Loading ...

Loading ...

Search in: Insulation Category

L510.jpg.475" For all 1/2", 2lb. Liner Box of 1000
Locke Part #: L0510MFG Part #: LF CMF050
Description Ext.: 1000 ct PINCHER IMPACT F The premium quality impact fastener Thru insulation impact fasteners. CAIN MFG. CO INC
L510.jpg.63" dia for all 1", 12lb. Liner Box of 1000
Locke Part #: L0529MFG Part #: LF CMF 100
Description Ext.: PINCHER IMPACT FSTNR 1" The premium quality impact fastener Thru insulation impact fasteners. CAIN MFG. CO INC
Width (in): 48, Length (ft): 100, Thickness (in): 1-1/2, K-Value (Btu•in / h•ft²•°F): 0.29, K-Value (W / m•°C): 0.042, R-Value (h•ft²•°F / Btu): 5.2, R-Value (m²•°C / W): 0.92, Model Building Codes: ICC, Fire Safety Standards: NFPA 90A, NFPA 90B, Facing: FSK/PSK, Installed R-value (h•ft²•°F / btu): 4.2, Installed R-value (m²•°C / W): 0.74, Installed K-value (Btu•in / h•ft² •°F): 0.27, Installed K-value (W / m•°C): 0.039, Product Type: 75 (0.75lbs./cu. ft.), Water Vapor Sorption: ASTM C1104 < 5% by weight Lower Energy Usage: Duct wrap products provide thermal efficiency that reduces unwanted heat loss or gain from equipment and ductwork. This means a likely savings of energy and improved system performance., Condensation Control: When properly installed in the correct thickness, duct wrap virtually eliminates condensation problems on cold duct surfaces., SoftTouch: Our duct wrap products are now made with SoftTouch for a softer, less itchy product., Applicable Standards:, Material Standards:, ASTM C1290, ASTM C553, Type I; Type 75 Duct Wrap, Type II; Type 100 & 150 Duct Wrap, Type III; Type 150 Duct Wrap, CAN/CGSB-51.11-92, ASTM C1136, FSK and white PSK, Type II, Gray PSK, Type IV, Fire Resistance:, Fire Hazard Classification:, UL 723, ASTM E84, NFPA 255, CAN/ULC-S102-M88, Max. Flame Spread Index: 25, Max Smoke Developed Index: 50, Non-Combustible: ASTM E136, Meets tests requirements, Physical/Chemical Properties:, Operating Limits:, Temperature: ASTM C411, Faced: Max. 250 F (121 C), Unfaced: Max. 450 F (232 C), Water Vapor Transmission, Facing: ASTM E96, Dessicant Method, FSK and white PSK: Max. 0.02 perms - 1.15 x 10-9 g/, Pa-s-m2, Gray PSK: Max. 0.09 perms - 5.17 x 10-9 g/, Pa-s-m2, Corrosiveness: ASTM C665, Pass test requirements, Fungi Resistance: ASTM C1338, Pass test requirements, Odor Emission: ASTM C1304, Pass test requirements CERTAINTEED INSULATION 740377932619
Width (in): 48, Length (ft): 75, Thickness (in): 2, K-Value (Btu•in / h•ft²•°F): 0.29, K-Value (W / m•°C): 0.042, R-Value (h•ft²•°F / Btu): 6.9, R-Value (m²•°C / W): 1.22, Model Building Codes: ICC, Fire Safety Standards: NFPA 90A, NFPA 90B, Facing: FSK/PSK, Installed R-value (h•ft²•°F / btu): 5.7, Installed R-value (m²•°C / W): 1.00, Installed K-value (Btu•in / h•ft² •°F): 0.26, Installed K-value (W / m•°C): 0.038, Product Type: 75 (0.75lbs./cu. ft.), Water Vapor Sorption: ASTM C1104 < 5% by weight Features:, Lower Energy Usage: Duct wrap products provide thermal efficiency that reduces unwanted heat loss or gain from equipment and ductwork. This means a likely savings of energy and improved system performance., Condensation Control: When properly installed in the correct thickness, duct wrap virtually eliminates condensation problems on cold duct surfaces., SoftTouch: Our duct wrap products are now made with SoftTouch for a softer, less itchy product., Applicable Standards:, Material Standards:, ASTM C1290, ASTM C553, Type I; Type 75 Duct Wrap, Type II; Type 100 & 150 Duct Wrap, Type III; Type 150 Duct Wrap, CAN/CGSB-51.11-92, ASTM C1136, FSK and white PSK, Type II, Gray PSK, Type IV, Fire Resistance:, Fire Hazard Classification:, UL 723, ASTM E84, NFPA 255, CAN/ULC-S102-M88, Max. Flame Spread Index: 25, Max Smoke Developed Index: 50, Non-Combustible: ASTM E136, Meets tests requirements, Physical/Chemical Properties:, Operating Limits:, Temperature: ASTM C411, Faced: Max. 250 F (121 C), Unfaced: Max. 450 F (232 C), Water Vapor Transmission, Facing: ASTM E96, Dessicant Method, FSK and white PSK: Max. 0.02 perms - 1.15 x 10-9 g/Pa-s-m2, Gray PSK: Max. 0.09 perms - 5.17 x 10-9 g/Pa-s-m2, Corrosiveness: ASTM C665, Passes test requirements, Fungi Resistance: ASTM C1338, Passes test requirements, Odor Emission: ASTM C1304, Pass test requirements CERTAINTEED INSULATION 740377932626
