Loading ...

Loading ...

Search in: Refrigerant Category

L1387.jpg 24 lb. Refrigerant #R408A
Locke Part #: L0849 MFG Part #: 408A 24#
Physical State: 24 LB 408A REFRIGERANT A retrofit solution for medium & low temperature refrigeration systems which are currently using R502. Arkema Inc
Physical State: 30 LB. R409A FX56 Arkema Inc
hs2.jpg HOT SHOT-2 25 lb cylinder
Locke Part #: L1244 MFG Part #: HS2-25
Warranty: 18 months from date code if seal is not broken, Color: Colorless, Type: 19.5% R-125, 78.8% R-134a, 1.7% R-600, Odor: Slightly Ethereal, pH: Neutral, Physical State: Gas at Ambient Temperature, Solubility In Water: Not Determined, Boiling Point (DEW @ 1 ATM): -20.5° F, Boiling Point (Bubble @ 1 ATM): -26.7° F, MolecularWeight: 103.7 G/MOL, Density (Liquid @ 1 ATM): 85.91 LB/FT3, Density (VAPOR @ 1 ATM): 0.3374 LB/FT3, Vapor Pressure @ 68 Deg F: 96.7 PSIA, Vapor Pressure @ 140 Deg F: 238.1 PSIA, Volatiles (% ): 100, Package Size: 25 lb cylinder, Global Warming Potential: 1820, Oil Compatibility: All, Molar Mass (Ibm/Ibmol): 103.73, Critical Pressure (Psia): 590.85, Critical Temperature (°F): 203.7, Critical Density (Ibm/ft3): 32.12, Liquid Density (70°F, Ibm/ft3): 74.6, Temperature Glide (NBP): 6, Pounds Per Gallon (70 °F): 9.97, Maximum High Boiling Impurities (% vol): 0.01, Recommended Maximum Exposure Limits in Air (ppm): 1000, Evaporator Temperature Range: -15° F to 50° F, R-125 (% Weight): 19.5 Zero Ozone Depletion Potential, Non Toxic and Non Flammable, HFC - Ozone Safe, Compatible with all compressor oils, Can be topped off after leak has been repaired, Widespread availability, No oil change to AB or POE, ASHRAE Designated R-417C, No TEV or cap tube replacement, Replaces R-12, R-134a, R-500, R-401A/B, R-409A, R-414B, R-416A, R-420A, R-426A, R-437 & R-414A in most applications., EPA SNAP Listed - Stationary Equipment Only, R-12 and 134a low, medium and high temp refrigeration, R-12 and 500 air conditioning ICOR INTERNATIONAL INC 834674000000
nub.jpg NU-22B (25lb cylinder)
Locke Part #: L1243 MFG Part #: R422B
Warranty: 18 months from date code if seal is not broken, Color: Colorless, Type: 55% R-125, 42% R-134a, 3% R-600a, Odor: Slightly Ethereal, pH: Neutral, Physical State: Gas at Ambient Temperature, Solubility In Water: Not Determined, Boiling Point (DEW @ 1 ATM): -32.15° F, Boiling Point (Bubble @ 1 ATM): -40.86° F, MolecularWeight: 108.53 G/MOL, Density (Liquid @ 1 ATM): 87.25 LB/FT3, Density (VAPOR @ 1 ATM): 0.3633 LB/FT3, Vapor Pressure @ 68 Deg F: 116.0 PSIA, Vapor Pressure @ 140 Deg F: 328.0 PSIA, Volatiles (% ): 100, Package Size: 25 lb cylinder, Global Warming Potential: 2500, Oil Compatibility: All, Molar Mass (Ibm/Ibmol): 108.52, Critical Pressure (Psia): 574.07, Critical Temperature (°F): 181.79, Critical Density (Ibm/ft3): 32.86, Liquid Density (70°F, Ibm/ft3): 73.053, Temperature Glide (NBP): 10, Pounds Per Gallon (70 °F): 9.76, Maximum High Boiling Impurities (% vol): 0.01, Recommended Maximum Exposure Limits in Air (ppm): 1000, Evaporator Temperature Range: 0° F