Conductor Sizes (AWG): 1/0-1/0-1/0, Code Name: Neritina, Phase Conductors - No of Strands: 10, Phase Conductors - Outside Diameter (in): 0.456, Phase Conductors - Size (AWG): 1/0, Phase Conductors - XLPE Thickness (in): 0.060, Bare Neutral Conductor - Finished OD (in): 0.398, Bare Neutral Conductor - No of Strands: 6+1, Bare Neutral Conductor - Rated Strength (lbs): 4380, Bare Neutral Conductor - Size (AWG): 1/0, Bare Neutral Conductor-Type: ACSR, Ampacity (XLPE): 200, Diameter of Final Construction (in): 0.980 Triplex overhead service drop cable has two black XLPE insulated aluminum conductors cabled around a bare-stranded ACSR 1350 Series alloy supporting neutral with steel support center wire., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation rated 90 C operation wet or dry., Manufactured and tested according to ANSI/ICEA S-76-474., Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts., Insulated conductors are surface printed for identification., Construction:, Conductors:, Insulated Conductor, : Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836., Neutral Conductor, : Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232., Insulation:, Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 C wet or dry., Applications:, Triplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90 C wet or dry., Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure., Suitable for 120-volt aerial service for outdoor lighting or for temporary service at construction sites., Standards:, ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232; ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 546, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 100, Allowable Ampacities (amps) @ 75°C: 120, Allowable Ampacities (amps) @ 90°C: 135, Nominal Diameter (in): 1.150, Allowable Ampacities (amps) @ **Dwelling: 125, Ground/Neutral - Sizes (AWG): 2, Ground/Neutral - Style/Ground Neutral: 7, Insulated Phase Conductors - No of Strands: 10, Insulated Phase Conductors - Sizes (AWG): 1/0-1/0-1/0, Product Name (includes Ground): 1/0-1/0-1/0-2 Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 0 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836., Assembly:, Applications:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544., National Electric Code (NEC ) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 540, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 1/0-1/0-1/0-2, Allowable Ampacities for Direct Burial: 198, Code Name: Notre Dame, Finished Cable - Outside Diameter (in): 1.197, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.388, Neutral Conductor - Size (AWG): 2, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 10, Phase Conductors - Outside Diameter (in): 0.496, Phase Conductors - Size (AWG): 1/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 380, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 1/0-1/0-2, Allowable Ampacities for Direct Burial: 219, Code Name: Brenau, Finished Cable - Outside Diameter (in): 1.111, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.388, Neutral Conductor - Size (AWG): 2, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 10, Phase Conductors - Outside Diameter (in): 0.496, Phase Conductors - Size (AWG): 1/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 1/0-1/0-2, Standard Packaging (ft): 500’, Conductor Sizes (AWG): 1/0-1/0-2, Allowable Ampacities for Direct Burial: 219, Code Name: Brenau, Finished Cable - Outside Diameter (in): 1.111, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.388, Neutral Conductor - Size (AWG): 2, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 10, Phase Conductors - Outside Diameter (in): 0.496, Phase Conductors - Size (AWG): 1/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
P1621.jpg1 AWG, Stranded, Black, XHHW-2 Wire 1000’ Reel
Locke Part #: P1623MFG Part #: 341101701450 Compare
Color: Black, Outside Diameter: 0.438" (12.39 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 110, Allowable Ampacities (amps) @ 75°C: 130, Allowable Ampacities (amps) @ 90°C: 150, Approximate Net Weight: 303 lbs/1000 ft (451 kg/km), Insulation Thickness XLPE: 0.055" (2.03 mm), (AWG): 1 A great alternative to eliminate the need for lube. Slick outer surface for easy pulling., SuperSlick Elite XHHW-2/RW90 is available in sizes 8 AWG through 1000 KCMIL. On 250 KCMIL and larger, sequential foot markings located every foot for easy measuring. Rated VW-1., For 1 AWG through 4/0 AWG, sequential foot markings on master reels only unless otherwise specified., 6 AWG and larger rated Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr) flame test and ICEA T-29-520 (210,000 Btu/hr) flame test., Construction:, Conductors:, Stranded, uncoated bare copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8., Insulation:, Cross-linked polyethylene (XLPE) insulation per UL-44., Applications:, Type XHHW-2/RW90 is permitted for 600 volt applications and can be used in wet or dry locations at temperatures not to exceed 90, C., Suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less., Standards:, Underwriters Laboratories Standard UL-44., ASTM Stranding Class B3, B8, B787., Federal Specification A-A-59544. Canadian Standards Association C22.2 No. 38., NEMA WC-70/ICEA S-95-658. NFPA 70: National Electrical Code (NEC)., UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger)., ICEA T-29-520 (210,000 Btu/hr) Flame Test. ARRA 2009; Section 1605 "Buy American" Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 448, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 85, Allowable Ampacities (amps) @ 75°C: 100, Allowable Ampacities (amps) @ 90°C: 115, Nominal Diameter (in): 1.082, Allowable Ampacities (amps) @ **Dwelling: 110, Ground/Neutral - Sizes (AWG): 3, Ground/Neutral - Style/Ground Neutral: 7, Insulated Phase Conductors - No of Strands: 8, Insulated Phase Conductors - Sizes (AWG): 1-1-1, Product Name (includes Ground): 1-1-1-3 Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 0 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836., Assembly:, Applications:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544., National Electric Code (NEC ) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 471, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 2/0-2/0-1, Allowable Ampacities for Direct Burial: 249, Code Name: Converse, Finished Cable - Outside Diameter (in): 1.200, Neutral Conductor - No of Strands: 8, Neutral Conductor - Outside Diameter (in): 0.459, Neutral Conductor - Size (AWG): 1, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 12, Phase Conductors - Outside Diameter (in): 0.536, Phase Conductors - Size (AWG): 2/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 526, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 2/0-2/0-2/0, Allowable Ampacities for Direct Burial: 249, Code Name: Hunter, Finished Cable - Outside Diameter (in): 1.200, Neutral Conductor - No of Strands: 12, Neutral Conductor - Outside Diameter (in): 0.536, Neutral Conductor - Size (AWG): 2/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 12, Phase Conductors - Outside Diameter (in): 0.536, Phase Conductors - Size (AWG): 2/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 520, Standard Packaging (ft): 1500’, Conductor Sizes (AWG): 2/0-2/0-2/0, Code Name: Runcina, Phase Conductors - No of Strands: 12, Phase Conductors - Outside Diameter (in): 0.496, Phase Conductors - Size (AWG): 2/0, Phase Conductors - XLPE Thickness (in): 0.060, Bare Neutral Conductor - Finished OD (in): 0.447, Bare Neutral Conductor - No of Strands: 6+1, Bare Neutral Conductor - Rated Strength (lbs): 5300, Bare Neutral Conductor - Size (AWG): 2/0, Bare Neutral Conductor-Type: ACSR, Ampacity (XLPE): 230, Diameter of Final Construction (in): 1.066 Triplex overhead service drop cable has two black XLPE insulated aluminum conductors cabled around a bare-stranded ACSR 1350 Series alloy supporting neutral with steel support center wire., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation rated 90 C operation wet or dry., Manufactured and tested according to ANSI/ICEA S-76-474., Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts., Insulated conductors are surface printed for identification., Construction:, Conductors:, Insulated Conductor, : Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836., Neutral Conductor, : Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232., Insulation:, Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 C wet or dry., Applications:, Triplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90 C wet or dry., Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure., Suitable for 120-volt aerial service for outdoor lighting or for temporary service at construction sites., Standards:, ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232; ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 652, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 115, Allowable Ampacities (amps) @ 75°C: 135, Allowable Ampacities (amps) @ 90°C: 150, Nominal Diameter (in): 1.250, Allowable Ampacities (amps) @ **Dwelling: 150, Ground/Neutral - Sizes (AWG): 1, Ground/Neutral - Style/Ground Neutral: 8, Insulated Phase Conductors - No of Strands: 12, Insulated Phase Conductors - Sizes (AWG): 2/0-2/0-2/0, Product Name (includes Ground): 2/0-2/0-2/0-1 Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 0 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836., Assembly:, Applications:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544., National Electric Code (NEC ) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
P1621.jpg2 AWG, Stranded, Black, XHHW-2 Wire 1000’ Reel
Locke Part #: P5327MFG Part #: 341101601250 Compare
Color: Black, Outside Diameter: 0.382" (10.46 mm), Number of Strands: 7, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 95, Allowable Ampacities (amps) @ 75°C: 115, Allowable Ampacities (amps) @ 90°C: 130, Approximate Net Weight: 234 lbs/1000 ft (348 kg/km), Insulation Thickness XLPE: 0.045" (1.52 mm), (AWG): 2 A great alternative to eliminate the need for lube. Slick outer surface for easy pulling., SuperSlick Elite XHHW-2/RW90 is available in sizes 8 AWG through 1000 KCMIL. On 250 KCMIL and larger, sequential foot markings located every foot for easy measuring. Rated VW-1., For 1 AWG through 4/0 AWG, sequential foot markings on master reels only unless otherwise specified., 6 AWG and larger rated Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr) flame test and ICEA T-29-520 (210,000 Btu/hr) flame test., Construction:, Conductors:, Stranded, uncoated bare copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8., Insulation:, Cross-linked polyethylene (XLPE) insulation per UL-44., Applications:, Type XHHW-2/RW90 is permitted for 600 volt applications and can be used in wet or dry locations at temperatures not to exceed 90, C., Suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less., Standards:, Underwriters Laboratories Standard UL-44., ASTM Stranding Class B3, B8, B787., Federal Specification A-A-59544. Canadian Standards Association C22.2 No. 38., NEMA WC-70/ICEA S-95-658. NFPA 70: National Electrical Code (NEC)., UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger)., ICEA T-29-520 (210,000 Btu/hr) Flame Test. ARRA 2009; Section 1605 "Buy American" Compliant. Encore Wire Corp
