Loading ...

Search in: Time Delays Category

Lower cost, full performance version featuring bright LED indicators to display system faults, Monitors front and back sides of system, Universal voltage operation: 190-630 VAC, Knob-adjustable features and system set points, Reset mode: choice of auto or manual (lockout), Protects against voltage unbalance, high/low voltage, phase loss, reversal, faulty power, incorrect sequencing and rapid short cycling, Built-in anti-short cycle protection, Specifications:, Output:, Relay, SPDT, N.O.: 10 amps, N.C.: 6 amps ICM CONTROLS 800442000138
Fully programmable with LCD diagnostic display, Easy to configure - simple push button setup, Identifies front and back side faults, Reset mode: choice of auto or manual, Protects against: voltage unbalance, high/low voltage, phase loss, reversal, faulty power, incorrect sequencing and rapid short cycling, Reliable, high temperature LCD to 167, Simultaneous voltage display, no scrolling, Line voltage programmable, Universal voltage operation: 190-630 VAC, Specifications:, Output:, Relay, SPDT, N.O.: 10 amps,, N.C.: 6 amps ICM CONTROLS 800442000206
ICM203-n_zm.jpgDelay on Break Timer, 10 minutes adj.
Locke Part #: L4753MFG Part #: ICM203B
Compressor lockout/anti-short cycle timer, Helps to protect compressors from damage, caused by rapid short cycling, Simple, Universal voltage, 2-wire hookup, Adjustable timing,, 1.5 amps, 15 amp inrush, 40 mA holding current, Voltage drop:, 3.5 V typical, 4.5 V maximum @ 1.5 amps ICM CONTROLS 800442000169
ICM200_zm.jpgDelay on Break Timer, 3 minutes fixed
Locke Part #: L4751MFG Part #: ICM200B
Compressor lockout/anti-short cycle timer, Helps to protect compressors from damage caused by rapid short cycling, Simple, 2-wire hookup, Fixed timing, 18-30 VAC, 1.5 amps, 15 amp inrush, Voltage drop:, 3.5 V typical, 4.5 V maximum @ 1.5 amps ICM CONTROLS 800442000473
ICM201_zm.jpgDelay on Break Timer, 5 minutes fixed
Locke Part #: L4752MFG Part #: ICM201B
Compressor lockout/anti-short cycle timer, Helps to protect compressors from damage caused by rapid short cycling, Simple, 2-wire hookup, Fixed timing, 18-30 VAC,, 1.5 amps, 15 amp inrush, Voltage drop:, 3.5 V typical, 4.5 V maximum @ 1.5 amps ICM CONTROLS 800442000503
Universal voltage operation, Higher 1.5 amp power rating, Knob-adjustable time delays, Works with anticipator-type thermostats, One model replaces many in field, Ideal for compressor staging, 1.5 amps, 15 amp inrush ICM CONTROLS 800442000343
ICM253_zm.jpgFan Delay Timer, adj. off delay
Locke Part #: L4754MFG Part #: ICM253B
UL 873 recognition for compressor applications, Post-purge fan delay timer, OFF delay purges ducts of residual air at the end of the heating/cooling cycle, Interrogation delay eliminates nuisance trips due to thermostat bounce/tampering, Specifications:, Output:, 1 amp, maximum, 40 ma minimum, 10 amp inrush ICM CONTROLS 800442000688
ICM254_zm.jpgFan Delay Timer, Dual on/off adj. delays
Locke Part #: L4755MFG Part #: ICM254B
Dual function fan delay timer, Controls the circulating fan in heat pump, A/C and forced air systems, OFF delay controls fan relay to purge ducts of residual air at the end of the heating/cooling cycle, ON delay allows air to reach the proper comfort level prior to energizing the fan, Specifications:, Output:, 1 amp maximum, 40mA minimum, 10 amp inrush ICM CONTROLS 800442000695
Integral heat pump bypass circuitry allows electonic bypass of speed control, Eliminates overshoots common to on/off and pressure switch controls, Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions, Features: hard start, low temperature bypass, isolated 24 VAC supply, RoHS compliant / lead free design, Controls up to 3 refrigeration circuits, Typical application: A/C and heat pumps, Specifications:, Input:, 50/60 Hz 1.8 VA max., Line input: 120-480 VAC, Output:, Maximum: 10 amps, Minimum: 100 mA ICM CONTROLS
ICM CONTROLS 800442029511
ICM CONTROLS 800442029542
TD68.jpgTIME DELAY
Locke Part #: L4422MFG Part #: TD68
SEALED UNIT PARTS CO., INC 687152144402
TD72.jpgTIME DELAY
Locke Part #: L4423MFG Part #: TD72
Delay on Make Timers (DOB), Adjustable time delay on break relay 6 seconds to 5 minutes, 1/4" male quick connect terminals, Cannot be used with a cooling anticipator SEALED UNIT PARTS CO., INC 687152144419