to 50° F, R-125 (% Weight): 55 EPA SNAP listed R-22 replacement., ASHRAE designated R-422B., Has the ASHRAE safety classification, A1 (nontoxic/nonflammable)., Can be used in MO, AB and POE designed systems. No unnecessary oil change is required., Greater capacity than its predecessor, R-417A., Its operating pressures are closer to R-22 than any other R-22 replacement on the market today., Successfully used in system applications ranging from residential to industrial., Available through wholesale distributors from coast to coast., 15-20% less expensive than its predecessor., Available in 25 lb. disposable cylinders and bulk refillable cylinders., Produced in the USA and packaged in American made cylinders., Non-ozone depleting, Non-toxic., No line set changes., Can be tapped off after leak has been repaired., Enable continued use of existing equipment., Can use R-22 TEV and power element., Widespread availability., Replaces R-22, R-407C, R-417A, R-421A, R-422D, R-424A, R-427A, R-434A, R-438A. ICOR INTERNATIONAL INC 834674000000
os.jpg ONE SHOT-C 24 # cylinder
Locke Part #: L1302 MFG Part #: OS-24
Warranty: 18 months from date code if seal is not broken, Color: Colorless, Type: 82% R-125, 15% R-134a, 3% R-600a, Odor: Slightly Ethereal, pH: Neutral, Physical State: Gas at Ambient Temperature, Solubility In Water: Not Determined, Boiling Point (DEW @ 1 ATM): -45.1° F, Boiling Point (Bubble @ 1 ATM): -50.7° F, MolecularWeight: 113.49 G/MOL, Density (Liquid @ 1 ATM): 89.20 LB/FT3, Density (VAPOR @ 1 ATM): 0.3912 LB/FT3, Vapor Pressure @ 68 Deg F: 155.6 PSIA, Vapor Pressure @ 140 Deg F: 360.1 PSIA, Volatiles (% ): 100, Package Size: 24 lb cylinder, Global Warming Potential: 3100, Oil Compatibility: All, Molar Mass (Ibm/Ibmol): 113.4, Critical Pressure (Psia): 547.70, Critical Temperature (°F): 163.53, Critical Density (Ibm/ft3): 33.739, Liquid Density (70°F, Ibm/ft3): 72.663, Temperature Glide (NBP): 5, Pounds Per Gallon (70 °F): 9.71, Maximum High Boiling Impurities (% vol): 0.01, Recommended Maximum Exposure Limits in Air (ppm): 1000, Evaporator Temperature Range: -40° F to 30° F, R-125 (% Weight): 82 ASHRAE R-422C, Higher Capacity & COP than R-404A & R507A, 20% Lower Global Warming Potential Compatible with MO, AB, and Poe Based Oils, Zero Ozone Depletion Potential, Non Toxic and Nonflammable, Suitable For New and Existing Equipment Can Be Topped Off Repeatedly, HFC Leak Detectors Suitable For Use with One Shot (C), Replaces R-402A, R-402B, R-404A, R-408A, R-502, and R-507A. Also replaces R-22 for low-temperature and medium-temperature applications., Can use R-502/404A TEV and power element., Can be tapped off after leak has been repaired., 20% lower GWP vs. 404A and 507A, Significantly lower energy usage vs. 22 in med and low temp refrigeration. ICOR INTERNATIONAL INC 834674000000
R22.jpg R-22 - 30 LB Cylinder
Locke Part #: L0848 MFG Part #: RACON 22 30#
