Wire, Cord & Cable Categories

Loading ...

Loading ...

Search in: Wire, Cord & Cable Category

Application:, Construction:, Conductors Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation Cross-linked polyethylene (XLPE) per UL-854. Sunlight-resistant in all colors 6 AWG and larger, Standards: Encore Wire Corp
1 AWG, Stranded, Black THHN Wire, 500' Reel
Locke Part #: P0789 MFG Part #: 118101701440
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
1/0 AWG, Stranded, Black THHN Wire, 500' Reel
Locke Part #: P0780 MFG Part #: 118101801440
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 0 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836., Assembly:, Applications:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544., National Electric Code (NEC ) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Product Image Not Available 10 AWG, Solid, Black Color THHN Wire, 500' Reel
Locke Part #: P0756 MFG Part #: 105100901050
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 10 AWG, Solid, Blue Color THHN Wire, 500' Reel
Locke Part #: P0739 MFG Part #: 105100904050
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 10 AWG, Solid, Brown Color THHN Wire, 500' Reel
Locke Part #: P0865 MFG Part #: 105100908050
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 10 AWG, Solid, Green Color THHN Wire, 500' Reel
Locke Part #: P0747 MFG Part #: 105100905050
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 10 AWG, Solid, Orange Color THHN Wire, 500' Reel
Locke Part #: P0866 MFG Part #: 105100907050
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 10 AWG, Solid, Red Color THHN Wire, 500' Reel
Locke Part #: P0758 MFG Part #: 105100903050
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 10 AWG, Solid, White Color THHN Wire, 500' Reel
Locke Part #: P0757 MFG Part #: 105100902050
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 10 AWG, Solid, Yellow Color THHN Wire, 500' Reel
Locke Part #: P0864 MFG Part #: 105100906050
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Country of Origin: USA, Package Length: 5, Package Height: 11, Package Width: 15, Package Weight: 63, Mfg Standards/Approvals: UL File E-123775, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type NM-B, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 3, Conductor Type: Solid Ground Copper, Conductor Size: 10 AWG, Outside Diameter: 0.21 x 0.493 in, Length: 500 ft Reel, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Orange, Temperature Rating: 90 deg C Color code polyvinyl chloride compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Solid 14 to 10 AWG soft, uncoated copper conductor per ASTM-B3, Soft, uncoated copper grounding conductor per ASTM-B3 or ASTM-B8, A 30 mil, color coded, flame retardant and moisture resistant PVC jacket is applied over the completed assembly Encore Wire Corp 739373012401
Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
10/2G AWG (With Ground) Romex Wire NM-B, 250' EZ
Locke Part #: P0702 MFG Part #: 101210900030
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Country of Origin: USA, Package Length: 5, Package Height: 11, Package Width: 18, Package Weight: 170, Mfg Standards/Approvals: UL File E-123775, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type NM-B, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 4, Conductor Type: Solid Ground Copper, Conductor Size: 10 AWG, Outside Diameter: 0.43 in, Length: 1000 ft Reel, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Orange, Temperature Rating: 90 deg C Color code polyvinyl chloride compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Solid 14 to 10 AWG soft, uncoated copper conductor per ASTM-B3, Soft, uncoated copper grounding conductor per ASTM-B3 or ASTM-B8, A 30 mil, color coded, flame retardant and moisture resistant PVC jacket is applied over the completed assembly Encore Wire Corp 739373019080
10/3G AWG (With Ground) Romex Wire NM-B, 250' EZ
Locke Part #: P0724 MFG Part #: 101310900030
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Applications:, C or not to exceed 75 C in oil or coolants. For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3 Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83, Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 12 AWG, Solid, Black Color THHN Wire, 500' Reel
Locke Part #: P0777 MFG Part #: 105100801060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Product Image Not Available 12 AWG, Solid, Blue Color THHN Wire, 500' Reel
Locke Part #: P0775 MFG Part #: 105100804060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Product Image Not Available 12 AWG, Solid, Brown Color THHN Wire, 500' Reel
Locke Part #: P0714 MFG Part #: 105100808060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Product Image Not Available 12 AWG, Solid, Gray Color THHN Wire, 500' Reel
Locke Part #: P0719 MFG Part #: 105100811060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Product Image Not Available 12 AWG, Solid, Green Color THHN Wire, 500' Reel
Locke Part #: P0776 MFG Part #: 105100805060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Product Image Not Available 12 AWG, Solid, Orange Color THHN Wire, 500' Reel
Locke Part #: P0685 MFG Part #: 105100807060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Product Image Not Available 12 AWG, Solid, Purple Color THHN Wire, 500' Reel
Locke Part #: P0774 MFG Part #: 105100810060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Product Image Not Available 12 AWG, Solid, Red Color THHN Wire, 500' Reel
Locke Part #: P0779 MFG Part #: 105100803060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Product Image Not Available 12 AWG, Solid, White Color THHN Wire, 500' Reel
Locke Part #: P0778 MFG Part #: 105100802060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Product Image Not Available 12 AWG, Solid, Yellow Color THHN Wire, 500' Reel
Locke Part #: P0684 MFG Part #: 105100806060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards: Encore Wire Corp
Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards: Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
12/2G AWG (With Ground) Romex Wire NM-B, 250' EZ
Locke Part #: P0700 MFG Part #: 101210800030
Country of Origin: USA, Package Length: 13.5, Package Height: 13.5, Package Width: 2.5, Package Weight: 20, Mfg Standards/Approvals: UL File E-123775, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type NM-B, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Solid Ground Copper, Conductor Size: 12 AWG, Outside Diameter: 0.16 x 0.45 in, Length: 250 ft EZ Pack, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Yellow, Temperature Rating: 90 deg C Color code polyvinyl chloride compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Solid 14 to 10 AWG soft, uncoated copper conductor per ASTM-B3, Soft, uncoated copper grounding conductor per ASTM-B3 or ASTM-B8, A 30 mil, color coded, flame retardant and moisture resistant PVC jacket is applied over the completed assembly Encore Wire Corp 739373003058
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
12/3G AWG (With Ground) Romex Wire NM-B, 250' EZ
Locke Part #: P0701 MFG Part #: 101310800030
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Country of Origin: USA, Package Length: 4, Package Height: 11, Package Width: 12, Package Weight: 60, Mfg Standards/Approvals: UL File E-123775, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type NM-B, Voltage Rating: 600 VAC, Amperage Rating: 15 A, Number of Conductors: 3, Conductor Type: Solid Ground Copper, Conductor Size: 14 AWG, Outside Diameter: 0.17 x 0.39 in, Length: 1000 ft Reel, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: White, Temperature Rating: 90 deg C Color code polyvinyl chloride compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Solid 14 to 10 AWG soft, uncoated copper conductor per ASTM-B3, Soft, uncoated copper grounding conductor per ASTM-B3 or ASTM-B8, A 30 mil, color coded, flame retardant and moisture resistant PVC jacket is applied over the completed assembly Encore Wire Corp 739373001085
Product Image Not Available 14 AWG, Solid, Black Color THHN Wire, 500' Roll
Locke Part #: P0797 MFG Part #: 105100701060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 14 AWG, Solid, Blue Color THHN Wire, 500' Roll
Locke Part #: P1646 MFG Part #: 105100704060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 14 AWG, Solid, Brown Color THHN Wire, 500' Roll
Locke Part #: P1649 MFG Part #: 105100708060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 14 AWG, Solid, Gray Color THHN Wire, 500' Roll
Locke Part #: P1648 MFG Part #: 105100711060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 14 AWG, Solid, Green Color THHN Wire, 500' Roll
Locke Part #: P0759 MFG Part #: 105100705060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 14 AWG, Solid, Red Color THHN Wire, 500' Roll
Locke Part #: P1754 MFG Part #: 105100703060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 14 AWG, Solid, White Color THHN Wire, 500' Roll
Locke Part #: P0796 MFG Part #: 105100702060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 14 AWG, Solid, Yellow Color THHN Wire, 500' Roll
Locke Part #: P0760 MFG Part #: 105100706060
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
14 AWG, Stranded, Red Color THHN Wire, 500' Reel
Locke Part #: P1757 MFG Part #: 106100703460
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
14 ga SOOW Portable Power Cable - 90°C 600V, 3 Conductors
Locke Part #: P0678 MFG Part #: 14/3 SOOW-A CORD 250' R
For use with portable tools, equipment, appliances, small motors and associated machinery where flexibility and durability are required, Has a stranded soft drawn bare copper conductor per ASTM B3 and B174., Has premium grade color coded ethylene propylene diene monomer EPDM insulation., It has an overall jacket of black chlorinated polyethylene CPE, which is oil, moisture and abrasion resistant., Standards:, UL flexible cord Subject 62, CSA flexible cord C22.2-49, OSHA accepted , MSHA approved, Federal Specification JC 580 PRIORITY WIRE & CABLE INC
Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
14/2G AWG (With Ground) Romex Wire NM-B, 250' EZ
Locke Part #: P0699 MFG Part #: 101210700030
Country of Origin: USA, Package Length: 13.5, Package Height: 13.5, Package Width: 2.5, Package Weight: 14, Mfg Standards/Approvals: UL File E-123775, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type NM-B, Voltage Rating: 600 VAC, Amperage Rating: 15 A, Number of Conductors: 3, Conductor Type: Solid Ground Copper, Conductor Size: 14 AWG, Outside Diameter: 0.17 x 0.39 in, Length: 250 ft EZ Pack, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: White, Temperature Rating: 90 deg C Color code polyvinyl chloride compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Solid 14 to 10 AWG soft, uncoated copper conductor per ASTM-B3, Soft, uncoated copper grounding conductor per ASTM-B3 or ASTM-B8, A 30 mil, color coded, flame retardant and moisture resistant PVC jacket is applied over the completed assembly Encore Wire Corp 739373001054
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
14/3G AWG (With Ground) Romex Wire NM-B, 250' EZ
Locke Part #: P0683 MFG Part #: 101310700030
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
18 AWG, Solid, Yellow Color TFN Wire, 500' Reel
Locke Part #: P6524 MFG Part #: 105100506060
Slick, Nylon outer jacket for easy pulling. All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B174, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound, Applications:, Type TFFN (stranded) or TFN (solid) conductors are primarily used as fixture wire as defined by the National Electrical, Code (NEC) at temperatures not to exceed 90 C in dry locations., For applications requiring Type MTW, the conductor is permitted for use in dry locations at 90 C or not to exceed 60 C in wet locations or where exposed to oils or coolants., For applications requiring Type AWM, conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., All conductors are permitted for new construction or rewiring for 600-volt applications., Jacket:, A tough, polyamide, Nylon outer covering, Standards:, Underwriters Laboratories Standards, UL-62, UL-66, UL-758 and UL-1063, AWM Spec 1310, 1312, 1316, 1318, 1321, ASTM Stranding Class B3, B8, B787, Canadian Standard Association C22.2 No. 127, NFPA 70: National Electrical Code (NEC) ARRA 2009, Section 1605 "Buy American" Compliant Encore Wire Corp