P1615.jpg2 AWG, Stranded, USE-2 Aluminum Black Wire, 1000’ Rell
Locke Part #: P1615MFG Part #: 345101601250 Compare
Color: Black, Approximate Net Weight (lbs/1000 ft): 90, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 75°C: 90, Allowable Ampacities (amps) @ 90°C: 100, Size (AWG or KCMIL): 2, Approximate Overall Dimensions (in): 0.388, Compact Diameter of Aluminum Conductor (in): 0.268, No of Strands: 7, XLPE Insulation Thickness (in): 0.060 Insulation compound carries VW-1 (vertical wire flame) rating and FT2 (horizontal flame) rating and is sunlight-resistant (6 AWG and larger) in all colors., 1/0 AWG and larger are rated for CT use and comply with IEEE 1202/FT4 Flame Test., When used as RHH or RHW-2, cable complies with ICEA T-29-520 (210,000 Btu/hr) Flame Test., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, Insulation:, Cross-linked polyethylene (XLPE) per UL-854. Sunlight-resistant in all colors 6 AWG and larger, Applications:, Type USE-2, RHH or RHW-2 cables with Aluminum Alloy 8000 Series conductors are suitable for use in conduit and raceways installed underground in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90 C., Permitted for Type USE-2 per UL-854 for applications requiring direct burial., For applications requiring Type RHH or RHW-2, conductor temperatures shall not exceed 90 C in wet or dry locations., Type USE-2, RHH, or RHW-2 is permitted for 600 volt applications., Standards:, Underwriters Laboratories Standards UL-44; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836;, Federal Specification AA-59544; NEMA WC70 / ICEA S-95-658; NEMA RV4 2012; NFPA 70., National Electrical Code (NEC ). ARRA 2009 Section 1605 Buy American Compliant., IEEE 1202/FT4 Flame Test; ICEA T-29-520 (210,000 Btu/hr) Flame Test. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 294, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 75, Allowable Ampacities (amps) @ 75°C: 90, Allowable Ampacities (amps) @ 90°C: 100, Approximate Overall Dimensions (in): 0.597 x 0.957, Allowable Ampacities (amps) @ **Dwelling: 100, Ground/Neutral - Sizes (AWG): 2, Ground/Neutral - Style/Ground Neutral: Helical, Insulated Phase Conductors - No of Strands: 7, Insulated Phase Conductors - Sizes (AWG): 2-2, Conductor Sizes (includes Ground)(AWG or KCMIL): 2-2-2 Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836. The ground/neutral is evenly distributed and helically applied over the insulated conductors to produce the equivalent size required by UL-854., Application:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544; National Electrical Code (NEC) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 270, Standard Packaging (ft): 1800’, Conductor Sizes (AWG): 2-2-2, Code Name: Conch, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.358, Phase Conductors - Size (AWG): 2, Phase Conductors - XLPE Thickness (in): 0.045, Bare Neutral Conductor - Finished OD (in): 0.316, Bare Neutral Conductor - No of Strands: 6+1, Bare Neutral Conductor - Rated Strength (lbs): 2850, Bare Neutral Conductor - Size (AWG): 2, Bare Neutral Conductor-Type: ACSR, Ampacity (XLPE): 150, Diameter of Final Construction (in): 0.771 Triplex overhead service drop cable has two black XLPE insulated aluminum conductors cabled around a bare-stranded ACSR 1350 Series alloy supporting neutral with steel support center wire., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation rated 90 C operation wet or dry., Manufactured and tested according to ANSI/ICEA S-76-474., Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts., Insulated conductors are surface printed for identification., Construction:, Conductors:, Insulated Conductor, : Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836., Neutral Conductor, : Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232., Insulation:, Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 C wet or dry., Applications:, Triplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90 C wet or dry., Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure., Suitable for 120-volt aerial service for outdoor lighting or for temporary service at construction sites., Standards:, ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232; ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 364, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 75, Allowable Ampacities (amps) @ 75°C: 90, Allowable Ampacities (amps) @ 90°C: 100, Nominal Diameter (in): 0.950, Allowable Ampacities (amps) @ **Dwelling: 100, Ground/Neutral - Sizes (AWG): 4, Ground/Neutral - Style/Ground Neutral: 7, Insulated Phase Conductors - No of Strands: 7, Insulated Phase Conductors - Sizes (AWG): 2-2-2, Product Name (includes Ground): 2-2-2-4 Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 0 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836., Assembly:, Applications:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544., National Electric Code (NEC ) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 332, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 2-2-2-4, Allowable Ampacities for Direct Burial: 153, Code Name: Dyke, Finished Cable - Outside