Loading ...

Search in: Commercial Category

ALLIED AIR COMMERCIAL
Standard Features, Aluminized Steel Heat Exchanger With Inshot Burners - Life cycle tested., R-410A Refrigerant - Environmentally friendly, High Pressure Switches - Protect compressor., Scroll Compressors - Single speed scroll compressors are furnished on all models., Isolated Compressor Compartment - Allows performance check during normal compressor operation without disrupting airflow., Thermostatic Expansion Valves Provide peak cooling performance across the entire application range., MERV 8 or MERV 13 Filters - Available as field installed option, provide an enhanced level of indoor air quality, and can help the building qualify for additional LEED credits., Heating System, Aluminized steel inshot burners, direct spark ignition, electronic flame sensor, combustion air inducer, redundant automatic dual stage gas valve with manual shutoff., Heat Exchanger Tubular construction, aluminized steel, life cycle tested. Optional Stainless Steel Heat Exchanger is required if mixed air temperature is below 45 F., Watchguard circuit on module automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance service calls., Ignition control is factory installed in the controls section., Factory installed, limit control with fixed temperature setting. Heat limit control protects heat exchanger and other components from overheating., Flame roll-out switch, flame sensor and combustion air inducer proving switch protect system operation., Cooling System, Designed to maximize sensible and latent cooling performance at design conditions., System can operate from 30 F to 125 F without any additional controls., R-410A Refrigerant is Non-chlorine based, ozone friendly., Scroll compressors on all models for high performance, reliability and quiet operation., Resiliently mounted on rubber grommets for quiet operation., Thermal Expansion Valves Assures optimal performance throughout the application range., High Pressure Switch Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation., Freezestats Protect the evaporator coil from damaging ice build-up due to conditions such as low/no airflow, or low refrigerant charge. ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
Product Image Not Available 14W33 15KW 1PH HT STRIP
Locke Part #: L4364 MFG Part #: 14W33
ALLIED AIR COMMERCIAL
Product Image Not Available 15 kW Heat Strip for KHA, KCA
Locke Part #: L4310 MFG Part #: 14W36
ALLIED AIR COMMERCIAL
RSI's 510 SERIES concentric diffuser systems are designed to provide a single point air distribution system. The systems may be used with either a T-Bar ceiling or a plaster ceiling., Standard features include:, 1., All Aluminum diffuser with aluminum return air egg crate., 2., Built-in Anti-Sweat gasket., 3., Molded Fiberglass Transition (through five tons)., 4., Built-in hanging supports., 5., Diffuser box constructed of fiberglass duct board (through 7.5 tons) or sheet metal., Standard benefits include:, 1., Even four way airflow., 2., Factory assembled & sealed., 3., Guaranteed not to "sweat"., 4., Guaranteed not to recirculate air flow (short cycle)., 5., Return air egg crate is easily removed., 6., Units are fully insulated (both supply and return). RRS ROOFTOP SYSTEMS
Product Image Not Available 18" Height Downflow Hybrid Roof Curbs
Locke Part #: L9646 MFG Part #: 10Z26
ALLIED AIR COMMERCIAL
RSI's 510 SERIES concentric diffuser systems are designed to provide a single point air distribution system. The systems may be used with either a T-Bar ceiling or a plaster ceiling., Standard features include:, 1., All Aluminum diffuser with aluminum return air egg crate., 2., Built-in Anti-Sweat gasket., 3., Molded Fiberglass Transition (through five tons)., 4., Built-in hanging supports., 5., Diffuser box constructed of fiberglass duct board (through 7.5 tons) or sheet metal., Standard benefits include:, 1., Even four way airflow., 2., Factory assembled & sealed., 3., Guaranteed not to "sweat"., 4., Guaranteed not to recirculate air flow (short cycle)., 5., Return air egg crate is easily removed., 6., Units are fully insulated (both supply and return). RRS ROOFTOP SYSTEMS
RSI's 510 SERIES concentric diffuser systems are designed to provide a single point air distribution system. The systems may be used with either a T-Bar ceiling or a plaster ceiling., Standard features include:, 1., All Aluminum diffuser with aluminum return air egg crate., 2., Built-in Anti-Sweat gasket., 3., Molded Fiberglass Transition (through five tons)., 4., Built-in hanging supports., 5., Diffuser box constructed of fiberglass duct board (through 7.5 tons) or sheet metal., Standard benefits include:, 1., Even four way airflow., 2., Factory assembled & sealed., 3., Guaranteed not to "sweat"., 4., Guaranteed not to recirculate air flow (short cycle)., 5., Return air egg crate is easily removed., 6., Units are fully insulated (both supply and return). RRS ROOFTOP SYSTEMS
