Wire Categories

Loading ...

Loading ...

Search in: Wire Category

Standard Packaging: 5000' Reel, Approximate Net Weight (lbs/1000 ft): 90, Number of Strands: 7, Allowable Ampacity (Amps) 60°C / 75°C / 90°C: - / 90 / 100, Size (AWG or KCMIL): 2, Approximate Overall Dimensions (in): 0.388, Compact Diameter of Aluminum Conductor (in): 0.268, XLPE Insulation Thickness (in): 0.060 Application:, Construction:, Conductors Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation Cross-linked polyethylene (XLPE) per UL-854. Sunlight-resistant in all colors 6 AWG and larger, Standards: Encore Wire Corp
P0723 THHN 600V.jpg 1/0 AWG, Stranded, Black THHN Wire, 500’ Reel
Locke Part #: P0780 MFG Part #: 118101801440
Color: Black, Outside Diameter: 0.474" (12.04 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 125, Allowable Ampacities (amps) @ 75°C: 150, Allowable Ampacities (amps) @ 90°C: 170, Size (AWG): 1/0, Approximate Net Weight: 372 lbs/1000ft (554 kg/km), Cross Sect Area (mm²): 53.50, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 546, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 100, Allowable Ampacities (amps) @ 75°C: 120, Allowable Ampacities (amps) @ 90°C: 135, Nominal Diameter (in): 1.150, Allowable Ampacities (amps) @ **Dwelling: 125, Ground/Neutral - Sizes (AWG): 2, Ground/Neutral - Style/Ground Neutral: 7, Insulated Phase Conductors - No of Strands: 10, Insulated Phase Conductors - Sizes (AWG): 1/0-1/0-1/0, Product Name (includes Ground): 1/0-1/0-1/0-2 Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 0 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836., Assembly:, Applications:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544., National Electric Code (NEC ) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
P0723 THHN 600V.jpg 1 AWG, Stranded, Black THHN Wire, 500’ Reel
Locke Part #: P0789 MFG Part #: 118101701440
Color: Black, Outside Diameter: 0.435" (11.05 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 110, Allowable Ampacities (amps) @ 75°C: 130, Allowable Ampacities (amps) @ 90°C: 150, Size (AWG): 1, Approximate Net Weight: 298 lbs/1000ft (445 kg/km), Cross Sect Area (mm²): 42.40, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 140, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Jacket Thickness (in): 0.030, Number of Strands: Solid, Outside Diameter (in): 0.230 x 0.460, Size (AWG) and Number of Conductors: 10/2G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 123, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.210 x 0.493, Size (AWG) and Number of Conductors: 10/2G, Carton Packaging: 100’, Master Packaging: 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 123, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.210 x 0.493, Size (AWG) and Number of Conductors: 10/2G, Standard Packaging (ft): 1000’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 123, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.210 x 0.493, Size (AWG) and Number of Conductors: 10/2G, Carton Packaging: 25’, Master Packaging: 250’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 123, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.210 x 0.493, Size (AWG) and Number of Conductors: 10/2G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 123, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.210 x 0.493, Size (AWG) and Number of Conductors: 10/2G, Carton Packaging: 50’, Master Packaging: 250’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 165, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.430, Size (AWG) and Number of Conductors: 10/3G, Carton Packaging: 100’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 165, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.430, Size (AWG) and Number of Conductors: 10/3G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 165, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.430, Size (AWG) and Number of Conductors: 10/3G, Carton Packaging: 50’, Master Packaging: 250’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 30, Approximate Net Weight (lbs/1000 ft): 165, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.020, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.430, Size (AWG) and Number of Conductors: 10/3G, Standard Packaging (ft): 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Color: Black, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 10 AWG, Solid, Blue Color THHN Wire, 500’ Reel
Locke Part #: P0739 MFG Part #: 105100904050
Color: Blue, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Brown, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Green, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Orange, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 10 AWG, Solid, Red Color THHN Wire, 500’ Reel
Locke Part #: P0758 MFG Part #: 105100903050
Color: Red, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: White, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Yellow, Type: THHN, Approximate Net Weight (lbs/1000 ft): 37, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm), Outside Dimensions (in): 0.160" (4.07 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Black, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Blue, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Brown, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Gray, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Green, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Orange, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Red, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: White, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Yellow, Type: THHN, Outside Diameter: 0.160" (4.07 mm), Approximate Net Weight (lbs/1000 ft): 38, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, Conductor Sizes (AWG): 10, PVC Insulation Thickness: 0.020" (0.510 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Blue-White, Approximate Net Weight (lbs/1000 ft): 106, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/2, Green Ground: 12 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.487 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards: Encore Wire Corp
Color: Red-White, Approximate Net Weight (lbs/1000 ft): 106, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/2, Green Ground: 12 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.487 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards: Encore Wire Corp
Allowable Ampacity (Amps): 16, Approximate Net Weight (lbs/1000 ft): 132, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.385, Size (AWG) and Number of Conductors: 12/2-2G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 75, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Jacket Thickness (in): 0.030, Number of Strands: Solid, Outside Diameter (in): 0.195 x 0.415, Size (AWG) and Number of Conductors: 12/2G, Carton Packaging: 100’, Master Packaging: 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 75, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Jacket Thickness (in): 0.030, Number of Strands: Solid, Outside Diameter (in): 0.195 x 0.415, Size (AWG) and Number of Conductors: 12/2G, Carton Packaging: 25’, Master Packaging: 250’ Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 75, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Jacket Thickness (in): 0.030, Number of Strands: Solid, Outside Diameter (in): 0.195 x 0.415, Size (AWG) and Number of Conductors: 12/2G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 82, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.160 x 0.450, Size (AWG) and Number of Conductors: 12/2G, Carton Packaging: 100’, Master Packaging: 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 82, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.160 x 0.450, Size (AWG) and Number of Conductors: 12/2G, Standard Packaging (ft): 1000’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 82, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.160 x 0.450, Size (AWG) and Number of Conductors: 12/2G, Carton Packaging: 25’, Master Packaging: 250’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 82, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.160 x 0.450, Size (AWG) and Number of Conductors: 12/2G, Carton Packaging: 50’, Master Packaging: 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 107, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.345, Size (AWG) and Number of Conductors: 12/3G, Carton Packaging: 100’, Master Packaging: 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 107, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.345, Size (AWG) and Number of Conductors: 12/3G, Standard Packaging (ft): 1000’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 107, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.345, Size (AWG) and Number of Conductors: 12/3G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 20, Approximate Net Weight (lbs/1000 ft): 107, Ground Wire Size (AWG): 12, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.345, Size (AWG) and Number of Conductors: 12/3G, Carton Packaging: 50’, Master Packaging: 250’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Color: Black, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Product Image Not Available 12 AWG, Solid, Blue Color THHN Wire, 500’ Reel