Width (in): 48, Length (ft): 50, Thickness (in): 3, K-Value (Btu•in / h•ft²•°F): 0.31, K-Value (W / m•°C): 0.045, R-Value (h•ft²•°F / Btu): 9.6, R-Value (m²•°C / W): 1.69, Model Building Codes: ICC, Fire Safety Standards: NFPA 90A, NFPA 90B, Facing: FSK/PSK, Installed R-value (h•ft²•°F / btu): 8.3, Installed R-value (m²•°C / W): 1.41, Installed K-value (Btu•in / h•ft² •°F): 0.28, Installed K-value (W / m•°C): 0.041, Product Type: 75 (0.75lbs./cu. ft.), Water Vapor Sorption: ASTM C1104 < 5% by weight Lower Energy Usage: Duct wrap products provide thermal efficiency that reduces unwanted heat loss or gain from equipment and ductwork. This means a likely savings of energy and improved system performance., Condensation Control: When properly installed in the correct thickness, duct wrap virtually eliminates condensation problems on cold duct surfaces., SoftTouch: Our duct wrap products are now made with SoftTouch for a softer, less itchy product., Applicable Standards:, Material Standards:, ASTM C1290, ASTM C553, Type I; Type 75 Duct Wrap, Type II; Type 100 & 150 Duct Wrap, Type III; Type 150 Duct Wrap, CAN/CGSB-51.11-92, ASTM C1136, FSK and white PSK, Type II, Gray PSK, Type IV, Fire Resistance:, Fire Hazard Classification:, UL 723, ASTM E84, NFPA 255, CAN/ULC-S102-M88, Max. Flame Spread Index: 25, Max Smoke Developed Index: 50, Non-Combustible: ASTM E136, Meets tests requirements, Physical/Chemical Properties:, Operating Limits:, Temperature: ASTM C411, Faced: Max. 250 F (121 C), Unfaced: Max. 450 F (232 C), Water Vapor Transmission, Facing: ASTM E96, Dessicant Method, FSK and white PSK: Max. 0.02 perms - 1.15 x 10-9 g/, Pa-s-m2, Gray PSK: Max. 0.09 perms - 5.17 x 10-9 g/, Pa-s-m2, Corrosiveness: ASTM C665, Pass test requirements, Fungi Resistance: ASTM C1338, Pass test requirements, Odor Emission: ASTM C1304, Pass test requirements CERTAINTEED INSULATION 740377932657
L541.jpg1" Pin Size 1" H.D. 3 Lb. Liner Box of 1000
Locke Part #: L0543MFG Part #: LF CWF 150
Description Ext.: POINTER WELD FSTNR 1" Thru Insulation weld fastener. Sharp Rolled Point CAIN MFG. CO INC
L541.jpg1" Pin Size 1" H.D. 3 Lb. Liner Box of 5000
Locke Part #: L0542MFG Part #: LF-CWF-150B
Description Ext.: POINTER WELD FASTNER 1" Thru Insulation weld fastener. Sharp Rolled Point CAIN MFG. CO INC
L541.jpg1/2" Pin Size 1/2" 2 Lb. Liner Box of 5000
Locke Part #: L0541MFG Part #: LF-CWF-50B
Description Ext.: POINTER WELD FSTNR Thru Insulation weld fastener. Sharp Rolled Point CAIN MFG. CO INC
L514.jpg1-1/4" Duct Board Straight Clear Pins
Locke Part #: L0514MFG Part #: LFWP114
Description Ext.: 1 1/4" DUCT BD STR CLR CAIN MFG. CO INC
L1331.jpg1-1/4" Self AdhesiveHanger
Locke Part #: L1332MFG Part #: LF-SP-1250
Description Ext.: 1 1/4" SELF ADHESIVE CAIN MFG. CO INC
Description Ext.: 1 1/4" DUCT BD STR CLR CAIN MFG. CO INC
L1961.jpg10" x 5’ Foil Sleeve R6
Locke Part #: L1260MFG Part #: 010 R-6 10"
Size: 10"x5’ r6, Description Ext.: 010 10" X 5’ FOIL SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg10" x 5’ Foil Sleeve R8
Locke Part #: L1967MFG Part #: 010 R8 10" X 5'
Size: 10"x5’ r8, Description Ext.: 010 9" X 5’ R8 SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg12" x 5’ Foil Sleeve R6
Locke Part #: L1262MFG Part #: 010 R-6 12"
Size: 12"x5’ r6, Description Ext.: 010 12" X 5’ FOIL SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg12" x 5’ Foil Sleeve R8
Locke Part #: L1968MFG Part #: 010 R8 12" X 5'
Size: 12"x5’ r8, Description Ext.: 010 10" X 5’ R8 SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg14" x 5’ Foil Sleeve R6
Locke Part #: L1263MFG Part #: 010 R-6 14"
Size: 14"x5’ r6, Description Ext.: 010 14" X 5’ FOIL SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg14" x 5’ Foil Sleeve R8
Locke Part #: L1969MFG Part #: 010 R8 14" X 5'
Size: 14"x5’ r8, Description Ext.: 010 12" X 5’ R8 SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
Width (in): 47.5, Length (ft): 100, Thickness (in): 1, K-Value (Btu•in / h•ft²•°F): 0.24, K-Value (W / m•°C): 0.035, R-Value (h•ft²•°F / Btu): 4.2, R-Value (m²•°C / W): 0.73, Product Type: 150, Water Vapor Sorption: ASTM C1104 < 3% by weight, Corrosiveness: ASTM C665 Pass, Bacteria Resistance: ASTM G22 No Growth, Fungi Resistance: ASTM C1338 and ASTM G21 Pass; No Growth, Water Repellency Rating: INDA IST 80.6-92 > 4, Density: 1.5 pcf (24 kg/m2), C-Value (Btu / h•ft²•°F): 0.24, C-Value (W / m²•°C): 1.36, NRC: 0.70 Quiet Operation: ToughGard duct liner helps absorb equipment and air rush noises over a broad spectrum of sound. Noise is trapped and dissipated within the glass fiber matrix., Thermal Protection: All products offer excellent