Dimensions: 3-15/16" H x 5-7/16" W x 2-5/8" D, Includes: Damper connection with automatic vent damper plug, Ambient Temperature Range: -40°F to +165°F, Frequency: 60 Hz, Electrical Ratings: 24 Vac, Flame Failure Response Time: 2 seconds maximum, Tradeline Value: Tradeline, Ignition Trial Time: 15 or 90 sec, PrePurge: Configurable to 30 seconds or no prepurge, Approvals, Canadian Standards Association: Design Certified, Between Trial Time: 5 minute delay after failed trial for ignition., Flame Sense: Single Rod or Two Rods, Ignition Sequence: Continuous Retry, Ignition Source: Internal high voltage spark generator, Ignition System Type: Intermittent Pilot, Ignition Trials To Lockout: continuous retry, Lockout Timing: continuous retry, Max Valve Load @ 24 Vac: 1A Pilot, 2A Main @ 165 F; 1A Pilot, 1A Main @ 175 F, Type of Gas: Natural or LP, Typical Gas Control: VR8204, VR8304, Typical Ignition Hardware: Q345, Q3451, Q3452 Provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances., Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed., For use with Natural or LP gas., Functional equivalent of S86, S8600, S8610 and S90 modules., Includes spark cable adapters to allow field replacement of both Honeywell and competitive controls without replacing existing spark cable.
Dimensions: 5-1/4" H x 4-1/16" W x 1-15/16" Long, Ambient Temperature Range: -40°F to +175°F, Frequency: 60 Hz, Electrical Ratings: 24 Vac, Flame Failure Response Time: 1.5 sec., Tradeline Value: Tradeline, Ignition Trial Time: 4 sec. or 7 sec., PrePurge: 32 seconds, Approvals, Canadian Standards Association: Design Certified, Between Trial Time: (2) 96 sec.- 3 trial mode only, Flame Sense: Single Rod or Two Rods, Ignition Source: Line Voltage (120 VAC) Hot Surface Element (Norton Model 201 or 270), Ignition System Type: Direct Hot Surface Ignition, Ignition Trials To Lockout: 1 or 3, Lockout Timing: 4 sec. or 7 sec., Max Valve Load @ 24 Vac: 2A, Type of Gas: Natural or LP, Typical Gas Control: VR8205, VR8305, Typical Ignition Hardware: Norton 201, Norton 271, Q354 Replaces many White-Rodgers, Robertshaw and Honeywell hot surface ignition models., For 120 Vac (up to 5.0A) surface igniter (Norton 201/271 or equivalent)., For local (single rod) or remote (dual rod) rectification type flame sensing., Contains easy-to-use instructions plus the accessories required to adapt the existing hot surface ignition module., Provides one or three ignition trials (four-second or seven-second trials) per call for heat; prepurge of 32 seconds or less; up to 96 seconds between purge trial times., Specifications:, Ignition Sequence, The number of trials for ignition and trial time is determined by the selection tab. If a selection tab is not installed, the module will operate at four seconds trial time and one ignition trial.
L533.jpg712-008 ELECTRONIC IGN KIT
Locke Part #: L0533MFG Part #: 712-008 Compare
Gas Valve: (700-070) 1/2" x 3/4", Ignition Unit: SP735 (780-735) Lockout L0532, :, Ignition Unit: SP715 (780-715) Non-lockout, Description: Natural Gas only Non-lockout. Valve is designed for natural gas. Pressure regulator is factory set at 3.5" W.C. 200,000 Btu Max. W.C., Caution: Do Not Use On L.P. Gas Applications., L0533, :, Ignition Unit: SP735 (780-735) Lockout, Description: L. P. Gas only-Lockout. Gas valve has natural gas regulator set at 3.5" W.C. A separate L.P. gas pressure regulator set at 11.0" W.C. is also included. 200,000 Btu Max. Nat. Gas / 320,000 Btu Max. LP Gas.
L533.jpg712-017 RETRO-FIT KIT RBTSHAW
Locke Part #: L0532MFG Part #: 712-017 Compare
Gas Valve: 71000 (720-070) 1/2" x 3/4", Ignition Unit: SP715 (780-715) Non-lockout L0532, :, Ignition Unit: SP715 (780-715) Non-lockout, Description: Natural Gas only Non-lockout. Valve is designed for natural gas. Pressure regulator is factory set at 3.5" W.C. 200,000 Btu Max. W.C., Caution: Do Not Use On L.P. Gas Applications., L0533, :, Ignition Unit: SP735 (780-735) Lockout, Description: L. P. Gas only-Lockout. Gas valve has natural gas regulator set at 3.5" W.C. A separate L.P. gas pressure regulator set at 11.0" W.C. is also included. 200,000 Btu Max. Nat. Gas / 320,000 Btu Max. LP Gas.