Product Image Not Available 22.5 kW Heat Strip for KHA, KCA
Locke Part #: L4311 MFG Part #: 14W37
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
Approvals, AHRI Certified to AHRI Standard 210/240-2008. CSA listed, Units are Certified by CSA., Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National and Canadian Electrical Codes., All models are ASHRAE 90.1 compliant., ISO 9001 Registered Manufacturing Quality System., Cooling System, Designed to maximize sensible and latent cooling performance at design conditions., System can operate from 35 F to 125 F without any additional controls., R-410a Refrigerant, Non-chlorine, ozone friendly, R-410A., Unit is factory pre-charged with refrigerant. See Specifications Table., compressor, Resiliently mounted on rubber grommets for quiet operation., Scroll compressors for high performance, reliability and quiet operation., High Pressure Switch, Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation., Filter/Drier, High capacity filter/drier protects the system from dirt and moisture., Eco-last Coil System, Condenser coil features lightweight, all aluminum brazed fin construction., Constructed of three components: a flat extrusion tube, fins in-between the flat extrusion tube and two refrigerant manifolds., Evaporator Coil, Condensate Drain pan, Plastic pan, sloped to meet drainage requirements of ASHRAE 62.1., End drain connection., Outdoor Coil Fan Motor, Thermal overload protected, totally enclosed, permanently lubricated bearings, shaft down, fan guard mount., Outdoor Coil Fan Guard, PVC coated fan guard furnished., Cabinet, Heavy-gauge steel panels and full perimeter heavy gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation., Warranty, Limited five years on compressors, Limited three years on the Eco-last Coil System., Limited one year all other covered components. ALLIED AIR COMMERCIAL
Approvals, AHRI Certified to AHRI Standard 210/240-2008. CSA listed, Units are Certified by CSA., Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National and Canadian Electrical Codes., All models are ASHRAE 90.1 compliant., ISO 9001 Registered Manufacturing Quality System., Cooling System, Designed to maximize sensible and latent cooling performance at design conditions., System can operate from 35 F to 125 F without any additional controls., R-410a Refrigerant, Non-chlorine, ozone friendly, R-410A., Unit is factory pre-charged with refrigerant. See Specifications Table., compressor, Resiliently mounted on rubber grommets for quiet operation., Scroll compressors for high performance, reliability and quiet operation., High Pressure Switch, Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation., Filter/Drier, High capacity filter/drier protects the system from dirt and moisture., Eco-last Coil System, Condenser coil features lightweight, all aluminum brazed fin construction., Constructed of three components: a flat extrusion tube, fins in-between the flat extrusion tube and two refrigerant manifolds., Evaporator Coil, Condensate Drain pan, Plastic pan, sloped to meet drainage requirements of ASHRAE 62.1., End drain connection., Outdoor Coil Fan Motor, Thermal overload protected, totally enclosed, permanently lubricated bearings, shaft down, fan guard mount., Outdoor Coil Fan Guard, PVC coated fan guard furnished., Cabinet, Heavy-gauge steel panels and full perimeter heavy gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation., Warranty, Limited five years on compressors, Limited three years on the Eco-last Coil System., Limited one year all other covered components. ALLIED AIR COMMERCIAL
COOLING / HEATING SYSTEM, Designed to maximize sensible and latent cooling performance at design conditions., System can operate from 35 F to 125 F without any additional controls., R-410A Refrigerant, Non-chlorine, ozone friendly, R-410A., Unit is factory pre-charged with refrigerant. See Specifications Table., Compressor, Resiliently mounted on rubber grommets for quiet operation., Scroll compressors for high performance, reliability and quiet operation., Compressor Crankcase Heater, Protects against refrigerant migration that can occur during low ambient operation., High pressure Switch, Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation., Reversing Valve, 4-way interchange reversing valve effects a rapid change in direction of refrigerant flow resulting in quick changeover from cooling to heating and vice versa., Defrost Control, Provides a defrost cycle, if needed, every 30 or 60 or 90 minutes (adjustable) of compressor on time at outdoor coil temperature below 35 F. Temperature switch mounted on outdoor coil liquid line terminates defrost cycle., Filter/Drier, High capacity filter/drier protects the system from dirt and moisture., Coil Construction, Copper tube construction, enhanced rippled-edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer. Factory leak tested., Indoor Coil, Cross row circuiting with