Locke Part #: P0775 MFG Part #: 105100804060
Color: Blue, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Color: Brown, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Product Image Not Available 12 AWG, Solid, Gray Color THHN Wire, 500’ Reel
Locke Part #: P0719 MFG Part #: 105100811060
Color: Gray, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Color: Green, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Color: Orange, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Color: Purple, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Product Image Not Available 12 AWG, Solid, Red Color THHN Wire, 500’ Reel
Locke Part #: P0779 MFG Part #: 105100803060
Color: Red, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Color: White, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Color: Yellow, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3., Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, ARRA 2009; Section 1605 "Buy American" Compliant, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers Encore Wire Corp
Color: Black, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Blue, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Brown, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Gray, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Green, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Orange, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Pink, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Purple, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Red, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Tan, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: White, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Yellow, Type: THHN, Outside Diameter: 0.127" (3.23 mm), Approximate Net Weight (lbs/1000 ft): 24, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, Conductor Sizes (AWG): 12, PVC Insulation Thickness: 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Pink, Standard Packaging: 2000’ carton (4 x 500’), 2500’ reels, Approximate Net Weight (lbs/1000 ft): 23, Number of Strands: 19, Outside Diameter (in): 0.127, Cross Sect Area (mm²): 3.31, Allowable Ampacity (Amps) 60°C / 75°C / 90°C: 20 / 25 / 30, Diameter of Bare Copper (in): 0.0880, Nylon Jacket Thickness (in): 0.004, PVC Insulation Thickness (Conductor) (in): 0.015, Size (AWG or KCMIL): 12 Applications:, C or not to exceed 75 C in oil or coolants. For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3 Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83, Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Allowable Ampacity (Amps): 15, Approximate Net Weight (lbs/1000 ft): 53, Ground Wire Size (AWG): 14, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Jacket Thickness (in): 0.030, Number of Strands: Solid, Outside Diameter (in): 0.185 x 0.385, Size (AWG) and Number of Conductors: 14/2G, Standard Packaging (ft): 1000’ Reel Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
Allowable Ampacity (Amps): 15, Approximate Net Weight (lbs/1000 ft): 53, Ground Wire Size (AWG): 14, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Jacket Thickness (in): 0.030, Number of Strands: Solid, Outside Diameter (in): 0.185 x 0.385, Size (AWG) and Number of Conductors: 14/2G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
Allowable Ampacity (Amps): 15, Approximate Net Weight (lbs/1000 ft): 56, Ground Wire Size (AWG): 14, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.170 x 0.390, Size (AWG) and Number of Conductors: 14/2G, Carton Packaging: 100’, Master Packaging: 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 15, Approximate Net Weight (lbs/1000 ft): 56, Ground Wire Size (AWG): 14, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.170 x 0.390, Size (AWG) and Number of Conductors: 14/2G, Carton Packaging: 25’, Master Packaging: 250’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 15, Approximate Net Weight (lbs/1000 ft): 56, Ground Wire Size (AWG): 14, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.170 x 0.390, Size (AWG) and Number of Conductors: 14/2G, Carton Packaging: 50’, Master Packaging: 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 15, Approximate Net Weight (lbs/1000 ft): 74, Ground Wire Size (AWG): 14, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.170 x 0.450, Size (AWG) and Number of Conductors: 14/3G, Carton Packaging: 100’, Master Packaging: 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 15, Approximate Net Weight (lbs/1000 ft): 74, Ground Wire Size (AWG): 14, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.170 x 0.450, Size (AWG) and Number of Conductors: 14/3G, Standard Packaging (ft): 1000’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 15, Approximate Net Weight (lbs/1000 ft): 74, Ground Wire Size (AWG): 14, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.170 x 0.450, Size (AWG) and Number of Conductors: 14/3G, Standard Packaging (ft): 250’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 15, Approximate Net Weight (lbs/1000 ft): 74, Ground Wire Size (AWG): 14, Insulation Thickness (in): PVC: 0.015, Nylon: 0.004, Number of Strands: Solid, Outside Diameter (in): 0.170 x 0.450, Size (AWG) and Number of Conductors: 14/3G, Carton Packaging: 50’, Master Packaging: 250’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Color: Black, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 14 AWG, Solid, Blue Color THHN Wire, 500’ Roll
Locke Part #: P1646 MFG Part #: 105100704060
Color: Blue, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Brown, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 14 AWG, Solid, Gray Color THHN Wire, 500’ Roll
Locke Part #: P1648 MFG Part #: 105100711060
Color: Gray, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Green, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Product Image Not Available 14 AWG, Solid, Red Color THHN Wire, 500’ Roll
Locke Part #: P1754 MFG Part #: 105100703060
Color: Red, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: White, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Yellow, Type: THHN, Approximate Net Weight (lbs/1000 ft): 15, Number of Strands: Solid, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Black, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Blue, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Brown, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Gray, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Green, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Orange, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Purple, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Red, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: White, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Yellow, Type: THHN, Approximate Net Weight (lbs/1000 ft): 16, Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 15, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, Conductor Sizes (AWG): 14, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.109" (2.77 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG,, All sizes rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC), Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants,, Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
SOOW-14-3.jpg 14 ga SOOW Portable Power Cable - 90°C 600V, 3 Conductors
Locke Part #: P0678 MFG Part #: 14/3 SOOW-A CORD 250' R
Conductor Strand: 41/30, Size AWG: 14, No of Conductors: 3, Nominal Insulation Thickness (inches): 0.045, Nominal Insulation Thickness (mm): 1.14, Nominal Overall Diameter (inches): 0.530, Nominal Overall Diameter (mm): 13.46, Current Amps**: 18, Weight lbs/M: 176 For use with portable tools, equipment, appliances, small motors and associated machinery where flexibility and durability are required, Has a stranded soft drawn bare copper conductor per ASTM B3 and B174., Has premium grade color coded ethylene propylene diene monomer EPDM insulation., It has an overall jacket of black chlorinated polyethylene CPE, which is oil, moisture and abrasion resistant., Standards:, UL flexible cord Subject 62, CSA flexible cord C22.2-49, OSHA accepted , MSHA approved, Federal Specification JC 580 PRIORITY WIRE & CABLE INC