Diameter (in): 0.937, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.330, Neutral Conductor - Size (AWG): 4, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.388, Phase Conductors - Size (AWG): 2, Phase Conductors - XLPE Thickness (in): 0.060 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 241, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 2-2-4, Allowable Ampacities for Direct Burial: 168, Code Name: Stephens, Finished Cable - Outside Diameter (in): 0.869, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.333, Neutral Conductor - Size (AWG): 4, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.388, Phase Conductors - Size (AWG): 2, Phase Conductors - XLPE Thickness (in): 0.060 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 241, Standard Packaging (ft): 500’, Conductor Sizes (AWG): 2-2-4, Allowable Ampacities for Direct Burial: 168, Code Name: Stephens, Finished Cable - Outside Diameter (in): 0.869, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.333, Neutral Conductor - Size (AWG): 4, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.388, Phase Conductors - Size (AWG): 2, Phase Conductors - XLPE Thickness (in): 0.060 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 100, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 2-2-4-6, Finished Cable - Outside Diameter (in): 0.950, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.340, Neutral Conductor - Size (AWG): 4, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.399, Phase Conductors - Size (AWG): 2, Phase Conductors - XLPE Thickness (in): 0.060, Ground Cable - No of Strands: 6, Ground Cable - Outside Diameter (in): 0.295, Ground Cable - Size (AWG): 6, Ground Cable - XLPE Thickness: 0.060 Two black triple-rated USE-2/RHH/RHW-2 phase conductors cabled together with one white triple-rated USE-2/RHH/RHW-2 neutral conductor and one green insulated ground wire., All cables employ ASTM 8000 Series aluminum alloy conductors., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600-Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables., Also manufactured and tested according to UL-854, and UL-44., Conductors are surface printed for identification., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL 854, UL 44, and ANSI/ICEA S-105-692., Black XLPE insulation on phase conductors, white XLPE on neutral conductor, green XLPE on ground., Applications:, Quadruplex type USE-2/RHH/RHW-2 with Compact Stranded Aluminum Alloy 8000 Series conductors per ASTM B800; ASTM B801; ASTM B836., Suitable for electrical connections in mobile homes for permanent wiring according to the 2008 NEC., Suitable for wet and dry locations in conduit where temperatures do not exceed 90 C., Direct Burial in earth permitted for Type USE-2, RHH, and RHW-2 per UL854 where temperatures do not exceed 90 C. 600 volt rated. XLPE insulation is sunlight-resistant for 6 AWG and larger., 1/0 AWG and larger complies with IEEE 1202/UL FT-4 flame test., 1/0 AWG and larger also complies with ICEA T-29-520 (210,000 btu/hr) flame test., Standards:, Underwriters Laboratories Standards UL-854; UL-44; ANSI/ICEA S-105-692; IEEE 835-1994; Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836; ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
P1621.jpg250 KCMIL, Stranded, Black, XHHW-2 Wire 1000’ Reel
Locke Part #: P1621MFG Part #: 341102501550 Compare
Color: Black, Outside Diameter: 0.671" (17.05 mm), Number of Strands: 37, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 215, Allowable Ampacities (amps) @ 75°C: 255, Allowable Ampacities (amps) @ 90°C: 290, Approximate Net Weight: 826 lbs/1000 ft (1229 kg/km), Insulation Thickness XLPE: 0.065" (1.64 mm), (KCMIL): 250 A great alternative to eliminate the need for lube. Slick outer surface for easy pulling., SuperSlick Elite XHHW-2/RW90 is available in sizes 8 AWG through 1000 KCMIL. On 250 KCMIL and larger, sequential foot markings located every foot for easy measuring. Rated VW-1., For 1 AWG through 4/0 AWG, sequential foot markings on master reels only unless otherwise specified., 6 AWG and larger rated Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr) flame test and ICEA T-29-520 (210,000 Btu/hr) flame test., Construction:, Conductors:, Stranded, uncoated bare copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8., Insulation:, Cross-linked polyethylene (XLPE) insulation per UL-44., Applications:, Type XHHW-2/RW90 is permitted for 600 volt applications and can be used in wet or dry locations at temperatures not to exceed 90, C., Suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less., Standards:, Underwriters Laboratories Standard UL-44., ASTM Stranding Class B3, B8, B787., Federal Specification A-A-59544. Canadian Standards Association C22.2 No. 38., NEMA WC-70/ICEA S-95-658. NFPA 70: National Electrical Code (NEC)., UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger)., ICEA T-29-520 (210,000 Btu/hr) Flame Test. ARRA 2009; Section 1605 "Buy American" Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 844, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 250-250-3/0, Allowable Ampacities for Direct Burial: 356, Code Name: Pratt, Finished Cable - Outside Diameter (in): 1.550, Neutral Conductor - No of Strands: 15, Neutral Conductor - Outside Diameter (in): 0.583, Neutral Conductor - Size (AWG): 3/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 22, Phase Conductors - Outside Diameter (in): 0.710, Phase Conductors - Size (AWG): 250, Phase Conductors - XLPE Thickness (in): 0.095 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