rifled tubing optimizes both sensible and latent cooling capacity., Condensate Drain pan, Plastic pan, sloped to meet drainage requirements of ASHRAE 62.1., End drain connection., Outdoor Coil Fan Motor, Thermal overload protected, totally enclosed, permanently lubricated bearings, shaft down, fan guard mount., Outdoor Coil Fan Guard, PVC coated fan guard furnished., CABINET, Heavy-gauge steel panels and full perimeter heavy gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation., WARRANTY, Limited five years on compressors., Limited one year all other covered components., APPROVALS, AHRI Certified to AHRI Standard 210/240-2008., CSA listed., Units are Certified by CSA., Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National and Canadian Electrical Codes., All models are ASHRAE 90.1 compliant., ISO 9001 Registered Manufacturing Quality System. ALLIED AIR COMMERCIAL
COOLING / HEATING SYSTEM, Designed to maximize sensible and latent cooling performance at design conditions. System can operate from 30 F to 125 F without any additional controls., Refrigerant, Non-chlorine, ozone friendly R-410A. Unit pre-charged with refrigerant., Compressor, Scroll compressors resiliently mounted on rubber grommets for high performance, reliability and quiet operation., Compressor Crankcase Heater, Protects against refrigerant migration that can occur during low ambient operation., High Pressure Switch Check/Thermal Expansion Valves Reversing Valves, 4-way interchange reversing valve effects a rapid change in direction of refrigerant flow resulting in quick changeover., Defrost Control, Provides a defrost cycle, if needed, every 30 or 60 or 90 minutes (adjustable)., Filter/Drier Freezestat, Protects the evaporator coil from damaging ice build-up., Coil Construction, Copper tube construction, enhanced rippled-edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer. Factory leak tested. Indoor Coil Cross row circuiting with rifled copper tubing., Outdoor Coil, Two independent formed coils allow separation for cleaning., Condensate Drain Pan, Plastic pan, sloped to meet drainage requirements of ASHRAE 62.1. Side or bottom drain connections. Reversible., Outdoor Coil Fan Motor, Thermal overload protected, totally enclosed, shaft up, wire basket mount. Outdoor Coil Fan PVC coated fan guard furnished., CABINET, Construction, Heavy-gauge galvanized steel panels with a two-layer enamel paint finish and full perimeter heavy-gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation., Air-Flow Choice, Units are shipped in down-flow (vertical) configuration, can be field converted to horizontal air flow configuration without a kit., Power Entry, Through the base or horizontal knock- outs., Insulation, All panels adjacent to conditioned air are fully insulated with non-hygroscopic fiberglass insulation. Base is fully insulated., CONTROLS, Unit Control, All control voltage is provided via a 24V (secondary) transformer with built-in circuit breaker protection., Heat/Cool Staging, - Capable of up to 2 heat / 2 cool staging with a third party DDC control system or thermostat., Low Voltage Terminal Block, - Provides screw terminal connections for thermostat or controller wiring. Night Setback Mode - Saves energy by closing outdoor air dampers and operating supply fan on thermostat demand only., BLOWER, A wide selection of supply air blower options are available to meet a variety of air flow requirements., Motor, Supply Air Blower, Forward curved blades, blower wheel is statically and dynamically balanced. All belt drive motors have adjustable pulley for speed change., Indoor Air Quality -, Disposable 2 inch air filters furnished., Net Cooling Capacity 47,000 to 59,000 Btuh, Net Heating Capacity 48,000 to 60,500 Btuh, Optional Electric Heat 7.5 to 30 kW ALLIED AIR COMMERCIAL
APPLICATIONS, Convertible upflow or horizontal design., Each refrigerant circuit has a dedicated expansion valve., Dual distribution system for two stage capacity control during cooling cycles., Air handlers are shipped factory assembled ready to install. Standard static blower drive is furnished factory installed., REFRIGERANT SYSTEM, Multi-Circuit, Copper Tube Coil, Coils on 090-120 models are face split with separate circuits, each circuit has its own expansion valve., Coil is constructed of aluminum fins fitted to durable seamless, rifled copper tubes., Flared tubing connections and silver soldering provide tight, leakproof joints., Refrigerant Piping and Drain Connections, Refrigerant line inlets (knockouts) are provided on both sides of the cabinet., Refrigerant lines require sweat connections and are made internal to the cabinet., Condensate drain outlet extends outside the cabinet for ease of connection. Condensate drain can be relocated and repositioned., BELT DRIVE BLOWERS, Single blower wheel., Centrifugal belt driven blowers deliver large air volumes quietly and with low power consumption., Heavy-duty blower wheels, with forward curved blades and double inlet are statically and dynamically balanced., Heavy-duty bearings are permanently sealed and lubricated., CABINET, Cabinet is constructed of heavy-gauge, galvanized steel completely lined with thick fiberglass insulation for quiet and efficient operation., Drain Pan, Deep, corrosion resistant plastic drain pan. ALLIED AIR COMMERCIAL