Color: Black, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 2000’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Blue, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Brown, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Gray, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Green, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Orange, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Purple, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Red, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: White, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Yellow, Type: TFFN, Approximate Net Weight (lbs/1000 ft): 11, Number of Strands: 26, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 8, Allowable Ampacities (amps) @ 75°C: 8, Allowable Ampacities (amps) @ 90°C: 8, Conductor Sizes (AWG): 16, PVC Insulation Thickness: 0.015" (0.380 mm), Outside Dimensions (in): 0.101" (2.57 mm) Slick, Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG., All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., Applications requiring Type THHN or THWN-2: the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., Applications requiring Type MTW: the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM: the conductor is appropriate for use at temperatures to not exceed 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658,, Institute of Electrical and Electronics Engineers,, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Yellow, Type: TFN, Outside Diameter: 0.0783" (1.99 mm), Allowable Ampacity (Amps): 6, Size Ground/Neutral Conductor (AWG): 18, Number of Strands: Solid, Standard Packaging (ft): 500’, Approximate Net Weight: 8 lbs/1000 Ft (12 kg/km), Nylon Jacket Thickness: 0.004" (0.100 mm), PVC Insulation Thickness (Conductor): 0.015" (0.380 mm) Slick, Nylon outer jacket for easy pulling. All sizes are rated gasoline and oil-resistant II., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B174, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound, Applications:, Type TFFN (stranded) or TFN (solid) conductors are primarily used as fixture wire as defined by the National Electrical, Code (NEC) at temperatures not to exceed 90 C in dry locations., For applications requiring Type MTW, the conductor is permitted for use in dry locations at 90 C or not to exceed 60 C in wet locations or where exposed to oils or coolants., For applications requiring Type AWM, conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., All conductors are permitted for new construction or rewiring for 600-volt applications., Jacket:, A tough, polyamide, Nylon outer covering, Standards:, Underwriters Laboratories Standards, UL-62, UL-66, UL-758 and UL-1063, AWM Spec 1310, 1312, 1316, 1318, 1321, ASTM Stranding Class B3, B8, B787, Canadian Standard Association C22.2 No. 127, NFPA 70: National Electrical Code (NEC) ARRA 2009, Section 1605 "Buy American" Compliant Encore Wire Corp
P0723 THHN 600V.jpg 2/0 AWG, Stranded, Black THHN Wire, 500’ Reel
Locke Part #: P0781 MFG Part #: 118101901440
Color: Black, Outside Diameter: 0.518" (13.16 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 145, Allowable Ampacities (amps) @ 75°C: 175, Allowable Ampacities (amps) @ 90°C: 195, Size (AWG): 2/0, Approximate Net Weight: 462 lbs/1000ft (687 kg/km), Cross Sect Area (mm²): 67.40, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 652, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 115, Allowable Ampacities (amps) @ 75°C: 135, Allowable Ampacities (amps) @ 90°C: 150, Nominal Diameter (in): 1.250, Allowable Ampacities (amps) @ **Dwelling: 150, Ground/Neutral - Sizes (AWG): 1, Ground/Neutral - Style/Ground Neutral: 8, Insulated Phase Conductors - No of Strands: 12, Insulated Phase Conductors - Sizes (AWG): 2/0-2/0-2/0, Product Name (includes Ground): 2/0-2/0-2/0-1 Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 0 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836., Assembly:, Applications:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544., National Electric Code (NEC ) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): (1)195, (2)200, Approximate Net Weight (lbs/1000 ft): 1431, Ground/Neutral Conductor Stranding (No of Wires): 18, Insulated Conductor Size (AWG): 2/0-2/0-2/0, Insulated Conductor Stranding (No of Wires): 19, Nominal Dimensions (in): 0.810 x 1.350, Package NR Reels (ft): 500’, Size Ground/Neutral Conductor (AWG): 2/0 Construction:, Conductors:, Solid: Bare, soft copper per ASTM-B3, 7-strand: Class B concentrically stranded per ASTM-B8, 19-strand: Combination unilay conductors per ASTM-B787, Insulation:, High dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC) rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN or THWN wire., Conductor Jacket, :, Clear Nylon sheath meeting the requirements of UL-83 for THHN or THWN., Ground/Neutral Conductor, :, Soft drawn annealed copper conductors., Sizes smaller than 3 AWG have a round, stranded bare ground/neutral conductor laid parallel between the insulated conductors., Sizes 3 AWG and larger have bare concentric ground/neutral wires wrapped helically over the insulated conductors., Applications:, This cable is manufactured in accordance with Article 338 of the NEC and also the requirements of Underwriters Laboratories Standard 854., Type SE Style U is approved for installation in accordance with Article 230 of the NEC and has a rating of 600 volts., Assembly, :, Overall Jacket, :, Extruded, protective sunlight-resistant gray PVC jacket over the taped assembly in accordance with UL Standard 854., Standards:, Underwriters Laboratories Standards UL-83, UL-854, Federal Specification AA59544, National Electrical Code Articles 338 & 230, NEMA RV4 2009, ARRA 2009; Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): (1)195, (2)200, Approximate Net Weight (lbs/1000 ft): 1768, Insulated Conductor Size (AWG): 2/0-2/0-2/0-1, Insulated Conductor Stranding (No of Wires): 19, Standard Packaging (ft): 500’, Outside Dimensions (in): 1.310, Bare Grounding/Neutral Conductor Size (AWG) Stranding: 1 Conductors:, 7-strand: Class B concentrically stranded per ASTM-B8, 19-strand: Combination unilay stranded conductors per ASTM-B787, Insulation:, High dielectric strength, heat- and moisture-resistant, black or colored Polyvinyl Chloride (PVC) rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN or THWN wire., Conductor jacket:, Clear Nylon sheath meeting the requirements of UL-83 for THHN or THWN ground/neutral conductor:, Bare, soft-drawn grounding conductor per ASTM-B3, ASTM-B8, or ASTM-B787, Applications:, Assembly:, Conductors are twisted together with the bare, copper grounding conductor in one interstice. A glass-reinforced tape is applied over the cabled core., Overall Jacket:, Extruded, protective gray sunlight-resistant PVC jacket over the taped assembly in accordance with UL Standard 854., Standards:, Underwriters Laboratories Standards UL-83, UL-854., Federal Specifications AA59544., National Electrical Code Articles 338 & 230., NEMA RV4 2009., ARRA 2009; Section 1605 Buy American Compliant. Encore Wire Corp
P0686.jpg 2 AWG, Solid, Bare Copper Wire, 500’ Reel
Locke Part #: P6373 MFG Part #: 170101600140
Outside Diameter: 0.2576" (6.54 mm), Approximate Net Weight (lbs/1000 ft): 212.8, Number of Strands: Solid, Standard Packaging (ft): 500’, Area (cmils): 66,360, Size (AWG): 2, Soft-Drawn (Annealed) - DC Resistance (Ohms/1000 ft @ 20°C): 0.1594, Soft-Drawn (Annealed) - Rated Strength (lbs): 1,930 Highest conductivity per unit area of all common commercial metals., Excellent corrosion resistance., Flexible; easily worked and formed into place., Packaged on non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installations., Good fatigue-resistance; not subject to breaks due to nicks or cuts when terminating., Totally recyclable with high scrap value., Contact your local representative for information on the Encore Wire Scrap Purchase Program., Construction:, Soft-Drawn Solid or Stranded, Annealed Bare Copper., Applications:, Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding., Standards:, ASTM-B3 for soft-drawn solid copper wire., ASTM-B8 for soft-drawn concentric lay stranded copper wire., ASTM-B787 for 19-wire combination unilay stranded wire., ARRA 2009; Section 1605 "Buy American" Compliant. Encore Wire Corp
P0723 THHN 600V.jpg 2 AWG, Stranded, Black THHN Wire, 500’ Reel
Locke Part #: P0773 MFG Part #: 118101601440