2 AWG, Solid, Bare Copper Wire, 500' Reel
Locke Part #: P6373 MFG Part #: 170101600140
Highest conductivity per unit area of all common commercial metals., Excellent corrosion resistance., Flexible; easily worked and formed into place., Packaged on non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installations., Good fatigue-resistance; not subject to breaks due to nicks or cuts when terminating., Totally recyclable with high scrap value., Contact your local representative for information on the Encore Wire Scrap Purchase Program., Construction:, Soft-Drawn Solid or Stranded, Annealed Bare Copper., Applications:, Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding., Standards:, ASTM-B3 for soft-drawn solid copper wire., ASTM-B8 for soft-drawn concentric lay stranded copper wire., ASTM-B787 for 19-wire combination unilay stranded wire., ARRA 2009; Section 1605 "Buy American" Compliant. Encore Wire Corp
2 AWG, Stranded, Black THHN Wire, 500' Reel
Locke Part #: P0773 MFG Part #: 118101601440
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Insulation compound carries VW-1 (vertical wire flame) rating and FT2 (horizontal flame) rating and is sunlight-resistant (6 AWG and larger) in all colors., 1/0 AWG and larger are rated for CT use and comply with IEEE 1202/FT4 Flame Test., When used as RHH or RHW-2, cable complies with ICEA T-29-520 (210,000 Btu/hr) Flame Test., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, Insulation:, Cross-linked polyethylene (XLPE) per UL-854. Sunlight-resistant in all colors 6 AWG and larger, Applications:, Type USE-2, RHH or RHW-2 cables with Aluminum Alloy 8000 Series conductors are suitable for use in conduit and raceways installed underground in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90 C., Permitted for Type USE-2 per UL-854 for applications requiring direct burial., For applications requiring Type RHH or RHW-2, conductor temperatures shall not exceed 90 C in wet or dry locations., Type USE-2, RHH, or RHW-2 is permitted for 600 volt applications., Standards:, Underwriters Laboratories Standards UL-44; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836;, Federal Specification AA-59544; NEMA WC70 / ICEA S-95-658; NEMA RV4 2012; NFPA 70., National Electrical Code (NEC ). ARRA 2009 Section 1605 Buy American Compliant., IEEE 1202/FT4 Flame Test; ICEA T-29-520 (210,000 Btu/hr) Flame Test. Encore Wire Corp
Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836. The ground/neutral is evenly distributed and helically applied over the insulated conductors to produce the equivalent size required by UL-854., Application:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544; National Electrical Code (NEC) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 0 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836., Assembly:, Applications:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544., National Electric Code (NEC ) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
2-2-2-4 AWG, Type SE - Style R Wire, 500' Reel
Locke Part #: P6482 MFG Part #: 104151611240
Conductors:, 7-strand: Class B concentrically stranded per ASTM-B8, 19-strand: Combination unilay stranded conductors per ASTM-B787, Insulation:, High dielectric strength, heat- and moisture-resistant, black or colored Polyvinyl Chloride (PVC) rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN or THWN wire., Conductor jacket:, Clear Nylon sheath meeting the requirements of UL-83 for THHN or THWN ground/neutral conductor:, Bare, soft-drawn grounding conductor per ASTM-B3, ASTM-B8, or ASTM-B787, Applications:, Assembly:, Conductors are twisted together with the bare, copper grounding conductor in one interstice. A glass-reinforced tape is applied over the cabled core., Overall Jacket:, Extruded, protective gray sunlight-resistant PVC jacket over the taped assembly in accordance with UL Standard 854., Standards:, Underwriters Laboratories Standards UL-83, UL-854., Federal Specifications AA59544., National Electrical Code Articles 338 & 230., NEMA RV4 2009., ARRA 2009; Section 1605 Buy American Compliant. Encore Wire Corp
One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
2/0 AWG, Stranded, Black THHN Wire, 500' Reel
Locke Part #: P0781 MFG Part #: 118101901440
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 0 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836., Assembly:, Applications:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544., National Electric Code (NEC ) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Construction:, Conductors:, Solid: Bare, soft copper per ASTM-B3, 7-strand: Class B concentrically stranded per ASTM-B8, 19-strand: Combination unilay conductors per ASTM-B787, Insulation:, High dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC) rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN or THWN wire., Conductor Jacket, :, Clear Nylon sheath meeting the requirements of UL-83 for THHN or THWN., Ground/Neutral Conductor, :, Soft drawn annealed copper conductors., Sizes smaller than 3 AWG have a round, stranded bare ground/neutral conductor laid parallel between the insulated conductors., Sizes 3 AWG and larger have bare concentric ground/neutral wires wrapped helically over the insulated conductors., Applications:, This cable is manufactured in accordance with Article 338 of the NEC and also the requirements of Underwriters Laboratories Standard 854., Type SE Style U is approved for installation in accordance with Article 230 of the NEC and has a rating of 600 volts., Assembly, :, Overall Jacket, :, Extruded, protective sunlight-resistant gray PVC jacket over the taped assembly in accordance with UL Standard 854., Standards:, Underwriters Laboratories Standards UL-83, UL-854, Federal Specification AA59544, National Electrical Code Articles 338 & 230, NEMA RV4 2009, ARRA 2009; Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, 7-strand: Class B concentrically stranded per ASTM-B8, 19-strand: Combination unilay stranded conductors per ASTM-B787, Insulation:, High dielectric strength, heat- and moisture-resistant, black or colored Polyvinyl Chloride (PVC) rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN or THWN wire., Conductor jacket:, Clear Nylon sheath meeting the requirements of UL-83 for THHN or THWN ground/neutral conductor:, Bare, soft-drawn grounding conductor per ASTM-B3, ASTM-B8, or ASTM-B787, Applications:, Assembly:, Conductors are twisted together with the bare, copper grounding conductor in one interstice. A glass-reinforced tape is applied over the cabled core., Overall Jacket:, Extruded, protective gray sunlight-resistant PVC jacket over the taped assembly in accordance with UL Standard 854., Standards:, Underwriters Laboratories Standards UL-83, UL-854., Federal Specifications AA59544., National Electrical Code Articles 338 & 230., NEMA RV4 2009., ARRA 2009; Section 1605 Buy American Compliant. Encore Wire Corp
Country of Origin: USA, Package Length: 14, Package Height: 18, Package Width: 30, Package Weight: 437, Mfg Standards/Approvals: UL File E-123775, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type NM-B, Voltage Rating: 600 VAC, Amperage Rating: 95 A, Number of Conductors: 4, Conductor Type: Solid Ground Copper, Conductor Size: 2 AWG, Outside Diameter: 0.945 in, Length: 500 ft Reel, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Black, Temperature Rating: 90 deg C Color code polyvinyl chloride compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Solid 14 to 10 AWG soft, uncoated copper conductor per ASTM-B3, Soft, uncoated copper grounding conductor per ASTM-B3 or ASTM-B8, A 30 mil, color coded, flame retardant and moisture resistant PVC jacket is applied over the completed assembly Encore Wire Corp 739373027078
3 AWG, Stranded, Black THHN Wire, 500' Reel
Locke Part #: P0772 MFG Part #: 118101501440
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
3/0 AWG, Stranded, Black THHN Wire, 500' Reel
Locke Part #: P0782 MFG Part #: 118102001440
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
4 AWG, Solid, Bare Copper Wire, 200' Reel
Locke Part #: P0771 MFG Part #: 170101400125
Highest conductivity per unit area of all common commercial metals., Excellent corrosion resistance., Flexible; easily worked and formed into place., Packaged on non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installations., Good fatigue-resistance; not subject to breaks due to nicks or cuts when terminating., Totally recyclable with high scrap value., Contact your local representative for information on the Encore Wire Scrap Purchase Program., Construction:, Soft-Drawn Solid or Stranded, Annealed Bare Copper., Applications:, Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding., Standards:, ASTM-B3 for soft-drawn solid copper wire., ASTM-B8 for soft-drawn concentric lay stranded copper wire., ASTM-B787 for 19-wire combination unilay stranded wire., ARRA 2009; Section 1605 "Buy American" Compliant. Encore Wire Corp
4 AWG, Stranded, Black THHN Wire, 500' Reel
Locke Part #: P0749 MFG Part #: 118101401440
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Insulation compound carries VW-1 (vertical wire flame) rating and FT2 (horizontal flame) rating and is sunlight-resistant (6 AWG and larger) in all colors., 1/0 AWG and larger are rated for CT use and comply with IEEE 1202/FT4 Flame Test., When used as RHH or RHW-2, cable complies with ICEA T-29-520 (210,000 Btu/hr) Flame Test., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, Insulation:, Cross-linked polyethylene (XLPE) per UL-854. Sunlight-resistant in all colors 6 AWG and larger, Applications:, Type USE-2, RHH or RHW-2 cables with Aluminum Alloy 8000 Series conductors are suitable for use in conduit and raceways installed underground in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90 C., Permitted for Type USE-2 per UL-854 for applications requiring direct burial., For applications requiring Type RHH or RHW-2, conductor temperatures shall not exceed 90 C in wet or dry locations., Type USE-2, RHH, or RHW-2 is permitted for 600 volt applications., Standards:, Underwriters Laboratories Standards UL-44; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836;, Federal Specification AA-59544; NEMA WC70 / ICEA S-95-658; NEMA RV4 2012; NFPA 70., National Electrical Code (NEC ). ARRA 2009 Section 1605 Buy American Compliant., IEEE 1202/FT4 Flame Test; ICEA T-29-520 (210,000 Btu/hr) Flame Test. Encore Wire Corp
4-4-4 AWG, Type SE Style U Wire, 500' Reel
Locke Part #: P0682 MFG Part #: 103141411240
Construction:, Conductors:, Solid: Bare, soft copper per ASTM-B3, 7-strand: Class B concentrically stranded per ASTM-B8, 19-strand: Combination unilay conductors per ASTM-B787, Insulation:, High dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC) rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN or THWN wire., Conductor Jacket, :, Clear Nylon sheath meeting the requirements of UL-83 for THHN or THWN., Ground/Neutral Conductor, :, Soft drawn annealed copper conductors., Sizes smaller than 3 AWG have a round, stranded bare ground/neutral conductor laid parallel between the insulated conductors., Sizes 3 AWG and larger have bare concentric ground/neutral wires wrapped helically over the insulated conductors., Applications:, This cable is manufactured in accordance with Article 338 of the NEC and also the requirements of Underwriters Laboratories Standard 854., Type SE Style U is approved for installation in accordance with Article 230 of the NEC and has a rating of 600 volts., Assembly, :, Overall Jacket, :, Extruded, protective sunlight-resistant gray PVC jacket over the taped assembly in accordance with UL Standard 854., Standards:, Underwriters Laboratories Standards UL-83, UL-854, Federal Specification AA59544, National Electrical Code Articles 338 & 230, NEMA RV4 2009, ARRA 2009; Section 1605 Buy American Compliant. Encore Wire Corp
