CPS CE-9I Leak Detection System, 100 to 240 V

by: CPS Products

Locke# T6118 | Mfg# CE-9I
T6118

CPS CE-9I Leak Detection System, 100 to 240 V

by: CPS Products

Locke# T6118 | Mfg# CE-9I

For pricing and availability please Sign In

*Item only available: AR, KS, MO, OK, TX, VA

  • Product Featuresarrow_drop_down
    • Quickly and accurately pinpoints gas leak sites by releasing low-pressure, nontoxic smoke into target areas
    • Citrus-scented, white vapor can be identified visually, by scent or by tracing its UV dye
    • Built into hard carrying case with handle for easy storage and portability
    • Wide operating temperature range for use in a variety of settings
    • 32 oz (0.9 L) maximum Ultratrace UV Volume
    • 50 to 175 psi (3.4 to 12 bar) Inlet Pressure Required
    • 5 psi (0.34 bar) (34 kPa) Supply Pressure
    • 26.4 gal (100 L) per minute Supply Volume
    • Up to 6,561 (2,000 m) Maximum Altitude
    • 10 A (2 required) Fuse
    • UltraTrace UV trace dye Smoke
    • 45 to 140°F (7.2 to 60°C) Operating Temperature
    • 50, 60 Hz Power Supply
  • Specificationsarrow_drop_down
    • Amperage Rating: 10 A
    • Cord Type: Power
    • Detects: Somke Leak
    • Height: 26 in
    • Length: 10.5 in
    • Voltage Rating: 100 to 240 V
    • Width: 16.5 in
  • Resourcesarrow_drop_down
  • Tagsarrow_drop_down