45W69 TAA120S4DG 10TAH 460V R410A
Locke Part #: L4340 MFG Part #: 45W69
APPLICATIONS, Convertible upflow or horizontal design., Each refrigerant circuit has a dedicated expansion valve., Dual distribution system for two stage capacity control during cooling cycles., Air handlers are shipped factory assembled ready to install. Standard static blower drive is furnished factory installed., REFRIGERANT SYSTEM, Multi-Circuit, Copper Tube Coil, Coils on 090-120 models are face split with separate circuits, each circuit has its own expansion valve., Coil is constructed of aluminum fins fitted to durable seamless, rifled copper tubes., Flared tubing connections and silver soldering provide tight, leakproof joints., Refrigerant Piping and Drain Connections, Refrigerant line inlets (knockouts) are provided on both sides of the cabinet., Refrigerant lines require sweat connections and are made internal to the cabinet., Condensate drain outlet extends outside the cabinet for ease of connection. Condensate drain can be relocated and repositioned., BELT DRIVE BLOWERS, Single blower wheel., Centrifugal belt driven blowers deliver large air volumes quietly and with low power consumption., Heavy-duty blower wheels, with forward curved blades and double inlet are statically and dynamically balanced., Heavy-duty bearings are permanently sealed and lubricated., CABINET, Cabinet is constructed of heavy-gauge, galvanized steel completely lined with thick fiberglass insulation for quiet and efficient operation., Drain Pan, Deep, corrosion resistant plastic drain pan. ALLIED AIR COMMERCIAL
Product Image Not Available 46W51 15KW HT STRP 208/230V
Locke Part #: L4341 MFG Part #: 46W51
ALLIED AIR COMMERCIAL
COOLING / HEATING SYSTEM, Designed to maximize sensible and latent cooling performance at design conditions., System can operate from 35 F to 125 F without any additional controls., R-410A Refrigerant, Non-chlorine, ozone friendly, R-410A., Unit is factory pre-charged with refrigerant. See Specifications Table., Compressor, Resiliently mounted on rubber grommets for quiet operation., Scroll compressors for high performance, reliability and quiet operation., Compressor Crankcase Heater, Protects against refrigerant migration that can occur during low ambient operation., High pressure Switch, Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation., Reversing Valve, 4-way interchange reversing valve effects a rapid change in direction of refrigerant flow resulting in quick changeover from cooling to heating and vice versa., Defrost Control, Provides a defrost cycle, if needed, every 30 or 60 or 90 minutes (adjustable) of compressor on time at outdoor coil temperature below 35 F. Temperature switch mounted on outdoor coil liquid line terminates defrost cycle., Filter/Drier, High capacity filter/drier protects the system from dirt and moisture., Coil Construction, Copper tube construction, enhanced rippled-edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer. Factory leak tested., Indoor Coil, Cross row circuiting with rifled tubing optimizes both sensible and latent cooling capacity., Condensate Drain pan, Plastic pan, sloped to meet drainage requirements of ASHRAE 62.1., End drain connection., Outdoor Coil Fan Motor, Thermal overload protected, totally enclosed, permanently lubricated bearings, shaft down, fan guard mount., Outdoor Coil Fan Guard, PVC coated fan guard furnished., CABINET, Heavy-gauge steel panels and full perimeter heavy gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation., WARRANTY, Limited five years on compressors., Limited one year all other covered components., APPROVALS, AHRI Certified to AHRI Standard 210/240-2008., CSA listed., Units are Certified by CSA., Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National and Canadian Electrical Codes., All models are ASHRAE 90.1 compliant., ISO 9001 Registered Manufacturing Quality System. ALLIED AIR COMMERCIAL
Product Image Not Available 53W94 30KW 460V 3PH STRIP HEAT
Locke Part #: L4373 MFG Part #: 53W94
ALLIED AIR COMMERCIAL