One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Two black triple-rated USE-2/RHH/RHW-2 phase conductors cabled together with one white triple-rated USE-2/RHH/RHW-2 neutral conductor and one green insulated ground wire., All cables employ ASTM 8000 Series aluminum alloy conductors., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600-Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables., Also manufactured and tested according to UL-854, and UL-44., Conductors are surface printed for identification., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL 854, UL 44, and ANSI/ICEA S-105-692., Black XLPE insulation on phase conductors, white XLPE on neutral conductor, green XLPE on ground., Applications:, Quadruplex type USE-2/RHH/RHW-2 with Compact Stranded Aluminum Alloy 8000 Series conductors per ASTM B800; ASTM B801; ASTM B836., Suitable for electrical connections in mobile homes for permanent wiring according to the 2008 NEC., Suitable for wet and dry locations in conduit where temperatures do not exceed 90 C., Direct Burial in earth permitted for Type USE-2, RHH, and RHW-2 per UL854 where temperatures do not exceed 90 C. 600 volt rated. XLPE insulation is sunlight-resistant for 6 AWG and larger., 1/0 AWG and larger complies with IEEE 1202/UL FT-4 flame test., 1/0 AWG and larger also complies with ICEA T-29-520 (210,000 btu/hr) flame test., Standards:, Underwriters Laboratories Standards UL-854; UL-44; ANSI/ICEA S-105-692; IEEE 835-1994; Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836; ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
6 AWG, Solid, Bare Copper Wire, 315' Reel
Locke Part #: P0770 MFG Part #: 170101200035
Highest conductivity per unit area of all common commercial metals., Excellent corrosion resistance., Flexible; easily worked and formed into place., Packaged on non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installations., Good fatigue-resistance; not subject to breaks due to nicks or cuts when terminating., Totally recyclable with high scrap value., Contact your local representative for information on the Encore Wire Scrap Purchase Program., Construction:, Soft-Drawn Solid or Stranded, Annealed Bare Copper., Applications:, Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding., Standards:, ASTM-B3 for soft-drawn solid copper wire., ASTM-B8 for soft-drawn concentric lay stranded copper wire., ASTM-B787 for 19-wire combination unilay stranded wire., ARRA 2009; Section 1605 "Buy American" Compliant. Encore Wire Corp
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
6 AWG, Stranded, Red Color THHN Wire, 500' Reel
Locke Part #: P5323 MFG Part #: 118101203440
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
6/2G AWG (With Ground) Romex Wire NM-B, 125' EZ
Locke Part #: P0705 MFG Part #: 101211200020
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Encore Wire Corp
6/3G AWG (With Ground) Romex Wire NM-B, 125' EZ
Locke Part #: P0706 MFG Part #: 101311200020
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
8 AWG, Solid, Bare Copper Wire, 500' Reel
Locke Part #: P0686 MFG Part #: 170101000040
Highest conductivity per unit area of all common commercial metals., Excellent corrosion resistance., Flexible; easily worked and formed into place., Packaged on non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installations., Good fatigue-resistance; not subject to breaks due to nicks or cuts when terminating., Totally recyclable with high scrap value., Contact your local representative for information on the Encore Wire Scrap Purchase Program., Construction:, Soft-Drawn Solid or Stranded, Annealed Bare Copper., Applications:, Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding., Standards:, ASTM-B3 for soft-drawn solid copper wire., ASTM-B8 for soft-drawn concentric lay stranded copper wire., ASTM-B787 for 19-wire combination unilay stranded wire., ARRA 2009; Section 1605 "Buy American" Compliant. Encore Wire Corp
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
8 AWG, Stranded, Red Color THHN Wire, 500' Reel
Locke Part #: P0807 MFG Part #: 118101003440
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
8/2G AWG (With Ground) Romex Wire NM-B, 125' EZ
Locke Part #: P0703 MFG Part #: 101211000020
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
8/3G AWG (With Ground) Romex Wire NM-B, 125' EZ
Locke Part #: P0704 MFG Part #: 101311000020
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Ideal Industries
Country of Origin: US, Package Length: 8, Package Height: 2, Package Width: 6, Number of Conductors: 10, Conductor Size: 20 AWG, Length: 40 ft, Insulation Material: Thermoplastic Thermoplastic insulated, jacketed wire for low voltage applications, Conductors are solid copper, individually insulated and color coded DiversiTech Corp 780653017289
Country of Origin: US, Package Length: 6.25, Package Height: 0.75, Package Width: 3, Package Weight: 0.2, Specifications: 15 A, 125 VAC DiversiTech Corp 780653021804
Country of Origin: USA, Package Length: 5, Package Height: 11, Package Width: 15, Package Weight: 91, Mfg Standards/Approvals: UL File E-123776, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type UF-B Ground, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Annealed Solid Copper, Conductor Size: 12 AWG, Outside Diameter: 0.195 x 0.415 in, Length: 1000 ft, Insulation Material: PVC Coated, Jacket Material: PVC Coated, Jacket Color: Gray, Temperature Rating: 90 deg C Color code polyvinyl chloride compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Soft, uncoated copper conductor per ASTM-B3 and or B8, A gray, sunlight and fungus resistant PVC jacket Encore Wire Corp 739373031082
Country of Origin: USA, Package Length: 5, Package Height: 11, Package Width: 18, Package Weight: 142, Mfg Standards/Approvals: UL File E-123776, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type UF-B Ground, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 3, Conductor Type: Annealed Solid Copper, Conductor Size: 10 AWG, Outside Diameter: 0.23 x 0.46 in, Length: 1000 ft, Insulation Material: PVC Coated, Jacket Material: PVC Coated, Jacket Color: Gray, Temperature Rating: 90 deg C Color code polyvinyl chloride compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Soft, uncoated copper conductor per ASTM-B3 and or B8, A gray, sunlight and fungus resistant PVC jacket Encore Wire Corp 739373033086
Country of Origin: USA, Package Length: 10, Package Height: 12, Package Width: 24, Package Weight: 225, Mfg Standards/Approvals: UL File E-123776, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type UF-B Ground, Voltage Rating: 600 VAC, Amperage Rating: 40 A, Number of Conductors: 3, Conductor Type: Annealed Stranded Copper, Conductor Size: 8 AWG, Outside Diameter: 0.32 x 0.62 in, Length: 1000 ft, Strands: 7, Insulation Material: PVC Coated, Jacket Material: PVC Coated, Jacket Color: Gray, Temperature Rating: 90 deg C Color code polyvinyl chloride (PVC) compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Soft, uncoated copper conductor per ASTM-B3 and or B8, A gray, sunlight and fungus resistant PVC jacket Encore Wire Corp 739373035080
Country of Origin: USA, Package Length: 10, Package Height: 12, Package Width: 24, Package Weight: 298, Mfg Standards/Approvals: UL File E-123776, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type UF-B Ground, Voltage Rating: 600 VAC, Amperage Rating: 55 A, Number of Conductors: 3, Conductor Type: Annealed Stranded Copper, Conductor Size: 6 AWG, Outside Diameter: 0.385 x 0.8 in, Length: 1000 ft, Strands: 7, Insulation Material: PVC Coated, Jacket Material: PVC Coated, Jacket Color: Gray, Temperature Rating: 90 deg C Color code polyvinyl chloride (PVC) compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Soft, uncoated copper conductor per ASTM-B3 and or B8, A gray, sunlight and fungus resistant PVC jacket Encore Wire Corp 739373037084
Country of Origin: USA, Package Length: 5, Package Height: 11, Package Width: 18, Package Weight: 132, Mfg Standards/Approvals: UL File E-123776, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type UF-B Ground, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 4, Conductor Type: Annealed Solid Copper, Conductor Size: 12 AWG, Outside Diameter: 0.195 x 0.62 in, Length: 1000 ft, Insulation Material: PVC Coated, Jacket Material: PVC Coated, Jacket Color: Gray, Temperature Rating: 90 deg C Color code polyvinyl chloride (PVC) compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Soft, uncoated copper conductor per ASTM-B3 and or B8, A gray, sunlight and fungus resistant PVC jacket Encore Wire Corp 739373045089
Country of Origin: USA, Package Length: 10, Package Height: 12, Package Width: 24, Package Weight: 206, Mfg Standards/Approvals: UL File E-123776, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type UF-B Ground, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 4, Conductor Type: Annealed Solid Copper, Conductor Size: 10 AWG, Outside Diameter: 0.23 x 0.69 in, Length: 1000 ft, Insulation Material: PVC Coated, Jacket Material: PVC Coated, Jacket Color: Gray, Temperature Rating: 90 deg C Color code polyvinyl chloride (PVC) compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Soft, uncoated copper conductor per ASTM-B3 and or B8, A gray, sunlight and fungus resistant PVC jacket Encore Wire Corp 739373047083
Country of Origin: USA, Package Length: 14, Package Height: 18, Package Width: 30, Package Weight: 466, Mfg Standards/Approvals: UL File E-123776, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type UF-B Ground, Voltage Rating: 600 VAC, Amperage Rating: 55 A, Number of Conductors: 4, Conductor Type: Annealed Stranded Copper, Conductor Size: 6 AWG, Outside Diameter: 0.385 x 1.2 in, Length: 1000 ft, Strands: 7, Insulation Material: PVC Coated, Jacket Material: PVC Coated, Jacket Color: Gray, Temperature Rating: 90 deg C Color code polyvinyl chloride (PVC) compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Soft, uncoated copper conductor per ASTM-B3 and or B8, A gray, sunlight and fungus resistant PVC jacket Encore Wire Corp 739373051080
Country of Origin: USA, Package Length: 12, Package Height: 16, Package Width: 24, Package Weight: 294, Mfg Standards/Approvals: UL File E-174428, NEMA RV 4-2012, Reach, RoHS Compliant, Type: Type SE Style U, Voltage Rating: 600 VAC, Amperage Rating: 115 A, Number of Conductors: 3, Conductor Type: Stranded Copper, Conductor Size: 5 to 3 AWG, Length: 500 ft Reel, Strands: 12, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Gray, Temperature Rating: 90 deg C High dielectric strength, heat and moisture resistant, black or colored polyvinyl chloride (PVC) rated 90 deg C wet or dry, meeting the requirements or UL-83 for THHN or THWN-2 wire, Clear nylon sheath meeting the requirements or UL-83 for THHN or THWN-2 conductor jacket, Soft drawn annealed copper conductor, A gray, sunlight and fungus resistant PVC jacket Encore Wire Corp 739373013170
Country of Origin: USA, Package Length: 12, Package Height: 16, Package Width: 24, Package Weight: 337, Mfg Standards/Approvals: UL File E-174428, NEMA RV 4-2012, Reach, RoHS Compliant, Type: Type SE Style U, Voltage Rating: 600 VAC, Amperage Rating: 130 A, Number of Conductors: 3, Conductor Type: Stranded Copper, Conductor Size: 4 to 2 AWG, Length: 500 ft Reel, Strands: 12, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Gray, Temperature Rating: 90 deg C High dielectric strength, heat and moisture resistant, black or colored polyvinyl chloride (PVC) rated 90 deg C wet or dry, meeting the requirements or UL-83 for THHN or THWN-2 wire, Clear nylon sheath meeting the requirements or UL-83 for THHN or THWN-2 conductor jacket, Soft drawn annealed copper conductor, A gray, sunlight and fungus resistant PVC jacket Encore Wire Corp 739373064073
Country of Origin: USA, Package Length: 14, Package Height: 22, Package Width: 32, Package Weight: 795, Mfg Standards/Approvals: UL File E-174428, NEMA RV 4-2012, Reach, RoHS Compliant, Type: Type SE Style R, Voltage Rating: 600 VAC, Amperage Rating: 115 A, Number of Conductors: 4, Conductor Type: Stranded Copper, Conductor Size: 5 to 3 AWG, Outside Diameter: 0.895 in, Length: 1000 ft Reel, Strands: 7, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Gray, Temperature Rating: 90 deg C 7 strand class B concentrically stranded per ASTM-B8, High dielectric strength, heat and moisture resistant, black or colored polyvinyl chloride (PVC) rated 90 deg C wet or dry, meeting the requirements or UL-83 for THHN or THWN-2 wire, Clear nylon sheath meeting the requirements or UL-83 for THHN or THWN-2 conductor jacket, Bare, soft drawn grounding conductor per ASTM-B3, ASTM-B8, or ASTM-B787 ground/neutral conductor, A gray, sunlight and fungus resistant PVC jacket Encore Wire Corp 739373062505