Color: Black, Outside Diameter: 0.375" (9.53 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 95, Allowable Ampacities (amps) @ 75°C: 115, Allowable Ampacities (amps) @ 90°C: 130, Size (AWG): 2, Approximate Net Weight: 233 lbs/1000ft (348 kg/km), Cross Sect Area (mm²): 33.60, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Black, Approximate Net Weight (lbs/1000 ft): 90, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 75°C: 90, Allowable Ampacities (amps) @ 90°C: 100, Size (AWG or KCMIL): 2, Approximate Overall Dimensions (in): 0.388, Compact Diameter of Aluminum Conductor (in): 0.268, No of Strands: 7, XLPE Insulation Thickness (in): 0.060 Insulation compound carries VW-1 (vertical wire flame) rating and FT2 (horizontal flame) rating and is sunlight-resistant (6 AWG and larger) in all colors., 1/0 AWG and larger are rated for CT use and comply with IEEE 1202/FT4 Flame Test., When used as RHH or RHW-2, cable complies with ICEA T-29-520 (210,000 Btu/hr) Flame Test., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, Insulation:, Cross-linked polyethylene (XLPE) per UL-854. Sunlight-resistant in all colors 6 AWG and larger, Applications:, Type USE-2, RHH or RHW-2 cables with Aluminum Alloy 8000 Series conductors are suitable for use in conduit and raceways installed underground in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90 C., Permitted for Type USE-2 per UL-854 for applications requiring direct burial., For applications requiring Type RHH or RHW-2, conductor temperatures shall not exceed 90 C in wet or dry locations., Type USE-2, RHH, or RHW-2 is permitted for 600 volt applications., Standards:, Underwriters Laboratories Standards UL-44; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836;, Federal Specification AA-59544; NEMA WC70 / ICEA S-95-658; NEMA RV4 2012; NFPA 70., National Electrical Code (NEC ). ARRA 2009 Section 1605 Buy American Compliant., IEEE 1202/FT4 Flame Test; ICEA T-29-520 (210,000 Btu/hr) Flame Test. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 294, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 75, Allowable Ampacities (amps) @ 75°C: 90, Allowable Ampacities (amps) @ 90°C: 100, Approximate Overall Dimensions (in): 0.597 x 0.957, Allowable Ampacities (amps) @ **Dwelling: 100, Ground/Neutral - Sizes (AWG): 2, Ground/Neutral - Style/Ground Neutral: Helical, Insulated Phase Conductors - No of Strands: 7, Insulated Phase Conductors - Sizes (AWG): 2-2, Conductor Sizes (includes Ground)(AWG or KCMIL): 2-2-2 Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836. The ground/neutral is evenly distributed and helically applied over the insulated conductors to produce the equivalent size required by UL-854., Application:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544; National Electrical Code (NEC) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 364, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 75, Allowable Ampacities (amps) @ 75°C: 90, Allowable Ampacities (amps) @ 90°C: 100, Nominal Diameter (in): 0.950, Allowable Ampacities (amps) @ **Dwelling: 100, Ground/Neutral - Sizes (AWG): 4, Ground/Neutral - Style/Ground Neutral: 7, Insulated Phase Conductors - No of Strands: 7, Insulated Phase Conductors - Sizes (AWG): 2-2-2, Product Name (includes Ground): 2-2-2-4 Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, High-dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC), rated for continuous use at 0 C wet or dry, meeting the requirements of UL-83 for THHN/THWN-2., Conductor Jacket:, A tough, polyamide nylon outer covering per UL-83., Grounding/Neutral Conductor:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800, B801, and B836., Assembly:, Applications:, Standards:, Underwriters Laboratories Standards UL-83; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Federal Specifications AA-59544., National Electric Code (NEC ) Articles 338 & 230; NEMA RV4 2012., ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 332, Standard Packaging (ft): 1000’, Conductor Sizes (AWG): 2-2-2-4, Allowable Ampacities for Direct Burial: 153, Code Name: Dyke, Finished Cable - Outside Diameter (in): 0.937, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.330, Neutral Conductor - Size (AWG): 4, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.388, Phase Conductors - Size (AWG): 2, Phase Conductors - XLPE Thickness (in): 0.060 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
P6482.jpg 2-2-2-4 AWG, Type SE - Style R Wire, 500’ Reel
Locke Part #: P6482 MFG Part #: 104151611240
Allowable Ampacity (Amps): (1)130, (2)125, Approximate Net Weight (lbs/1000 ft): 911, Insulated Conductor Size (AWG): 2-2-2-4, Insulated Conductor Stranding (No of Wires): 7, Standard Packaging (ft): 500’, Outside Dimensions (in): 0.970, Bare Grounding/Neutral Conductor Size (AWG) Stranding: 4 Conductors:, 7-strand: Class B concentrically stranded per ASTM-B8, 19-strand: Combination unilay stranded conductors per ASTM-B787, Insulation:, High dielectric strength, heat- and moisture-resistant, black or colored Polyvinyl Chloride (PVC) rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN or THWN wire., Conductor jacket:, Clear Nylon sheath meeting the requirements of UL-83 for THHN or THWN ground/neutral conductor:, Bare, soft-drawn grounding conductor per ASTM-B3, ASTM-B8, or ASTM-B787, Applications:, Assembly:, Conductors are twisted together with the bare, copper grounding conductor in one interstice. A glass-reinforced tape is applied over the cabled core., Overall Jacket:, Extruded, protective gray sunlight-resistant PVC jacket over the taped assembly in accordance with UL Standard 854., Standards:, Underwriters Laboratories Standards UL-83, UL-854., Federal Specifications AA59544., National Electrical Code Articles 338 & 230., NEMA RV4 2009., ARRA 2009; Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 241, Standard Packaging (ft): 500’, Conductor Sizes (AWG): 2-2-4, Allowable Ampacities for Direct Burial: 168, Code Name: Stephens, Finished Cable - Outside Diameter (in): 0.869, Neutral Conductor - No of Strands: 7, Neutral Conductor - Outside Diameter (in): 0.333, Neutral Conductor - Size (AWG): 4, Neutral Conductor - XLPE Thickness (in): 0.060, Phase Conductors - No of Strands: 7, Phase Conductors - Outside Diameter (in): 0.388, Phase Conductors - Size (AWG): 2, Phase Conductors - XLPE Thickness (in): 0.060 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
P0723 THHN 600V.jpg 3/0 AWG, Stranded, Black THHN Wire, 500’ Reel
Locke Part #: P0782 MFG Part #: 118102001440
Color: Black, Outside Diameter: 0.568" (14.43 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 165, Allowable Ampacities (amps) @ 75°C: 200, Allowable Ampacities (amps) @ 90°C: 225, Size (AWG): 3/0, Approximate Net Weight: 572 lbs/1000ft (851 kg/km), Cross Sect Area (mm²): 85.00, Nylon Jacket Thickness: 0.007" (0.180 mm), PVC Insulation Thickness (Conductor): 0.050" (1.270 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
P0723 THHN 600V.jpg 3 AWG, Stranded, Black THHN Wire, 500’ Reel
Locke Part #: P0772 MFG Part #: 118101501440
Color: Black, Outside Diameter: 0.344" (8.74 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 85, Allowable Ampacities (amps) @ 75°C: 100, Allowable Ampacities (amps) @ 90°C: 110, Size (AWG): 3, Approximate Net Weight: 189 lbs/1000ft (281 kg/km), Cross Sect Area (mm²): 26.70, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 4-4-4, Standard Packaging (ft): 500’, Conductor Sizes (AWG): 4/0-4/0-2/0, Allowable Ampacities for Direct Burial: 322, Code Name: Sweetbriar, Finished Cable - Outside Diameter (in): 1.420, Neutral Conductor - No of Strands: 12, Neutral Conductor - Outside Diameter (in): 0.536, Neutral Conductor - Size (AWG): 2/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 19, Phase Conductors - Outside Diameter (in): 0.635, Phase Conductors - Size (AWG): 4/0, Phase Conductors - XLPE Thickness (in): 0.080 One black triple-rated USE-2/RHH/RHW-2 phase conductor cabled together with one yellow triple-rated USE-2/RHH/RHW-2 neutral conductor, Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600 Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables, Conductors are surface printed for identification., Also manufactured and tested according to UL-854, and UL-44 for triple-rated USE-2/RHH/RHW-2 cables., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL-854, UL-44, and ANSI/ICEA S-105-692. Black XLPE insulation on phase conductors, yellow XLPE insulation on neutral., Applications:, Triple-rated conductors can also be installed on both sides of the service point and when the service point is located inside building envelope, For applications not exceeding 600 volts., May be used for NEC applications, as well as, non-NEC applications including direct burial, or for installation in ducts or conduits, All conductors are UL triple-rated as USE-2 per UL-854, and RHH/RHW-2 per UL-44., Standards, Underwriters Laboratories Standards UL-854; ANSI/ICEA S-105-692; IEEE 