Fan_Control.jpg40 VA Fan Control Center with DPDT Switch, 120VAC
Locke Part #: L4543MFG Part #: R8285B1038/U Compare
Voltage: 120 VAC, Dimensions: 4-3/16" x 4-1/2" x 2-13/16", Application: For "Total Comfort" applications with electronic air cleaner, humidifier and blower motor, Horsepower: 3/4 HP, Power Consumption: 11 W (max.), Contacts: Silver Cadmium Oxide, Frequency: 60 Hz, Tradeline Value: Tradeline, Supply Voltage: 40 VA; 26.5 V - Secondary, Switching Action: DPDT, Contact Rating (AFL): 12, Contact Rating (ALR): 60, Overload Protection: Inherent, Replacement Relay: R8222D, Switching: DPDT Transformer powers low voltage control systems and provides overload protection., Low voltage terminal board provides convenient connections for thermostat and heating and cooling equipment wiring., Mounts on standard 4 x 4 in. junction box., Relay is easily replaced without disturbing wiring., Certifications & Approvals:, UL Component Recognized; File No. E4436, Vol.15, Sec.1, Guide No.XAPX2, CSA certified File No. LR95329-17 HONEYWELL INC
Fan_Control.jpg40 VA Fan Control Center with SPDT Switch, 120VAC
Locke Part #: L4542MFG Part #: R8285A1048/U Compare
Voltage: 120 VAC, Dimensions: 4-3/16" x 4-1/2" x 2-13/16", Application: For single-or two speed fan, Horsepower: 3/4 HP, Power Consumption: 11 W (max.), Contacts: Silver Cadmium Oxide, Frequency: 60 Hz, Tradeline Value: Tradeline, Supply Voltage: 40 VA; 26.5 V - Secondary, Switching Action: SPDT, Contact Rating (AFL): 12, Contact Rating (ALR): 60, Overload Protection: Inherent, Replacement Relay: R8222B, Switching: SPDT Transformer powers low voltage control systems and provides overload protection., Low voltage terminal board provides convenient connections for thermostat and heating and cooling equipment wiring., Mounts on standard 4 x 4 in. junction box., Relay is easily replaced without disturbing wiring., Certifications & Approvals:, UL Component Recognized; File No. E4436, Vol.15, Sec.1, Guide No.XAPX2, CSA certified File No. LR95329-17 HONEYWELL INC
Agency: U.L. file fan center E73641, Mars Number: 24013, Transformer Primary Voltage: 120, Transformer Primary Hz: 60, Transformer Primary Connections: Color coded leads, prestripped, Transformer Secondary Voltage: 24V, Transformer Secondary VA: 40, Transformer Secondary Connections: Terminal board with 5 screw terminals, Relay: SPDT, Contact Ratings (Full Load): 13.8A @ 120VAC, 6.9A @ 240VAC, Contact Ratings (Locked Rotor): 82.8A @ 120VAC, 41.4A @ 240VAC White-Rodgers