Approvals, ETL and CSA listed, Efficiency rating verified by GAMA, Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National Electrical Codes., All models are certified in accordance with the ULE certification program, which is based on AHRI Standard 340/360- 2007., All models are ASHRAE 90.1-2007 compliant., ISO 9001 Registered Manufacturing Quality System., Heating System, Optional Factory or Field Installed, Helix wound nichrome elements, Individual element limit controls, Wiring harness, Unit fuse block is furnished as standard, Cooling System, Designed to maximize sensible and latent cooling performance at design conditions., System can operate from 30 F to 125 F without any additional controls., R-410A Refrigerant is Non-chlorine based, ozone friendly., Scroll compressors on all models for high performance, reliability and quiet operation., Resiliently mounted on rubber grommets for quiet operation., Thermal Expansion Valves Assures optimal performance throughout the application range., High Pressure Switch Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation., Freezestats Protect the evaporator coil from damaging ice build-up due to conditions such as low/no airflow, or low refrigerant charge., Copper tube Coil construction, enhanced rippled edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer. Factory leak tested., Evaporator Coil Cross row circuiting with rifled copper tubing optimizes both sensible and latent cooling capacity., Single formed Condenser coil., Plastic Condensate Drain Pan, sloped to meet drainage requirements of ASHRAE 62.1., Side or bottom drain connections., Reversible to allow connection at back of unit., Outdoor Coil Fan Motors Thermal overload protected, totally enclosed, permanently lubricated ball bearings, shaft up, wire basket mount., Outdoor Coil Fans PVC coated fan guard furnished., Cabinet, Heavy-gauge steel panels and full perimeter heavy-gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation., Base rails have rigging holes., Three sides of the base rail have forklift slots., Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building., Units are shipped in downflow (vertical) configuration, can be field converted to horizontal airflow with optional Horizontal Discharge Kit., All panels adjacent to conditioned air are fully insulated with nonhygroscopic fiberglass insulation., Unit base is fully insulated. The insulation also serves as an air seal to the roof curb, eliminating the need to add a seal during installation. ALLIED AIR COMMERCIAL
Standard Features, Aluminized Steel Heat Exchanger With Inshot Burners - Life cycle tested., R-410A Refrigerant - Environmentally friendly, High Pressure Switches - Protect compressor., Scroll Compressors - Single speed scroll compressors are furnished on all models., Isolated Compressor Compartment - Allows performance check during normal compressor operation without disrupting airflow., Thermostatic Expansion Valves Provide peak cooling performance across the entire application range., MERV 8 or MERV 13 Filters - Available as field installed option, provide an enhanced level of indoor air quality, and can help the building qualify for additional LEED credits., Heating System, Aluminized steel inshot burners, direct spark ignition, electronic flame sensor, combustion air inducer, redundant automatic dual stage gas valve with manual shutoff., Heat Exchanger Tubular construction, aluminized steel, life cycle tested. Optional Stainless Steel Heat Exchanger is required if mixed air temperature is below 45 F., Watchguard circuit on module automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance service calls., Ignition control is factory installed in the controls section., Factory installed, limit control with fixed temperature setting. Heat limit control protects heat exchanger and other components from overheating., Flame roll-out switch, flame sensor and combustion air inducer proving switch protect system operation., Cooling System, Designed to maximize sensible and latent cooling performance at design conditions., System can operate from 30 F to 125 F without any additional controls., R-410A Refrigerant is Non-chlorine based, ozone friendly., Scroll compressors on all models for high performance, reliability and quiet operation., Resiliently mounted on rubber grommets for quiet operation., Thermal Expansion Valves Assures optimal performance throughout the application range., High Pressure Switch Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation., Freezestats Protect the evaporator coil from damaging ice build-up due to conditions such as low/no airflow, or low refrigerant charge. ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
Product Image Not Available For 10 Ton KG-KC-KH Package Units
Locke Part #: L4117 MFG Part #: 12X66
ALLIED AIR COMMERCIAL
Product Image Not Available For 2-6 Ton KG-KC-KH Package Units
Locke Part #: L4344 MFG Part #: 41W33
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
Product Image Not Available Hail Guard for 7-1/2 - 10 Ton KH
Locke Part #: L4408 MFG Part #: 13T24
ALLIED AIR COMMERCIAL
Product Image Not Available Hail Guard for TSA 072 & 090
Locke Part #: L4494 MFG Part #: 13T29
ALLIED AIR COMMERCIAL
Product Image Not Available Hail Guard for TSA 120
Locke Part #: L4495 MFG Part #: 13T30
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
Product Image Not Available Horizontal Conversion Kit for TGA180
Locke Part #: L4116 MFG Part #: 87M00