Country of Origin: USA, Package Length: 14, Package Height: 18, Package Width: 30, Package Weight: 582, Mfg Standards/Approvals: UL File E-174428, NEMA RV 4-2012, Reach, RoHS Compliant, Type: Type SE Style R, Voltage Rating: 600 VAC, Amperage Rating: 145 A, Number of Conductors: 4, Conductor Type: Stranded Copper, Conductor Size: 3 to 1 AWG, Outside Diameter: 1.1 in, Length: 500 ft Reel, Strands: 7, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Gray, Temperature Rating: 90 deg C 7 strand class B concentrically stranded per ASTM-B8, High dielectric strength, heat and moisture resistant, black or colored polyvinyl chloride (PVC) rated 90 deg C wet or dry, meeting the requirements or UL-83 for THHN or THWN-2 wire, Clear nylon sheath meeting the requirements or UL-83 for THHN or THWN-2 conductor jacket, Bare, soft drawn grounding conductor per ASTM-B3, ASTM-B8, or ASTM-B787 ground/neutral conductor, A gray, sunlight and fungus resistant PVC jacket Encore Wire Corp 739373013279
Country of Origin: USA, Package Length: 14, Package Height: 22, Package Width: 32, Package Weight: 736, Mfg Standards/Approvals: UL File E-174428, NEMA RV 4-2012, Reach, RoHS Compliant, Type: Type SE Style R, Voltage Rating: 600 VAC, Amperage Rating: 170 A, Number of Conductors: 4, Conductor Type: Stranded Copper, Conductor Size: 2 to 1/0 AWG, Outside Diameter: 1.2 in, Length: 500 ft Reel, Strands: 7, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Gray, Temperature Rating: 90 deg C 7 strand class B concentrically stranded per ASTM-B8, High dielectric strength, heat and moisture resistant, black or colored polyvinyl chloride (PVC) rated 90 deg C wet or dry, meeting the requirements or UL-83 for THHN or THWN-2 wire, Clear nylon sheath meeting the requirements or UL-83 for THHN or THWN-2 conductor jacket, Bare, soft drawn grounding conductor per ASTM-B3, ASTM-B8, or ASTM-B787 ground/neutral conductor, A gray, sunlight and fungus resistant PVC jacket Encore Wire Corp 739373013286
Country of Origin: US, Package Length: 10.0, Package Height: 12.0, Package Width: 24.0, Package Weight: 228.0, Mfg Standards/Approvals: UL E-179429, Reach, RoHS Compliant, Application: Indoor Applications, Voltage Rating: 600, Temperature Rating: 90, Type: Type TC THNN, Number of Conductors: 4, Conductor Type: Stranded Copper, Conductor Size: 10 AWG, Length: 1000 ft Reel, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Black Stranded, uncoated copper conductors per ASTM-B3, ASTM-B8 and ASTM-B787, High dielectric strength, heat and moisture resistant, The insulated conductors are cabled together with a green insulated ground and with or without fillers as required to form a round compact core, Nylon rip-cord is supplied for easy stripping, Color coded insulation with ICEA method 1, A flame retardant, sunlight resistant, black PVC jackets is applied over shielded core, Thermoplastic high heat resistant nylon coated tray cable Encore Wire Corp 739373718129
Country of Origin: US, Package Length: 14, Package Height: 18, Package Width: 30, Package Weight: 340, Mfg Standards/Approvals: UL E-179429, Reach, RoHS Compliant, Type: Type TC THNN, Voltage Rating: 600 VAC, Amperage Rating: 55 A, Number of Conductors: 4, Conductor Type: Stranded Copper, Conductor Size: 10, 8 AWG, Outside Diameter: 0.674 in, Length: 1000 ft Reel, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Black, Temperature Rating: 90 deg C Bare, soft annealed stranded copper conductors per ASTM-B3, ASTM-B8 and ASTM-B787, High dielectric strength, heat and moisture resistant, The insulated conductors are cabled together with a green insulated ground and with or without fillers as required to form a round compact core, Nylon rip-cord is supplied for easy stripping, Black insulation with ICEA method 4 printed number, A flame retardant, sunlight resistant, black PVC jackets is applied over shielded core, Soft, uncoated copper per ASTM-B787, insulated green ground, Thermoplastic high heat resistant nylon coated tray cable Encore Wire Corp 739373014269
Country of Origin: US, Package Length: 14, Package Height: 18, Package Width: 30, Package Weight: 481, Mfg Standards/Approvals: UL E-179429, Reach, RoHS Compliant, Type: Type TC THNN, Voltage Rating: 600 VAC, Amperage Rating: 75 A, Number of Conductors: 4, Conductor Type: Stranded Copper, Conductor Size: 8, 6 AWG, Outside Diameter: 0.789 in, Length: 1000 ft Reel, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Black, Temperature Rating: 90 deg C Bare, soft annealed stranded copper conductors per ASTM-B3, ASTM-B8 and ASTM-B787, High dielectric strength, heat and moisture resistant, The insulated conductors are cabled together with a green insulated ground and with or without fillers as required to form a round compact core, Nylon rip-cord is supplied for easy stripping, Black insulation with ICEA method 4 printed number, A flame retardant, sunlight resistant, black PVC jackets is applied over shielded core, Soft, uncoated copper per ASTM-B787, insulated green ground, Thermoplastic high heat resistant nylon coated tray cable Encore Wire Corp 739373014320
Country of Origin: US, Package Length: 8, Package Height: 14, Package Width: 18, Package Weight: 117, Mfg Standards/Approvals: UL E-179429, Reach, RoHS Compliant, Type: Type TC THNN, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 3, Conductor Type: Stranded Copper, Conductor Size: 12 AWG, Outside Diameter: 0.39 in, Length: 1000 ft Reel, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Black, Temperature Rating: 90 deg C Stranded, uncoated copper conductors per ASTM-B3, ASTM-B8 and ASTM-B787, High dielectric strength, heat and moisture resistant, The insulated conductors are cabled together without a ground and with or without fillers as required to form a round compact core, Nylon rip-cord is supplied for easy stripping, Color coded insulation with ICEA method 1 with printed number, A flame retardant, sunlight resistant, black PVC jackets is applied over shielded core, Plain thermoplastic high heat resistant nylon coated tray cable, Without ground Encore Wire Corp 739373014115
Country of Origin: US, Package Length: 10, Package Height: 12, Package Width: 24, Package Weight: 179, Mfg Standards/Approvals: UL E-179429, Reach, RoHS Compliant, Type: Type TC THNN, Voltage Rating: 600 VAC, Amperage Rating: 40 A, Number of Conductors: 3, Conductor Type: Stranded Copper, Conductor Size: 10 AWG, Outside Diameter: 0.46 in, Length: 1000 ft Reel, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Black, Temperature Rating: 90 deg C Stranded, uncoated copper conductors per ASTM-B3, ASTM-B8 and ASTM-B787, High dielectric strength, heat and moisture resistant, The insulated conductors are cabled together without a ground and with or without fillers as required to form a round compact core, Nylon rip-cord is supplied for easy stripping, Color coded insulation with ICEA method 1 with printed number, A flame retardant, sunlight resistant, black PVC jackets is applied over shielded core, Plain thermoplastic high heat resistant nylon coated tray cable, Without ground Encore Wire Corp 739373014177
Country of Origin: US, Package Length: 10.0, Package Height: 12.0, Package Width: 24.0, Package Weight: 139.0, Mfg Standards/Approvals: UL E-179429, Reach, RoHS Compliant, Application: Indoor Applications, Voltage Rating: 600, Temperature Rating: 90, Type: Type TC THNN, Number of Conductors: 4, Conductor Type: Stranded Copper, Conductor Size: 12 AWG, Length: 1000 ft Reel, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Black Stranded, uncoated copper conductors per ASTM-B3, ASTM-B8 and ASTM-B787, High dielectric strength, heat and moisture resistant, The insulated conductors are cabled together with a green insulated ground and with or without fillers as required to form a round compact core, Nylon rip-cord is supplied for easy stripping, Color coded insulation with ICEA method 1, A flame retardant, sunlight resistant, black PVC jackets is applied over shielded core, Thermoplastic high heat resistant nylon coated tray cable Encore Wire Corp 739373911087
Country of Origin: US, Package Length: 16.0, Package Height: 23.0, Package Width: 48.0, Package Weight: 2138.0, Mfg Standards/Approvals: UL E-179429, Reach, RoHS Compliant, Application: Indoor Applications, Voltage Rating: 600, Amperage Rating: 130, Outside Diameter: 1.112, Temperature Rating: 90, Type: Type TC THNN, Number of Conductors: 4, Conductor Type: Stranded Copper, Conductor Size: 2, 6 AWG, Length: 2000 ft Master, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Black Bare, soft annealed stranded copper conductors per ASTM-B3, ASTM-B8 and ASTM-B787, High dielectric strength, heat and moisture resistant, The insulated conductors are cabled together with a green insulated ground and with or without fillers as required to form a round compact core, Nylon rip-cord is supplied for easy stripping, Black insulation with ICEA method 4 printed number, A flame retardant, sunlight resistant, black PVC jackets is applied over shielded core, Soft, uncoated copper per ASTM-B787, insulated green ground, Thermoplastic high heat resistant nylon coated tray cable Encore Wire Corp 739373910585
Country of Origin: US, Package Length: 28.0, Package Height: 32.0, Package Width: 54.0, Package Weight: 3845.0, Mfg Standards/Approvals: UL E-179429, Reach, RoHS Compliant, Application: Indoor Applications, Voltage Rating: 600, Amperage Rating: 195, Outside Diameter: 1.41, Temperature Rating: 90, Type: Type TC THNN, Number of Conductors: 4, Conductor Type: Stranded Copper, Conductor Size: 2/0, 6 AWG, Length: 2000 ft Master, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Black Bare, soft annealed stranded copper conductors per ASTM-B3, ASTM-B8 and ASTM-B787, High dielectric strength, heat and moisture resistant, The insulated conductors are cabled together with a green insulated ground and with or without fillers as required to form a round compact core, Nylon rip-cord is supplied for easy stripping, Black insulation with ICEA method 4 printed number, A flame retardant, sunlight resistant, black PVC jackets is applied over shielded core, Soft, uncoated copper per ASTM-B787, insulated green ground, Thermoplastic high heat resistant nylon coated tray cable Encore Wire Corp 739373787910
Country of Origin: US, Mfg Standards/Approvals: UL E-179429, Reach, RoHS Compliant, Application: Indoor Applications, Voltage Rating: 600, Amperage Rating: 260, Outside Diameter: 1.726, Temperature Rating: 90, Type: Type TC THNN, Number of Conductors: 4, Conductor Type: Stranded Copper, Conductor Size: 4/0, 4 AWG, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Black Bare, soft annealed stranded copper conductors per ASTM-B3, ASTM-B8 and ASTM-B787, High dielectric strength, heat and moisture resistant, The insulated conductors are cabled together with a green insulated ground and with or without fillers as required to form a round compact core, Nylon rip-cord is supplied for easy stripping, Black insulation with ICEA method 4 printed number, A flame retardant, sunlight resistant, black PVC jackets is applied over shielded core, Soft, uncoated copper per ASTM-B787, insulated green ground Encore Wire Corp 739373913449
Country of Origin: USA, Package Length: 5, Package Height: 8, Package Width: 12, Package Weight: 81, Mfg Standards/Approvals: UL Listed, ASTM-B3, ASTM-B8, ASTM-B787, MasterSpec Division 26 Sections 260519, 26052, Reach, RoHS Compliant, Voltage Rating: 600 VAC, Number of Conductors: 1, Conductor Type: Bare Stranded Copper, Conductor Size: 6 AWG, Outside Diameter: 0.184 in, Length: 1000 ft Reel, Strands: 7, Resistance: 0.403 Ohm Highest conductivity per unit are or all common commercial metal, Excellent corrosion resistance, Flexible, easily worked and formed into place, Packaged or non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installation, Good fatigue resistance, not subject to breaks due to nicks or cuts when terminating, Totally recyclable with high scrap value, Soft drawn bare conductor Encore Wire Corp 739373000682
Country of Origin: USA, Package Length: 8, Package Height: 4, Package Width: 11.75, Package Weight: 26, Mfg Standards/Approvals: UL Listed, ASTM-B3, ASTM-B8, ASTM-B787, MasterSpec Division 26 Sections 260519, 26052, Reach, RoHS Compliant, Voltage Rating: 600 VAC, Number of Conductors: 1, Conductor Type: Bare Stranded Copper, Conductor Size: 2 AWG, Outside Diameter: 0.292 in, Length: 125 ft Spool, Strands: 7 Highest conductivity per unit are or all common commercial metal, Excellent corrosion resistance, Flexible, easily worked and formed into place, Packaged or non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installation, Good fatigue resistance, not subject to breaks due to nicks or cuts when terminating, Totally recyclable with high scrap value, Soft drawn bare conductor Encore Wire Corp 739373053145