P1621.jpg3/0 AWG, Stranded, Black, XHHW-2 Wire 1000’ Reel
Locke Part #: P1622MFG Part #: 341102001450 Compare
Color: Black, Outside Diameter: 0.564" (15.59 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 165, Allowable Ampacities (amps) @ 75°C: 200, Allowable Ampacities (amps) @ 90°C: 225, Approximate Net Weight: 577 lbs/1000 ft (859 kg/km), Insulation Thickness XLPE: 0.055" (2.03 mm), (AWG): 3/0 A great alternative to eliminate the need for lube. Slick outer surface for easy pulling., SuperSlick Elite XHHW-2/RW90 is available in sizes 8 AWG through 1000 KCMIL. On 250 KCMIL and larger, sequential foot markings located every foot for easy measuring. Rated VW-1., For 1 AWG through 4/0 AWG, sequential foot markings on master reels only unless otherwise specified., 6 AWG and larger rated Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr) flame test and ICEA T-29-520 (210,000 Btu/hr) flame test., Construction:, Conductors:, Stranded, uncoated bare copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8., Insulation:, Cross-linked polyethylene (XLPE) insulation per UL-44., Applications:, Type XHHW-2/RW90 is permitted for 600 volt applications and can be used in wet or dry locations at temperatures not to exceed 90, C., Suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less., Standards:, Underwriters Laboratories Standard UL-44., ASTM Stranding Class B3, B8, B787., Federal Specification A-A-59544. Canadian Standards Association C22.2 No. 38., NEMA WC-70/ICEA S-95-658. NFPA 70: National Electrical Code (NEC)., UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger)., ICEA T-29-520 (210,000 Btu/hr) Flame Test. ARRA 2009; Section 1605 "Buy American" Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 1105, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 350-350-4/0, Allowable Ampacities for Direct Burial: 431, Code Name: Wesleyan, Finished Cable - Outside Diameter (in): 1.810, Neutral Conductor - No of Strands: 19, Neutral Conductor - Outside Diameter (in): 0.635, Neutral Conductor - Size (AWG): 4/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 24, Phase Conductors - Outside Diameter (in): 0.806, Phase Conductors - Size (AWG): 350, Phase Conductors - XLPE Thickness (in): 0.096 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 1105, Standard Packaging (ft): 500’, Conductor Sizes (AWG): 350-350-4/0, Allowable Ampacities for Direct Burial: 431, Code Name: Wesleyan, Finished Cable - Outside Diameter (in): 1.810, Neutral Conductor - No of Strands: 19, Neutral Conductor - Outside Diameter (in): 0.635, Neutral Conductor - Size (AWG): 4/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 24, Phase Conductors - Outside Diameter (in): 0.806, Phase Conductors - Size (AWG): 350, Phase Conductors - XLPE Thickness (in): 0.096 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
P1621.jpg4/0 AWG, Stranded, Black, XHHW-2 Wire 1000’ Reel
Locke Part #: P5336MFG Part #: 341102101450 Compare
Color: Black, Outside Diameter: 0.620" (17.01 mm), Number of Strands: 19, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 60°C: 195, Allowable Ampacities (amps) @ 75°C: 230, Allowable Ampacities (amps) @ 90°C: 260, Approximate Net Weight: 718 lbs/1000 ft (1068 kg/km), Insulation Thickness XLPE: 0.055" (2.03 mm), (AWG): 4/0 A great alternative to eliminate the need for lube. Slick outer surface for easy pulling., SuperSlick Elite XHHW-2/RW90 is available in sizes 8 AWG through 1000 KCMIL. On 250 KCMIL and larger, sequential foot markings located every foot for easy measuring. Rated VW-1., For 1 AWG through 4/0 AWG, sequential foot markings on master reels only unless otherwise specified., 6 AWG and larger rated Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr) flame test and ICEA T-29-520 (210,000 Btu/hr) flame test., Construction:, Conductors:, Stranded, uncoated bare copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8., Insulation:, Cross-linked polyethylene (XLPE) insulation per UL-44., Applications:, Type XHHW-2/RW90 is permitted for 600 volt applications and can be used in wet or dry locations at temperatures not to exceed 90, C., Suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less., Standards:, Underwriters Laboratories Standard UL-44., ASTM Stranding Class B3, B8, B787., Federal Specification A-A-59544. Canadian Standards Association C22.2 No. 38., NEMA WC-70/ICEA S-95-658. NFPA 70: National Electrical Code (NEC)., UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger)., ICEA T-29-520 (210,000 Btu/hr) Flame Test. ARRA 2009; Section 1605 "Buy American" Compliant. Encore Wire Corp
P1621.jpg4/0 AWG, Stranded, Black, XHHW-2 Wire 500’ Reel
Locke Part #: P5328MFG Part #: 341102101440 Compare