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
Product Image Not Available LGA/TGA to KGA Adapter
Locke Part #: L4475 MFG Part #: 54W96
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
Heating System, Aluminized steel inshot burners, direct spark ignition, electronic flame sensor, combustion air inducer, redundant automatic dual stage gas valve with manual shut-off., Heat Exchanger :, Tubular construction, aluminized steel, life cycle tested., Electronic Pilot Ignition, Watchguard circuit on module automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance service calls., Limit Control:, Factory installed, limit control with fixed temperature setting. Heat limit control protects heat exchanger and other components from overheating., Safety Switches:, Flame roll-out switch, flame sensor and combustion air inducer proving switch protect system operation., Cooling System, Designed to maximize sensible and latent cooling performance at design conditions., System can operate from 30 F to 125 F without any additional controls., R-410A Refrigerant:, Non-chlorine based, ozone friendly, R-410A., High Pressure Switches, Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation., Filter/Driers:, High capacity filter/drier protects the system from dirt and moisture., Eco-last Coil System, Condenser coil features lightweight, all aluminum brazed fin construction., Constructed of three components: a flat extrusion tube, fins in-between the flat extrusion tube and two refrigerant manifolds., Evaporator Coil:, Copper tube construction, enhanced rippled-edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer., Condensate Drain Pan:, Plastic pan, sloped to meet drainage requirements of ASHRAE 62.1, Side drain connections., Outdoor Coil Fan Motors, Thermal overload protected, totally enclosed, permanently lubricated ball bearings, shaft up, wire basket mount., Outdoor Coil Fans:, PVC coated fan guard furnished., Cabinet, Construction, Heavy-gauge steel panels and full perimeter heavy-gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation., Warranty, Limited ten years aluminized heat exchanger, limited fifteen years optional stainless steel heat exchanger, Limited five years on compressors, Limited three years on the Eco-last Coil System., Limited one year all other covered components., Approvals, AHRI Certified to AHRI Standard 340/360-2007, Units are ETL listed., Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National and Canadian Electrical Codes. ALLIED AIR COMMERCIAL
Heating System, Aluminized steel inshot burners, direct spark ignition, electronic flame sensor, combustion air inducer, redundant automatic dual stage gas valve with manual shut-off., Heat Exchanger :, Tubular construction, aluminized steel, life cycle tested., Electronic Pilot Ignition, Watchguard circuit on module automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance service calls., Limit Control:, Factory installed, limit control with fixed temperature setting. Heat limit control protects heat exchanger and other components from overheating., Safety Switches:, Flame roll-out switch, flame sensor and combustion air inducer proving switch protect system operation., Cooling System, Designed to maximize sensible and latent cooling performance at design conditions., System can operate from 30 F to 125 F without any additional controls., R-410A Refrigerant:, Non-chlorine based, ozone friendly, R-410A., High Pressure Switches, Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation., Filter/Driers:, High capacity filter/drier protects the system from dirt and moisture., Eco-last Coil System, Condenser coil features lightweight, all aluminum brazed fin construction., Constructed of three components: a flat extrusion tube, fins in-between the flat extrusion tube and two refrigerant manifolds., Evaporator Coil:, Copper tube construction, enhanced rippled-edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer., Condensate Drain Pan:, Plastic pan, sloped to meet drainage requirements of ASHRAE 62.1, Side drain connections., Outdoor Coil Fan Motors, Thermal overload protected, totally enclosed, permanently lubricated ball bearings, shaft up, wire basket mount., Outdoor Coil Fans:, PVC coated fan guard furnished., Cabinet, Construction, Heavy-gauge steel panels and full perimeter heavy-gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation., Warranty, Limited ten years aluminized heat exchanger, limited fifteen years optional stainless steel heat exchanger, Limited five years on compressors, Limited three years on the Eco-last Coil System., Limited one year all other covered components., Approvals, AHRI Certified to AHRI Standard 340/360-2007, Units are ETL listed., Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National and Canadian Electrical Codes. ALLIED AIR COMMERCIAL