835-1994, Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 200, Standard Packaging (ft): 500’, Conductor Sizes (AWG): 4/0-4/0-2/0-4, Finished Cable - Outside Diameter (in): 1.550, Neutral Conductor - No of Strands: 12, Neutral Conductor - Outside Diameter (in): 0.550, Neutral Conductor - Size (AWG): 2/0, Neutral Conductor - XLPE Thickness (in): 0.080, Phase Conductors - No of Strands: 19, Phase Conductors - Outside Diameter (in): 0.648, Phase Conductors - Size (AWG): 4/0, Phase Conductors - XLPE Thickness (in): 0.080, Ground Cable - No of Strands: 6, Ground Cable - Outside Diameter (in): 0.340, Ground Cable - Size (AWG): 4, Ground Cable - XLPE Thickness: 0.060 Two black triple-rated USE-2/RHH/RHW-2 phase conductors cabled together with one white triple-rated USE-2/RHH/RHW-2 neutral conductor and one green insulated ground wire., All cables employ ASTM 8000 Series aluminum alloy conductors., Superior weather, abrasion, crush, and sunlight-resistant XLPE insulation., Manufactured and tested according to ANSI/ICEA S-105-692: Standard for 600-Volt Single Layer Thermoset Insulated Utility Underground Distribution Cables., Also manufactured and tested according to UL-854, and UL-44., Conductors are surface printed for identification., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836., Insulation:, Cross-link polyethylene (XLPE) insulation per UL 854, UL 44, and ANSI/ICEA S-105-692., Black XLPE insulation on phase conductors, white XLPE on neutral conductor, green XLPE on ground., Applications:, Quadruplex type USE-2/RHH/RHW-2 with Compact Stranded Aluminum Alloy 8000 Series conductors per ASTM B800; ASTM B801; ASTM B836., Suitable for electrical connections in mobile homes for permanent wiring according to the 2008 NEC., Suitable for wet and dry locations in conduit where temperatures do not exceed 90 C., Direct Burial in earth permitted for Type USE-2, RHH, and RHW-2 per UL854 where temperatures do not exceed 90 C. 600 volt rated. XLPE insulation is sunlight-resistant for 6 AWG and larger., 1/0 AWG and larger complies with IEEE 1202/UL FT-4 flame test., 1/0 AWG and larger also complies with ICEA T-29-520 (210,000 btu/hr) flame test., Standards:, Underwriters Laboratories Standards UL-854; UL-44; ANSI/ICEA S-105-692; IEEE 835-1994; Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836; ARRA 2009 Section 1605 Buy American Compliant. Encore Wire Corp
Size: 8 AWG, Packaging (ft): 1000’ reels, Approximate Net Weight (lbs/1000 ft) - 3: 282, Approximate Net Weight (lbs/1000 ft) - 4: 351, Number Of Conductors: 4/3, Outer Jacket Thickness PVC (in) - 3: .060, Outer Jacket Thickness PVC (in) - 4: .060, Outside Diameter (in) - 3: .610, Outside Diameter (in) - 4: .655 Encore Wire Corp
Allowable Ampacity (Amps): 70, Approximate Net Weight (lbs/1000 ft): 565, Ground Wire Size (AWG): 8, Insulation Thickness (in): PVC: 0.040, Nylon: 0.006, Number of Strands: 7, Outside Diameter (in): 0.820, Size (AWG) and Number of Conductors: 4/3G, Standard Packaging (ft): 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
P0686.jpg 4 AWG, Solid, Bare Copper Wire, 200’ Reel
Locke Part #: P0771 MFG Part #: 170101400125
Outside Diameter: 0.2043" (5.19 mm), Approximate Net Weight (lbs/1000 ft): 126.4, Number of Strands: Solid, Standard Packaging (ft): 200’, Area (cmils): 41,740, Size (AWG): 4, Soft-Drawn (Annealed) - DC Resistance (Ohms/1000 ft @ 20°C): 0.2535, Soft-Drawn (Annealed) - Rated Strength (lbs): 1,214 Highest conductivity per unit area of all common commercial metals., Excellent corrosion resistance., Flexible; easily worked and formed into place., Packaged on non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installations., Good fatigue-resistance; not subject to breaks due to nicks or cuts when terminating., Totally recyclable with high scrap value., Contact your local representative for information on the Encore Wire Scrap Purchase Program., Construction:, Soft-Drawn Solid or Stranded, Annealed Bare Copper., Applications:, Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding., Standards:, ASTM-B3 for soft-drawn solid copper wire., ASTM-B8 for soft-drawn concentric lay stranded copper wire., ASTM-B787 for 19-wire combination unilay stranded wire., ARRA 2009; Section 1605 "Buy American" Compliant. Encore Wire Corp
P0723 THHN 600V.jpg 4 AWG, Stranded, Black THHN Wire, 500’ Reel
Locke Part #: P0749 MFG Part #: 118101401440
Color: Black, Outside Diameter: 0.317" (8.06 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 70, Allowable Ampacities (amps) @ 75°C: 85, Allowable Ampacities (amps) @ 90°C: 95, Size (AWG): 4, Approximate Net Weight: 153 lbs/1000ft (228 kg/km), Cross Sect Area (mm²): 21.20, Nylon Jacket Thickness: 0.006" (0.150 mm), PVC Insulation Thickness (Conductor): 0.040" (1.020 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Black, Approximate Net Weight (lbs/1000 ft): 62, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 75°C: 65, Allowable Ampacities (amps) @ 90°C: 75, Size (AWG or KCMIL): 4, Approximate Overall Dimensions (in): 0.333, Compact Diameter of Aluminum Conductor (in): 0.213, No of Strands: 7, XLPE Insulation Thickness (in): 0.060 Insulation compound carries VW-1 (vertical wire flame) rating and FT2 (horizontal flame) rating and is sunlight-resistant (6 AWG and larger) in all colors., 1/0 AWG and larger are rated for CT use and comply with IEEE 1202/FT4 Flame Test., When used as RHH or RHW-2, cable complies with ICEA T-29-520 (210,000 Btu/hr) Flame Test., Construction:, Conductors:, Compact Stranded Conductors, Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836, Insulation:, Cross-linked polyethylene (XLPE) per UL-854. Sunlight-resistant in all colors 6 AWG and larger, Applications:, Type USE-2, RHH or RHW-2 cables with Aluminum Alloy 8000 Series conductors are suitable for use in conduit and raceways installed underground in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90 C., Permitted for Type USE-2 per UL-854 for applications requiring direct burial., For applications requiring Type RHH or RHW-2, conductor temperatures shall not exceed 90 C in wet or dry locations., Type USE-2, RHH, or RHW-2 is permitted for 600 volt applications., Standards:, Underwriters Laboratories Standards UL-44; UL-854., Compact Stranded Aluminum Alloy 8000 Series per ASTM B800; ASTM B801; ASTM B836;, Federal Specification AA-59544; NEMA WC70 / ICEA S-95-658; NEMA RV4 2012; NFPA 70., National Electrical Code (NEC ). ARRA 2009 Section 1605 Buy American Compliant., IEEE 1202/FT4 Flame Test; ICEA T-29-520 (210,000 Btu/hr) Flame Test. Encore Wire Corp
P0634.jpg 4-4-4 AWG, Type SE Style U Wire, 500’ Reel
Locke Part #: P0682 MFG Part #: 103141411240
Allowable Ampacity (Amps): (1)95, (2)100, Approximate Net Weight (lbs/1000 ft): 494, Ground/Neutral Conductor Stranding (No of Wires): 7, Insulated Conductor Size (AWG): 4-4-4, Insulated Conductor Stranding (No of Wires): 7, Nominal Dimensions (in): 0.540 x 0.870, Package NR Reels (ft): 500’, Size Ground/Neutral Conductor (AWG): 4, Standard Coils (ft): 150’ Construction:, Conductors:, Solid: Bare, soft copper per ASTM-B3, 7-strand: Class B concentrically stranded per ASTM-B8, 19-strand: Combination unilay conductors per ASTM-B787, Insulation:, High dielectric strength, heat and moisture-resistant, black or colored Polyvinyl Chloride (PVC) rated for continuous use at 90 C wet or dry, meeting the requirements of UL-83 for THHN or THWN wire., Conductor Jacket, :, Clear Nylon sheath meeting the requirements of UL-83 for THHN or THWN., Ground/Neutral Conductor, :, Soft drawn annealed copper conductors., Sizes smaller than 3 AWG have a round, stranded bare ground/neutral conductor laid parallel between the insulated conductors., Sizes 3 AWG and larger have bare concentric ground/neutral wires wrapped helically over the insulated conductors., Applications:, This cable is manufactured in accordance with Article 338 of the NEC and also the requirements of Underwriters Laboratories Standard 854., Type SE Style U is approved for installation in accordance with Article 230 of the NEC and has a rating of 600 volts., Assembly, :, Overall Jacket, :, Extruded, protective sunlight-resistant gray PVC jacket over the taped assembly in accordance with UL Standard 854., Standards:, Underwriters Laboratories Standards UL-83, UL-854, Federal Specification AA59544, National Electrical Code Articles 338 & 230, NEMA RV4 2009, ARRA 2009; Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 55, Approximate Net Weight (lbs/1000 ft): 256, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.330 x 0.695, Size (AWG) and Number of Conductors: 6/2G, Standard Packaging (ft): 125’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 55, Approximate Net Weight (lbs/1000 ft): 256, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.330 x 0.695, Size (AWG) and Number of Conductors: 6/2G, Standard Packaging (ft): 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 0, Outside Diameter Over Armor (in): 0.884, Conductor - AWG No: 6/3, Conductor - Green Ground: 8 AWG, Conductor - Type: Stranded, Packaging (ft): 500’ reels, Allowable Ampacity (Amps) - 75°C: 65, Jacket Thickness: 0.050, Outside Diameter Over Jacket (in): 1.045 Encore Wire Corp