Country of Origin: USA, Package Length: 8, Package Height: 14, Package Width: 18, Package Weight: 253, Mfg Standards/Approvals: UL Listed, ASTM-B3, ASTM-B8, ASTM-B787, MasterSpec Division 26 Sections 260519, 26052, Reach, RoHS Compliant, Voltage Rating: 600 VAC, Number of Conductors: 1, Conductor Type: Bare Stranded Copper, Conductor Size: 3/0 AWG, Outside Diameter: 0.454 in, Length: 500 ft Reel, Strands: 19 Highest conductivity per unit are or all common commercial metal, Excellent corrosion resistance, Flexible, easily worked and formed into place, Packaged or non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installation, Good fatigue resistance, not subject to breaks due to nicks or cuts when terminating, Totally recyclable with high scrap value, Soft drawn bare conductor Encore Wire Corp 739373013811
Country of Origin: USA, Package Length: 12, Package Height: 16, Package Width: 24, Package Weight: 639, Mfg Standards/Approvals: UL Listed, ASTM-B3, ASTM-B8, ASTM-B787, MasterSpec Division 26 Sections 260519, 26052, Reach, RoHS Compliant, Voltage Rating: 600 VAC, Number of Conductors: 1, Conductor Type: Bare Stranded Copper, Conductor Size: 4/0 AWG, Outside Diameter: 0.51 in, Length: 1000 ft Reel, Strands: 19, Resistance: 0.0497 Ohm Highest conductivity per unit are or all common commercial metal, Excellent corrosion resistance, Flexible, easily worked and formed into place, Packaged or non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installation, Good fatigue resistance, not subject to breaks due to nicks or cuts when terminating, Totally recyclable with high scrap value, Soft drawn bare conductor Encore Wire Corp 739373013859
Country of Origin: USA, Package Length: 14, Package Height: 22, Package Width: 36, Package Weight: 476, Mfg Standards/Approvals: UL File E-174428, NEMA RV 4-2012, Reach, RoHS Compliant, Type: Type SE Style U, Voltage Rating: 600 VAC, Amperage Rating: 205 A, Number of Conductors: 3, Conductor Type: Stranded Aluminum, Conductor Size: 4/0 AWG, Length: 500 ft Reel, Strands: 19, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Gray, Temperature Rating: 90 deg C Compact stranded aluminum alloy 8000 series per ASTM-B800, ASTM-B801 and ASTM-B836, High dielectric strength, heat and moisture resistant, black or colored polyvinyl chloride (PVC) rated 90 deg C wet or dry, meeting the requirements or UL-83 for THHN or THWN-2 wire, A tough, polyamide, nylon outer covering per UL-83, The ground/neutral is evenly distributed and helically applied over the insulated conductor to produce the equivalent size required by UL-854 Encore Wire Corp 739373887726
Country of Origin: USA, Package Length: 14, Package Height: 22, Package Width: 36, Package Weight: 535, Mfg Standards/Approvals: UL File E-174428, NEMA RV 4-2012, Reach, RoHS Compliant, Type: Type SE Style R, Voltage Rating: 600 VAC, Amperage Rating: 115 A, Number of Conductors: 4, Conductor Type: Stranded Aluminum, Conductor Size: 3 to 1 AWG, Outside Diameter: 1.082 in, Length: 1000 ft Reel, Strands: 8, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Gray, Temperature Rating: 90 deg C Compact stranded aluminum alloy 8000 series per ASTM-B800, ASTM-B801 and ASTM-B836, High dielectric strength, heat and moisture resistant, black or colored polyvinyl chloride (PVC) rated 90 deg C wet or dry, meeting the requirements or UL-83 for THHN or THWN-2 wire, A tough, polyamide, nylon outer covering per UL-83 Encore Wire Corp 739373885111
Country of Origin: USA, Package Length: 14, Package Height: 22, Package Width: 36, Package Weight: 566, Mfg Standards/Approvals: UL File E-174428, NEMA RV 4-2012, Reach, RoHS Compliant, Type: Type SE Style R, Voltage Rating: 600 VAC, Amperage Rating: 205 A, Number of Conductors: 4, Conductor Type: Stranded Aluminum, Conductor Size: 2/0 to 4/0 AWG, Outside Diameter: 1.425 in, Length: 500 ft Reel, Strands: 19, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Gray, Temperature Rating: 90 deg C Compact stranded aluminum alloy 8000 series per ASTM-B800, ASTM-B801 and ASTM-B836, High dielectric strength, heat and moisture resistant, black or colored polyvinyl chloride (PVC) rated 90 deg C wet or dry, meeting the requirements or UL-83 for THHN or THWN-2 wire, A tough, polyamide, nylon outer covering per UL-83 Encore Wire Corp 739373885227
Country of Origin: USA, Package Length: 5, Package Height: 11, Package Width: 18, Package Weight: 47, Mfg Standards/Approvals: UL Listed, Reach, RoHS Compliant, Conductor Type: Stranded Aluminum, Outside Diameter: 0.457 in, Number of Conductors: 2, Conductor Size: 6 AWG, Strands: 7x7, Insulation Material: Polyethylene, Jacket Material: PVC Coated, Temperature Rating: 90 deg C, Type: Duplex, Voltage Rating: 600 VAC, Amperage Rating: 110 A, Length: 500 ft Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Stranded aluminum conductor steel reinforced (ACSR), 1350 series alloy bare supporting neutral with steel support center wire per ASTM-B230, ASTM-B232 neutral conductor, Cross-linked polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 deg C wet or dry, Shepard code word, Duplex overhead service drop cable has one black XLPE insulated aluminum conductor cable around a bare stranded acsr 1350 series alloy supporting neutral with steel support center wire, Superior weather, abrasion, crush and sunlight resistant XLPE insulation Encore Wire Corp 739373935182
Country of Origin: USA, Package Length: 14, Package Height: 22, Package Width: 32, Package Weight: 338, Mfg Standards/Approvals: UL Listed, RUS Accepted, Reach, RoHS Compliant, Voltage Rating: 600 VAC, Temperature Rating: 90 deg C, Jacket Material: PVC, Insulation Material: Polyethylene, Strands: 7x7, Outside Diameter: 0.558 in, Conductor Type: Stranded Aluminum, Amperage Rating: 110 A, Type: Type ACSR Triplex, Conductor Size: 6 AWG, Number of Conductors: 3, Length: 2200 ft Reel Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 deg C wet or dry, Voluta code word Encore Wire Corp 739373935229
Country of Origin: USA, Package Length: 14, Package Height: 22, Package Width: 32, Package Weight: 329, Mfg Standards/Approvals: UL Listed, RUS Accepted, Reach, RoHS Compliant, Conductor Type: Stranded Aluminum, Temperature Rating: 90 deg C, Type: Type ACSR Triplex, Number of Conductors: 3, Outside Diameter: 0.653 in, Voltage Rating: 600 VAC, Amperage Rating: 115 A, Conductor Size: 4 AWG, Length: 1500 ft Reel, Strands: 7x7, Jacket Material: PVC, Insulation Material: Polyethylene Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 deg C wet or dry, Periwinkle code word Encore Wire Corp 739373935236
Country of Origin: USA, Package Length: 14, Package Height: 22, Package Width: 36, Package Weight: 558, Mfg Standards/Approvals: UL Listed, RUS Accepted, Reach, RoHS Compliant, Temperature Rating: 90 deg C, Type: Type ACSR Triplex, Length: 1800 ft Reel, Voltage Rating: 600 VAC, Amperage Rating: 150 A, Number of Conductors: 3, Conductor Type: Stranded Aluminum, Conductor Size: 2 AWG, Outside Diameter: 0.771 in, Strands: 7x7, Jacket Material: PVC, Insulation Material: Polyethylene Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 deg C wet or dry, Conch code word Encore Wire Corp 739373935243
Country of Origin: USA, Package Length: 16, Package Height: 23, Package Width: 42, Package Weight: 642, Mfg Standards/Approvals: UL Listed, RUS Accepted, Reach, RoHS Compliant, Conductor Size: 1/0 AWG, Temperature Rating: 90 deg C, Type: Type ACSR Triplex, Number of Conductors: 3, Outside Diameter: 0.98 in, Voltage Rating: 600 VAC, Amperage Rating: 200 A, Length: 1200 ft Reel, Strands: 10x7, Insulation Material: Polyethylene, Jacket Material: PVC, Conductor Type: Stranded Aluminum Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 deg C wet or dry, Neritina code word Encore Wire Corp 739373935250
Country of Origin: USA, Package Length: 16, Package Height: 23, Package Width: 48, Package Weight: 969, Mfg Standards/Approvals: UL Listed, RUS Accepted, Reach, RoHS Compliant, Type: Type ACSR Triplex, Temperature Rating: 90 deg C, Outside Diameter: 1.066 in, Voltage Rating: 600 VAC, Amperage Rating: 230 A, Conductor Type: Stranded Aluminum, Conductor Size: 2/0 AWG, Length: 1500 ft Reel, Strands: 12x7, Insulation Material: Polyethylene, Jacket Material: PVC, Number of Conductors: 3 Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 deg C wet or dry, Runcina code word Encore Wire Corp 739373935267
Country of Origin: USA, Mfg Standards/Approvals: UL Listed, Reach, RoHS Compliant, Conductor Size: 4 AWG, Temperature Rating: 90 deg C, Voltage Rating: 600 VAC, Jacket Material: PVC Coated, Insulation Material: Polyethylene, Strands: 7x7, Length: 500 ft, Amperage Rating: 135 A, Type: Quadplex, Outside Diameter: 0.729 in, Conductor Type: Stranded Aluminum, Number of Conductors: 4 Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Stranded aluminum conductor steel reinforced (ACSR), 1350 series alloy bare supporting neutral with steel support center wire per ASTM-B230, ASTM-B232 neutral conductor, Cross-linked polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 deg C wet or dry, Hackney code word, Quadruplex overhead service drop cable has three black XLPE insulated aluminum conductor cable around a bare stranded acsr 1350 series alloy supporting neutral with steel support center wire, Superior weather, abrasion, crush and sunlight resistant XLPE insulation Encore Wire Corp 739373936165
Country of Origin: USA, Package Length: 14.0, Package Height: 18.0, Package Width: 30.0, Package Weight: 210.0, Mfg Standards/Approvals: UL Listed, Reach, RoHS Compliant, Application: For energy distribution, Temperature Rating: 90, Amperage Rating: 175, Voltage Rating: 600, Outside Diameter: 0.861, Length: 500, Conductor Type: Stranded Aluminum, Insulation Material: Polyethylene, Strands: 7x7, Conductor Size: 2 AWG, Jacket Material: PVC Coated, Number of Conductors: 4, Type: Quadplex Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Stranded aluminum conductor steel reinforced (ACSR), 1350 series alloy bare supporting neutral with steel support center wire per ASTM-B230, ASTM-B232 neutral conductor, Cross-linked polyethylene (XLPE) black insulation per ANSI/ICEA S-76-474, rated 90 deg C wet or dry, Palomino code word, Quadruplex overhead service drop cable has three black XLPE insulated aluminum conductor cable around a bare stranded acsr 1350 series alloy supporting neutral with steel support center wire, Superior weather, abrasion, crush and sunlight resistant XLPE insulation Encore Wire Corp 739373935311
Country of Origin: USA, Package Length: 14, Package Height: 22, Package Width: 32, Package Weight: 342, Mfg Standards/Approvals: UL File E-174428, RUS Accepted, Reach, RoHS Compliant, Voltage Rating: 600 VAC, Insulation Material: Polyethylene, Temperature Rating: 90 deg C, Jacket Color: Black, Strands: 7x7x6, Length: 1000 ft, Outside Diameter: 0.95 in, Conductor Size: 6 to 2 AWG, Amperage Rating: 100 A, Number of Conductors: 4, Conductor Type: Stranded Aluminum Compact stranded aluminum alloy 8000 series per ASTM-B800, ASTM-B801 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854, UL-44 and ANSI/ICEA S-105-692, Black XLPE insulation or phase conductors, white XLPE or neutral conductor, green XLPE or ground Encore Wire Corp 739373887009
Country of Origin: USA, Package Length: 16, Package Height: 23, Package Width: 48, Package Weight: 912, Mfg Standards/Approvals: UL File E-174428, RUS Accepted, Reach, RoHS Compliant, Length: 1000 ft, Outside Diameter: 1.55 in, Voltage Rating: 600 VAC, Amperage Rating: 200 A, Number of Conductors: 4, Conductor Type: Stranded Aluminum, Conductor Size: 4/0 to 2/0 to 4 AWG, Strands: 19x12x6, Insulation Material: Polyethylene, Jacket Color: Black, Temperature Rating: 90 deg C Compact stranded aluminum alloy 8000 series per ASTM-B800, ASTM-B801 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854, UL-44 and ANSI/ICEA S-105-692, Black XLPE insulation or phase conductors, white XLPE or neutral conductor, green XLPE or ground Encore Wire Corp 739373887030