thermal-insulating properties and lower HVAC operating costs by reducing energy consumption. This saves natural resources and reduces emissions into the atmosphere., Water Repellency: The thermal properties of duct liner help control condensation, which helps improve indoor air quality by reducing unwanted moisture, Low Emitting: Certified by the GREENGUARD Environmental Institute., Low Air Resistance: The smooth ToughGard air stream surface offers low air resistance to deliver efficient HVAC system operation., Resists Microbial Growth: The air stream surface contains an EPA registered antimicrobial agent in order to reduce the potential of microbial growth that may affect this product. The antimicrobial properties are intended to only protect this product., Durable: The strength and resiliency of the ToughGard surface provides outstanding resistance against puncturing, tearing and other damage during fabrication, installation, and periodic system maintenance., Long-lasting and Non-corrosive: Inert fiber glass will not deteriorate or provide sustenance for vermin or rodents, and it will not corrode the sheet metal it insulates., Applicable Standards:, Model Building Codes:, Material Standards:, Fire Safety Standards:, Fire Hazard Classification:, Limited Combustible:, Physical/Chemical Properties:, Operating Limits:, Temperature:, Air Velocity:, ICC, California Title 24, ASTM C1071, Type I, CAN/CGSB-S1.11-92, NFPA 90A, NFPA 90B, UL 723, ASTM E84, NFPA 255, CAN/ULC-S102, Max. Flame Spread Index: 25, Max Smoke Developed Index: 50, NFPA 259 CERTAINTEED INSULATION 740377968816
CERTAINTEED INSULATION 740377091156
L1961.jpg16" x 5’ Foil Sleeve R6
Locke Part #: L1265MFG Part #: 010 R-6 16"
Size: 16"x5’ r6, Description Ext.: 010 16" X 5’ FOIL SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg16" x 5’ Foil Sleeve R8
Locke Part #: L1949MFG Part #: 010 R8 16" X 5'
Size: 16"x5’ r8, Description Ext.: 010 14" X 5’ R8 SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
Size: 12", MFG#: T1DK00002, Sq Ft: 40, Pcs/Box: 40 Pcs Includes:, 50 L Shaped Foam Spacers ( 2 x 2 x 1 x 48 ), Roll of Double Coated Tape ( 1 x 180 ) THERMO MANUFACTURING
Size: 48", MFG#: T1DK00001, Sq Ft: 200, Pcs/Box: 50 Pcs Includes:, 50 L Shaped Foam Spacers ( 2 x 2 x 1 x 48 ), Roll of Double Coated Tape ( 1 x 180 ) THERMO MANUFACTURING
Width (in): 47.5, Length (ft): 100, Thickness (in): 1/2, K-Value (Btu•in / h•ft²•°F): 0.25, K-Value (W / m•°C): 0.036, R-Value (h•ft²•°F / Btu): 2.0, R-Value (m²•°C / W): 0.35, Product Type: 200, Water Vapor Sorption: ASTM C1104 < 3% by weight, Corrosiveness: ASTM C665 Pass, Bacteria Resistance: ASTM G22 No Growth, Density: 2.0 pcf (32 kg/m3), C-Value (Btu / h•ft²•°F): 0.5, C-Value (W / m²•°C): 2.84, NRC: 0.45 Quiet Operation: ToughGard duct liner helps absorb equipment and air rush noises over a broad spectrum of sound. Noise is trapped and dissipated within the glass fiber matrix., Thermal Protection: All products offer excellent thermal-insulating properties and lower HVAC operating costs by reducing energy consumption. This saves natural resources and reduces emissions into the atmosphere., Water Repellency: The thermal properties of duct liner help control condensation, which helps improve indoor air quality by reducing unwanted moisture., Low Emitting: Certified by the GREENGUARD Environmental Institute., Low Air Resistance: The smooth ToughGard air stream surface offers low air resistance to deliver efficient HVAC system operation., Resists Microbial Growth: The air stream surface contains an EPA registered antimicrobial agent in order to reduce the potential of microbial growth that may affect this product. The antimicrobial properties are intended to only protect this product., Durable: The strength and resiliency of the ToughGard surface provides outstanding resistance against puncturing, tearing and other damage during fabrication, installation, and periodic system maintenance., Long-lasting and Non-corrosive: Inert fiber glass will not deteriorate or provide sustenance for vermin or rodents, and it will not corrode the sheet metal it insulates., Applicable Standards:, Model Building Codes: ICC, California Title 24, Material Standards: ASTM C1071, CAN/CGSB-51.11-92, Fire Safety Standards: NFPA 90A, NFPA 90B, Fire Hazard Classification:, UL 723, ASTM E84, NFPA 255, CAN/ULC-S102, Max. Flame Spread Index: 25, Max Smoke Developed Index: 50, Limited Combustible: NFPA 259 CERTAINTEED INSULATION 740377091255