R-410A Refrigerant - Environmentally friendly., Scroll Compressors - Single speed scroll compressors are furnished on all models., Eco-last Coil System (All KGB Models and KGA072 and 090 Models) - Smaller, lighter condenser coil with improved heat transfer, High Pressure Switches - Protect compressor., Isolated Compressor Compartment - Allows performance check during normal compressor operation without disrupting airflow., Direct or Belt Drive Blower Motors - Direct drive (024, 030, 036, 048 and 060 models). Belt drive motors (036, 048, 060, 072 and 090 models) to maximize air performance., Independent Motor Mounts - Allows for easy and efficient service access without removing the top panel, Downflow or Horizontal Airflow - Easy field conversion., Two Fork Lift Slots on Three Sides - Easy to pick up and transport units from almost any angle., Corrosion-Resistant Removable, Reversible Drain Pan - Provides application flexibility, durability and improved serviceability., Thermostatic Expansion Valves (All KGB Models and KGA036, 048 and 060 Models) - Provide peak cooling performance across the entire application range. ALLIED AIR COMMERCIAL
R-410A Refrigerant - Environmentally friendly., Scroll Compressors - Single speed scroll compressors are furnished on all models., Eco-last Coil System (All KCB Models and KCA072 and 090 Models) - Smaller, lighter condenser coil with improved heat transfer, High Pressure Switches - Protect compressor., Isolated Compressor Compartment - Allows performance check during normal compressor operation without disrupting airflow., Direct or Belt Drive Blower Motors - Direct drive (024, 030, 036, 048 and 060 models). Belt drive motors (036, 048, 060, 072 and 090 models) to maximize air performance., Independent Motor Mounts - Allows for easy and efficient service access without removing the top panel. Downflow or Horizontal Airflow - Easy field conversion., Two Fork Lift Slots on Three Sides - Easy to pick up and transport units from almost any angle. Corrosion-Resistant Removable, Reversible Drain Pan - Provides application flexibility, durability and improved serviceability., Thermostatic Expansion Valves (All KCB Models and KCA036, 048 and 060 Models) - Provide peak cooling performance across the entire application range. ALLIED AIR COMMERCIAL
R-410A Refrigerant - Environmentally friendly., Scroll Compressors - Single speed scroll compressors are furnished on all models., Eco-last Coil System (All KGB Models and KGA072 and 090 Models) - Smaller, lighter condenser coil with improved heat transfer, High Pressure Switches - Protect compressor., Isolated Compressor Compartment - Allows performance check during normal compressor operation without disrupting airflow., Direct or Belt Drive Blower Motors - Direct drive (024, 030, 036, 048 and 060 models). Belt drive motors (036, 048, 060, 072 and 090 models) to maximize air performance., Independent Motor Mounts - Allows for easy and efficient service access without removing the top panel, Downflow or Horizontal Airflow - Easy field conversion., Two Fork Lift Slots on Three Sides - Easy to pick up and transport units from almost any angle., Corrosion-Resistant Removable, Reversible Drain Pan - Provides application flexibility, durability and improved serviceability., Thermostatic Expansion Valves (All KGB Models and KGA036, 048 and 060 Models) - Provide peak cooling performance across the entire application range. ALLIED AIR COMMERCIAL
R-410A Refrigerant - Environmentally friendly., Scroll Compressors - Single speed scroll compressors are furnished on all models., Eco-last Coil System (All KCB Models and KCA072 and 090 Models) - Smaller, lighter condenser coil with improved heat transfer, High Pressure Switches - Protect compressor., Isolated Compressor Compartment - Allows performance check during normal compressor operation without disrupting airflow., Direct or Belt Drive Blower Motors - Direct drive (024, 030, 036, 048 and 060 models). Belt drive motors (036, 048, 060, 072 and 090 models) to maximize air performance., Independent Motor Mounts - Allows for easy and efficient service access without removing the top panel. Downflow or Horizontal Airflow - Easy field conversion., Two Fork Lift Slots on Three Sides - Easy to pick up and transport units from almost any angle. Corrosion-Resistant Removable, Reversible Drain Pan - Provides application flexibility, durability and improved serviceability., Thermostatic Expansion Valves (All KCB Models and KCA036, 048 and 060 Models) - Provide peak cooling performance across the entire application range. ALLIED AIR COMMERCIAL