Country of Origin: USA, Package Length: 14, Package Height: 18, Package Width: 30, Package Weight: 219, Mfg Standards/Approvals: UL File E-174428, RUS Accepted, Reach, RoHS Compliant, Jacket Color: Black/Yellow, Temperature Rating: 90 deg C, Length: 1000 ft, Conductor Size: 4 AWG, Conductor Type: Stranded Aluminum, Number of Conductors: 3, Voltage Rating: 600 VAC, Type: Triplex, Jacket Material: PVC Coated, Strands: 7, Outside Diameter: 0.333 in, Amperage Rating: 130 A, Insulation Material: Polyethylene Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854 and ANSI/ICEA S-105-692, black XLPE insulation or phase conductors, yellow XLPE insulation or grounded (neutral) conductor, Vassar code word Encore Wire Corp 739373923844
Country of Origin: USA, Package Length: 14, Package Height: 22, Package Width: 36, Package Weight: 496, Mfg Standards/Approvals: UL File E-174428, RUS Accepted, Reach, RoHS Compliant, Jacket Material: PVC Coated, Temperature Rating: 90 deg C, Length: 1000 ft, Outside Diameter: 0.496 in, Conductor Size: 1/0 AWG, Conductor Type: Stranded Aluminum, Number of Conductors: 3, Amperage Rating: 219 A, Voltage Rating: 600 VAC, Jacket Color: Black/Yellow, Strands: 10, Type: Triplex, Insulation Material: Polyethylene Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854 and ANSI/ICEA S-105-692, black XLPE insulation or phase conductors, yellow XLPE insulation or grounded (neutral) conductor, Bergen code word Encore Wire Corp 739373923905
Country of Origin: USA, Package Length: 16, Package Height: 23, Package Width: 42, Package Weight: 665, Mfg Standards/Approvals: UL File E-174428, RUS Accepted, Reach, RoHS Compliant, Jacket Color: Black/Yellow, Insulation Material: Polyethylene, Conductor Type: Stranded Aluminum, Number of Conductors: 3, Voltage Rating: 600 VAC, Jacket Material: PVC Coated, Strands: 12, Outside Diameter: 0.536 in, Amperage Rating: 249 A, Type: Triplex, Length: 1000 ft, Conductor Size: 2/0 AWG, Temperature Rating: 90 deg C Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854 and ANSI/ICEA S-105-692, black XLPE insulation or phase conductors, yellow XLPE insulation or grounded (neutral) conductor, Hunter code word Encore Wire Corp 739373926517
Country of Origin: USA, Package Length: 16, Package Height: 23, Package Width: 48, Package Weight: 926, Mfg Standards/Approvals: UL File E-174428, RUS Accepted, Reach, RoHS Compliant, Length: 1000 ft, Insulation Material: Polyethylene, Temperature Rating: 90 deg C, Jacket Material: PVC Coated, Strands: 19, Conductor Size: 4/0 AWG, Conductor Type: Stranded Aluminum, Amperage Rating: 322 A, Voltage Rating: 600 VAC, Type: Triplex, Jacket Color: Black/Yellow, Outside Diameter: 0.635 in, Number of Conductors: 3 Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854 and ANSI/ICEA S-105-692, black XLPE insulation or phase conductors, yellow XLPE insulation or grounded (neutral) conductor, Monmouth code word Encore Wire Corp 739373923936
Country of Origin: USA, Package Length: 14, Package Height: 22, Package Width: 32, Package Weight: 296, Mfg Standards/Approvals: UL File E-174428, RUS Accepted, Reach, RoHS Compliant, Length: 1000 ft, Temperature Rating: 90 deg C, Jacket Material: PVC Coated, Insulation Material: Polyethylene, Strands: 7, Outside Diameter: 0.388 in, Conductor Type: Stranded Aluminum, Number of Conductors: 3, Amperage Rating: 168 A, Voltage Rating: 600 VAC, Type: Triplex, Conductor Size: 2 AWG, Jacket Color: Black/Yellow Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854 and ANSI/ICEA S-105-692, black XLPE insulation or phase conductors, yellow XLPE insulation or grounded (neutral) conductor, Stephens code word Encore Wire Corp 739373924124
Country of Origin: USA, Package Length: 14, Package Height: 18, Package Width: 30, Package Weight: 217, Mfg Standards/Approvals: UL File E-174428, RUS Accepted, Reach, RoHS Compliant, Temperature Rating: 90 deg C, Length: 500 ft, Outside Diameter: 0.496 in, Strands: 10, Jacket Material: PVC Coated, Type: Triplex, Voltage Rating: 600 VAC, Amperage Rating: 219 A, Number of Conductors: 3, Conductor Type: Stranded Aluminum, Conductor Size: 1/0 AWG, Insulation Material: Polyethylene, Jacket Color: Black/Yellow Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854 and ANSI/ICEA S-105-692, black XLPE insulation or phase conductors, yellow XLPE insulation or grounded (neutral) conductor, Brenau code word Encore Wire Corp 739373925176
Country of Origin: USA, Package Length: 14, Package Height: 22, Package Width: 36, Package Weight: 444, Mfg Standards/Approvals: UL File E-174428, RUS Accepted, Reach, RoHS Compliant, Jacket Material: PVC Coated, Strands: 10, Outside Diameter: 0.496 in, Amperage Rating: 219 A, Insulation Material: Polyethylene, Conductor Type: Stranded Aluminum, Type: Triplex, Temperature Rating: 90 deg C, Jacket Color: Black/Yellow, Length: 1000 ft, Conductor Size: 1/0 AWG, Number of Conductors: 3, Voltage Rating: 600 VAC Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854 and ANSI/ICEA S-105-692, black XLPE insulation or phase conductors, yellow XLPE insulation or grounded (neutral) conductor, Brenau code word Encore Wire Corp 739373924209
Country of Origin: USA, Package Length: 14, Package Height: 22, Package Width: 36, Package Weight: 547, Mfg Standards/Approvals: UL File E-174428, RUS Accepted, Reach, RoHS Compliant, Conductor Type: Stranded Aluminum, Temperature Rating: 90 deg C, Number of Conductors: 3, Outside Diameter: 0.536 in, Jacket Color: Black/Yellow, Type: Triplex, Jacket Material: PVC Coated, Insulation Material: Polyethylene, Strands: 12, Length: 1000 ft, Conductor Size: 2/0 AWG, Amperage Rating: 249 A, Voltage Rating: 600 VAC Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854 and ANSI/ICEA S-105-692, black XLPE insulation or phase conductors, yellow XLPE insulation or grounded (neutral) conductor, Converse code word Encore Wire Corp 739373924148
Country of Origin: USA, Package Length: 16, Package Height: 23, Package Width: 42, Package Weight: 819, Mfg Standards/Approvals: UL File E-174428, RUS Accepted, Reach, RoHS Compliant, Type: Triplex, Voltage Rating: 600 VAC, Amperage Rating: 322 A, Number of Conductors: 3, Conductor Type: Stranded Aluminum, Conductor Size: 4/0 AWG, Outside Diameter: 0.08 in, Length: 1000 ft, Strands: 19, Insulation Material: Polyethylene, Jacket Material: PVC Coated, Jacket Color: Black/Yellow, Temperature Rating: 90 deg C Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854 and ANSI/ICEA S-105-692, black XLPE insulation or phase conductors, yellow XLPE insulation or grounded (neutral) conductor, Sweetbriar code word Encore Wire Corp 739373923967
Country of Origin: USA, Package Length: 16, Package Height: 23, Package Width: 48, Package Weight: 981, Mfg Standards/Approvals: UL File E-174428, RUS Accepted, Reach, RoHS Compliant, Insulation Material: Polyethylene, Temperature Rating: 90 deg C, Conductor Size: 250 kcmil, Conductor Type: Stranded Aluminum, Amperage Rating: 356 A, Voltage Rating: 600 VAC, Type: Triplex, Jacket Color: Black/Yellow, Outside Diameter: 0.71 in, Number of Conductors: 3, Length: 1000 ft, Jacket Material: PVC Coated, Strands: 22 Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854 and ANSI/ICEA S-105-692, black XLPE insulation or phase conductors, yellow XLPE insulation or grounded (neutral) conductor, Pratt code word Encore Wire Corp 739373924162
Country of Origin: USA, Package Length: 16, Package Height: 23, Package Width: 42, Package Weight: 676, Mfg Standards/Approvals: UL File E-174428, RUS Accepted, Reach, RoHS Compliant, Jacket Color: Black/Yellow, Temperature Rating: 90 deg C, Length: 500 ft, Conductor Size: 350 kcmil, Conductor Type: Stranded Aluminum, Number of Conductors: 3, Voltage Rating: 600 VAC, Jacket Material: PVC Coated, Strands: 24, Outside Diameter: 0.806 in, Amperage Rating: 431 A, Type: Triplex, Insulation Material: Polyethylene Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854 and ANSI/ICEA S-105-692, black XLPE insulation or phase conductors, yellow XLPE insulation or grounded (neutral) conductor, Wesleyan code word Encore Wire Corp 739373926357
Country of Origin: USA, Package Length: 28, Package Height: 32, Package Width: 54, Package Weight: 1405, Mfg Standards/Approvals: UL File E-174428, RUS Accepted, Reach, RoHS Compliant, Length: 1000 ft, Conductor Size: 350 kcmil, Conductor Type: Stranded Aluminum, Number of Conductors: 3, Voltage Rating: 600 VAC, Type: Triplex, Temperature Rating: 90 deg C, Jacket Material: PVC Coated, Strands: 24, Outside Diameter: 0.806 in, Amperage Rating: 431 A, Jacket Color: Black/Yellow, Insulation Material: Polyethylene Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854 and ANSI/ICEA S-105-692, black XLPE insulation or phase conductors, yellow XLPE insulation or grounded (neutral) conductor, Wesleyan code word Encore Wire Corp 739373926364
Country of Origin: USA, Package Length: 14.75, Package Height: 14.75, Package Width: 7.5, Package Weight: 36, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC-LED-AL, Voltage Rating: 600 VAC, Number of Conductors: 5, Conductor Type: Ground Solid Aluminum, Conductor Size: 12 AWG, Length: 250 ft, Jacket Material: PVC Black/white conductor color, Interlocked aluminum armor is applied over the assembly Encore Wire Corp 739373959270
Country of Origin: USA, Package Length: 14.75, Package Height: 14.75, Package Width: 7.5, Package Weight: 44.0, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Application: For commercial applications, Voltage Rating: 600, Length: 250, Type: Type MC-LED-AL, Number of Conductors: 5, Conductor Type: Ground Solid Aluminum, Conductor Size: 12 AWG, Jacket Material: PVC Black/white/red conductor color, Interlocked aluminum armor is applied over the assembly Encore Wire Corp 739373959515
Country of Origin: USA, Package Length: 16, Package Height: 23, Package Width: 42, Package Weight: 641, Mfg Standards/Approvals: UL File E-174428, Reach, RoHS Compliant, Amperage Rating: 198 A, Outside Diameter: 0.496 in, Jacket Material: PVC Coated, Type: Quadplex, Voltage Rating: 600 VAC, Number of Conductors: 4, Conductor Size: 1/0 AWG, Length: 1000 ft, Strands: 10, Insulation Material: Polyethylene, Temperature Rating: 90 deg C, Conductor Type: Stranded Aluminum, Jacket Color: Black/Yellow Compact stranded aluminum alloy 1350 series per ASTM-B230, ASTM-B231, ASTM-B609 and ASTM-B836, Cross-linked polyethylene (XLPE) insulation per UL-854 and ANSI/ICEA S-105-692, black XLPE insulation or phase conductors, yellow XLPE insulation or grounded (neutral) conductor, Notre dame code word Encore Wire Corp 739373887184
Country of Origin: USA, Package Length: 14.75, Package Height: 14.75, Package Width: 7.5, Package Weight: 17, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 15 A, Number of Conductors: 4, Conductor Type: Ground Stranded Aluminum, Conductor Size: 14 AWG, Length: 125 ft, Temperature Rating: 90 deg C Black/white/red conductor color Encore Wire Corp 739373947222
Country of Origin: USA, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 15 A, Number of Conductors: 3, Conductor Type: Ground Solid Aluminum, Conductor Size: 14 AWG, Length: 250 ft, Temperature Rating: 90 deg C Black/white conductor color Encore Wire Corp 739373739988
Country of Origin: USA, Package Length: 14, Package Height: 14, Package Width: 7, Package Weight: 25, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Ground Solid Aluminum, Conductor Size: 12 AWG, Length: 250 ft, Temperature Rating: 90 deg C Black/white conductor color Encore Wire Corp 739373738394
Country of Origin: USA, Package Length: 10, Package Height: 12, Package Width: 24, Package Weight: 117, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Ground Solid Aluminum, Conductor Size: 12 AWG, Length: 1000 ft, Temperature Rating: 90 deg C Black/white conductor color Encore Wire Corp 739373740007
Country of Origin: USA, Package Length: 10, Package Height: 12, Package Width: 24, Package Weight: 117, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Ground Solid Aluminum, Conductor Size: 12 AWG, Length: 1000 ft, Temperature Rating: 90 deg C Red/white conductor color Encore Wire Corp 739373740045
Country of Origin: USA, Package Length: 10, Package Height: 12, Package Width: 24, Package Weight: 117, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Ground Solid Aluminum, Conductor Size: 12 AWG, Length: 1000 ft, Temperature Rating: 90 deg C Blue/white conductor color Encore Wire Corp 739373740069