Width (in): 59.5, Length (ft): 100, Thickness (in): 1/2, K-Value (Btu•in / h•ft²•°F): 0.25, K-Value (W / m•°C): 0.036, R-Value (h•ft²•°F / Btu): 2.0, R-Value (m²•°C / W): 0.35, Product Type: 200, Water Vapor Sorption: ASTM C1104 < 3% by weight, Corrosiveness: ASTM C665 Pass, Bacteria Resistance: ASTM G22 No Growth, Density: 2.0 pcf (32 kg/m3), C-Value (Btu / h•ft²•°F): 0.5, C-Value (W / m²•°C): 2.84, NRC: 0.45 Quiet Operation: ToughGard duct liner helps absorb equipment and air rush noises over a broad spectrum of sound. Noise is trapped and dissipated within the glass fiber matrix., Thermal Protection: All products offer excellent thermal-insulating properties and lower HVAC operating costs by reducing energy consumption. This saves natural resources and reduces emissions into the atmosphere., Water Repellency: The thermal properties of duct liner help control condensation, which helps improve indoor air quality by reducing unwanted moisture., Low Emitting: Certified by the GREENGUARD Environmental Institute., Low Air Resistance: The smooth ToughGard air stream surface offers low air resistance to deliver efficient HVAC system operation., Resists Microbial Growth: The air stream surface contains an EPA registered antimicrobial agent in order to reduce the potential of microbial growth that may affect this product. The antimicrobial properties are intended to only protect this product., Durable: The strength and resiliency of the ToughGard surface provides outstanding resistance against puncturing, tearing and other damage during fabrication, installation, and periodic system maintenance., Long-lasting and Non-corrosive: Inert fiber glass will not deteriorate or provide sustenance for vermin or rodents, and it will not corrode the sheet metal it insulates., Applicable Standards:, Model Building Codes: ICC, California Title 24, Material Standards: ASTM C1071, CAN/CGSB-51.11-92, Fire Safety Standards: NFPA 90A, NFPA 90B, Fire Hazard Classification:, UL 723, ASTM E84, NFPA 255, CAN/ULC-S102, Max. Flame Spread Index: 25, Max Smoke Developed Index: 50, Limited Combustible: NFPA 259 CERTAINTEED INSULATION 740377091293
Width (in): 35.5, Length (ft): 100, Thickness (in): 1/2, K-Value (Btu•in / h•ft²•°F): 0.25, K-Value (W / m•°C): 0.036, R-Value (h•ft²•°F / Btu): 2.0, R-Value (m²•°C / W): 0.35, Product Type: 200, Water Vapor Sorption: ASTM C1104 < 3% by weight, Corrosiveness: ASTM C665 Pass, Bacteria Resistance: ASTM G22 No Growth, Density: 2.0 pcf (32 kg/m3), C-Value (Btu / h•ft²•°F): 0.5, C-Value (W / m²•°C): 2.84, NRC: 0.45 Quiet Operation: ToughGard duct liner helps absorb equipment and air rush noises over a broad spectrum of sound. Noise is trapped and dissipated within the glass fiber matrix., Thermal Protection: All products offer excellent thermal-insulating properties and lower HVAC operating costs by reducing energy consumption. This saves natural resources and reduces emissions into the atmosphere., Water Repellency: The thermal properties of duct liner help control condensation, which helps improve indoor air quality by reducing unwanted moisture., Low Emitting: Certified by the GREENGUARD Environmental Institute., Low Air Resistance: The smooth ToughGard air stream surface offers low air resistance to deliver efficient HVAC system operation., Resists Microbial Growth: The air stream surface contains an EPA registered antimicrobial agent in order to reduce the potential of microbial growth that may affect this product. The antimicrobial properties are intended to only protect this product., Durable: The strength and resiliency of the ToughGard surface provides outstanding resistance against puncturing, tearing and other damage during fabrication, installation, and periodic system maintenance., Long-lasting and Non-corrosive: Inert fiber glass will not deteriorate or provide sustenance for vermin or rodents, and it will not corrode the sheet metal it insulates., Applicable Standards:, Model Building Codes: ICC, California Title 24, Material Standards: ASTM C1071, CAN/CGSB-51.11-92, Fire Safety Standards: NFPA 90A, NFPA 90B, Fire Hazard Classification:, UL 723, ASTM E84, NFPA 255, CAN/ULC-S102, Max. Flame Spread Index: 25, Max Smoke Developed Index: 50, Limited Combustible: NFPA 259 CERTAINTEED INSULATION 740377091279
L1331.jpg3/4" Self Adhesive Hanger
Locke Part #: L1331MFG Part #: LF-SP-0750
Description Ext.: 3/4" SELF ADHESIVE CAIN MFG. CO INC
L1961.jpg4" x 5’ Foil Sleeve R6