R-410A Refrigerant - Environmentally friendly., Scroll Compressors - Single speed scroll compressors are furnished on all models., Eco-last Coil System (All KGB Models and KGA072 and 090 Models) - Smaller, lighter condenser coil with improved heat transfer, High Pressure Switches - Protect compressor., Isolated Compressor Compartment - Allows performance check during normal compressor operation without disrupting airflow., Direct or Belt Drive Blower Motors - Direct drive (024, 030, 036, 048 and 060 models). Belt drive motors (036, 048, 060, 072 and 090 models) to maximize air performance., Independent Motor Mounts - Allows for easy and efficient service access without removing the top panel, Downflow or Horizontal Airflow - Easy field conversion., Two Fork Lift Slots on Three Sides - Easy to pick up and transport units from almost any angle., Corrosion-Resistant Removable, Reversible Drain Pan - Provides application flexibility, durability and improved serviceability., Thermostatic Expansion Valves (All KGB Models and KGA036, 048 and 060 Models) - Provide peak cooling performance across the entire application range. ALLIED AIR COMMERCIAL
Heating System, Aluminized steel inshot burners, direct spark ignition, electronic flame sensor, combustion air inducer, redundant automatic dual stage gas valve with manual shut-off., Heat Exchanger :, Tubular construction, aluminized steel, life cycle tested., Electronic Pilot Ignition, Watchguard circuit on module automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance service calls., Limit Control:, Factory installed, limit control with fixed temperature setting. Heat limit control protects heat exchanger and other components from overheating., Safety Switches:, Flame roll-out switch, flame sensor and combustion air inducer proving switch protect system operation., Cooling System, Designed to maximize sensible and latent cooling performance at design conditions., System can operate from 30 F to 125 F without any additional controls., R-410A Refrigerant:, Non-chlorine based, ozone friendly, R-410A., High Pressure Switches, Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation., Filter/Driers:, High capacity filter/drier protects the system from dirt and moisture., Eco-last Coil System, Condenser coil features lightweight, all aluminum brazed fin construction., Constructed of three components: a flat extrusion tube, fins in-between the flat extrusion tube and two refrigerant manifolds., Evaporator Coil:, Copper tube construction, enhanced rippled-edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer., Condensate Drain Pan:, Plastic pan, sloped to meet drainage requirements of ASHRAE 62.1, Side drain connections., Outdoor Coil Fan Motors, Thermal overload protected, totally enclosed, permanently lubricated ball bearings, shaft up, wire basket mount., Outdoor Coil Fans:, PVC coated fan guard furnished., Cabinet, Construction, Heavy-gauge steel panels and full perimeter heavy-gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation., Warranty, Limited ten years aluminized heat exchanger, limited fifteen years optional stainless steel heat exchanger, Limited five years on compressors, Limited three years on the Eco-last Coil System., Limited one year all other covered components., Approvals, AHRI Certified to AHRI Standard 340/360-2007, Units are ETL listed., Components bonded for grounding to meet safety standards for servicing required by UL, ULC and National and Canadian Electrical Codes. ALLIED AIR COMMERCIAL
Product Image Not Available Roof Curb
Locke Part #: L4141 MFG Part #: 11T96
ALLIED AIR COMMERCIAL
Product Image Not Available Roof Curb
Locke Part #: L4150 MFG Part #: 11F59
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
TAA120S4DY 10T A/H 208/230V R410A
Locke Part #: L4339 MFG Part #: 45W68
APPLICATIONS, Convertible upflow or horizontal design., Each refrigerant circuit has a dedicated expansion valve., Dual distribution system for two stage capacity control during cooling cycles., Air handlers are shipped factory assembled ready to install. Standard static blower drive is furnished factory installed., REFRIGERANT SYSTEM, Multi-Circuit, Copper Tube Coil, Coils on 090-120 models are face split with separate circuits, each circuit has its own expansion valve., Coil is constructed of aluminum fins fitted to durable seamless, rifled copper tubes., Flared tubing connections and silver soldering provide tight, leakproof joints., Refrigerant Piping and Drain Connections, Refrigerant line inlets (knockouts) are provided on both sides of the cabinet., Refrigerant lines require sweat connections and are made internal to the cabinet., Condensate drain outlet extends outside the cabinet for ease of connection. Condensate drain can be relocated and repositioned., BELT DRIVE BLOWERS, Single blower wheel., Centrifugal belt driven blowers deliver large air volumes quietly and with low power consumption., Heavy-duty blower wheels, with forward curved blades and double inlet are statically and dynamically balanced., Heavy-duty bearings are permanently sealed and lubricated., CABINET, Cabinet is constructed of heavy-gauge, galvanized steel completely lined with thick fiberglass insulation for quiet and efficient operation., Drain Pan, Deep, corrosion resistant plastic drain pan. ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
ALLIED AIR COMMERCIAL
Feedback