Color: Black-White, Approximate Net Weight (lbs/1000 ft): 153, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, AWG/No: 10/2, Green Ground: 10 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.510 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Black-White, Approximate Net Weight (lbs/1000 ft): 153, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, AWG/No: 10/2, Green Ground: 10 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.510 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Black-White, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, AWG/No: 10/2, Conductors - Type: Solid, Ground: 8 Solid AL, Outside Diameter Over Armor (in): 0.502, Total Weight of Type MC - Copper Conductor (lbs/1000 ft): 133 Construction:, Conductors:, Available in sizes 14 AWG through 10 AWG. Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry., All conductors are individually wrapped with flame retardant colored protective paper with print legend and cabled together to form the cable core., The bare aluminum grounding/bonding conductor is located outside the paper wrap and is cabled with the insulated conductors and in constant contact with sheathing,, Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Permitted in Class I Div. 2, Class II Div. 2, and Class III Div. 1 Hazardous Locations., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Allowable installations in approved raceways and cable trays (NEC 392)., Suitable for installation under raised floors for IT equipment (NEC 645.5)., Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems., Standards:
Color: Black-White, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 60°C: 30, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, AWG/No: 10/2, Conductors - Type: Solid, Ground: 8 Solid AL, Outside Diameter Over Armor (in): 0.502, Total Weight of Type MC - Copper Conductor (lbs/1000 ft): 133 Construction:, Conductors:, Available in sizes 14 AWG through 10 AWG. Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry., All conductors are individually wrapped with flame retardant colored protective paper with print legend and cabled together to form the cable core., The bare aluminum grounding/bonding conductor is located outside the paper wrap and is cabled with the insulated conductors and in constant contact with sheathing,, Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Permitted in Class I Div. 2, Class II Div. 2, and Class III Div. 1 Hazardous Locations., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Allowable installations in approved raceways and cable trays (NEC 392)., Suitable for installation under raised floors for IT equipment (NEC 645.5)., Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems., Standards:
Color: Black-White-Red, Approximate Net Weight (lbs/1000 ft): 193, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, AWG/No: 10/3, Green Ground: 10 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.549 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Black-White-Red, Approximate Net Weight (lbs/1000 ft): 193, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 30, Allowable Ampacities (amps) @ 90°C: 30, AWG/No: 10/3, Green Ground: 10 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.549 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Black-White, Approximate Net Weight (lbs/1000 ft): 106, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/2, Green Ground: 12 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.487 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Black-White, Approximate Net Weight (lbs/1000 ft): 106, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/2, Green Ground: 12 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.487 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Blue-White, Approximate Net Weight (lbs/1000 ft): 106, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/2, Green Ground: 12 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.487 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Red-White, Approximate Net Weight (lbs/1000 ft): 106, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/2, Green Ground: 12 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.487 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Black-White, Approximate Net Weight (lbs/1000 ft): 110, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/2, Green Ground: 12 AWG, Conductors - Type: Stranded, Overall Diameter (in): 0.487 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., Larger sizes are supplied with a bare ground conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5)., Standards:
Color: Black-White, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/2, Conductors - Type: Solid, Ground: 10 Solid AL, Outside Diameter Over Armor (in): 0.487, Total Weight of Type MC - Copper Conductor (lbs/1000 ft): 95 Construction:, Conductors:, Available in sizes 14 AWG through 10 AWG. Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry., All conductors are individually wrapped with flame retardant colored protective paper with print legend and cabled together to form the cable core., The bare aluminum grounding/bonding conductor is located outside the paper wrap and is cabled with the insulated conductors and in constant contact with sheathing,, Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Permitted in Class I Div. 2, Class II Div. 2, and Class III Div. 1 Hazardous Locations., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Allowable installations in approved raceways and cable trays (NEC 392)., Suitable for installation under raised floors for IT equipment (NEC 645.5)., Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems., Standards:
Color: Black/White, Standard Packaging: 250' Coil, Outside Diameter Over Armor (in): 0.467, Allowable Ampacity (Amps) 60°C / 75°C / 90°C: 20 / 20 / 20, Conductors AWG: 12/2, Conductors Type: Solid, Conductors Ground: 10 Solid AL, Green THHN Copper Ground (AWG): 12, Total Weight of Type MC-Copper Conductor (lbs/1000 ft): 118 THHN/THWN-2 Copper Conductor, PVC Insulation with Nylon Jacket, Green Ground Wire, Aluminum Bonding Wire, Colored Flame Retardant Protective Paper Covering, Interlocked Aluminum Armor, Removable SmartColorID Label, Applications:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings, Acceptable for power, lighting, control, and signal circuits, Allowable in concealed or exposed systems, Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Utilized for environmental air-handling spaces (NEC 300.22) (C), Allowable in assembly occupancies (NEC 518.4), Allowable installations in approved raceways and cable trays (NEC 392), Suitable for installation under raised floors for IT equipment (NEC 645.5), Permitted in Class I Div. 2, Class II Div. 2, and Class III Div. 1 Hazardous Locations, Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems, Construction:, Standards:
Color: Black-White-Red, Approximate Net Weight (lbs/1000 ft): 132, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/3, Green Ground: 12 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.495 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Black-White-Red, Approximate Net Weight (lbs/1000 ft): 132, Standard Packaging (ft): 1000’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/3, Green Ground: 12 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.495 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Color: Black-White-Red, Approximate Net Weight (lbs/1000 ft): 136, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/3, Green Ground: 12 AWG, Conductors - Type: Stranded, Overall Diameter (in): 0.495 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., Larger sizes are supplied with a bare ground conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5)., Standards:
Color: Black/White/Red, Standard Packaging: 250' Coil, Outside Diameter Over Armor (in): 0.501, Allowable Ampacity (Amps) 60°C / 75°C / 90°C: 20 / 20 / 20, Conductors AWG: 12/3, Conductors Type: Solid, Conductors Ground: 10 Solid AL, Green THHN Copper Ground (AWG): 12, Total Weight of Type MC-Copper Conductor (lbs/1000 ft): 144 THHN/THWN-2 Copper Conductor, PVC Insulation with Nylon Jacket, Green Ground Wire, Aluminum Bonding Wire, Colored Flame Retardant Protective Paper Covering, Interlocked Aluminum Armor, Removable SmartColorID Label, Applications:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings, Acceptable for power, lighting, control, and signal circuits, Allowable in concealed or exposed systems, Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Utilized for environmental air-handling spaces (NEC 300.22) (C), Allowable in assembly occupancies (NEC 518.4), Allowable installations in approved raceways and cable trays (NEC 392), Suitable for installation under raised floors for IT equipment (NEC 645.5), Permitted in Class I Div. 2, Class II Div. 2, and Class III Div. 1 Hazardous Locations, Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems, Construction:, Standards:
Color: Black-White-Red-Blue, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 60°C: 20, Allowable Ampacities (amps) @ 75°C: 20, Allowable Ampacities (amps) @ 90°C: 20, AWG/No: 12/4, Conductors - Type: Solid, Ground: 10 Solid AL, Outside Diameter Over Armor (in): 0.506, Total Weight of Type MC - Copper Conductor (lbs/1000 ft): 148 Construction:, Conductors:, Available in sizes 14 AWG through 10 AWG. Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry., All conductors are individually wrapped with flame retardant colored protective paper with print legend and cabled together to form the cable core., The bare aluminum grounding/bonding conductor is located outside the paper wrap and is cabled with the insulated conductors and in constant contact with sheathing,, Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Permitted in Class I Div. 2, Class II Div. 2, and Class III Div. 1 Hazardous Locations., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Allowable installations in approved raceways and cable trays (NEC 392)., Suitable for installation under raised floors for IT equipment (NEC 645.5)., Listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems., Standards:
Color: Black-White, Approximate Net Weight (lbs/1000 ft): 80, Standard Packaging (ft): 250’, Allowable Ampacities (amps) @ 75°C: 15, Allowable Ampacities (amps) @ 90°C: 15, AWG/No: 14/2, Green Ground: 14 AWG, Conductors - Type: Solid, Overall Diameter (in): 0.409 Construction:, Available in sizes 14 AWG through 750 KCMIL, Encore s Metal Clad Cable is constructed with soft-drawn copper, Type THHN/THWN-2 conductors rated 90 C dry locations, Larger sizes are supplied with a bare ground conductor., Sizes 14 AWG through 1 AWG contain a green insulated grounding conductor., All conductors are cabled together with separator tape containing the identification print legend to form the cable core., Interlocked aluminum armor is applied over the entire assembly., Applications:, Type MC Cable shall be permitted as follows:, Permitted use for services, feeders, and branch circuits in industrial, commercial, and multi-residential buildings., Permitted use in dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations, Allowable installations in approved raceways and cable trays (NEC 392)., Utilized for environmental air-handling spaces (NEC 300.22)(C). Allowable in assembly occupancies (NEC 518.4)., Permissible in theatres, audience areas of motion pictures, television studios, and similar locations (NEC 520.5)., Permitted in Class I Div. 2, Class II Div.2, and Class III Div. 1 Hazardous Locations and listed for use in UL 1, 2, and 3 Hour Through-Penetration Firestop Systems,, Suitable for installation under raised floors for IT equipment (NEC 645.5). Acceptable for power, lighting, control, and signal circuits. Allowable in concealed or exposed systems., Standards:
Approximate Net Weight (lbs/1000 ft): 566, Outside Diameter Over Armor (in): 0.791, Conductor - AWG No: 6/2, Conductor - Green Ground: 8 AWG, Conductor - Type: Stranded, Packaging (ft): 500’ reels, Allowable Ampacity (Amps) - 75°C: 65, Jacket Thickness: 0.050, Outside Diameter Over Jacket (in): 0.974
Approximate Net Weight (lbs/1000 ft): 0, Outside Diameter Over Armor (in): 0.884, Conductor - AWG No: 6/3, Conductor - Green Ground: 8 AWG, Conductor - Type: Stranded, Packaging (ft): 500’ reels, Allowable Ampacity (Amps) - 75°C: 65, Jacket Thickness: 0.050, Outside Diameter Over Jacket (in): 1.045
Approximate Net Weight (lbs/1000 ft): 427, Outside Diameter Over Armor (in): 0.677, Conductor - AWG No: 8/2, Conductor - Green Ground: 10 AWG, Conductor - Type: Stranded, Packaging (ft): 500’ reels, Allowable Ampacity (Amps) - 75°C: 50, Jacket Thickness: 0.050, Outside Diameter Over Jacket (in): 0.892
Approximate Net Weight (lbs/1000 ft): 524, Outside Diameter Over Armor (in): 0.757, Conductor - AWG No: 8/3, Conductor - Green Ground: 10 AWG, Conductor - Type: Stranded, Packaging (ft): 500’ reels, Allowable Ampacity (Amps) - 75°C: 50, Jacket Thickness: 0.050, Outside Diameter Over Jacket (in): 0.957