Locke Part #: L1266MFG Part #: 010 R-6 4"
Size: 4"x5’ r6, Description Ext.: 010 4" X 5’ FOIL SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg4" x 5’ Foil Sleeve R8
Locke Part #: L1961MFG Part #: 010 4"X5' R8 FOIL SLEEVE
Size: 4"x5’ r8, Description Ext.: 010 16" X 5’ R8 SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg5" x 5’ Foil Sleeve R6
Locke Part #: L1264MFG Part #: 010 R-6 5"
Size: 5"x5’ r6, Description Ext.: 010 5" X 5’ FOIL SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg5" x 5’ Foil Sleeve R8
Locke Part #: L1962MFG Part #: 010 R8 5" X 5'
Size: 5"x5’ r8, Description Ext.: 010 4" X 5’ R8 SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg6" x 5’ Foil Sleeve R6
Locke Part #: L1257MFG Part #: 010 R-6 6"
Size: 6"x5’ r6, Description Ext.: 010 6" X 5’ FOIL SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg6" x 5’ Foil Sleeve R8
Locke Part #: L1963MFG Part #: 010 R8 6" X 5'
Size: 6"x5’ r8, Description Ext.: 010 5" X 5’ R8 SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg7" x 5’ Foil Sleeve R6
Locke Part #: L1258MFG Part #: 010 R-6 7"
Size: 7"x5’ r6, Description Ext.: 010 7" X 5’ FOIL SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg7" x 5’ Foil Sleeve R8
Locke Part #: L1964MFG Part #: 010 R8 7" X 5'
Size: 7"x5’ r8, Description Ext.: 010 6" X 5’ R8 SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
T12290-48-125_1.jpg75# 3" x 48" x 50’ R-8.3 FSK SoftTouch Duct Wrap Insulation
Locke Part #: L0411MFG Part #: DR2R48X125 /2290-48-125
Size: 48" x 125’, Width (in): 48, Length (ft): 50, Sq Ft: 500, Thickness (in): 3, K-Value (Btu•in / h•ft²•°F): 0.31, K-Value (W / m•°C): 0.045, R-Value (h•ft²•°F / Btu): 9.6, R-Value (m²•°C / W): 1.69, Model Building Codes: ICC, Fire Safety Standards: NFPA 90A, NFPA 90B, Facing: FSK/PSK, Installed R-value (h•ft²•°F / btu): 8.3, Installed R-value (m²•°C / W): 1.41, Installed K-value (Btu•in / h•ft² •°F): 0.28, Installed K-value (W / m•°C): 0.041 Impervious to Mold, Insects and Rodents, Non-Carcinogenic, 97% Reflectivity of Radiant Heat, Water and Vapor Barriers, Tough, Compact, Lightweight and Clean, Tougher Fire Safety Rated NFPA 286 MITEX BUILDING PRODUCTS LLC
L1961.jpg8" x 5’ Foil Sleeve R6
Locke Part #: L1259MFG Part #: 010 R-6 8"
Size: 8"x5’ r6, Description Ext.: 010 8" X 5’ FOIL SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg8" x 5’ Foil Sleeve R8
Locke Part #: L1965MFG Part #: 010 R8 8" X 5'
Size: 8"x5’ r8, Description Ext.: 010 7" X 5’ R8 SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg9" x 5’ Foil Sleeve R6
Locke Part #: L1261MFG Part #: 010 R-6 9"
Size: 9"x5’ r6, Description Ext.: 010 9" X 5’ FOIL SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
L1961.jpg9" x 5’ Foil Sleeve R8
Locke Part #: L1966MFG Part #: 010 R8 9" X 5'
Size: 9"x5’ r8, Description Ext.: 010 8" X 5’ R8 SLEEVE UPC #010 Reinforced sleeves for insulating standard sheet metal pipes., Thick fiberglass insulation for excellent thermal efficiency, Reinforced metalized vapor barrier jacket. Atco Rubber Prod
Material: Carbon alloy steel, Temperature Range: 32°F to 250°F The Pincher permanently fastens insulation to sheet metal in the fabrication of ductwork., Driving the tapered teeth into the softer metal causes the point to take a permanent set., Fasteners withstand a tensile pull of 80-120 pounds in sheet metal., To properly attach Pinchers to sheet metal, a hardened steel backer must be used as work surface at all times., A pre-attached cap holds the liner firmly in place and prevents insulation from pulling loose or delaminating., Pinchers can be used in conjunction with adhesives on any galvanized sheet metal with lockforming qualities of 26 gauge and higher, Technical Data:, Hardness: Point, shank and head are heat treated and tempered in a controlled atmosphere to a hardness of Rockwell C-50., Corrosion Resistance: Cain Pinchers are plated with .0002" to .0003" of zinc and receive a separate dip for corrosion resistance., Retaining Cap: Retaining cap is sufficient in size and design to depress the surface of the insulation without tearing or cutting it. The cap does not protrude into the air stream to create noise or interfere with air movement in the duct., Vibrations: Pinchers will not fatigue or be physically affected by vibrations normally found in high velocity air handling systems., Environmentally Safe: When used as intended, the Pinchers are non-toxic and considered safe as defined by current Federal Standards. CAIN MFG. CO INC
L0587.jpgFiberglass