Color: Black, Outside Diameter: 0.620" (17.01 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 195, Allowable Ampacities (amps) @ 75°C: 230, Allowable Ampacities (amps) @ 90°C: 260, Approximate Net Weight: 718 lbs/1000 ft (1068 kg/km), Insulation Thickness XLPE: 0.055" (2.03 mm), (AWG): 4/0 A great alternative to eliminate the need for lube. Slick outer surface for easy pulling., SuperSlick Elite XHHW-2/RW90 is available in sizes 8 AWG through 1000 KCMIL. On 250 KCMIL and larger, sequential foot markings located every foot for easy measuring. Rated VW-1., For 1 AWG through 4/0 AWG, sequential foot markings on master reels only unless otherwise specified., 6 AWG and larger rated Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr) flame test and ICEA T-29-520 (210,000 Btu/hr) flame test., Construction:, Conductors:, Stranded, uncoated bare copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8., Insulation:, Cross-linked polyethylene (XLPE) insulation per UL-44., Applications:, Type XHHW-2/RW90 is permitted for 600 volt applications and can be used in wet or dry locations at temperatures not to exceed 90, C., Suitable for applications requiring low-leaking circuits and a dielectric constant of 3.5 or less., Standards:, Underwriters Laboratories Standard UL-44., ASTM Stranding Class B3, B8, B787., Federal Specification A-A-59544. Canadian Standards Association C22.2 No. 38., NEMA WC-70/ICEA S-95-658. NFPA 70: National Electrical Code (NEC)., UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger)., ICEA T-29-520 (210,000 Btu/hr) Flame Test. ARRA 2009; Section 1605 "Buy American" Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 783, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 150, Allowable Ampacities (amps) @ 75°C: 180, Allowable Ampacities (amps) @ 90°C: 205, Approximate Overall Dimensions (in): 0.880 x 1.474, Allowable Ampacities (amps) @ **Dwelling: 200, Ground/Neutral - Sizes (AWG): 4/0, Ground/Neutral - Style/Ground Neutral: Helical, Insulated Phase Conductors - No of Strands: 19, Insulated Phase Conductors - Sizes (AWG): 4/0-4/0-4/0, Conductor Sizes (includes Ground)(AWG or KCMIL): 4/0-4/0-4/0 Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836. The ground/neutral is evenly distributed and helically applied over the insulated conductors to produce the equivalent size required by UL-854., Application:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544; National Electrical Code (NEC) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 695, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 4/0-4/0-2/0, Allowable Ampacities for Direct Burial: 322, Code Name: Sweetbriar, Finished Cable - Outside Diameter (in): 1.420, Neutral Conductor - No of Strands: 12, Neutral Conductor - Outside Diameter (in): 0.536, Neutral Conductor - Size (AWG): 2/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 19, Phase Conductors - Outside Diameter (in): 0.635, Phase Conductors - Size (AWG): 4/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 4-4-4, Standard Packaging (ft): 500’, Conductor Sizes (AWG): 4/0-4/0-2/0, Allowable Ampacities for Direct Burial: 322, Code Name: Sweetbriar, Finished Cable - Outside Diameter (in): 1.420, Neutral Conductor - No of Strands: 12, Neutral Conductor - Outside Diameter (in): 0.536, Neutral Conductor - Size (AWG): 2/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 19, Phase Conductors - Outside Diameter (in): 0.635, Phase Conductors - Size (AWG): 4/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 200, Approximate Net Weight (lbs/1000 ft): 797, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 4/0-4/0-2/0-4, Neutral Conductor - No of Strands: 12, Neutral Conductor - Outside Diameter (in): 0.550, Neutral Conductor - Size (AWG): 2/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 19, Phase Conductors - Outside Diameter (in): 0.648, Phase Conductors - Size (AWG): 4/0, Phase Conductors - XLPE Thickness (in): 0.080, Ground Cable - No of Strands: 6, Ground Cable - Outside Diameter (in): 0.340, Ground Cable - Size (AWG): 4, Ground Cable - XLPE Thickness: 0.060 Two black triple-rated USE-2/RHH/RHW-2 phase conductors cabled together with one white triple-rated USE-2/RHH/RHW-2 neutral conductor and one green insulated ground wire., All cables employ ASTM 8000 Series aluminum alloy conductors., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600-Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables., Also manufactured and tested according to UL-854, and UL-44., Conductors are surface printed for identification., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL 854, UL 44, and ANSI/ICEA S-105-692., Black XLPE insulation on phase conductors, white XLPE on neutral conductor, green XLPE on ground., Applications:, Quadruplex type USE-2/RHH/RHW-2 with Compact Stranded Aluminum Alloy 8000 Series conductors per ASTM B800; ASTM B801; ASTM B836., Suitable for electrical connections in mobile homes for permanent wiring according to the 2008 NEC., Suitable for wet and dry locations in conduit where temperatures do not exceed 90 C., Direct Burial in earth permitted for Type USE-2, RHH, and RHW-2 per UL854 where temperatures do not exceed 90 C. 600 volt rated. XLPE insulation is sunlight-resistant for 6 AWG and larger., 1/0 AWG and larger complies with IEEE 1202/UL FT-4 flame test., 1/0 AWG and larger also complies with ICEA T-29-520 (210,000 btu/hr) flame test., Standards:, Underwriters Laboratories Standards UL-854; UL-44; ANSI/ICEA S-105-692; IEEE 835-1994; Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836; ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 200, Standard Packaging (ft): 500’, Conductor Sizes (AWG): 4/0-4/0-2/0-4, Finished Cable - Outside Diameter (in): 1.550, Neutral Conductor - No of Strands: 12, Neutral Conductor - Outside Diameter (in): 0.550, Neutral Conductor - Size (AWG): 2/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 19, Phase Conductors - Outside Diameter (in): 0.648, Phase Conductors - Size (AWG): 4/0, Phase Conductors - XLPE Thickness (in): 0.080, Ground Cable - No of Strands: 6, Ground Cable - Outside Diameter (in): 0.340, Ground Cable - Size (AWG): 4, Ground Cable - XLPE