Country of Origin: USA, Package Length: 7, Package Height: 7, Package Width: 14, Package Weight: 25, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Ground Solid Aluminum, Conductor Size: 12 AWG, Length: 250 ft, Temperature Rating: 90 deg C Yellow/gray conductor color Encore Wire Corp 739373740076
Country of Origin: USA, Package Length: 7, Package Height: 7, Package Width: 14, Package Weight: 25, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Ground Solid Aluminum, Conductor Size: 12 AWG, Length: 250 ft, Temperature Rating: 90 deg C Orange/gray conductor color Encore Wire Corp 739373740090
Country of Origin: USA, Package Length: 7, Package Height: 7, Package Width: 14, Package Weight: 25, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Ground Solid Aluminum, Conductor Size: 12 AWG, Length: 250 ft, Temperature Rating: 90 deg C Brown/gray conductor color Encore Wire Corp 739373740113
Country of Origin: USA, Package Length: 7, Package Height: 7, Package Width: 14, Package Weight: 36, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 3, Conductor Type: Ground Solid Aluminum, Conductor Size: 10 AWG, Length: 250 ft, Temperature Rating: 90 deg C Black/white conductor color Encore Wire Corp 739373740151
Country of Origin: USA, Package Length: 10, Package Height: 12, Package Width: 24, Package Weight: 159, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 3, Conductor Type: Ground Solid Aluminum, Conductor Size: 10 AWG, Length: 1000 ft, Temperature Rating: 90 deg C Black/white conductor color Encore Wire Corp 739373740168
Country of Origin: USA, Package Length: 7, Package Height: 7, Package Width: 14, Package Weight: 31, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 4, Conductor Type: Ground Solid Aluminum, Conductor Size: 12 AWG, Length: 250 ft, Temperature Rating: 90 deg C Black/white/red conductor color Encore Wire Corp 739373740311
Country of Origin: USA, Package Length: 10, Package Height: 12, Package Width: 24, Package Weight: 138, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 4, Conductor Type: Ground Solid Aluminum, Conductor Size: 12 AWG, Length: 1000 ft, Temperature Rating: 90 deg C Black/white/red conductor color Encore Wire Corp 739373740328
Country of Origin: USA, Package Length: 15, Package Height: 15, Package Width: 8, Package Weight: 46, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 4, Conductor Type: Ground Solid Aluminum, Conductor Size: 10 AWG, Length: 250 ft, Temperature Rating: 90 deg C Black/white/red conductor color Encore Wire Corp 739373740434
Country of Origin: USA, Package Length: 12, Package Height: 16, Package Width: 24, Package Weight: 207, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 4, Conductor Type: Ground Solid Aluminum, Conductor Size: 10 AWG, Length: 1000 ft, Temperature Rating: 90 deg C Black/white/red conductor color Encore Wire Corp 739373740441
Country of Origin: USA, Package Length: 14.75, Package Height: 14.75, Package Width: 7.5, Package Weight: 37, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 5, Conductor Type: Ground Solid Aluminum, Conductor Size: 12 AWG, Length: 250 ft, Temperature Rating: 90 deg C Black/white/red/blue conductor color Encore Wire Corp 739373740533
Country of Origin: USA, Package Length: 10, Package Height: 12, Package Width: 24, Package Weight: 163, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 5, Conductor Type: Ground Solid Aluminum, Conductor Size: 12 AWG, Length: 1000 ft, Temperature Rating: 90 deg C Black/white/red/blue conductor color Encore Wire Corp 739373740540
Country of Origin: USA, Package Length: 7, Package Height: 7, Package Width: 14, Package Weight: 26, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Ground Stranded Aluminum, Conductor Size: 12 AWG, Length: 250 ft, Temperature Rating: 90 deg C Black/white conductor color Encore Wire Corp 739373740618
Country of Origin: USA, Package Length: 12, Package Height: 16, Package Width: 24, Package Weight: 127, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 55 A, Number of Conductors: 3, Conductor Type: Ground Stranded Aluminum, Conductor Size: 8 AWG, Length: 500 ft, Temperature Rating: 90 deg C Black/white conductor color Encore Wire Corp 739373740885
Country of Origin: USA, Package Length: 12, Package Height: 16, Package Width: 24, Package Weight: 179, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 75 A, Number of Conductors: 3, Conductor Type: Ground Stranded Aluminum, Conductor Size: 6 AWG, Length: 500 ft, Temperature Rating: 90 deg C Black/white conductor color Encore Wire Corp 739373740953
Country of Origin: USA, Package Length: 7, Package Height: 7, Package Width: 14, Package Weight: 32, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 4, Conductor Type: Ground Stranded Aluminum, Conductor Size: 12 AWG, Length: 250 ft, Temperature Rating: 90 deg C Black/white/red conductor color Encore Wire Corp 739373741004
Country of Origin: USA, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC-AL-MN, Voltage Rating: 600 VAC, Number of Conductors: 5, Conductor Type: Solid Aluminum, Conductor Size: 12 AWG, Length: 250 ft Black/red conductor color, Interlocked aluminum armor is applied over the assembly, Multi neutral special construction Encore Wire Corp 739373908216
Country of Origin: USA, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC-AL-ISG, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 4, Conductor Type: Ground Solid Aluminum, Conductor Size: 12 AWG, Outside Diameter: 0.527 in, Length: 250 ft, Temperature Rating: 90 deg C Black/white conductor color, Encore metal clad cable is constructed with soft drawn copper, type THHN/THWN-2 conductor rated 90 deg C dry locations, All conductor are cable together with a separator tape containing the identification print legend to for the cable core, Interlocked aluminum armor is applied over the assembly Encore Wire Corp 739373742636
Country of Origin: USA, Package Length: 14.75, Package Height: 14.75, Package Width: 7.5, Package Weight: 23, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 2, Conductor Type: Solid Aluminum, Conductor Size: 12 AWG, Length: 250 ft, Temperature Rating: 90 deg C Black/white conductor color, Self grounding, a faster and more convenient way to install MC cable, Contains a aluminum bond wire that remains is constant contact with the metal sheathing, whereby the sheathing itself becomes part or the grounding path, Provide lower installation cost when compared to traditional conduit and wire, aluminum interlocked sheathing and MC SmartGround can reduce installation time even more by eliminating the additional step or terminating the ground Encore Wire Corp 739373879813
Country of Origin: USA, Package Length: 14.75, Package Height: 14.75, Package Width: 7.5, Package Weight: 33, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 2, Conductor Type: Solid Aluminum, Conductor Size: 10 AWG, Length: 250 ft, Temperature Rating: 90 deg C Black/white conductor color, Self grounding, a faster and more convenient way to install MC cable, Contains a aluminum bond wire that remains is constant contact with the metal sheathing, whereby the sheathing itself becomes part or the grounding path, Provide lower installation cost when compared to traditional conduit and wire, aluminum interlocked sheathing and MC SmartGround can reduce installation time even more by eliminating the additional step or terminating the ground Encore Wire Corp 739373879974
Country of Origin: USA, Package Length: 14.75, Package Height: 14.75, Package Width: 7.5, Package Weight: 30, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Solid Aluminum, Conductor Size: 12 AWG, Length: 250 ft, Temperature Rating: 90 deg C Black/white/red conductor color, Self grounding, a faster and more convenient way to install MC cable, Contains a aluminum bond wire that remains is constant contact with the metal sheathing, whereby the sheathing itself becomes part or the grounding path, Provide lower installation cost when compared to traditional conduit and wire, aluminum interlocked sheathing and MC SmartGround can reduce installation time even more by eliminating the additional step or terminating the ground Encore Wire Corp 739373880253
Country of Origin: USA, Package Length: 14.75, Package Height: 14.75, Package Width: 7.5, Package Weight: 37, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 4, Conductor Type: Solid Aluminum, Conductor Size: 12 AWG, Length: 250 ft, Temperature Rating: 90 deg C Black/white/red/blue conductor color, Self grounding, a faster and more convenient way to install MC cable, Contains a aluminum bond wire that remains is constant contact with the metal sheathing, whereby the sheathing itself becomes part or the grounding path, Provide lower installation cost when compared to traditional conduit and wire, aluminum interlocked sheathing and MC SmartGround can reduce installation time even more by eliminating the additional step or terminating the ground Encore Wire Corp 739373880550
Country of Origin: USA, Package Length: 12, Package Height: 16, Package Width: 24, Package Weight: 170, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 4, Conductor Type: Solid Aluminum, Conductor Size: 12 AWG, Length: 1000 ft, Temperature Rating: 90 deg C Black/white/red/blue conductor color, Self grounding, a faster and more convenient way to install MC cable, Contains a aluminum bond wire that remains is constant contact with the metal sheathing, whereby the sheathing itself becomes part or the grounding path, Provide lower installation cost when compared to traditional conduit and wire, aluminum interlocked sheathing and MC SmartGround can reduce installation time even more by eliminating the additional step or terminating the ground Encore Wire Corp 739373880567
Country of Origin: USA, Package Length: 14.75, Package Height: 14.75, Package Width: 7.5, Package Weight: 30, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC HCF-SG, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Solid Aluminum, Conductor Size: 12 AWG, Outside Diameter: 0.515 in, Length: 250 ft, Temperature Rating: 90 deg C Black/white conductor color, Encore metal clad cable is constructed with soft drawn copper, type THHN/THWN conductor rated 90 deg C dry locations, All conductor are individually wrapped with flame retardant colored protective paper with print legend and cable together to for the cable core, Interlocked aluminum armor is applied over the assembly Encore Wire Corp 739373881724
Country of Origin: USA, Package Length: 14.75, Package Height: 14.75, Package Width: 7.5, Package Weight: 30, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC HCF-SG, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Solid Aluminum, Conductor Size: 12 AWG, Outside Diameter: 0.515 in, Length: 250 ft, Temperature Rating: 90 deg C Red/white conductor color, Encore metal clad cable is constructed with soft drawn copper, type THHN/THWN conductor rated 90 deg C dry locations, All conductor are individually wrapped with flame retardant colored protective paper with print legend and cable together to for the cable core, Interlocked aluminum armor is applied over the assembly Encore Wire Corp 739373881755
Country of Origin: USA, Package Length: 14.75, Package Height: 14.75, Package Width: 7.5, Package Weight: 30, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC HCF-SG, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Solid Aluminum, Conductor Size: 12 AWG, Outside Diameter: 0.515 in, Length: 250 ft, Temperature Rating: 90 deg C Blue/white conductor color, Encore metal clad cable is constructed with soft drawn copper, type THHN/THWN conductor rated 90 deg C dry locations, All conductor are individually wrapped with flame retardant colored protective paper with print legend and cable together to for the cable core, Interlocked aluminum armor is applied over the assembly Encore Wire Corp 739373881779
Country of Origin: USA, Package Length: 14.75, Package Height: 14.75, Package Width: 7.5, Package Weight: 37, Mfg Standards/Approvals: UL File E-301130, Reach, RoHS Compliant, Type: Type MC HCF-SG, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 4, Conductor Type: Solid Aluminum, Conductor Size: 12 AWG, Outside Diameter: 0.57 in, Length: 250 ft, Temperature Rating: 90 deg C Black/white/red conductor color, Encore metal clad cable is constructed with soft drawn copper, type THHN/THWN conductor rated 90 deg C dry locations, All conductor are individually wrapped with flame retardant colored protective paper with print legend and cable together to for the cable core, Interlocked aluminum armor is applied over the assembly Encore Wire Corp 739373881984