Locke Part #: L0587MFG Part #: 16503
Model: Fiberglass Features 1/2" thick Owens Corning yellow fiberglass insulation. Includes clear plastic wrap to provide moisture barrier. WRAP-ON CO INC 37841165032
L0588.jpgFiberglass
Locke Part #: L0588MFG Part #: 16506
Model: Fiberglass Features 1/2" thick Owens Corning yellow fiberglass insulation. Includes clear plastic wrap to provide moisture barrier. WRAP-ON CO INC 37841165063
linacoustic1.jpgLinacoustic RC 1/2 x 35-1/2 x 100 295.8 SF/RL
Locke Part #: L0509MFG Part #: 90005547
Width (in): 35.5, Length (ft): 100, Thickness (in): 1/2*, K-Value (Btu•in / h•ft²•°F): 0.24, K-Value (W / m•°C): 0.035, R-Value (h•ft²•°F / Btu): 2.1, R-Value (m²•°C / W): 0.37, Product Type: 200, Water Vapor Sorption: ASTM C1104 < 3% by weight, Corrosiveness: ASTM C665 Pass, Bacteria Resistance: ASTM G22 No Growth, Fungi Resistance: ASTM C1338 and ASTM G21 Pass; No Growth, Water Repellency Rating: INDA IST 80.6-92 > 4, Density: 2.0 pcf (32 kg/m3), C-Value (Btu / h•ft²•°F): 0.48, C-Value (W / m²•°C): 2.73, NRC: 0.45 Quiet Operation: ToughGard duct liner helps absorb equipment and air rush noises over a broad spectrum of sound. Noise is trapped and dissipated within the glass fiber matrix., Thermal Protection: All products offer excellent thermal-insulating properties and lower HVAC operating costs by reducing energy consumption. This saves natural resources and reduces emissions into the atmosphere., Water Repellency: The thermal properties of duct liner help control condensation, which helps improve indoor air quality by reducing unwanted moisture, Low Emitting: Certified by the GREENGUARD Environmental Institute., Low Air Resistance: The smooth ToughGard air stream surface offers low air resistance to deliver efficient HVAC system operation., Resists Microbial Growth: The air stream surface contains an EPA registered antimicrobial agent in order to reduce the potential of microbial growth that may affect this product. The antimicrobial properties are intended to only protect this product., Durable: The strength and resiliency of the ToughGard surface provides outstanding resistance against puncturing, tearing and other damage during fabrication, installation, and periodic system maintenance., Long-lasting and Non-corrosive: Inert fiber glass will not deteriorate or provide sustenance for vermin or rodents, and it will not corrode the sheet metal it insulates., Applicable Standards:, Model Building Codes:, Material Standards:, Fire Safety Standards:, Fire Hazard Classification:, Limited Combustible:, Physical/Chemical Properties:, Operating Limits:, Temperature:, Air Velocity:, ICC, California Title 24, ASTM C1071, Type I, CAN/CGSB-S1.11-92, NFPA 90A, NFPA 90B, UL 723, ASTM E84, NFPA 255, CAN/ULC-S102, Max. Flame Spread Index: 25, Max Smoke Developed Index: 50, NFPA 259 Johns Manville 662637066523
linacoustic1.jpgLinacoustic RC 1/2 x 47-1/2 x 100 395.8 SF/RL
Locke Part #: L3471MFG Part #: 90005552
Width (in): 47.5, Length (ft): 100, Thickness (in): 1/2*, K-Value (Btu•in / h•ft²•°F): 0.24, K-Value (W / m•°C): 0.035, R-Value (h•ft²•°F / Btu): 2.1, R-Value (m²•°C / W): 0.37, Product Type: 200, Water Vapor Sorption: ASTM C1104 < 3% by weight, Corrosiveness: ASTM C665 Pass, Bacteria Resistance: ASTM G22 No Growth, Fungi Resistance: ASTM C1338 and ASTM G21 Pass; No Growth, Water Repellency Rating: INDA IST 80.6-92 > 4, Density: 2.0 pcf (32 kg/m3), C-Value (Btu / h•ft²•°F): 0.48, C-Value (W / m²•°C): 2.73, NRC: 0.45 Quiet Operation: ToughGard duct liner helps absorb equipment and air rush noises over a broad spectrum of sound. Noise is trapped and dissipated within the glass fiber matrix., Thermal Protection: All products offer excellent thermal-insulating properties and lower HVAC operating costs by reducing energy consumption. This saves natural resources and reduces emissions into the atmosphere., Water Repellency: The thermal properties of duct liner help control condensation, which helps improve indoor air quality by reducing unwanted moisture, Low Emitting: Certified by the GREENGUARD Environmental Institute., Low Air Resistance: The smooth ToughGard air stream surface offers low air resistance to deliver efficient HVAC system operation., Resists Microbial Growth: The air stream surface contains an EPA registered antimicrobial agent in order to reduce the potential of microbial growth that may affect this product. The antimicrobial properties are intended to only protect this