Allowable Ampacity (Amps): 55, Approximate Net Weight (lbs/1000 ft): 352, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.612, Size (AWG) and Number of Conductors: 6/3G, Standard Packaging (ft): 125’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 55, Approximate Net Weight (lbs/1000 ft): 352, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.612, Size (AWG) and Number of Conductors: 6/3G, Standard Packaging (ft): 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
P0686.jpg 6 AWG, Solid, Bare Copper Wire, 315’ Reel
Locke Part #: P0770 MFG Part #: 170101200035
Outside Diameter: 0.1620" (4.12 mm), Approximate Net Weight (lbs/1000 ft): 79.5, Number of Strands: Solid, Standard Packaging (ft): 315’, Area (cmils): 26,240, Size (AWG): 6, Soft-Drawn (Annealed) - DC Resistance (Ohms/1000 ft @ 20°C): 0.4031, Soft-Drawn (Annealed) - Rated Strength (lbs): 762 Highest conductivity per unit area of all common commercial metals., Excellent corrosion resistance., Flexible; easily worked and formed into place., Packaged on non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installations., Good fatigue-resistance; not subject to breaks due to nicks or cuts when terminating., Totally recyclable with high scrap value., Contact your local representative for information on the Encore Wire Scrap Purchase Program., Construction:, Soft-Drawn Solid or Stranded, Annealed Bare Copper., Applications:, Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding., Standards:, ASTM-B3 for soft-drawn solid copper wire., ASTM-B8 for soft-drawn concentric lay stranded copper wire., ASTM-B787 for 19-wire combination unilay stranded wire., ARRA 2009; Section 1605 "Buy American" Compliant. Encore Wire Corp
Color: Black, Outside Diameter: 0.248" (6.30 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 55, Allowable Ampacities (amps) @ 75°C: 65, Allowable Ampacities (amps) @ 90°C: 75, Size (AWG): 6, Approximate Net Weight: 94 lbs/1000 Ft (141 kg/km), Cross Sect Area (mm²): 13.30, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Green, Outside Diameter: 0.248" (6.30 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 55, Allowable Ampacities (amps) @ 75°C: 65, Allowable Ampacities (amps) @ 90°C: 75, Size (AWG): 6, Approximate Net Weight: 94 lbs/1000 Ft (141 kg/km), Cross Sect Area (mm²): 13.30, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Red, Outside Diameter: 0.248" (6.30 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 55, Allowable Ampacities (amps) @ 75°C: 65, Allowable Ampacities (amps) @ 90°C: 75, Size (AWG): 6, Approximate Net Weight: 94 lbs/1000 Ft (141 kg/km), Cross Sect Area (mm²): 13.30, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: White, Outside Diameter: 0.248" (6.30 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 55, Allowable Ampacities (amps) @ 75°C: 65, Allowable Ampacities (amps) @ 90°C: 75, Size (AWG): 6, Approximate Net Weight: 94 lbs/1000 Ft (141 kg/km), Cross Sect Area (mm²): 13.30, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Allowable Ampacity (Amps): 40, Approximate Net Weight (lbs/1000 ft): 213, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Jacket Thickness (in): 0.045, Number of Strands: 7, Outside Diameter (in): 0.320 x 0.620, Size (AWG) and Number of Conductors: 8/2G, Standard Packaging (ft): 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
Allowable Ampacity (Amps): 40, Approximate Net Weight (lbs/1000 ft): 185, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.290 x 0.580, Size (AWG) and Number of Conductors: 8/2G, Standard Packaging (ft): 125’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 40, Approximate Net Weight (lbs/1000 ft): 185, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.290 x 0.580, Size (AWG) and Number of Conductors: 8/2G, Standard Packaging (ft): 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Approximate Net Weight (lbs/1000 ft): 524, Outside Diameter Over Armor (in): 0.757, Conductor - AWG No: 8/3, Conductor - Green Ground: 10 AWG, Conductor - Type: Stranded, Packaging (ft): 500’ reels, Allowable Ampacity (Amps) - 75°C: 50, Jacket Thickness: 0.050, Outside Diameter Over Jacket (in): 0.957 Encore Wire Corp
Allowable Ampacity (Amps): 40, Approximate Net Weight (lbs/1000 ft): 330, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Jacket Thickness (in): 0.045, Number of Strands: 7, Outside Diameter (in): 0.320 x 0.990, Size (AWG) and Number of Conductors: 8/3G, Standard Packaging (ft): 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper per ASTM-B3., Stranded 8 AWG conductor and larger uncoated per ASTM-B8., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN or THWN with a heat-stabilized Nylon rated for 90 C in dry or 75 C in wet locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and or B8., Applications:, Maximum voltage rating for UF-B is 600 volts., Type UF-B may be installed as interior wiring in wet, dry, or corrosive locations at temperatures not to exceed 90 C (with ampacity limited to that for 60 C conductors) as specified by the National Electrical Code., Type UF-B may be used where exposed to direct rays of the sun or underground, including direct burial., Assembly:, 2 and 3-conductor constructions have the insulated conductors laid parallel. When a ground wire is present, it is laid in a valley between the insulated conductors., Jacket:, A gray, sunlight-resistant PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83, UL-493, Federal Specification A-A-59544, ASTM-B3 and B8, ARRA 2009; Section 1605 Buy American Compliant Encore Wire Corp
Allowable Ampacity (Amps): 40, Approximate Net Weight (lbs/1000 ft): 251, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.555, Size (AWG) and Number of Conductors: 8/3G, Standard Packaging (ft): 125’ EZ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
Allowable Ampacity (Amps): 40, Approximate Net Weight (lbs/1000 ft): 251, Ground Wire Size (AWG): 10, Insulation Thickness (in): PVC: 0.030, Nylon: 0.005, Number of Strands: 7, Outside Diameter (in): 0.555, Size (AWG) and Number of Conductors: 8/3G, Standard Packaging (ft): 500’ Conductors:, Solid 14-10 AWG soft, uncoated copper, per ASTM-B3., Insulation:, Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90 C in dry locations., Grounding Conductor:, Soft, uncoated copper per ASTM-B3 and/or ASTM-B8., Applications, :, Type, NM, -B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC)., Type, NM, -B cable is commonly used for residential fixtures, switches, and loads rated for at least 90 C., Type NM-B ampacity limitation shall be in accordance with the 60 C conductor temperature rating, as specified in the National Electrical., Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations., Type, NM, -B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness., Assembly:, Jacket:, A 30-mil, color-coded., 14 AWG White PVC jacket is applied over the completed assembly., Standards:, Underwriters Laboratories Standards UL-83., UL-719, Federal Specification A-A-59544., ASTM-B3 and B8,, ARRA 2009., Section 1605 Buy American Compliant. Encore Wire Corp
P0686.jpg 8 AWG, Solid, Bare Copper Wire, 500’ Reel
Locke Part #: P0686 MFG Part #: 170101000040
Outside Diameter: 0.1285" (3.26 mm), Approximate Net Weight (lbs/1000 ft): 50.0, Number of Strands: Solid, Standard Packaging (ft): 500’, Area (cmils): 16,510, Size (AWG): 8, Soft-Drawn (Annealed) - DC Resistance (Ohms/1000 ft @ 20°C): 0.6407, Soft-Drawn (Annealed) - Rated Strength (lbs): 479 Highest conductivity per unit area of all common commercial metals., Excellent corrosion resistance., Flexible; easily worked and formed into place., Packaged on non-returnable spools for easy transportation to job sites and to provide adequate footage for mass installations., Good fatigue-resistance; not subject to breaks due to nicks or cuts when terminating., Totally recyclable with high scrap value., Contact your local representative for information on the Encore Wire Scrap Purchase Program., Construction:, Soft-Drawn Solid or Stranded, Annealed Bare Copper., Applications:, Copper conductors are used in overhead electrical transmission and distribution systems for grounding electrical systems, and where high-conductivity and flexibility are required for equipment and circuit grounding., Standards:, ASTM-B3 for soft-drawn solid copper wire., ASTM-B8 for soft-drawn concentric lay stranded copper wire., ASTM-B787 for 19-wire combination unilay stranded wire., ARRA 2009; Section 1605 "Buy American" Compliant. Encore Wire Corp