Color: 1.91 @ 4 C, Odor: Clear, Colorless Liquified Gas, pH: -160 C (Freezing Point), Physical State: -40.8 C, Solubility In Water: Mild Ether Like, Boiling Point (DEW @ 1 ATM): 136 PSIA @ 21 C, Boiling Point (Bubble @ 1 ATM): 2.98 @ 1 atm, MolecularWeight: 36.25 lbs, Density (Liquid @ 1 ATM): 36.25 lbs, Density (VAPOR @ 1 ATM): 20, Vapor Pressure @ 68 Deg F: 40, Vapor Pressure @ 140 Deg F: 1450 lbs, Volatiles (% ): Slight, Package Size: 1.91 @ 25 C (g/cm3) Johnsen's R-22 is for use in factory installed and/or retrofitted R-22 air conditioning systems., Comes with standard 1/4 HVAC male fitting. Arkema Inc
404A.jpg R-404A - 24 lb. Cylinder, Orange
Locke Part #: L1388 MFG Part #: HFC-404A-#24
Color: A1, Odor: 97.6, pH: -51.2, Solubility In Water: 420-46-2, 354-33-6, 811-97-2, Boiling Point (DEW @ 1 ATM): 1,1,1-Trifluoroethane, Pentafluoroethane, 1,1,1,2-Tetrafluoroethane, Boiling Point (Bubble @ 1 ATM): 24 lb., MolecularWeight: Cylinder, Density (Liquid @ 1 ATM): 161.7, Density (VAPOR @ 1 ATM): Orange, Vapor Pressure @ 68 Deg F: 3943, Vapor Pressure @ 140 Deg F: Polyol Ester, Volatiles (% ): R-404A Applications:, Boats / vessels,Cooling cases, Food processing, Refrigerated containers, Refrigerated trucks, Refrigerators, Vending machines, Wine coolers Arkema Inc
407C.jpg R-407C - 25 lb. Cylinder, Orange
Locke Part #: L1241 MFG Part #: R407C 25LB
Color: A1, Odor: 86.2, pH: -46.5, Solubility In Water: 811-97-2, 354-33-6, 75-10-5, Boiling Point (DEW @ 1 ATM): 1,1,1,2-Tetrafluoroethane, Pentafluoroethane, Difluoromethane, Boiling Point (Bubble @ 1 ATM): 25 lb., MolecularWeight: Cylinder, Density (Liquid @ 1 ATM): 186.9, Density (VAPOR @ 1 ATM): Orange, Vapor Pressure @ 68 Deg F: 1,624, Vapor Pressure @ 140 Deg F: Polyol Ester, Volatiles (% ): R-407C Applications:, Air conditioning units, Centrifugal chiller, Chillers, Non-flooded evaporator chillers, Screw chiller, Small chillers Arkema Inc
410Cylinder.jpg R-410A - 25 LB Cylinder
Locke Part #: L1384 MFG Part #: R410A 25#
Color: -55.4 F (-48.5 C), Odor: 1.08 @ 70 F (21.1 C), pH: 1250 lbs, Physical State: NA Gas, Solubility In Water: Clear, Colorless Liquid/Vapor, Boiling Point (DEW @ 1 ATM): Ether Like, Boiling Point (Bubble @ 1 ATM): 215.3 psia @ 70 F, MolecularWeight: 3.0, Density (Liquid @ 1 ATM): 31.25 lbs, Density (VAPOR @ 1 ATM): 31.25 lbs, Vapor Pressure @ 68 Deg F: 20, Vapor Pressure @ 140 Deg F: 40 For use in factory installed and/or retrofitted R-410A conditioning systems, Comes with standard 1/4 HVAC male fitting. Arkema Inc
Model: R134a, Warranty: 1 Year from date of manufacture, Color: Gas, Odor: Ether Like, pH: Gas, Physical State: -26 °C, Solubility In Water: 5720 hPa, Boiling Point (DEW @ 1 ATM): 36.25 lbs, Boiling Point (Bubble @ 1 ATM): 36.25 lbs, MolecularWeight: 20, Density (Liquid @ 1 ATM): 40, Density (VAPOR @ 1 ATM): 1450 lbs, Vapor Pressure @ 68 Deg F: -101 °C, Vapor Pressure @ 140 Deg F: 102.03 g/mol, Volatiles (% ): Colourless R-134a is for use in factory installed and/or retrofitted R-134a air conditioning systems., Comes with standard 1/4 HVAC male fitting. Dynatemp Intl 610320134301
Model: R421A, Warranty: 1 Year from date of manufacture Dynatemp Intl 851859000181