product., Durable: The strength and resiliency of the ToughGard surface provides outstanding resistance against puncturing, tearing and other damage during fabrication, installation, and periodic system maintenance., Long-lasting and Non-corrosive: Inert fiber glass will not deteriorate or provide sustenance for vermin or rodents, and it will not corrode the sheet metal it insulates., Applicable Standards:, Model Building Codes:, Material Standards:, Fire Safety Standards:, Fire Hazard Classification:, Limited Combustible:, Physical/Chemical Properties:, Operating Limits:, Temperature:, Air Velocity:, ICC, California Title 24, ASTM C1071, Type I, CAN/CGSB-S1.11-92, NFPA 90A, NFPA 90B, UL 723, ASTM E84, NFPA 255, CAN/ULC-S102, Max. Flame Spread Index: 25, Max Smoke Developed Index: 50, NFPA 259 Johns Manville 662637258379
linacoustic1.jpgLinacoustic RC 1/2 x 59-1/2 x 100 495.8 SF/RL
Locke Part #: L3463MFG Part #: 90005562
Johns Manville 662637258416
linacoustic1.jpgLinacoustic RC 1 x 35-1/2 x 100 295.8 SF/RL
Locke Part #: L0420MFG Part #: 90005499
Width (in): 35.5, Length (ft): 100, Thickness (in): 1, K-Value (Btu•in / h•ft²•°F): 0.24, K-Value (W / m•°C): 0.035, R-Value (h•ft²•°F / Btu): 4.2, R-Value (m²•°C / W): 0.73, Product Type: 150, Water Vapor Sorption: ASTM C1104 < 3% by weight, Corrosiveness: ASTM C665 Pass, Bacteria Resistance: ASTM G22 No Growth, Fungi Resistance: ASTM C1338 and ASTM G21 Pass; No Growth, Water Repellency Rating: INDA IST 80.6-92 > 4, Density: 1.5 pcf (24 kg/m2), C-Value (Btu / h•ft²•°F): 0.24, C-Value (W / m²•°C): 1.36, NRC: 0.70 Quiet Operation: ToughGard duct liner helps absorb equipment and air rush noises over a broad spectrum of sound. Noise is trapped and dissipated within the glass fiber matrix., Thermal Protection: All products offer excellent thermal-insulating properties and lower HVAC operating costs by reducing energy consumption. This saves natural resources and reduces emissions into the atmosphere., Water Repellency: The thermal properties of duct liner help control condensation, which helps improve indoor air quality by reducing unwanted moisture, Low Emitting: Certified by the GREENGUARD Environmental Institute., Low Air Resistance: The smooth ToughGard air stream surface offers low air resistance to deliver efficient HVAC system operation., Resists Microbial Growth: The air stream surface contains an EPA registered antimicrobial agent in order to reduce the potential of microbial growth that may affect this product. The antimicrobial properties are intended to only protect this product., Durable: The strength and resiliency of the ToughGard surface provides outstanding resistance against puncturing, tearing and other damage during fabrication, installation, and periodic system maintenance., Long-lasting and Non-corrosive: Inert fiber glass will not deteriorate or provide sustenance for vermin or rodents, and it will not corrode the sheet metal it insulates., Applicable Standards:, Model Building Codes:, Material Standards:, Fire Safety Standards:, Fire Hazard Classification:, Limited Combustible:, Physical/Chemical Properties:, Operating Limits:, Temperature:, Air Velocity:, ICC, California Title 24, ASTM C1071, Type I, CAN/CGSB-S1.11-92, NFPA 90A, NFPA 90B, UL 723, ASTM E84, NFPA 255, CAN/ULC-S102, Max. Flame Spread Index: 25, Max Smoke Developed Index: 50, NFPA 259 Johns Manville 662637066585
linacoustic1.jpgLinacoustic RC 1 x 47-1/2 x 100 395.8 SF/RL
Locke Part #: L3469MFG Part #: 90005512
Size: 1" X 47-1/2" X 100’, Finish: Glass Mat + Coating, Width: 47.5000 Inches, Height: 1.0000 Inches, Length: 100.0000 Feet, Standards: ASTM C1071, Odor: Mild resin odor, Specific Gravity: Variable, Melting Point: >704°F, Temperature Range: 40°F to 250°F, Water Vapor Sorption: Fibrous Glass Blankets or Boards with Glass Mat Facing or Coating with Glass Mat Facing, Physical State: Solid, Applications: Duct Liner, Acoustical, Approvals: R3711, Certifications: GreenGuard, Composition: Fiber glass, Noise Reduction Coefficient: 0.7, Resistances: C= 0.24, R-Value: R4.2, Thickness: 1", Tier: Linacoustic Rc Johns Manville Linacoustic RC duct liner provides superior thermal and acoustical performance and improved handling during fabrication when lining metal ducts, Linacoustic RC's airstream surface is coated with our proprietary Permacote coating, which provides a durable surface that is resistant to dust and dirt and provides added product protection against microbial growth, Our unique flame-attenuated technology yields a very controlled fine fiber characteristic that results in a fiber glass core unmatched by our competitors, This ensures consistently high performance and easy processing on a wide range of duct fabrication equipment, Building occupants benefit from less unwanted noise and more consistent temperatures for improved comfort Johns Manville 662637258447