Thickness: 0.060 Two black triple-rated USE-2/RHH/RHW-2 phase conductors cabled together with one white triple-rated USE-2/RHH/RHW-2 neutral conductor and one green insulated ground wire., All cables employ ASTM 8000 Series aluminum alloy conductors., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600-Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables., Also manufactured and tested according to UL-854, and UL-44., Conductors are surface printed for identification., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL 854, UL 44, and ANSI/ICEA S-105-692., Black XLPE insulation on phase conductors, white XLPE on neutral conductor, green XLPE on ground., Applications:, Quadruplex type USE-2/RHH/RHW-2 with Compact Stranded Aluminum Alloy 8000 Series conductors per ASTM B800; ASTM B801; ASTM B836., Suitable for electrical connections in mobile homes for permanent wiring according to the 2008 NEC., Suitable for wet and dry locations in conduit where temperatures do not exceed 90 C., Direct Burial in earth permitted for Type USE-2, RHH, and RHW-2 per UL854 where temperatures do not exceed 90 C. 600 volt rated. XLPE insulation is sunlight-resistant for 6 AWG and larger., 1/0 AWG and larger complies with IEEE 1202/UL FT-4 flame test., 1/0 AWG and larger also complies with ICEA T-29-520 (210,000 btu/hr) flame test., Standards:, Underwriters Laboratories Standards UL-854; UL-44; ANSI/ICEA S-105-692; IEEE 835-1994; Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836; ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 780, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 4/0-4/0-4/0, Allowable Ampacities for Direct Burial: 322, Code Name: Monmouth, Finished Cable - Outside Diameter (in): 1.420, Neutral Conductor - No of Strands: 19, Neutral Conductor - Outside Diameter (in): 0.635, Neutral Conductor - Size (AWG): 4/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 19, Phase Conductors - Outside Diameter (in): 0.635, Phase Conductors - Size (AWG): 4/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 965, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 150, Allowable Ampacities (amps) @ 75°C: 180, Allowable Ampacities (amps) @ 90°C: 205, Nominal Diameter (in): 1.425, Allowable Ampacities (amps) @ **Dwelling: 200, Ground/Neutral - Sizes (AWG): 2/0, Ground/Neutral - Style/Ground Neutral: 12, Insulated Phase Conductors - No of Strands: 19, Insulated Phase Conductors - Sizes (AWG): 4/0-4/0-4/0, Product Name (includes Ground): 4/0-4/0-4/0-2/0 Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 0 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836., Assembly:, Applications:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544., National Electric Code (NEC ) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 962, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 4/0-4/0-4/0-2/0, Allowable Ampacities for Direct Burial: 291, Code Name: Wake Forest, Finished Cable - Outside Diameter (in): 1.533, Neutral Conductor - No of Strands: 12, Neutral Conductor - Outside Diameter (in): 0.536, Neutral Conductor - Size (AWG): 2/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 19, Phase Conductors - Outside Diameter (in): 0.635, Phase Conductors - Size (AWG): 4/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
P1615.jpg4 AWG, Stranded, USE-2 Aluminum Black Wire, 1000’ Rell
Locke Part #: P1616MFG Part #: 345101401250 Compare
Color: Black, Approximate Net Weight (lbs/1000 ft): 62, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 75°C: 65, Allowable Ampacities (amps) @ 90°C: 75, Size (AWG or KCMIL): 4, Approximate Overall Dimensions (in): 0.333, Compact Diameter of Aluminum Conductor (in): 0.213, No of Strands: 7, XLPE Insulation Thickness (in): 0.060 Insulation compound carries VW-1 (vertical wire flame) rating and FT2 (horizontal flame) rating and is sunlight-resistant (6 AWG and larger) in all colors., 1/0 AWG and larger are rated for CT use and comply with IEEE 1202/FT4 Flame Test., When used as RHH or RHW-2, cable complies with ICEA T-29-520 (210,000 Btu/hr) Flame Test., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, Insulation:, Cross-linked polyethylene (XLPE) per UL-854. Sunlight-resistant in all colors 6 AWG and larger, Applications:, Type USE-2, RHH or RHW-2 cables with Aluminum Alloy 8000 Series conductors are suitable for use in conduit and raceways installed underground in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90 C., Permitted for Type USE-2 per UL-854 for applications requiring direct burial., For applications requiring Type RHH or RHW-2, conductor temperatures shall not exceed 90 C in wet or dry locations., Type USE-2, RHH, or RHW-2 is permitted for 600 volt applications., Standards:, Underwriters Laboratories Standards UL-44; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836;, Federal Specification AA-59544; NEMA WC70 / ICEA S-95-658; NEMA RV4 2012; NFPA 70., National Electrical Code (NEC ). ARRA 2009 Section 1605 Buy American Compliant., IEEE 1202/FT4 Flame Test; ICEA T-29-520 (210,000 Btu/hr) Flame Test. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 175, Standard Packaging (ft): 1500’, Conductor Sizes (AWG): 4-4-4, Code Name: Periwinkle, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.303, Phase Conductors - Size (AWG): 4, Phase Conductors - XLPE Thickness (in): 0.045, Bare Neutral Conductor - Finished OD (in): 0.250, Bare Neutral Conductor - No of Strands: 6+1, Bare Neutral Conductor - Rated Strength (lbs): 1860, Bare Neutral Conductor - Size (AWG): 4, Bare Neutral Conductor-Type: ACSR, Ampacity (XLPE): 115, Diameter of Final Construction (in): 0.653 Triplex overhead service drop cable has two black XLPE insulated aluminum conductors cabled around a bare-stranded ACSR 1350 Series alloy supporting neutral with steel support center wire., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation rated 90 C operation wet or dry., Manufactured and tested according to ANSI/ICEA S-76-474., Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts., Insulated conductors are surface printed for identification., Construction:, Conductors:, Insulated Conductor, : Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836., Neutral Conductor, : Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232., Insulation:, Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 C wet or dry., Applications:, Triplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90 C wet or dry., Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure., Suitable for 120-volt aerial service for outdoor lighting or for temporary service at construction sites., Standards:, ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232; ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 185, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 4-4-4, Allowable Ampacities for Direct Burial: 130, Code Name: Vassar, Finished Cable - Outside Diameter (in): 0.744, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.333, Neutral Conductor - Size (AWG): 4, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.333, Phase Conductors - Size (AWG): 4, Phase Conductors - XLPE Thickness (in): 0.060 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
P1605.jpg6-6 AWG, Stranded, Shepard AL Overhead Wire, 500’ Reel
Locke Part #: P1605MFG Part #: 378141201240 Compare
Approximate Net Weight (lbs/1000 ft): 75, Standard Packaging (ft): 500’, Conductor Sizes (AWG): 6-6, Code Name: Shepard, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.259, Phase Conductors - Size (AWG): 6, Bare Neutral Conductor - Finished OD (in): 0.198, Bare Neutral Conductor - No of Strands: 6+1, Bare Neutral Conductor - Rated Strength (lbs): 1190, Bare Neutral Conductor - Size (AWG): 6, Bare Neutral Conductor-Type: ACSR, Ampacity (XLPE): 110, Diameter of Final Construction (in): 0.457, Phase Conductors - Insulation Thickness (in): 0.045 Duplex overhead service drop cable has one black XLPE insulated aluminum conductor cabled around a bare-stranded ACSR 1350 Series alloy supporting neutral with steel support center wire., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation rated 90 C operation wet or dry., Manufactured and tested according to ANSI/ICEA S-76-474., Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts., Insulated conductor is surface printed for identification., Construction:, Conductors:, Insulated Conductor, : Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836., Neutral Conductor, : Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232., Insulation:, Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 C wet or dry., Applications:, Duplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90 C wet or dry., Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure., Suitable for 120-volt aerial service for outdoor lighting or for temporary service at construction sites., Standards:, ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 105, Standard Packaging (ft): 2200’, Conductor Sizes (AWG): 6-6-6, Code Name: Voluta, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.259, Phase Conductors - Size (AWG): 6, Phase Conductors - XLPE Thickness (in): 0.045, Bare Neutral Conductor - Finished OD (in): 0.198, Bare Neutral Conductor - No of Strands: 6+1, Bare Neutral Conductor - Rated Strength (lbs): 1190, Bare Neutral Conductor - Size (AWG): 6, Bare Neutral Conductor-Type: ACSR, Ampacity (XLPE): 110, Diameter of Final Construction (in): 0.558 Triplex overhead service drop cable has two black XLPE insulated aluminum conductors cabled around a bare-stranded ACSR 1350 Series alloy supporting neutral with steel support center wire., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation rated 90 C operation wet or dry., Manufactured and tested according to ANSI/ICEA S-76-474., Standard for Neutral Supported Power Cable Assemblies with Weather-Resistant Extruded Insulations Rated 600 Volts., Insulated conductors are surface printed for identification., Construction:, Conductors:, Insulated Conductor, : Compact Stranded Conductors, Aluminum Alloy 1350 Series per ASTM B230; ASTM B609; ASTM B231; ASTM B836., Neutral Conductor, : Stranded Aluminum Conductor Steel Reinforced (ACSR), 1350 Series Alloy Bare Supporting Neutral with Steel Support Center Wire per ASTM B230; ASTM B232., Insulation:, Cross-link polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 C wet or dry., Applications:, Triplex overhead service drop cable with ACSR 1350 Series alloy supporting neutral is designed for applications not exceeding 600 volts with a maximum conductor operating temperature of 90 C wet or dry., Primarily used for delivering single phase power from secondary power lines or pole mounted transformers to service entrance heads of a building or structure., Suitable for 120-volt aerial service for outdoor lighting or for temporary service at construction sites., Standards:, ANSI/ICEA S-76-474; ASTM B233; ASTM B836; ASTM B232; ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp