Loading ...

Loading ...

Search in: Transfer Switches Category

P5936.jpg100A N3R Auto Switch Only
Locke Part #: P5936MFG Part #: RTSC100A3 Compare
P5936.jpg100A N3R Service Entrance Rated
Locke Part #: P5937MFG Part #: RTSW100A3 Compare
P6750.jpg100A Transfer Switch, Includes Neutral Kit
Locke Part #: P6750MFG Part #: DT223URK-NPS Compare
P5936.jpg200A N3R Auto Switch Only
Locke Part #: P5938MFG Part #: RTSC200A3 Compare
P5936.jpg200A N3R Service Entrance Rated
Locke Part #: P5939MFG Part #: RTSW200A3 Compare
P6750.jpg200A Transfer Switch, Includes Neutral Kit
Locke Part #: P6751MFG Part #: DT224URK-NPS Compare
MA23-N.jpg30 Amp Non-Surge Meter Generator Connector
Locke Part #: P9270MFG Part #: MA23-N-GLC20-2 Compare
Weight (Lbs): 5-1/2, Depth (in): 5-1/4, Diameter: 6-1/2", MFG#: MA23-N, Temperature Range: -30°C to 60°C External Ambient, Socket Style: Ring or Ring-less, 200 Amp, 4 jaw, Source Compatibility: 200 Ampere or less, Generator Input: 10kW Continuous†, 120/240 Volt, Transfer Type: Break–Before–Make, Transfer Delay: 2-3 Seconds, Life Cycle: 300,000 Operations GenerLink eliminates the use of extension cords and other connections that can be hazardous to customers and utility personnel., GenerLink detects when a generator is operating and automatically disconnects from the utility grid, eliminating dangerous backfeed., GenerLink is equipped with GenerLok, a unique interlocking power cord system that provides a quick and easy connection of a portable generator., GenerLink is installed in 20 minutes or less by utility personnel and does not require the customer s presence., GenerLink is easily installed behind a customer s electric meter and requires no rewiring of the customer s electrical system., With GenerLink, customers have the flexibility to run virtually any appliance, up to the capacity of their generator by simply energizing appliances from their breaker panel., Specifications:, Generator Input, Generator Input Voltage > 200 Volts, Protection, Supplemental Overcurrent < 40 A, Utility Input, Utility Input Voltage > 180 Volts, Protection, Over-Temperature Trip > 105 C, Load, Integrated Whole-House, Protection, Surge Protection Model MA23/24 - S Only, Electrical:, Withstand Current, 10,000 Amperes rms symmetrical at .7 - .8 pf, 240 Volts, 60 Hz, 6000 Amperes for 6 cycles at .7 - .8 pf, 240Volts, 60 Hz, Connection, Proprietary GenerLoc QuickConnect Cord
MA23-N.jpg30 Amp Surge Meter Generator Connector
Locke Part #: P9271MFG Part #: MA23-S-GLC20-2 Compare
Weight (Lbs): 5-3/4, Depth (in): 5-1/4, Diameter: 6-1/2", MFG#: MA23-S, Temperature Range: -30°C to 60°C External Ambient, Socket Style: Ring or Ring-less, 200 Amp, 4 jaw, Source Compatibility: 200 Ampere or less, Generator Input: 10kW Continuous†, 120/240 Volt, Transfer Type: Break–Before–Make, Transfer Delay: 2-3 Seconds, Life Cycle: 300,000 Operations GenerLink eliminates the use of extension cords and other connections that can be hazardous to customers and utility personnel., GenerLink detects when a generator is operating and automatically disconnects from the utility grid, eliminating dangerous backfeed., GenerLink is equipped with GenerLok, a unique interlocking power cord system that provides a quick and easy connection of a portable generator., GenerLink is installed in 20 minutes or less by utility personnel and does not require the customer s presence., GenerLink is easily installed behind a customer s electric meter and requires no rewiring of the customer s electrical system., With GenerLink, customers have the flexibility to run virtually any appliance, up to the capacity of their generator by simply energizing appliances from their breaker panel., Specifications:, Generator Input, Generator Input Voltage > 200 Volts, Protection, Supplemental Overcurrent < 40 A, Utility Input, Utility Input Voltage > 180 Volts, Protection, Over-Temperature Trip > 105 C, Load, Integrated Whole-House, Protection, Surge Protection Model MA23/24 - S Only, Electrical:, Withstand Current, 10,000 Amperes rms symmetrical at .7 - .8 pf, 240 Volts, 60 Hz, 6000 Amperes for 6 cycles at .7 - .8 pf, 240Volts, 60 Hz, Connection, Proprietary GenerLoc QuickConnect Cord
MA23-N.jpg40 Amp Non-Surge Meter Generator Connector
Locke Part #: P9272MFG Part #: MA24-N-GLC20-3 Compare
Weight (Lbs): 5-1/2, Depth (in): 5-1/4, Diameter: 6-1/2", MFG#: MA24-N, Temperature Range: -30°C to 60°C External Ambient, Socket Style: Ring or Ring-less, 200 Amp, 4 jaw, Source Compatibility: 200 Ampere or less, Generator Input: 10kW Continuous†, 120/240 Volt, Transfer Type: Break–Before–Make, Transfer Delay: 2-3 Seconds, Life Cycle: 300,000 Operations GenerLink eliminates the use of extension cords and other connections that can be hazardous to customers and utility personnel., GenerLink detects when a generator is operating and automatically disconnects from the utility grid, eliminating dangerous backfeed., GenerLink is equipped with GenerLok, a unique interlocking power cord system that provides a quick and easy connection of a portable generator., GenerLink is installed in 20 minutes or less by utility personnel and does not require the customer s presence., GenerLink is easily installed behind a customer s electric meter and requires no rewiring of the customer s electrical system., With GenerLink, customers have the flexibility to run virtually any appliance, up to the capacity of their generator by simply energizing appliances from their breaker panel., Specifications:, Generator Input, Generator Input Voltage > 200 Volts, Protection, Supplemental Overcurrent < 40 A, Utility Input, Utility Input Voltage > 180 Volts, Protection, Over-Temperature Trip > 105 C, Load, Integrated Whole-House, Protection, Surge Protection Model MA23/24 - S Only, Electrical:, Withstand Current, 10,000 Amperes rms symmetrical at .7 - .8 pf, 240 Volts, 60 Hz, 6000 Amperes for 6 cycles at .7 - .8 pf, 240Volts, 60 Hz, Connection, Proprietary GenerLoc QuickConnect Cord
MA23-N.jpg40 Amp Surge Meter Generator Connector
Locke Part #: P9273MFG Part #: MA24-S-GLC20-3 Compare
Weight (Lbs): 5-3/4, Depth (in): 5-1/4, Diameter: 6-1/2", MFG#: MA24-S, Temperature Range: -30°C to 60°C External Ambient, Socket Style: Ring or Ring-less, 200 Amp, 4 jaw, Source Compatibility: 200 Ampere or less, Generator Input: 10kW Continuous†, 120/240 Volt, Transfer Type: Break–Before–Make, Transfer Delay: 2-3 Seconds, Life Cycle: 300,000 Operations GenerLink eliminates the use of extension cords and other connections that can be hazardous to customers and utility personnel., GenerLink detects when a generator is operating and automatically disconnects from the utility grid, eliminating dangerous backfeed., GenerLink is equipped with GenerLok, a unique interlocking power cord system that provides a quick and easy connection of a portable generator., GenerLink is installed in 20 minutes or less by utility personnel and does not require the customer s presence., GenerLink is easily installed behind a customer s electric meter and requires no rewiring of the customer s electrical system., With GenerLink, customers have the flexibility to run virtually any appliance, up to the capacity of their generator by simply energizing appliances from their breaker panel., Specifications:, Generator Input, Generator Input Voltage > 200 Volts, Protection, Supplemental Overcurrent < 40 A, Utility Input, Utility Input Voltage > 180 Volts, Protection, Over-Temperature Trip > 105 C, Load, Integrated Whole-House, Protection, Surge Protection Model MA23/24 - S Only, Electrical:, Withstand Current, 10,000 Amperes rms symmetrical at .7 - .8 pf, 240 Volts, 60 Hz, 6000 Amperes for 6 cycles at .7 - .8 pf, 240Volts, 60 Hz, Connection, Proprietary GenerLoc QuickConnect Cord
P5936.jpg400A N3R Service Entrance Rated
Locke Part #: P5947MFG Part #: RTSW400A3 Compare
P4030-TypicalInstall.jpg50A Transfer Switch 12-16 Circuit
Locke Part #: P4039MFG Part #: 6380 Compare
Wires like a Subpanel, Expandable to 10 circuits using standard breakers, Reconfigurable using standard breakers, For surface mounting indoors, Allows hardwiring or plug-in generator connections (not all models), UL Listed with Siemens, Square D (HOM), Cutler-Hammer (BR) and GE (THQL) Breakers., Accommodates Arc Fault and GFCI breakers to meet 2008 NEC requirements*, UL 1008. Made in USA. Standard 2-year warranty against mechanical defects. Optional flush trim kit available when flush mounting is desired
P5936.jpg5A 600V Fuse for Generac Transfer Switches
Locke Part #: P6437MFG Part #: SBS5 Compare
Wires like a Subpanel, Expandable to 10 circuits using standard breakers, Reconfigurable using standard breakers, For surface mounting indoors, Allows hardwiring or plug-in generator connections (not all models), UL Listed with Siemens, Square D (HOM), Cutler-Hammer (BR) and GE (THQL) Breakers., Accommodates Arc Fault and GFCI breakers to meet 2008 NEC requirements*, UL 1008. Made in USA. Standard 2-year warranty against mechanical defects. Optional flush trim kit available when flush mounting is desired