linacoustic1.jpgLinacoustic RC 1 x 59-1/2 x 100 495.8 SF/RL
Locke Part #: L3477MFG Part #: 90005534
Johns Manville 662637258492
linacoustic1.jpgLinacoustic RC 2 x 47-1/2 x 50 197.9 SF/RL
Locke Part #: L0423MFG Part #: 90005605
Width (in): 47.5, Length (ft): 100, Thickness (in): 2, K-Value (Btu•in / h•ft²•°F): 0.24, K-Value (W / m•°C): 0.035, R-Value (h•ft²•°F / Btu): 8.3, R-Value (m²•°C / W): 1.47, Product Type: 150, Water Vapor Sorption: ASTM C1104 < 3% by weight, Corrosiveness: ASTM C665 Pass, Bacteria Resistance: ASTM G22 No Growth, Fungi Resistance: ASTM C1338 and ASTM G21 Pass; No Growth, Water Repellency Rating: INDA IST 80.6-92 > 4, Density: 1.5 pcf (24 kg/m2), C-Value (Btu / h•ft²•°F): 0.12, C-Value (W / m²•°C): 0.68, NRC: 0.90 Quiet Operation: ToughGard duct liner helps absorb equipment and air rush noises over a broad spectrum of sound. Noise is trapped and dissipated within the glass fiber matrix., Thermal Protection: All products offer excellent thermal-insulating properties and lower HVAC operating costs by reducing energy consumption. This saves natural resources and reduces emissions into the atmosphere., Water Repellency: The thermal properties of duct liner help control condensation, which helps improve indoor air quality by reducing unwanted moisture, Low Emitting: Certified by the GREENGUARD Environmental Institute., Low Air Resistance: The smooth ToughGard air stream surface offers low air resistance to deliver efficient HVAC system operation., Resists Microbial Growth: The air stream surface contains an EPA registered antimicrobial agent in order to reduce the potential of microbial growth that may affect this product. The antimicrobial properties are intended to only protect this product., Durable: The strength and resiliency of the ToughGard surface provides outstanding resistance against puncturing, tearing and other damage during fabrication, installation, and periodic system maintenance., Long-lasting and Non-corrosive: Inert fiber glass will not deteriorate or provide sustenance for vermin or rodents, and it will not corrode the sheet metal it insulates., Applicable Standards:, Model Building Codes:, Material Standards:, Fire Safety Standards:, Fire Hazard Classification:, Limited Combustible:, Physical/Chemical Properties:, Operating Limits:, Temperature:, Air Velocity:, ICC, California Title 24, ASTM C1071, Type I, CAN/CGSB-S1.11-92, NFPA 90A, NFPA 90B, UL 723, ASTM E84, NFPA 255, CAN/ULC-S102, Max. Flame Spread Index: 25, Max Smoke Developed Index: 50, NFPA 259 Johns Manville 662637264202
L511.jpgMagnetic Hammer
Locke Part #: L0511MFG Part #: EQCPH-1
Description Ext.: MAGNETIC HAMMER For setting pinchers thru insulation., 2lb. CAIN MFG. CO INC
Size: 2-1/3" X 48" X 75, Width: 48.0000 Inches, Height: 2.3330 Inches, Length: 75.0000 Feet, Standards: ASTM C1290, Appearance: Fibrous glass Blanket, Specific Gravity: Variable, Melting Point: >704°F, Temperature Range: 40°F to 250°F, Physical State: Solid, Applications: Fiber Glass Duct Wrap, FSK-Faced, Approvals: UL File R3711, Resistances: k = 0.27, R-Value: R6.5, Thickness: 2.33", Tier: Microlite Eq Johns Manville Microlite EQ Formaldehyde-free duct wrap insulation is a lightweight, blanket-type insulation with an FSK facing for superior thermal and condensation control, It is recommended for HVAC ducts or surfaces where design parameters prohibit the use of a board product. Installing contractors prefer Microlite EQ's bio-based binder for many reasons including improved handling, easier cutting and less dust, Our manufacturing process ensures consistency during production, which results in consistent product quality, Microlite EQ insulation is recommended as thermal insulation for the exterior of HVAC systems or other spaces or surfaces where temperature control is required Johns Manville
microlite1.jpgMicrolite VINYL 1-1/2 x 48 x 100 400.0 SF/PKG
Locke Part #: L0474MFG Part #: 90006301
Johns Manville 662637270111
microlite1.jpgMicrolite VINYL 2 x 48 x 75 300.0 SF/PKG
Locke Part #: L0476MFG Part #: 90006303
Johns Manville 662637270128