Application: Robust Field Service Replacement Igniter, Mounting Bracket: Multiple Brackets To Adapt As Field Replacement Of Norton / St. Gobain Silicon Carbide Igniters The Q3200U uses a 120 volt silicon nitride igniter design with long life and high resistance to damage or burn out in the appliance., Includes the specially designed silicon nitride igniter and six different bracket configurations to adapt the igniter to the specific appliance application along with accessory parts to allow mounting and wiring the igniter., Clear instructions and application templates are provided to simplify selection of the proper bracket and ease installation of the replacement.
cef05a89-4ac1-49c9-9a66-eecafada4313.jpgIgnition Control (lockout)
Locke Part #: L0402MFG Part #: 780-002 Compare
L0402
L401.jpgIgnition Control (non-lockout)
Locke Part #: L0401MFG Part #: 780-001 Compare
Wall-mount, wash-down urinal, Rim-flushing action, Exposed trap, Easy to clean, Concealed hanger and bolts, Includes 3/4" top spud and hanger. Less flushometer, Compatible Carriers Zurn Z1221 & Z1222 Series, Meets or exceeds ASME A112.19.-2008/CSA B45.1-08
L405.jpgIgnition Control Unit (lockout)
Locke Part #: L0405MFG Part #: 780-845 Compare
L0405, - Universal lockout model. Replaces SP735 and SP735A. Has three 60 second valve trials interrupted by a five minute purge cycle before 100% lockout.
L404.jpgIgnition Control Unit (Universal Lockout)
Locke Part #: L0404MFG Part #: 780-735 Compare
L0404, - Flame, resuscitation system. Use with gas valves 7000BDER and 7100DER. Has 60 second lockout timing.
Application: Provide Pilot Flame Ignition, Orifice: 0.018", Mounting Bracket: B, Type of Gas: Natural, Aeration: Non-primary, Compression Fitting Length: 0.78", Compression Fitting Size: 1/4", Direction of Front Tip: Front, Leadwire Temperature Ratings: 968° C, Tip Style: Single Includes pilot burner with bracket, ceramic-insulated Kanthal flame rod/spark igniter and ground strap., Single tip style., Special mounting bracket with screws to convert "B" bracket to "A" bracket.
Operating Temperature Range: -40 to +175°F (-40 to +79°C), Input Voltage: 25 VAC 50 / 60 Hz, Valve Relay: 1.5 amp @ 25 VAC 50 / 60 Hz 0.6 pf, Ignitor Relay: 2.0 amp @ 120 VAC 50 / 60 Hz (resistive), Humidity Range: 5% to 93% relative humidity (non-condensing), Maximum Input Current @ 25 VAC: 0.45 amp, Inducer Relay: 2.2 FLA – 3.5 LRA @ 120 VAC, Circulator Relay: 14.5 FLA – 25.0 LRA @ 120 VAC Includes diagnostic indicator flash codes, 3 fan speeds, Remote flame sense, Humidifier and electronic air cleaner connections (optional), Kit includes:, 1 50A66-843 Ignition Control Board, 1 Wiring harness (9-pin to 12-pin), 1 Wiring harness (4-pin to 6-pin), 1 Mounting panel, 4 Stand-off fasteners, 1 Circuit breaker, 1 4" blue wire, 2 Wiring diagrams
Dimensions: 4.13" W x 4.13" H x 1.5" D, Electrical Rating: Input 18 to 30 VAC, 25 VAC nominal, Max. Input Current @ 25 VAC; 200mA @ 25°C, Mounting: Surface mount or 4” x 4 junction box, Operating Temperature Range: -40° to +175°F (-40° to +80°C), Agency: A.G.A. and C.G.A. design certified, Valve Relay: 1.5 amps @ 25 VAC 60 Hz .6pf, Ignitor Relay: 6.0 amps @ 120 VAC 60 Hz resistive, Humidity Range: 95% RH (non-condensing) max, Applications: For use with all gases, Min Current to Insure Flame: 2 µADC, Min Current for Non-Detection: 0.2 µADC, Max Allowable Leakage Resistance: 100 M Ohms
Operating Temperature Range: -40 to +175°F (-40 to +79°C), Input Voltage: 25 VAC 50 / 60 Hz, Valve Relay: 1.5 amp @ 25 VAC 50 / 60 Hz 0.6 pf, Ignitor Relay: 6.0 amp @ 120 VAC 50 / 60 Hz (resistive), Humidity Range: 5% to 93% relative humidity (non-condensing), Maximum Input Current @ 25 VAC: 0.45 amp, Inducer Relay: 2.2 FLA – 3.5 LRA @ 120 VAC, Circulator Relay: 14.5 FLA – 25.0 LRA @ 120 VAC
Operating Temperature Range: -40 to +175°F (-40 to +79°C), Input Voltage: 25 VAC 50 / 60 Hz, Valve Relay: 1.5 amp @ 25 VAC 50 / 60 Hz 0.6 pf, Ignitor Relay: 6.0 amp @ 120 VAC 50 / 60 Hz (resistive), Humidity Range: 5% to 93% relative humidity (non-condensing), Maximum Input Current @ 25 VAC: 0.45 amp, Inducer Relay: 2.2 FLA – 3.5 LRA @ 120 VAC, Circulator Relay: 14.5 FLA – 25.0 LRA @ 120 VAC, Electronic Air Cleaner and Humidifier: 1 A @ 120 VAC