Country of Origin: USA, Package Length: 5, Package Height: 11, Package Width: 15, Package Weight: 85, Mfg Standards/Approvals: UL File E-123775, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type NM-B, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Solid Ground Copper, Conductor Size: 12 AWG, Outside Diameter: 0.16 x 0.45 in, Length: 1000 ft Reel, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Yellow, Temperature Rating: 90 deg C Color code polyvinyl chloride compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Solid 14 to 10 AWG soft, uncoated copper conductor per ASTM-B3, Soft, uncoated copper grounding conductor per ASTM-B3 or ASTM-B8, A 30 mil, color coded, flame retardant and moisture resistant PVC jacket is applied over the completed assembly Encore Wire Corp 739373003089
Country of Origin: USA, Package Length: 5, Package Height: 14, Package Width: 24, Package Weight: 340, Mfg Standards/Approvals: UL File E-123775, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type NM-B, Voltage Rating: 600 VAC, Amperage Rating: 20 A, Number of Conductors: 3, Conductor Type: Solid Ground Copper, Conductor Size: 12 AWG, Outside Diameter: 0.16 x 0.45 in, Length: 4000 ft Reel, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Yellow, Temperature Rating: 90 deg C Color code polyvinyl chloride compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Solid 14 to 10 AWG soft, uncoated copper conductor per ASTM-B3, Soft, uncoated copper grounding conductor per ASTM-B3 or ASTM-B8, A 30 mil, color coded, flame retardant and moisture resistant PVC jacket is applied over the completed assembly Encore Wire Corp 739373003096
Country of Origin: USA, Package Length: 10, Package Height: 12, Package Width: 24, Package Weight: 205, Mfg Standards/Approvals: UL File E-123775, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type NM-B, Voltage Rating: 600 VAC, Amperage Rating: 40 A, Number of Conductors: 3, Conductor Type: Ground Copper, Conductor Size: 8 AWG, Outside Diameter: 0.29 x 0.58 in, Length: 1000 ft Reel, Strands: 7, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Black, Temperature Rating: 90 deg C Color code polyvinyl chloride compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Stranded 8 AWG conductor and larger uncoated per ASTM-B8, Soft, uncoated copper grounding conductor per ASTM-B3 or ASTM-B8, A 30 mil, color coded, flame retardant and moisture resistant PVC jacket is applied over the completed assembly Encore Wire Corp 739373007087
Country of Origin: USA, Package Length: 10, Package Height: 12, Package Width: 24, Package Weight: 261, Mfg Standards/Approvals: UL File E-123775, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type NM-B, Voltage Rating: 600 VAC, Amperage Rating: 55 A, Number of Conductors: 3, Conductor Type: Ground Copper, Conductor Size: 6 AWG, Outside Diameter: 0.33 x 0.695 in, Length: 1000 ft Reel, Strands: 7, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Black, Temperature Rating: 90 deg C Color code polyvinyl chloride compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Stranded 8 AWG conductor and larger uncoated per ASTM-B8, Soft, uncoated copper grounding conductor per ASTM-B3 or ASTM-B8, A 30 mil, color coded, flame retardant and moisture resistant PVC jacket is applied over the completed assembly Encore Wire Corp 739373009081
Country of Origin: USA, Package Length: 10, Package Height: 12, Package Width: 24, Package Weight: 266, Mfg Standards/Approvals: UL File E-123775, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type NM-B, Voltage Rating: 600 VAC, Amperage Rating: 40 A, Number of Conductors: 4, Conductor Type: Ground Copper, Conductor Size: 8 AWG, Outside Diameter: 0.555 in, Length: 1000 ft Reel, Strands: 7, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Black, Temperature Rating: 90 deg C Color code polyvinyl chloride compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Stranded 8 AWG conductor and larger uncoated per ASTM-B8, Soft, uncoated copper grounding conductor per ASTM-B3 or ASTM-B8, A 30 mil, color coded, flame retardant and moisture resistant PVC jacket is applied over the completed assembly Encore Wire Corp 739373021083
Country of Origin: USA, Package Length: 13.75, Package Height: 13.75, Package Width: 4, Package Weight: 66, Mfg Standards/Approvals: UL File E-123775, NEMA RV 2-2011, Reach, RoHS Compliant, Type: Type NM-B, Voltage Rating: 600 VAC, Amperage Rating: 70 A, Number of Conductors: 4, Conductor Type: Ground Copper, Conductor Size: 4 AWG, Outside Diameter: 0.82 in, Length: 125 ft EZ Pack, Strands: 7, Insulation Material: PVC, Jacket Material: PVC, Jacket Color: Black, Temperature Rating: 90 deg C Color code polyvinyl chloride compound meeting the required thickness or type THHN or THWN-2 with a heat stabilized nylon jacket rated for 90 deg C is dry locations, Stranded 8 AWG conductor and larger uncoated per ASTM-B8, Soft, uncoated copper grounding conductor per ASTM-B3 or ASTM-B8, A 30 mil, color coded, flame retardant and moisture resistant PVC jacket is applied over the completed assembly Encore Wire Corp 739373025067
Country of Origin: USA, Mfg Standards/Approvals: ARRA, Buy American Act, Reach, RoHS Compliant, UL File E-123774, E-156878, E-156879, cUL Listed, Type: Type THHN, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 1, Conductor Type: Solid Copper, Conductor Size: 12 AWG, Outside Diameter: 0.128 in, Length: 1000 ft, Strands: 19, Insulation Material: PVC, Jacket Material: Nylon, Jacket Color: Black, Temperature Rating: 90 deg C Color code polyvinyl chloride, heat and moisture resistant, flame retardant compound, Stranded, uncoated bare copper per ASTM-B3, ASTM-B8 and ASTM-B787, A tough, polyamide, nylon outer covering per UL-83 and UL-1063 Encore Wire Corp 739373948229
Country of Origin: USA, Package Length: 5, Package Height: 8, Package Width: 12, Package Weight: 60, Mfg Standards/Approvals: ARRA, Buy American Act, Reach, RoHS Compliant, UL File E-123774, E-156878, E-156879, cUL Listed, Type: Type THHN, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 1, Conductor Type: Solid Copper, Conductor Size: 12 AWG, Outside Diameter: 0.128 in, Length: 2500 ft Reel, Strands: 19, Insulation Material: PVC, Jacket Material: Nylon, Jacket Color: Black, Temperature Rating: 90 deg C Color code polyvinyl chloride, heat and moisture resistant, flame retardant compound, Stranded, uncoated bare copper per ASTM-B3, ASTM-B8 and ASTM-B787, A tough, polyamide, nylon outer covering per UL-83 and UL-1063 Encore Wire Corp 739373079152
Country of Origin: USA, Mfg Standards/Approvals: ARRA, Buy American Act, Reach, RoHS Compliant, UL File E-123774, E-156878, E-156879, cUL Listed, Type: Type THHN, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 1, Conductor Type: Solid Copper, Conductor Size: 12 AWG, Outside Diameter: 0.128 in, Length: 1000 ft, Strands: 19, Insulation Material: PVC, Jacket Material: Nylon, Jacket Color: White, Temperature Rating: 90 deg C Color code polyvinyl chloride, heat and moisture resistant, flame retardant compound, Stranded, uncoated bare copper per ASTM-B3, ASTM-B8 and ASTM-B787, A tough, polyamide, nylon outer covering per UL-83 and UL-1063 Encore Wire Corp 739373948236
Country of Origin: USA, Package Length: 5, Package Height: 8, Package Width: 12, Package Weight: 60, Mfg Standards/Approvals: ARRA, Buy American Act, Reach, RoHS Compliant, UL File E-123774, E-156878, E-156879, cUL Listed, Type: Type THHN, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 1, Conductor Type: Solid Copper, Conductor Size: 12 AWG, Outside Diameter: 0.128 in, Length: 2500 ft Reel, Strands: 19, Insulation Material: PVC, Jacket Material: Nylon, Jacket Color: White, Temperature Rating: 90 deg C Color code polyvinyl chloride, heat and moisture resistant, flame retardant compound, Stranded, uncoated bare copper per ASTM-B3, ASTM-B8 and ASTM-B787, A tough, polyamide, nylon outer covering per UL-83 and UL-1063 Encore Wire Corp 739373079251
Country of Origin: USA, Mfg Standards/Approvals: ARRA, Buy American Act, Reach, RoHS Compliant, UL File E-123774, E-156878, E-156879, cUL Listed, Type: Type THHN, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 1, Conductor Type: Solid Copper, Conductor Size: 12 AWG, Outside Diameter: 0.128 in, Length: 1000 ft, Strands: 19, Insulation Material: PVC, Jacket Material: Nylon, Jacket Color: Red, Temperature Rating: 90 deg C Color code polyvinyl chloride, heat and moisture resistant, flame retardant compound, Stranded, uncoated bare copper per ASTM-B3, ASTM-B8 and ASTM-B787, A tough, polyamide, nylon outer covering per UL-83 and UL-1063 Encore Wire Corp 739373948243
Country of Origin: USA, Package Length: 5, Package Height: 8, Package Width: 12, Package Weight: 60, Mfg Standards/Approvals: ARRA, Buy American Act, Reach, RoHS Compliant, UL File E-123774, E-156878, E-156879, cUL Listed, Type: Type THHN, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 1, Conductor Type: Solid Copper, Conductor Size: 12 AWG, Outside Diameter: 0.128 in, Length: 2500 ft Reel, Strands: 19, Insulation Material: PVC, Jacket Material: Nylon, Jacket Color: Red, Temperature Rating: 90 deg C Color code polyvinyl chloride, heat and moisture resistant, flame retardant compound, Stranded, uncoated bare copper per ASTM-B3, ASTM-B8 and ASTM-B787, A tough, polyamide, nylon outer covering per UL-83 and UL-1063 Encore Wire Corp 739373079350
Country of Origin: USA, Mfg Standards/Approvals: ARRA, Buy American Act, Reach, RoHS Compliant, UL File E-123774, E-156878, E-156879, cUL Listed, Type: Type THHN, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 1, Conductor Type: Solid Copper, Conductor Size: 12 AWG, Outside Diameter: 0.128 in, Length: 1000 ft, Strands: 19, Insulation Material: PVC, Jacket Material: Nylon, Jacket Color: Blue, Temperature Rating: 90 deg C Color code polyvinyl chloride, heat and moisture resistant, flame retardant compound, Stranded, uncoated bare copper per ASTM-B3, ASTM-B8 and ASTM-B787, A tough, polyamide, nylon outer covering per UL-83 and UL-1063 Encore Wire Corp 739373948250
Country of Origin: USA, Package Length: 5, Package Height: 8, Package Width: 12, Package Weight: 60, Mfg Standards/Approvals: ARRA, Buy American Act, Reach, RoHS Compliant, UL File E-123774, E-156878, E-156879, cUL Listed, Type: Type THHN, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 1, Conductor Type: Solid Copper, Conductor Size: 12 AWG, Outside Diameter: 0.128 in, Length: 2500 ft Reel, Strands: 19, Insulation Material: PVC, Jacket Material: Nylon, Jacket Color: Blue, Temperature Rating: 90 deg C Color code polyvinyl chloride, heat and moisture resistant, flame retardant compound, Stranded, uncoated bare copper per ASTM-B3, ASTM-B8 and ASTM-B787, A tough, polyamide, nylon outer covering per UL-83 and UL-1063 Encore Wire Corp 739373079459
Country of Origin: USA, Mfg Standards/Approvals: ARRA, Buy American Act, Reach, RoHS Compliant, UL File E-123774, E-156878, E-156879, cUL Listed, Type: Type THHN, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 1, Conductor Type: Solid Copper, Conductor Size: 12 AWG, Outside Diameter: 0.128 in, Length: 1000 ft, Strands: 19, Insulation Material: PVC, Jacket Material: Nylon, Jacket Color: Green, Temperature Rating: 90 deg C Color code polyvinyl chloride, heat and moisture resistant, flame retardant compound, Stranded, uncoated bare copper per ASTM-B3, ASTM-B8 and ASTM-B787, A tough, polyamide, nylon outer covering per UL-83 and UL-1063 Encore Wire Corp 739373948267
Country of Origin: USA, Package Length: 5, Package Height: 8, Package Width: 12, Package Weight: 60, Mfg Standards/Approvals: ARRA, Buy American Act, Reach, RoHS Compliant, UL File E-123774, E-156878, E-156879, cUL Listed, Type: Type THHN, Voltage Rating: 600 VAC, Amperage Rating: 30 A, Number of Conductors: 1, Conductor Type: Solid Copper, Conductor Size: 12 AWG, Outside Diameter: 0.128 in, Length: 2500 ft Reel, Strands: 19, Insulation Material: PVC, Jacket Material: Nylon, Jacket Color: Green, Temperature Rating: 90 deg C Color code polyvinyl chloride, heat and moisture resistant, flame retardant compound, Stranded, uncoated bare copper per ASTM-B3, ASTM-B8 and ASTM-B787, A tough, polyamide, nylon outer covering per UL-83 and UL-1063 Encore Wire Corp 739373079558