Color: Black, Outside Diameter: 0.212" (5.39 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 40, Allowable Ampacities (amps) @ 75°C: 50, Allowable Ampacities (amps) @ 90°C: 55, Size (AWG): 8, Approximate Net Weight: 62 lbs/1000 Ft (94 kg/km), Cross Sect Area (mm²): 8.37, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Green, Outside Diameter: 0.212" (5.39 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 40, Allowable Ampacities (amps) @ 75°C: 50, Allowable Ampacities (amps) @ 90°C: 55, Size (AWG): 8, Approximate Net Weight: 62 lbs/1000 Ft (94 kg/km), Cross Sect Area (mm²): 8.37, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: Red, Outside Diameter: 0.212" (5.39 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 40, Allowable Ampacities (amps) @ 75°C: 50, Allowable Ampacities (amps) @ 90°C: 55, Size (AWG): 8, Approximate Net Weight: 62 lbs/1000 Ft (94 kg/km), Cross Sect Area (mm²): 8.37, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Color: White, Outside Diameter: 0.212" (5.39 mm), Number of Strands: 19, Standard Packaging (ft): 500’, Allowable Ampacities (amps) @ 60°C: 40, Allowable Ampacities (amps) @ 75°C: 50, Allowable Ampacities (amps) @ 90°C: 55, Size (AWG): 8, Approximate Net Weight: 62 lbs/1000 Ft (94 kg/km), Cross Sect Area (mm²): 8.37, Nylon Jacket Thickness: 0.005" (0.130 mm), PVC Insulation Thickness (Conductor): 0.030" (0.760 mm) A great alternative to eliminate the need for lube. Slick Nylon outer jacket for easy pulling., SuperSlick Elite is available in sizes 8 AWG through 1000 KCMIL., All sizes rated gasoline and oil resistant II. On 250 KCMIL and larger, sequential footage markings located every foot for easy measuring., For 1 AWG through 4/0 AWG sequential foot markings located on master reels only unless otherwise specified., 6 AWG and larger Sunlight Resistant in all colors., 1/0 AWG and larger are rated for cable tray use and comply with IEEE 1202/FT4 (70,000 Btu/hr.) flame test and ICEA T-29-20 (210,000 Btu/hr.) flame test., Construction:, Conductors:, Solid, uncoated copper conductors per ASTM-B3, Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8, Insulation:, Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-83, Applications:, Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)., Type THHN/THWN-2 is permitted for new construction or rewiring for 600-volt applications., For applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90 C or not to exceed 75 C in oil or coolants., For applications requiring Type MTW, the conductor is appropriate for use in dry locations at 90 C, or not to exceed 60 C in wet locations or where exposed to oils or coolants., Applications requiring Type AWM (18 AWG - 1 AWG) conductor is appropriate for use at temperatures not exceeding 105 C in dry locations., Jacket:, A tough, polyamide, Nylon outer covering per UL-1063 and UL-83., Standards:, Underwriters Laboratories Standards UL-83, UL-1063, UL-758, AWM Spec 1316, 1317, 1318, 1319, 1320, 1321, ASTM Stranding Class B3, B8, B787, Federal Specification A-A-59544, Canadian Standards Association C22.2 No. 75, NEMA WC70/ICEA S-95-658, UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger), ICEA T-29-520 (210,000 Btu/hr) Flame Test, ARRA 2009; Section 1605 "Buy American" Compliant Encore Wire Corp
Ideal Industries
P2789.jpg DBO/B-6 DIRECT BURY SPLICE KIT
Locke Part #: P2789 MFG Part #: 051128-59075
Splices/Kit: 2-Orange/ Brown, Kits/ Case: 25 Direct bury splice kits splice and effectively moisture seal 2 or more conductors for remote control circuits in irrigation and landscape lighting systems. Rated for 600v. 3M
P2789.jpg DBR/Y-6 (KIT) UF SPLICE KIT
Locke Part #: P2790 MFG Part #: 051128-58573
Splices/Kit: 2-Red/ Yellow, Kits/ Case: 25 Direct bury splice kits splice and effectively moisture seal 2 or more conductors for remote control circuits in irrigation and landscape lighting systems. Rated for 600v. 3M
4SJOOW-14-03.jpg SJOOWA Portable Cord, 12 AWZ, 3 Conductor, 300V, Black
Locke Part #: P3841 MFG Part #: 12/3 SJOOW-A CORD 250' R
Voltage: 300 volts, Temperature: 90 °C, Length (ft): 250, Conductors: 3, Gauge (AWG): 12, Conductor Strand: 65/30, JACKET COLORS: Black, Insulation Thickness (In): 0.03, Outside Diameter (IN): 0.43, Weight/M’: 131 Conductor: Bare, annealed copper per ASTM B-3. Flexible, bunch stranded per UL62., A seperator may be applied over the conductor., Insulation: Synthetic rubber per UL 62., Meets UL and CSA requirements for Type SJOOW., Ampacity: Based on a 30 C ambient temperature per NEC Table 400-5(A), Column A. The values are derated (where applicable) according to NEC Article 400-5., For use with portable appliances, small motors and tools., Also, for light-load general use in equipment exposed to oils, solvents, flame, grease. PRIORITY WIRE & CABLE INC
4SJOOW-14-03.jpg SJOOWA Portable Cord, 14 AWZ, 3 Conductor, 300V, Black
Locke Part #: P3840 MFG Part #: 14/3 SJOOWA CORD 250' RE
Voltage: 300 volts, Temperature: 90 °C, Length (ft): 250, Conductors: 3, Gauge (AWG): 14, Conductor Strand: 41/30, JACKET COLORS: Black, Insulation Thickness (In): 0.03, Outside Diameter (IN): 0.36, Weight/M’: 88 Conductor: Bare, annealed copper per ASTM B-3. Flexible, bunch stranded per UL62., A seperator may be applied over the conductor., Insulation: Synthetic rubber per UL 62., Meets UL and CSA requirements for Type SJOOW., Ampacity: Based on a 30 C ambient temperature per NEC Table 400-5(A), Column A. The values are derated (where applicable) according to NEC Article 400-5., For use with portable appliances, small motors and tools., Also, for light-load general use in equipment exposed to oils, solvents, flame, grease. PRIORITY WIRE & CABLE INC
Product Image Not Available SJOOWA Portable Cord, 16 AWZ, 3 Conductor, 300V, Black
Locke Part #: P3839 MFG Part #: 16/3 SJOOWA CORD 250' RE
O.D. Inches: .325, STD. CTN.: 250’ PRIORITY WIRE & CABLE INC
4SJTOW-14-03.jpg SJTOW Portable Cord, 14 AWZ, 3 Conductor, 600V, Gray
Locke Part #: P3820 MFG Part #: 14/3 SJTO CORD GREY 250'
Voltage: 300 volts, Temperature: -40° C to 60° C, Length (ft): 250, Conductors: 3, Gauge (AWG): 14, Conductor Strand: 41/30, JACKET COLORS: Gray, Insulation Thickness (In): 0.03, Outside Diameter (IN): 0.363, Weight/M’: 116 Conductor: Annealed, bare copper per ASTM B-3. Flexible, bunch stranded per UL 62., Insulation: Color coded Polyvinyl chloride (PVC) per UL 62., Standards: Meets UL and CSA requirements for Type STO., Ampacity: Based on a 30 C ambient temperature per NEC Table 400-5(A), Column A., For use as power cords on machine tools, portable power equipment and appliances., Designed for hard usage with portable tools, equipment and motors. PRIORITY WIRE & CABLE INC
4SOOW-08-03.jpg SOOWA Portable Cord, 10 AWZ, 3 Conductor, 600V, Black
Locke Part #: P0676 MFG Part #: 10/3 SOOW-A CORD 250' RE
O.D. Inches: .655, STD. CTN.: 250’ Conductor: Bare, annealed copper per ASTM B-3. Flexible, bunch stranded per UL62., A seperator may be applied over the conductor., Insulation: Synthetic rubber per UL 62., Meets UL and CSA requirements for Type SJOOW., Ampacity: Based on a 30 C ambient temperature per NEC Table 400-5(A), Column A. The values are derated (where applicable) according to NEC Article 400-5., For use as portable electrical power and portable control cable, Can be used for ground test or motor leads., Also, it provides heavy-duty service for industrial tools, portable lights, battery chargers, and equipment exposed to oils, solvents, flame and grease. PRIORITY WIRE & CABLE INC
4SOOW-08-03.jpg SOOWA Portable Cord, 10 AWZ, 4 Conductor, 600V, Black
Locke Part #: P3835 MFG Part #: 10/4 SOOWA CORD 250' REE
O.D. Inches: .710, STD. CTN.: 250’ Conductor: Bare, annealed copper per ASTM B-3. Flexible, bunch stranded per UL62., A seperator may be applied over the conductor., Insulation: Synthetic rubber per UL 62., Meets UL and CSA requirements for Type SJOOW., Ampacity: Based on a 30 C ambient temperature per NEC Table 400-5(A), Column A. The values are derated (where applicable) according to NEC Article 400-5., For use as portable electrical power and portable control cable, Can be used for ground test or motor leads., Also, it provides heavy-duty service for industrial tools, portable lights, battery chargers, and equipment exposed to oils, solvents, flame and grease. PRIORITY WIRE & CABLE INC
4SOOW-08-03.jpg SOOWA Portable Cord, 12 AWZ, 3 Conductor, 600V, Black
Locke Part #: P0677 MFG Part #: 12/3 SOOW-A CORD 250' RE
Voltage: 600 volts, Temperature: -40 °C to 90 °C and -40°C – 105°C, Length (ft): 250, Conductors: 3, Gauge (AWG): 12, Conductor Strand: 65/30, JACKET COLORS: Black, Insulation Thickness (In): 0.045, Outside Diameter (IN): 0.59, Weight/M’: 217 Conductor: Bare, annealed copper per ASTM B-3. Flexible, bunch stranded per UL62., A seperator may be applied over the conductor., Insulation: Synthetic rubber per UL 62., Meets UL and CSA requirements for Type SJOOW., Ampacity: Based on a 30 C ambient temperature per NEC Table 400-5(A), Column A. The values are derated (where applicable) according to NEC Article 400-5., For use as portable electrical power and portable control cable, Can be used for ground test or motor leads., Also, it provides heavy-duty service for industrial tools, portable lights, battery chargers, and equipment exposed to oils, solvents, flame and grease. PRIORITY WIRE & CABLE INC
4SOOW-08-03.jpg SOOWA Portable Cord, 12 AWZ, 4 Conductor, 600V, Black
Locke Part #: P3834 MFG Part #: 12/4 SOOWA CORD 250' REE
Voltage: 600 volts, Temperature: -40 °C to 90 °C and -40°C – 105°C, Length (ft): 250, Conductors: 4, Gauge (AWG): 12, Conductor Strand: 65/30, JACKET COLORS: Black, Insulation Thickness (In): 0.045, Outside Diameter (IN): 0.64, Weight/M’: 261 Conductor: Bare, annealed copper per ASTM B-3. Flexible, bunch stranded per UL62., A seperator may be applied over the conductor., Insulation: Synthetic rubber per UL 62., Meets UL and CSA requirements for Type SJOOW., Ampacity: Based on a 30 C ambient temperature per NEC Table 400-5(A), Column A. The values are derated (where applicable) according to NEC Article 400-5., For use as portable electrical power and portable control cable, Can be used for ground test or motor leads., Also, it provides heavy-duty service for industrial tools, portable lights, battery chargers, and equipment exposed to oils, solvents, flame and grease. PRIORITY WIRE & CABLE INC
4SOOW-08-03.jpg SOOWA Portable Cord, 14 AWZ, 4 Conductor, 600V, Black
Locke Part #: P3833 MFG Part #: 14/4 SOOWA CORD 250' REE
Voltage: 600 volts, Temperature: -40 °C to 90 °C and -40°C – 105°C, Length (ft): 250, Conductors: 4, Gauge (AWG): 14, Conductor Strand: 41/30, JACKET COLORS: Black, Insulation Thickness (In): 0.045, Outside Diameter (IN): 0.57, Weight/M’: 192 Conductor: Bare, annealed copper per ASTM B-3. Flexible, bunch stranded per UL62., A seperator may be applied over the conductor., Insulation: Synthetic rubber per UL 62., Meets UL and CSA requirements for Type SJOOW., Ampacity: Based on a 30 C ambient temperature per NEC Table 400-5(A), Column A. The values are derated (where applicable) according to NEC Article 400-5., For use as portable electrical power and portable control cable, Can be used for ground test or motor leads., Also, it provides heavy-duty service for industrial tools, portable lights, battery chargers, and equipment exposed to oils, solvents, flame and grease. PRIORITY WIRE & CABLE INC
4SOOW-08-03.jpg SOOWA Portable Cord, 16 AWZ, 3 Conductor, 600V, Black
Locke Part #: P0679 MFG Part #: 16/3 SOOW-A CORD 250' RE
Voltage: 600 volts, Temperature: -40 °C to 90 °C and -40°C – 105°C, Length (ft): 250, Conductors: 3, Gauge (AWG): 16, Conductor Strand: 26/30, JACKET COLORS: Black, Insulation Thickness (In): 0.03, Outside Diameter (IN): 0.39, Weight/M’: 90 Conductor: Bare, annealed copper per ASTM B-3. Flexible, bunch stranded per UL62., A seperator may be applied over the conductor., Insulation: Synthetic rubber per UL 62., Meets UL and CSA requirements for Type SJOOW., Ampacity: Based on a 30 C ambient temperature per NEC Table 400-5(A), Column A. The values are derated (where applicable) according to NEC Article 400-5., For use as portable electrical power and portable control cable, Can be used for ground test or motor leads., Also, it provides heavy-duty service for industrial tools, portable lights, battery chargers, and equipment exposed to oils, solvents, flame and grease. PRIORITY WIRE & CABLE INC
4SOOW-08-03.jpg SOOWA Portable Cord, 16 AWZ, 4 Conductor, 600V, Black
Locke Part #: P3832 MFG Part #: 16/4 SOOWA CORD 250' REE
Voltage: 600 volts, Temperature: -40 °C to 90 °C and -40°C – 105°C, Length (ft): 250, Conductors: 4, Gauge (AWG): 16, Conductor Strand: 26/30, JACKET COLORS: Black, Insulation Thickness (In): 0.03, Outside Diameter (IN): 0.42, Weight/M’: 115 Conductor: Bare, annealed copper per ASTM B-3. Flexible, bunch stranded per UL62., A seperator may be applied over the conductor., Insulation: Synthetic rubber per UL 62., Meets UL and CSA requirements for Type SJOOW., Ampacity: Based on a 30 C ambient temperature per NEC Table 400-5(A), Column A. The values are derated (where applicable) according to NEC Article 400-5., For use as portable electrical power and portable control cable, Can be used for ground test or motor leads., Also, it provides heavy-duty service for industrial tools, portable lights, battery chargers, and equipment exposed to oils, solvents, flame and grease. PRIORITY WIRE & CABLE INC
4SOOW-08-03.jpg SOOWA Portable Cord, 6 AWZ, 3 Conductor, 600V, Black
Locke Part #: P3817 MFG Part #: 6/3 SOOWA CORD 250' REEL
O.D. Inches: .930, STD. CTN.: 250’ Conductor: Bare, annealed copper per ASTM B-3. Flexible, bunch stranded per UL62., A seperator may be applied over the conductor., Insulation: Synthetic rubber per UL 62., Meets UL and CSA requirements for Type SJOOW., Ampacity: Based on a 30 C ambient temperature per NEC Table 400-5(A), Column A. The values are derated (where applicable) according to NEC Article 400-5., For use as portable electrical power and portable control cable, Can be used for ground test or motor leads., Also, it provides heavy-duty service for industrial tools, portable lights, battery chargers, and equipment exposed to oils, solvents, flame and grease. PRIORITY WIRE & CABLE INC
4SOOW-08-03.jpg SOOWA Portable Cord, 6 AWZ, 4 Conductor, 600V, Black
Locke Part #: P3837 MFG Part #: 6/4 SOOWA CORD 250' REEL
O.D. Inches: 1.055, STD. CTN.: 250’ Conductor: Bare, annealed copper per ASTM B-3. Flexible, bunch stranded per UL62., A seperator may be applied over the conductor., Insulation: Synthetic rubber per UL 62., Meets UL and CSA requirements for Type SJOOW., Ampacity: Based on a 30 C ambient temperature per NEC Table 400-5(A), Column A. The values are derated (where applicable) according to NEC Article 400-5., For use as portable electrical power and portable control cable, Can be used for ground test or motor leads., Also, it provides heavy-duty service for industrial tools, portable lights, battery chargers, and equipment exposed to oils, solvents, flame and grease. PRIORITY WIRE & CABLE INC
4SOOW-08-03.jpg SOOWA Portable Cord, 8 AWZ, 3 Conductor, 600V, Black
Locke Part #: P3816 MFG Part #: 8/3 SOOWA CORD 250' REEL
Voltage: 600 volts, Temperature: -40 °C to 90 °C and -40°C – 105°C, Length (ft): 250, Conductors: 3, Gauge (AWG): 08, Conductor Strand: 133/29, JACKET COLORS: Black, Insulation Thickness (In): 0.06, Outside Diameter (IN): 0.68, Weight/M’: 326 Conductor: Bare, annealed copper per ASTM B-3. Flexible, bunch stranded per UL62., A seperator may be applied over the conductor., Insulation: Synthetic rubber per UL 62., Meets UL and CSA requirements for Type SJOOW., Ampacity: Based on a 30 C ambient temperature per NEC Table 400-5(A), Column A. The values are derated (where applicable) according to NEC Article 400-5., For use as portable electrical power and portable control cable, Can be used for ground test or motor leads., Also, it provides heavy-duty service for industrial tools, portable lights, battery chargers, and equipment exposed to oils, solvents, flame and grease. PRIORITY WIRE & CABLE INC
4SOOW-08-03.jpg SOOWA Portable Cord, 8 AWZ, 3 Conductor, 600V, Black
Locke Part #: P3836 MFG Part #: 8/4 SOOWA CORD 250' REEL
Voltage: 600 volts, Temperature: -40 °C to 90 °C and -40°C – 105°C, Length (ft): 250, Conductors: 4, Gauge (AWG): 08, Conductor Strand: 133/29, JACKET COLORS: Black, Insulation Thickness (In): 0.06, Outside Diameter (IN): 0.74, Weight/M’: 410 Conductor: Bare, annealed copper per ASTM B-3. Flexible, bunch stranded per UL62., A seperator may be applied over the conductor., Insulation: Synthetic rubber per UL 62., Meets UL and CSA requirements for Type SJOOW., Ampacity: Based on a 30 C ambient temperature per NEC Table 400-5(A), Column A. The values are derated (where applicable) according to NEC Article 400-5., For use as portable electrical power and portable control cable, Can be used for ground test or motor leads., Also, it provides heavy-duty service for industrial tools, portable lights, battery chargers, and equipment exposed to oils, solvents, flame and grease. PRIORITY WIRE & CABLE INC